• Title/Summary/Keyword: Blood-Drawing Method

Search Result 15, Processing Time 0.019 seconds

A Study on Sasang Constitutional Gene Selection Using DNA Chips by Multivariate Analysis (유전자 칩 및 다변량 분석방법을 이용한 사상체질 유전자 선별에 관한 연구)

  • Kim, Pan-Joon;Seo, Eun-Hee;Lee, Jung-Hwan;Ha, Jin-Ho;Choi, Hong-Sik;Jung, Tae-Young;Goo, Deok-Mo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.3
    • /
    • pp.131-144
    • /
    • 2006
  • 1. Objectives This research uses the DNA chip, which includes 16,383 gene code, and various statistic prediction way that shows objectification index for the objectification of constitution diagnosis. 2. Methods Drawing blood whose constitution is confirmed, and analyze its gene information by using 1.7k DNA chip to find the gene correlation through multivariate statistical method. 3. Results and Conclusions Distinctive genes such as AK001919, U09384, NM_001805, X99962, NM_004796, AK026738, AL050148, BC002538, AK027074, AK026219, AF087962, AL390142, NM_015372, AL157466, NM_002446, AK024523, NM_014706, NM_014746 and AL137544 were related to Taeumin; AL157448, NM_005957, NM_005656, NM_017548, AK027246, NM_003025, NM_012302 and NM_005905 were represented in Soeumin, while AK026503, AF147325, NM_002076, AF147307, AK001375, NM_003740, NM_005114, AB007890, NM_005505, NM_015900, NM_014936, Z70694, AB023154, U52076, NM_004360, NM_005835, NM_017528, AF087987, NM_014897, AK021720, NM_006420, AJ277915, AK002118 and AK021918 were for Soyangin. This study figured out the possibility to develop the prediction system by sorting each constitution's gene, and research each constitution's distinctive character of manifestation pattern.

  • PDF

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

A study of using physical body in Contemporary Painting (현대회화에서 신체성의 활용에 관한 연구)

  • Park Ki-Woong
    • Journal of Science of Art and Design
    • /
    • v.6
    • /
    • pp.140-202
    • /
    • 2004
  • Body means 1)the whole structure and substance of a man, animal, or plant 2) the trunk or torso of a man or animal 3) part of garment that covers the trunk 4) the fresh or material substance, as opposed to the spirit. Human body could be distinguished as fresh and spirit. Body has the meaning of physicality. Physical means the bodily and constitution, but in the meaning of constitution there is the content of spirituality. Physicality means the appearing or arising of trace or image or nuance of body. The paintings which are using bodies are 1) directly draw bodies 2) twisting or transformation or nuance of the body and highly upgrade the physical emotion or fantastic bodily nuance 3) directly rubbing artist's body on the surface of painting with pigments to elect tactile specification. These physical art have appeared broadly by various artists, mainly with the social aspects of sex, drug, psycho sexual issues. In case of Joel peter Whitkin, the reason of strong physicality in the art is from the mind of the rejection and resistance of real world which is targeting top, perfect and beauty. Further explanation, being the world which is separated top and under, men and women, beauty and ugly; further in the situation, the hierarchy, terror and pressure began and many difficult problems has derived. The contents of attacking feminists's art works are very obscene to reveal female and male's phallus strongly. Sometime, it is strongly related in the political issues. The physical paintings have strong meanings in the action by hands and feet. It supports that it could reveal the humanity with smell, breath, and traces of bodies. In the bodies, the origin of life begins which gives human life by blood lines and water. Sometime, the physical paintings are made by the blood and urine to stick the physicality for special nuance. The physical paintings are made by the image of penis and clitoris which are related in the image of urinating, ejaculation and sometime is symbolized as pens and candles to drop liquid. The selected painters who are related in physical painting are Jackson Pollock, Andrea Serano, Eve Klein, Francis Bacon, Francesco Clemente, Lichard Long, Jakes & Dinos Chapman, Anselm Kiefer, Kiki Smith and Park, Ki Woong. Francis Bacon's style is destructive in representing human shapes which give us special message about the unbearable activity of men politician, high brain, wealthy and religious people. Francesco Clemente's method is to use throat, ear hole, mouse, clitoris, belly nostrils and every holes of body to transmute human physical body. Lichard Long uses directly his body in drawing the surface of painting by using liquid of mud Jakes & Dinos Chapman destroys or transforms the bodies of human. It sometime appears wrong location of the bodies that the penis and vulva is in between human faces or nose of women, Anselm Kiefer uses human hair for representing the human decaying martyrs, and indirectly using straw, he gives special ritual action to repent the Nazi's fault. From 2002 to 2003, Park KI Woong used women womb images to intermingle the smoke shape of <9.11 terror, 2001> in New York to reveal the painful situation of the time(*).

  • PDF

Multiple Linear Analysis for Generating Parametric Images of Irreversible Radiotracer (비가역 방사성추적자 파라메터 영상을 위한 다중선형분석법)

  • Kim, Su-Jin;Lee, Jae-Sung;Lee, Won-Woo;Kim, Yu-Kyeong;Jang, Sung-June;Son, Kyu-Ri;Kim, Hyo-Cheol;Chung, Jin-Wook;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.317-325
    • /
    • 2007
  • Purpose: Biological parameters can be quantified using dynamic PET data with compartment modeling and Nonlinear Least Square (NLS) estimation. However, the generation of parametric images using the NLS is not appropriate because of the initial value problem and excessive computation time. In irreversible model, Patlak graphical analysis (PGA) has been commonly used as an alternative to the NLS method. In PGA, however, the start time ($t^*$, time where linear phase starts) has to be determined. In this study, we suggest a new Multiple Linear Analysis for irreversible radiotracer (MLAIR) to estimate fluoride bone influx rate (Ki). Methods: $[^{18}F]Fluoride$ dynamic PET scans was acquired for 60 min in three normal mini-pigs. The plasma input curve was derived using blood sampling from the femoral artery. Tissue time-activity curves were measured by drawing region of interests (ROls) on the femur head, vertebra, and muscle. Parametric images of Ki were generated using MLAIR and PGA methods. Result: In ROI analysis, estimated Ki values using MLAIR and PGA method was slightly higher than those of NLS, but the results of MLAIR and PGA were equivalent. Patlak slopes (Ki) were changed with different $t^*$ in low uptake region. Compared with PGA, the quality of parametric image was considerably improved using new method. Conclusion: The results showed that the MLAIR was efficient and robust method for the generation of Ki parametric image from $[^{18}F]Fluoride$ PET. It will be also a good alternative to PGA for the radiotracers with irreversible three compartment model.

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF