• Title/Summary/Keyword: Body Pressure Sensor

Search Result 121, Processing Time 0.026 seconds

Triboelectric Nanogenerators for Self-powered Sensors

  • Rubab, Najaf;Kim, Sang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.79-84
    • /
    • 2022
  • Self-powered sensors play an important role in everyday life, and they cover a wide range of topics. These sensors are meant to measure the amount of relevant motion and transform the biomechanical activities into electrical signals using triboelectric nanogenerators (TENGs) since they are sensitive to external stimuli such as pressure, temperature, wetness, and motion. The present advancement of TENGs-based self-powered wearable, implantable, and patchable sensors for healthcare monitoring, human body motion, and medication delivery systems was carefully emphasized in this study. The use of TENG technology to generate electrical energy in real-time using self-powered sensors has been the topic of considerable research among various leading scholars. TENGs have been used in a variety of applications, including biomedical and healthcare physical sensors, wearable devices, biomedical, human-machine interface, chemical and environmental monitoring, smart traffic, smart cities, robotics, and fiber and fabric sensors, among others, as efficient mechanical-to-electric energy conversion technologies. In this evaluation, the progress accomplished by TENG in several areas is extensively reviewed. There will be a discussion on the future of self-powered sensors.

A Study on Oriental Medicine Hybrid Multi-cup Electric Cupping Contents using Vacuum Pressure (진공압을 이용한 한방 하이브리드 멀티 전동 부항 콘텐츠에 관한 연구)

  • Kim, Jong-Chan;Wei, Tung-Shuen;Ko, Jae-Sub;Choi, Heung-Kook;Tak, Myung-Ja;Kim, Cheeyong
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.11
    • /
    • pp.1363-1373
    • /
    • 2014
  • In this study, a hybrid multi-cup electric cupping system (HMECS) was proposed, based on the ancient cupping method. HMECS consisted of several cups that could be used simultaneously to treat different areas of the patient's body. Each cup was equipped with its own pump and pressure-monitoring system. Moreover, the vacuum pressure of the cups was controlled using fuzzy logic. Through automated control of the vacuum pressure, long-term relief of muscle tightness was achieved. To develop a scientific foundation for this alternative treatment, we compared the VAS(Visual Analog Scale) and ODI(Oswestry Disability Index) scores from conventional basic cupping to the VAS and ODI scores for our proposed HMECS. The improvement rate in the VAS and ODI scores using HMECS after three treatments was higher than that achieved by basic cupping. These results, combined with the convenience offered by enhanced IT capabilities, should increase the popularity of this device among an aging society, and facilitate the opportunity to further explore the potential of Oriental medical practices.

Changes of Cervical Range of Motion and Pelvic Mobility during Gait in Subjects with Pain-related Temporomandibular Disorders (관자 아래턱 장애에 따른 목뼈 가동 범위 제한과 보행 시 골반 가동성의 변화 연구)

  • Yeo, Sang-Seok
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.451-459
    • /
    • 2022
  • Purpose: Temporomandibular disorder (TMD) is a common musculoskeletal problem that causes pain in and disability of masticatory muscles, the temporo-mandibular joint (TMJ), and related structures. The purpose of this study was to compare pressure pain thresholds (PPTs) of masticatory muscles, cervical ranges of motion (ROM), and pelvic mobility during gait of subjects with or without TMD. Methods: In this study, pain thresholds and changes in the mobility of the cervical vertebrae and pelvis were measured in 25 patients with TMD and 25 healthy controls. Using a pressure algometer, the pressure pain thresholds (PPTs) of the masseter and temporalis muscles were measured in both groups. A gyroscope sensor with a mobile application was used to determine cervical ROM in the frontal and sagittal planes. A 3D-motion analysis system was used to evaluate pelvic mobility in the sagittal, frontal, and transverse planes during gait. Results: The TMD group showed significantly decreased PPTs of masseter and temporalis muscles compared with the control group (p < 0.05). Cervical ROM in flexion, extension, and lateral bending were significantly decreased in the TMD group compared with the control group (p < 0.05). In addition, antero-posterior pelvic tilt was significantly decreased in the TMD group (p < 0.05). Conclusion: The results of the current study suggest that there are close anatomical and functional relationships between TMD and muscle chains related to the cervical spine and pelvis. Therefore, more comprehensive body posture assessments, especially of painful areas, should be undertaken when studying TMD patients.

Bio-Signal Detection Monitoring System Using ZigBee and Wireless Network (ZigBee와 무선 네트워크를 이용한 생체신호 검출 모니터링 시스템)

  • Kim, Kuk-Se;Bang, Sun-Kwang;Lee, Jeong-Gi;Ahn, Seong-Soo;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.477-481
    • /
    • 2007
  • The emergency patient who occurs from the place where it is various the control which is quick must come to accomplish in Ubiquitous environment. In the body of the patient or the old person the organism signal sensor about under attaching condition of the patient at real-time about under the monitor ring about under disposing the control which is quick against the emergency patient does to become accomplished at the case real-time when the above will get in the body of the patient or the old person. Using ZigBee (802.15.4) system base on Shor wireless communication protocol because of complement wireless of hospital. This system use ZigBee (802.15.4) system to get for electrocardiogram, blood pressure and pulse bio-sensors. This paper constructs Bio-Sensor communication monitoring system and transmission rate and the delay which it follows possibility and node occurrence rate of wireless sensor network construction hour transmission session it leads and it verifies the effectiveness.

