• 제목/요약/키워드: Blunt Body

검색결과 94건 처리시간 0.027초

주기적 불안정성을 가지는 충격파 유도 연소의 무차원 해석 (Nondimensional Analysis of Periodically Unstable Shock-Induced Combustion)

  • 최정열;정인석;윤영빈
    • 한국연소학회지
    • /
    • 제1권2호
    • /
    • pp.41-49
    • /
    • 1996
  • A numerical study is conducted to investigate the periodically unstable shock induced combustion around blunt bodies in stoichiometric hydrogen-air mixtures. Euler equations are spatially discretized by upwind-biased third order scheme and temporally integrated by Runge-Kutta method. Chemistry model used in this study involves 8 elementary kinetics steps and 7 species. At a constant Mach number, the effects of projectile size, inflow pressure and inflow temperature are examined with Lehr#s experimental condition as a reference. In addition to oscillation frequency, characteristic distances and time averaged values are found from the result to find an relation with dimensionless parameters. As a result, it is found that the effects of inflow pressure and body size are very similar and $Damk{\ddot{o}}hler$ number plays an important role in determining the instability characteristics.

  • PDF

EFP 설계의 전산 해석 (Computational Analysis of EFP Design)

  • 최서원;강호철;홍종태;이상길
    • 한국군사과학기술학회지
    • /
    • 제2권2호
    • /
    • pp.110-116
    • /
    • 1999
  • Supersonic flows over an EFP(explosively formed projectile) have been calculated by a high-order conservation law scheme and two-layer $$textsc{k}$-{\varepsilon}$ model on hybrid viscous unstructured mesh. To verify the accuracy and robustness of the developed code, two basic flows about airfoils are computed and results are compared with existing experimental data and computational results. The comparisons confirm the validity of the code and justify our use for such a highly supersonic and viscous flow over a blunt body. Complex flow features of supersonic flows over an EFP are clearly captured and show agreements with the flow visualization. From the interaction of oblique shocks near the surface of flare, flow structures, that were not identified by previous experimental results, are discovered as a result of present computation.

  • PDF

Fractured needle as an unusual complication of the lingual nerve block: a case report

  • Erdil, Aras;Demirsoy, Mustafa Sami;Colak, Sefa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권4호
    • /
    • pp.315-321
    • /
    • 2022
  • Although rare, hypodermic needle fractures can occur in the maxillofacial region. In cases of fracture, urgent intervention is required to prevent further complications. We present the case of a 37-year-old female patient with a fractured needle in the left sublingual fossa during a lingual nerve block 6 months before referral. The fragment of a 30-gauge needle was located using cone-beam computed tomography and retrieved under local anesthesia with blunt dissection. The patient recovered uneventfully, except for predictable postoperative inflammatory complications, which resolved within 2 weeks. Precautions should be implemented to prevent needle fractures, which are usually preventable. However, if the retrieval is unsuccessful, the patient should be referred to a well-equipped surgical unit without delay.

Management of Gastrointestinal Foreign Bodies with Brief Review of the Guidelines

  • Kaan Demiroren
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제26권1호
    • /
    • pp.1-14
    • /
    • 2023
  • Foreign body (FB) ingestion is a common health problem that affects children more than adults. According to gastroenterologists' guidelines, the management of FB ingestion differs slightly between adult and children. This review aimed to compile adult and children guidelines and establish an understandable association to reveal the requirements and timing of the endoscopic procedure, which is the most effective and least complicated technique for gastrointestinal FBs. Coins, pins, and chicken and fish bones have been the most commonly ingested FBs. However, with their increasing use in recent years, large batteries with lithiumion conversion, stronger magnets composed of rare earth metals, such as neodymium, and superabsorbent objects have become the most morbid and mortal, necessitating new management strategies. Although the approach to gastrointestinal FBs is controversial, with different treatment options available in different disciplines, many studies have demonstrated the efficacy and safety of endoscopic procedures. Many factors influence the timing of endoscopy, including the nature, size, and location of the ingested object and the patient's clinical condition.

