• Title/Summary/Keyword: Blow-down

Search Result 65, Processing Time 0.023 seconds

Quantitative and Qualitative Assessment of Blow Down Wastewater from Yeosu Industrial Complex (여수석유화학산단 산업폐수 재이용을 위한 블로우 다운 (Blow Down)수 발생현황 조사)

  • Kwon, Tae-Ouk;Moon, Il-Shik
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.289-296
    • /
    • 2005
  • Purpose of this research is to quantitatively and qualitatively investigate the blow down wastewater produced from Yeosu Industrial Complex. Approximately, 38,325,000 tons/year of wastewater is produced, processed and finally discharged. Six representative companies, namely, A, B, C, D, E, F were chosen for this study. Each company produce over 5,000 tons/day of wastewater. In total, 6,844 tons/day of blow down water is produced from these six companies, put together. However, companies A and C produce about 24% and 37% of blow down water, respectively. It was found that the blow down water had favorable qualities, except for its high conductivity, ranging from 230 to $1,700{\mu}s/cm$. It was evident that, this water can be suitable for reuse, for industrial purposes, if a suitable treatment, for example, RO membrane process is adopted to remove high conductivity.

Mathematical modeling study for the stagnation pressure control system of the blow-down type wind tunnel (불어내기식 풍동의 정체실 압력제어 시스템 모델링)

  • 김영준;권정태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.206-211
    • /
    • 1992
  • A mathematical model of the blow-down type wind tunnel is developed in order to design the controller which controls the stagnation pressure being used to obtain the setpoint Mach Number. The motion of compressible fluids in the tunnel is modeled using the one-dimensional gasdynamics. The time responses of the wind tunnel states, such as pressures, mass flow rates, and valve open area, are investigated by digital computer simulation. By the simulation study it is shown that the real blow-down wind tunnel can be simulated by the obtained mathematical model.

  • PDF

A Study on Modeling of the Pneumatic Part in a Gas Blow-Down System Including Pressure Regulator and Pipe-Line Characteristics (압력조절밸브와 배관 특성을 포함한 유도무기용 기체 블로우다운 시스템의 공압부 모델링에 관한 연구)

  • Park, Youngwoo
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.32-39
    • /
    • 2017
  • In this study, a mathematical model of the pneumatic part in a gas blow-down system is proposed. The mathematical model consists of four major parts: pressure vessel, reservoir, pressure regulator and pipe-line. To ensure accuracy in long-time simulations, heat transfer between gas and pressure vessel is considered. The model is validated by comparing simulation results with experimental data. Experiments are conducted on the ground, where free convection can be assumed. Simulation results indicate the proposed model can accurately describe behavior of a gas blow-down system. Therefore, it may be used for design and analysis of similar systems with a slight modification.

The Hybrid Rocket Internal Ballistics with Two-phase Fluid Modeling for Self-pressurizing $N_2O$ I (자발가압 성질을 가진 아산화질소의 2상유체 모델링을 통한 하이브리드 로켓 내탄도 해석 I)

  • Lee, Jung-Pyo;Rhee, Sun-Jae;Woo, Kyoung-Jin;Oh, Ji-Sung;Jung, Sik-Hang;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.45-49
    • /
    • 2011
  • The blow-down oxidizer feed system with self-pressurizing $N_2O$ has more advantages than the regulated system. However, it is difficult to predict the exhaust flow rate because there exist two phases in the $N_2O$ tank - liquid phase and gas phase, and the properties of $N_2O$ in storage tank are varied continuously during blow-down. In this paper, a method that can analyse simply the blow-down oxidizer feed system is studied. The properties of saturated $N_2O$ are found from the NIST data base, and mass flow through the orifice is modeled as NHNE. Cold flow test with hybrid rocket combustor is performed for the comparison where the results should found from the good agreement.

  • PDF

Modeling and Simulation of the Pneumatic Part in a Cold Gas Blow-Down Type Hydraulic Actuation System for a Missile (상온기체 블로우다운 방식을 사용한 유도무기용 유압식 구동장치의 공압부에 대한 모델링 및 시뮬레이션)

  • Park, Hee Seung
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 2016
  • A cold gas blow-down hydraulic actuation system is widely used in missiles that require an actuation system with a fast response time under a limited space with a short operating time and large loads on the actuators. The system consists of a pneumatic part that supplies the regulated high-pressure gas to a reservoir, and a hydraulic part that supplies pressurized hydraulic oil to the actuators by the pressurized gas in the reservoir. This paper proposes a mathematical model to analyze and simulate the pneumatic part of an actuation system that supplies the operating power to the actuators. The mathematical model is based on the ideal gas equation and also considers the models for heat transfer. The model is applied to the pressure vessel and the gas part of the reservoir, and the model for the pneumatic part is established by connecting the two models for the parts. The model is validated through a comparison of the simulation results with the experimental results. The comparison shows that the suggested model could be useful in the design of the pneumatic part of a cold gas blow-down type hydraulic actuation system.

