• Title/Summary/Keyword: Bluetooth technology

Search Result 529, Processing Time 0.027 seconds

A Study of Mobile Patient Identification System Using EM4095 (EM4095를 이용한 모바일 의료환자인식 시스템 연구)

  • Jo, Heung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2337-2342
    • /
    • 2010
  • There is a vast field of application for RFID(Radio Frequency IDentification) technology. In the case of hospitals, RFID can be used for organizing patient data. Generally, patient data has been handled with medical cards. In order to look up data about a patient, the medical card would have to be found first, within a lot of other medical cards, by hand or with a computer. This is a very inconvenient system. Also, if the card is searched by the name of the patient, fatal medical accidents may occur in cases of mix-ups. If remote RFID Tag monitoring systems are applied in this case, the patient data would be accessible in the hospital. This article will discuss the grafting of RFID systems and wireless data communicating technology. The EM4095 chip, which uses 125KHz carrier waves was used in this study. And a Bluetooth module was added for wireless data communication. The ATMEGA128 microcomputer was used to control the RFID system and wireless module. A LCD monitor was connected to the extension port for nurses to view patient data, and also, the same information was displayed on PC monitors for doctors to see. The circuit was designed to consume minimal amounts of electricity for portability, and to transmit Tag ID's in environments with a lot of noise. The article is concluded with a diagram of the whole system, and performance of each data transmitting section has been analyzed.

Development of Self-trainer Fitness Wear Based on Silicone-MWCNT Sensor (실리콘-탄소나노튜브 센서 기반의 셀프트레이너 피트니스 웨어 개발)

  • Cho, Seong-Hun;Kim, Kyung-Mi;Cho, Ha-Kyung;Won, You-Seuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.493-503
    • /
    • 2018
  • Recently, as living standards have improved, many people are becoming more interested in health, and self-training is increasing through exercise to prevent and manage pre-illness. In general, an imbalance of muscles causes asymmetry of posture, which can cause various diseases by accompanying an adjustment force, circulation action, displacement of internal organs, etc.. In this study, the development of fitness software that can be self - training among smart wears has attracted considerable attention in recent years. In this study, a technology was proposed for the commercialization of self - trainer fitness wear by a simulation through Android - based applications. Self - trainer fitness software was developed by combining a conductive polymer, fashion design, sewing, and electric and electronic technology to monitor the unbalance of the muscles during exercise and make smart wear that can calibrate the asymmetry by oneself. In particular, a polymer sensor was fabricated by deriving the optimal MWCNT concentration, and the electrode signal was collected by attaching the electrode to the optimal position, where the electrode signal line using the conductive fiber was designed and attached to collect the signal. A signal module that converts the bio-signals collected through electrical signal conversion and transmits them using Bluetooth communication was designed and manufactured. Self-trainer fitness software that can be commercialized was developed by combining noise cancellation with Android-based self-training application using a software algorithm method.

IoT Open-Source and AI based Automatic Door Lock Access Control Solution

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Mariappan, Vinayagam;Young, Ko Eun;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.8-14
    • /
    • 2020
  • Recently, there was an increasing demand for an integrated access control system which is capable of user recognition, door control, and facility operations control for smart buildings automation. The market available door lock access control solutions need to be improved from the current level security of door locks operations where security is compromised when a password or digital keys are exposed to the strangers. At present, the access control system solution providers focusing on developing an automatic access control system using (RF) based technologies like bluetooth, WiFi, etc. All the existing automatic door access control technologies required an additional hardware interface and always vulnerable security threads. This paper proposes the user identification and authentication solution for automatic door lock control operations using camera based visible light communication (VLC) technology. This proposed approach use the cameras installed in building facility, user smart devices and IoT open source controller based LED light sensors installed in buildings infrastructure. The building facility installed IoT LED light sensors transmit the authorized user and facility information color grid code and the smart device camera decode the user informations and verify with stored user information then indicate the authentication status to the user and send authentication acknowledgement to facility door lock integrated camera to control the door lock operations. The camera based VLC receiver uses the artificial intelligence (AI) methods to decode VLC data to improve the VLC performance. This paper implements the testbed model using IoT open-source based LED light sensor with CCTV camera and user smartphone devices. The experiment results are verified with custom made convolutional neural network (CNN) based AI techniques for VLC deciding method on smart devices and PC based CCTV monitoring solutions. The archived experiment results confirm that proposed door access control solution is effective and robust for automatic door access control.