Computation of aerodynamic coefficients of a re-entry vehicle at Mach 6

  • R.C. Mehta;E. Rathakrishnan
    • Advances in aircraft and spacecraft science
    • /
    • 제10권5호
    • /
    • pp.457-471
    • /
    • 2023
  • The paper evaluates the aerodynamic coefficients on a blunt-nose re-entry capsule with a conical cross-section followed by a cone-flare body. A computer code is developed to solve three-dimensional compressible inviscid equationsfor flow over a Space Recovery Experiment (SRE) configuration at different flare-cone half-angle at Mach 6 and angle of attack up to 5°, at 1° interval. The surface pressure variation is numerically integrated to obtain the aerodynamic forces and pitching moment. The numerical analysis reveals the influence of flare-cone geometry on the flow characteristics and aerodynamic coefficients. The numerical results agree with wind tunnel results. Increase of cone-flare angle from 25° to 35° results in increase of normal force slope, axial forebody drag, base drag and location of centre of pressure by 62.5%, 56.2% and 33.13%, respectively, from the basic configuration ofthe SRE of 25°.

Seasonal Acclimatization in Summer versus Winter to Changes in the Sweating Response during Passive Heating in Korean Young Adult Men

  • Lee, Jeong-Beom;Kim, Tae-Wook;Min, Young-Ki;Yang, Hun-Mo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제19권1호
    • /
    • pp.9-14
    • /
    • 2015
  • We investigated the sweating response during passive heating (partial submersion up to the umbilical line in $42{\pm}0.5^{\circ}C$ water, 30 min) after summer and winter seasonal acclimatization (SA). Testing was performed in July during the summer, 2011 [summer-SA; temp, $25.6{\pm}1.8^{\circ}C;$ relative humidity (RH), $82.1{\pm}8.2%$] and in January during the winter, 2012 (winter-SA; temp, $-2.7{\pm}2.9^{\circ};$ RH, $65.0{\pm}13.1%$) in Cheonan ($126^{\circ}52^{\prime}N$, 33.38'E), Republic of Korea. All experiments were carried out in an automated climatic chamber (temp, $25.0{\pm}0.5^{\circ}C$: RH, $60.0{\pm}3.0%$). Fifteen healthy men (age, $23.4{\pm}2.5$ years; height, $175.0{\pm}5.9cm;$ weight, $65.3{\pm}6.1kg$) participated in the study. Local sweat onset time was delayed during winter-SA compared to that after summer-SA (p<0.001). Local sweat volume, whole body sweat volume, and evaporative loss volume decreased significantly after winter-SA compared to those after summer-SA (p<0.001). Changes in basal metabolic rate increased significantly after winter-SA (p<0.001), and tympanic temperature and mean body temperature were significantly lower after summer-SA (p<0.05). In conclusion, central sudomotor acitivity becomes sensitive to summer-SA and blunt to winter-SA in Rebubic of Korea. These results suggest that the body adjusts its temperature by economically controlling the sweating rate but does not lower the thermal dissipation rate through a more effective evaporation scheme after summer-SA than that after winter-SA.

관통성 손상에 의한 심장내 이물 - 수술 치험 1례 - (Intracardiac Foreign Body by Penetrating Cardiac Injury)

  • 정진용
    • Journal of Chest Surgery
    • /
    • 제23권5호
    • /
    • pp.929-935
    • /
    • 1990
  • Violence in our society, combined with improving transport system, resulted in increased numbers of patients with cardiac wounds reaching the hospital alive. Most patients with penetrating cardiac injury, rather than blunt injury, present with a syndrome of either hemorrhagic shock or cardiac tamponade. And they should be operated upon as soon as possible. Often the atrioventricular valves and other important cardiac structures are also damaged by the penetrating instruments or missile. Both intracardiac communications and atrioventricular fistulas may result in significant left-to-right shunts accompanied by congestive heart failure, necessitating surgical correction. Usually, retained cardiac foreign bodies, which are almost always bullets or fragments of missiles, may lie within a cardiac chamber or in the myocardium. Emboli of bullets or other missiles from distant sites to the right side of the heart are numerous enough to require attention. Recently we experienced a case with intracardiac foreign body due to penetrating cardiac injury. A 19 year-old man was admitted to our hospital due to penetrating anterior chest wound by iron segment. The roentgenogram of the chest revealed a radio-opaque metallic shadow in left lower chest around the cardiac apex, mild blunting of left costophrenic space, but no cardiomegaly. During operation the foreign body was noted to be present in the cardiac chamber by the portable C-arm fluoroscopy. But during the manipulation it moved into left inferior pulmonary vein from left ventricle by way of left atrium. So we could manage to remove it from left inferior pulmonary vein by direct approach to the vein. It was iron segment, sized 0.lcm x0.6cmx0.5cm, with sharp margins. The patient had an uneventful postoperative recovery except for chylopericardium and was discharged.