The Causes of Blow-out Fracture in Old Age Patients and Their Computed Tomography Findings and Associated Facial Bone Fracture (고연령 안와파열 골절 환자의 수상 원인과 컴퓨터 단층촬영 소견 및 동반 골절의 연령별 비교)

  • Seo, Dong Woo;Sohn, Chang Hwan;Jung, Sang Ku;Ahn, Shin;Kim, Won Young;Kim, Won
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.44-50
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the causes of blow-out fractures, the computed tomography findings, and the associated facial bone fractures in aged patients. Methods: This study was performed by conducting a chart review. From January 2004 to December 2007, the patients who visited the emergency room of Asan Medical Center and were diagnosed as having a blow-out fracture were included in the study population. Patients 60 years of age or older were grouped as the aged group while patients younger than 60 years of age were grouped as the control group. Results: Between the aged group and the control group, there was a difference in the causes of blow-out fractures. The most common cause of blow-out fracture was a slip down in the aged group and violence in the control group (p<0.05). There were no differences in associated symptoms. Extraocular muscle herniation was the only statistically different computed tomography findings. In associated facial bone fractures, the most common fractures were the zygoma in the aged group and the nasal bone in the control group (p<0.05). Conclusion: In patients 60 years of age or older, the most common cause of blow-out fracture was a slip down, and the most common associated facial bone fracture was a zygomatic fracture.

REMARKS ON UNIQUENESS AND BLOW-UP CRITERION TO THE EULER EQUATIONS IN THE GENERALIZED BESOV SPACES

  • Ogawa, Takayoshi;Taniuchi, Yasushi
    • Journal of the Korean Mathematical Society
    • /
    • v.37 no.6
    • /
    • pp.1007-1019
    • /
    • 2000
  • In this paper, we discuss a uniqueness problem for the Cauchy problem of the Euler equation. W give a sufficient condition on the vorticity to show the uniqueness of a class of generalized solution in terms of the generalized solution in terms o the generalized Besov space. The condition allows the iterated logarithmic singularity to the vorticity of the solution. We also discuss the break down (or blow up) condition for a smooth solution to the Euler equation under the related assumption.

  • PDF

RATIONAL HOMOLOGY BALLS IN 2-HANDLEBODIES

  • Park, Heesang;Shin, Dongsoo
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.6
    • /
    • pp.1927-1933
    • /
    • 2017
  • We prove that there are rational homology balls $B_p$ smoothly embedded in the 2-handlebodies associated to certain knots. Furthermore we show that, if we rationally blow up the 2-handlebody along the embedded rational homology ball $B_p$, then the resulting 4-manifold cannot be obtained just by a sequence of ordinary blow ups from the 2-handlebody under a certain mild condition.

Numerical Study to Improve the Flow Uniformity of Blow-Down HVAC Duct System for a Train (전동차용 Blow-Down HVAC 덕트 시스템의 유동 균일도 향상을 위한 수치적 연구)

  • Kim, Joon-Hyung;Rho, Joo-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.18-23
    • /
    • 2016
  • A HVAC(Heating Ventilation and Air Conditioning) is adapted to increase the comfort of the cabin environment for train. The train HVAC duct system has very long duct and many outlets due to the shape of a train set. the duct cross section shape is limited by a roof structure and equipments. Therefore, the pressure distribution and flow uniformity is an important performance indicator for the duct system. In this study, the existing blow down type HVAC duct system for a train was supplemented to improve the flow uniformity by applying a design method combining design of experiment (DOE) with numerical analysis. The design variables and the test sets were selected and the performance for each test set was evaluated using CFD(Computational Fluid Dynamics). The influence of each design variable on the system performance was analysed based on the results of the performance evaluation on the test sets. Furthermore, the optimized model, whose the flow uniformity was improved was produced using the direct optimization(gradient-based method). Finally, the performance of the optimized model was evaluated using numerical analysis, and it was confirmed that its flow uniformity has indeed improved.

The Performance Estimation of Pressure-Type Rapid Automatic Filter (압력식 급속 자동 여과장치의 여과성능 평가)

  • Kim, Deok-Jin;Ryu, Hea-Seong;Shin, Sang-Yoon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.607-612
    • /
    • 2006
  • A pressure-type rapid automatic filter of 2000mm diameter and 170 ton/h filtering capacity was fabricated. In case of no external impurity inflow, the turbidity removal efficiency on raw water was experimented and the numbers of impurities of each sizes were analyzed by particle counter. As the result of circulated filtering, the raw water of 40 NTU was filtered to 0.44 NTU and the numbers of impurities above $1{\mu}m$ were removed by approximately 95%. With the filtering efficiency experimented and the mathematical method, the turbidity change of circulation water were calculated according to the inflow rate of external impurity and water treatment method of blow-down or filtering. The cost of blow-down water was calculated from above results. And simple payback period for this filter is calculated as about one year. Nowadays, as the cost of water is continuously increasing and environment regulations will be more strict, the water quality control using this filter will be expected to satisfy the user requirement.

  • PDF