A Study on Indoor Position-Tracking System Using RSSI Characteristics of Beacon (비콘의 RSSI 특성을 이용한 실내 위치 추적 시스템에 관한 연구)

  • Kim, Ji-seong;Kim, Yong-kab;Hoang, Geun-chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.85-90
    • /
    • 2017
  • Indoor location-based services have been developed based on the Internet of Things technologies which measure and analyze users who are moving in their daily lives. These various indoor positioning technologies require separate hardware and have several disadvantages, such as a communication protocol which becomes complicated. Based on the fact that a reduction in signal strength occurs according to the distance due to the physical characteristics of the transmitted signal, RSSI technology that uses the received signal strength of the wireless signal used in this paper measures the strength of the transmitted signal and the intensity of the attenuated received signal and then calculates the distance between a transmitter and a receiver, which requires no separate costs and makes to implement simple measurements. It was applied calculating the value for the average RSSI and the RSSI filtering feedback. Filtering is used to reduce the error of the RSSI values that are measured at long distance.It was confirmed that the RSSI values through the average filtering and the RSSI values measured by setting the coefficient value of the feedback filtering to 0.5 were ranged from -61 dBm to - 52.5 dBm, which shows irregular and high values decrease slightly as much as about -2 dBm to -6 dBm as compared to general measurements.

A Study on Movement Control of Drone using Reference Posture Mapping (기준 자세 맵핑을 이용한 드론의 동작 제어에 관한 연구)

  • Kim, Jang-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.6
    • /
    • pp.461-466
    • /
    • 2021
  • Drone can be controlled by the method such as Bluetooth communication for close distance and can be controlled through network communication for long distance. Especially, the coordinate is set using GPS and drone is controlled using network communication and video communication when the activity range is long distance. However, the drone should be controlled by receiving control authority accordingly in response about it appropriately when the drone leaves the control area after arriving at the destination if there is a problem with network communication and video communication. So, this study proposes a method to control a drone with a simple mutually promised simple gesture and the drone can be controlled in the proposed method even if the drone leaves from the control authority in above situation. The reference posture was established for mutually promised simple gesture algorithm and automatically handed over the control authority of drone to a person who takes the reference posture when the drone recognizes it to implement this. And all the movements of the drone could be controlled by starting the beginning of all commands from the reference posture (The hovering posture of the drone). Lastly, the control authority of the drone should be returned after achieving the purpose, and the algorithm was implemented to make the drone can perform next action of its own, and it was confirmed that the drone was operating normally by the mapped instruction.

Smartphone-Attachable Vascular Compliance Monitoring Module (스마트폰 탈착형 혈관 탄성 모니터링 모듈)

  • Se-Hwan Yang;Ji-Yong Um
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.221-227
    • /
    • 2024
  • This paper presents a smartphone-attachable vascular compliance monitoring module. The proposed sensor module measures photoplethysmogram (PPG) and reconstructs an accelerated PPG waveform. The feature points are extracted from the accelerated PPG waves, and vascular compliance is estimated using these extracted features. The module is powered via the smartphone's USB terminal and transmits the acquired waveforms along with vascular compliance values through Bluetooth. The transmitted waveforms and vascular compliance value are displayed through the smartphone application. This work proposes an assessment method for consistency of PPG instrumentation, and it was implemented in a processor of sensor module. The proposed sensor module can be easily attached to smartphone that does not support PPG instrumentation, providing simple measurment and numerical analysis of vascular compliance. To verify the performance of the implemented sensor module, we acquired vascular compliance and pulse pressure data from 29 subjects. Pulse pressure, which serves as a representative indicator of vascular compliance, was obtained using a commercial blood pressure monitor. The analysis results showed that the Pearson coefficient between vascular compliance and pulse pressure was 0.778, confirming a relatively high correlation between two metrics.

The Development of the Smart Sensibility Mat with Kangaroo Mother Care (캥거루 케어를 반영한 스마트 감성 매트의 개발)

  • Cho, Soo-Min
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • 'Smart Sensibility Mat (SSM)' was developed and manufactured for positive sensibility of newborn with fiber, digital, and sensibility technology to reflect features and advantages of kangaroo care. For tactile stimuli, the tube of the silicon material to provide a constant temperature of $32^{\circ}C$ was inserted into the mat and connected to the water-thermostat. To provide a uniform temperature throughout the mat, the fabric by the inserting conductive yarn was attached to the mat surface. After wrapping the mat with cotton pad, the polyurethane foam used as medicine in order to similar to the human skin was bonded to the surface of the mat. To provide the auditory stimuli of a level of 30dB with mother's heartbeat sounds and voice recorded in advance, the Bluetooth speaker was inserted into the mat. To investigate the effects of SSM, 10 newborns who born within two weeks were involved in this experiment. While the baby was lying on each of the general mat (GM) and SSM, the baby's physiological signals-heart rate, breathing rate, temperature- were measured and then, those were conducted t-test to examine the difference between the signals of SSM and GM. The results were as follows: heart rate (t=8.131, p<.001) and respiratory rate (t=7.227, p<.001) among the physiological signals of SSM decreased significantly than GM within the normal range. Temperature (t=1.062, p=0.292) at SSM showed a tendency to decrease than GM within the normal range. This means the tactile stimuli and the auditory stimuli providing from SSM give stable physiological responses. Thus, SSM leads to have psychological comfort and stability of newborns.