  • PDF

압력비가 변할 때 축대칭 초음속 노즐의 플룸 구조 해석 (Plume Structure Analysis of an Axisymmetric Supersonic Micro-nozzle at the Various Pressure Ratios)

  • 권순덕;김성초;김정수;최종욱;김용석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2862-2867
    • /
    • 2007
  • The steady non-reacted compressible flow field in a symmetric micro-thruster, which is used for the accurate attitude control of a satellite, is analyzed varying the nozzle pressure ratio (NPR) to investigate the plume characteristics. The nozzle throat diameter is 0.06 inch and the area ratio is 56. The recirculation region is found just behind the normal shock at the several NPRs due to the locally adverse pressure gradient along the nozzle centerline when the environmental pressure is atmospheric. This phenomenon, the cause of flow loss, is similar to the flow behind a blunt body. As NPR increases the location of Mach disk, characteristics of the normal shock, moves downstream and its strength increases. The Mach number distribution appears in a wave-type patter after the normal shock because oblique shocks are reflected on the shock boundaries especially when NPRs are very high.

  • PDF

터빈 블레이드 선단에서의 샤워헤드 막냉강 - 국소분사율 측정 및 유동의 가시화 - (Shower-Head Film Cooling on the Leading Edge of a Turbine Blade: Measurements of Local Blowing Ratio and Flow Visualizations)

  • 정철희;이상우
    • 대한기계학회논문집B
    • /
    • 제23권3호
    • /
    • pp.419-430
    • /
    • 1999
  • Measurements of local blowing ratio and ammonia-diazo flow visualizations have been conducted for a shower-head film cooling on a first-stage turbine stator. In this study, six rows of normal holes are drilled symmetrically on the semicircular leading edge of a simulated blunt body. The measurements show that for an average blowing ratio based on freestream velocity, M, of 0.5, local average mass flow rate through the first two rows of the holes is less than those through the second and third two rows of the holes, and the fraction of mass flow rate through the first two rows to total mass flow rate has a tendency to increase with the increment of M. The flow visualizations reveal that the injection through the first two row results in inferior film coverage even In the case of M = 0.5, meanwhile the row of holes situated at farther downstream location provides higher film-cooling performances for all tested M. This is because film-cooling effectiveness depends on local mainflow velocity at the hole location as well as the mass flow rate through each row.

샤워헤드 막냉각면에서의 온도장 및 막냉각효율 측정 (Measurements of Temperature Field and Film-Cooling Effectiveness for a Shower-Head Film Cooling)

  • 정철희;이상우
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.177-187
    • /
    • 2000
  • Measurements of temperature fields and film-cooling effectiveness have been conducted for a shower-head film cooling on the leading edge of a blunt body, which simulates a first-stage turbine stator. In this study, three injection cases are employed for an average blowing ratio based on freestream velocity, M, of 0.5, 1.0 and 1.5. Two (Case 1), four (Case 2) and six (Case 3) rows of normal holes are symmetrically drilled on the three tested circular-cylinder leading edges. The measurements show that regardless of M, the film-cooling effectiveness increases as the injection row is situated at farther downstream location. In Case 1, the film-cooling effectiveness is highest for M = 0.5 and lowest for M = 1.5. On the contrary, in Case 3, the film-cooling effectiveness is highest for M = 1.0 and lowest for M = 0.5. When M = 0.5, the film coverage by the first row of the injection holes deteriorates as the number of the injection row increases. In particular, the film-cooling effectiveness due to the injection through the first row of the holes in Case 3, has a nearly zero value.