  • PDF

Design and Implementation of U-healthcare system with zigbee in service integration system (서비스 통합 시스템에서 지그비를 이용한 유비쿼터스 헬스케어 시스템의 설계 및 구현)

  • Jang, Mun-Suck;Shin, Kwang-Sik;Cheong, Jin-Ha;Yee, Yang-Hee;Shim, Jae-Hong;Lee, Eung-Hyuk;Choi, Sang-Bang
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.16-24
    • /
    • 2006
  • In this paper, we implement a U-healthcare system that can be applied to a service integration system. This system consists of a wireless network system a sensor module, and a integration server. The wireless network system collects data and the sensor module measures body fat, blood pressure, quantity of exercise, and SPO2. The server integrates user certification, security service and VOD service and collects user health information in real-time, and sends the data in case of emergency to a doctor or guardian.

A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

Estimation of Stroke Volume Based on Air Pressure in Air Tube with Pneumatic Pulsatile Ventricular Assist Device (공압식 박동형 심실보조장치에서 공압관 내 공기압에 따른 박출량 추정)

  • Kang, Yu Min;Lee, Jin Hong;Her, Keun;Choi, Seong Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.971-974
    • /
    • 2014
  • A ventricular assist device (VAD) is used for bridge to heart transplantation and heart diseases. Knowing the status of a pneumatic pulsatile VAD when implanting it into the body is important: when the velocity of blood flow through the VAD is slow, a thrombus may occur, and thrombosis can be fatal to a patient. In order to determine the state of a VAD, various sensors need to be implanted. Because this introduces the risk of infection and difficulties with sensor management, we developed a method for estimating the state of a VAD indirectly via the pressure in an air tube that can be measured in vitro. We compared the measured values to in vitro experimental results. The estimated and measured values showed some errors, but the accuracy can be improved by refining the estimation process to minimize the risk of infection.

Surface modifiers on the waterglass aerogels prepared by ambient drying process (상압건조 물유리 에어로젤에 대한 표면개질제의 영향)

  • Kim, Tae-Jung;Nahm, Sahn;Oh, Young-Jei
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • Silica aerogel with ultra low density and high porosity has been focused on versatile application due to its fascinating properties. Ambient drying process of waterglass, in this study was researched to fabricate a crack-free monolith body in the point view of cost effective way. Wet gel was obtained by removing of $Na^{+}$ ions in waterglass, which contains 8 wt% of $SiO_{2}$. Xylene, which has a low vapor pressure, was used as a solution substitutor to prevent the formation a cracks during drying. Various surface modifiers like as hexamethyldisilazane (HMDSZ), trimethylchlorosilane (TMCS), methyltriethoxylsilane (MTES), methyltrimethoxysilane (MTMS) and phenyltriethoxysilane (PTES) were used in order to improve hydrophobicity of the waterglass Silica aerogel. Some physical properties of the surface modified aerogels were investigated by FT-IR, TGA, BET and SEM. Hydrophobicity and hydrophilicity of Silica aerogel is attributed to the Si-OH bond and the non-polar C-H bond groups on the surface of aerogel. Crack-free waterglass aerogel with >90 % of porosity, 17 nm of pore size and <0.15 $g/cm^{3}$ of density was prepared. HMDSZ and TMCS are effective as a surface modifier

A Study on the Development of Medical Service Robot (의료용 서비스 로봇 개발에 관한 연구)

  • Kang, Sung-In;Park, Yoon-A;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1245-1250
    • /
    • 2011
  • In this paper, we designed efficient reception system using service robot based on the RFID(Radio Frequency Identification) and HL7(Health Level 7) Protocol. The proposed system offer a paramedic the medical information of the patient, and the patients can receive on a much simpler scale than previously through stable and quick information exchange by RFID and HL7. In addition, We considered environment of medical treatment and designed and implemented standard HL7 message structure. This system was implemented service robots to reception of medical treatment. Furthermore, we have plan to develop bio-sensor which can measure blood pressure, body temperature, etc and interface with robot system by HL7.

Suggestion of Structural Analysis Model Using Auxiliary Rehabilitation Device for a Patient of Spinal Curvature (척추측만증 환자의 재활 치료 보조기 개발을 위한 구조 해석 모델 제시)

  • Bak, Jeong-Il;Yoon, Ho-Cheul;Kou, Heung;Yum, Deuk-Joon;Sun, Dong-Youn;Kim, Young-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.141-144
    • /
    • 2009
  • The purpose of this study is to develop the auxiliary rehabilitation device for a patient of spinal curvature. The adolescent diopathic scoliosis(AIS) must be treated by rehabilitation brace if Cobb angle is $20^{\circ}{\sim}40^{\circ}$. The rehabilitation brace is consist of 4 vest and 2 hinge parts(hinge and couple bar) that give a force to the ribs. But thin and light hinge parts for young patient failed easily because of unusual movement of the upper body. We studied optimum design and structural analysis of hinge parts when it distorted by tensile and bending force. The specimen of hinge parts were tested to evaluate the failure strength. And we attached circuits with memory and sensor detecting pressure and displacement to recoding stress in hinge parts. These data are used to alarm the patient to stop unusual movement and understand the load history.

  • PDF