Spin Test of 5 kWh Composite Flywheel Rotor (5 kWh 복합재 플라이휠 로터의 회전 시험)

  • Han, Hoon-Hee;Ha, Sung-Kyu;Kim, Jae-Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3135-3140
    • /
    • 2010
  • A 5 kWh composite flywheel rotor was designed and manufactured, and its spin test was performed to monitor strain distribution and burst speed. Strain distribution in radial and circumferential directions of the rotor were measured using a wireless telemetry system based on bluetooth technology for real-time strain measurement. The strains was compared with pre-calculated design values to verify the initial rotor design. We noticed the rotor failed at 19,499 rpm in the spin test, 11 % lower than the predicted burst speed of 22,000 rpm. Failure occurred at the hub which connects the shaft and the composite rotor. The performance of the composite rotor was confirmed in a general sense, and the danger of unexpected failure of composite rotor during high-speed spinning was also demonstrated in this paper. Special attention should be paid to not only composite rotor but also hub when designing a flywheel energy storage system. The telemetry system needs to be further developed, especially enduring the high centrifugal forces, and can be used in a real time monitoring system for the flywheel energy storage system.

An IT/Medical Converged Solution based on the Expert System for Enhancing U-Healthcare Services in Middle-sized Medical Environment (중소형 의료 환경에서 U-헬스케어 서비스 향상을 위한 전문가 시스템 기반 IT/의료 융합 솔루션)

  • Ryu, Dong-Woo;Kang, Kyung-Jin;Cho, Min-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1318-1324
    • /
    • 2010
  • Recently, U-Healthcare is receiving attentions as a research for reducing the manpower, time in treatment, and etc. Although fundamental technologies, such as sensing, measuring, and etc. are sufficiently investigated. However, Technologies of IT/Medical convergence, which graft IT technologies to medical area, are still in germ. For this, we present a novel healthcare system, which can be applied to the middle sized medical environment, such as private hospital, home, or etc., by means of pre-verified technologies and the expert system. There exist IT element technologies are sufficiently developed in the fields, such as network, database or etc. due to the remarkable developments in IT technologies, and the healthcare is a mission-critical environment. Therefore, it is important not only to investigate novel approaches but also to utilize verified technologies for the U-Healthcare solution. Presented solution provisions automated medical services based on expert system by utilizing the measured data, such as body fat, blood pressure, blood glucose, and etc., in order to provide convenient treatment environment to doctors and nurses. In addition, since people, who do not have medical knowledge, can self-diagnose themselves, it is expected to cut medical costs in various areas. Especially, since each devices communicate with each other through standardized Bluetooth technology, Presented healthcare system is an extensible solution which can easily accept various medical devices. As a result of this, we can safely say that the self measurement and diagnosis services in U-Healthcare are now enhanced by reducing medical cost through our healthcare system.

Effect of light touch on body sway during a stable posture with blocked visual information

  • Kim, Jong-Gun;Kim, Jin-Hong;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.138-142
    • /
    • 2016
  • Objective: The purpose of this study was to investigate how light touch with a finger affects balance ability when a posture is maintained in the condition of visual information blockage and to provide a fundamental material for developing balance ability in the process of rehabilitation treatment. Design: Cross-sectional study. Methods: The study subjects were 17 healthy men and women in their twenties and thirties who were studying at S University in Seoul. The system was comprised of an equilateral triangular force platform. Subjects were asked to step on the foot position of the force platform (Good Balance, Finland) barefooted for 30 seconds, with eyes closed, hands hanging down loosely, and feet comfortably apart. It was connected to a laptop by using Bluetooth technology. An experiment was conducted in the following three circumstances: 1) no-touch trial, 2) light touch to the back (T7 area), and 3) light touch to the middle finger of the left hand. Each subject was given a 10-minute break between consecutive measurements. The experimental circumstances were performed randomly. Anteroposterior sway (APSV), mediolateral sway velocity (MLSV), and velocity moment (VM) were measured. Results: The APSVs (mm/s) were $9.32{\pm}3.37$ and $5.45{\pm}2.98$; the MLSVs (mm/s), $6.39{\pm}3.35$ and $3.31{\pm}2.48$; and VM ($mm^2/s$), $17.13{\pm}11.75$ and $6.76{\pm}8.31$ in the first and second experimental circumstances, respectively. APSV, MLSV, and VM values were significantly improved with the 1) no-touch trial and 2) light touch to the back trail conditions compared with the 3) light touch to the middle finger of the left hand condition (p<0.05). Conclusions: This study revealed that the balance ability for maintaining a body posture was influenced more by light touch to the back (T7) than by light touch with the sensitive fingertip and body sway diminished after visual information was blocked.