• Title/Summary/Keyword: Blood transfusion, Autologous

Search Result 24, Processing Time 0.021 seconds

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 자가 수혈체계[Cell Saver]의 이용 효과)

  • 안욱수
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1312-1317
    • /
    • 1992
  • Autologous blood transfusion is a common method of reducing the need for homologous blood transfusion during cardiac operations. Between June 1991 and May 1992, 12 cases [Group I] were experienced autologous blood transfusion using Cell Saver undergoing double valve replacement or redo-valve replacement. Control group [N=12, Group II] was selected to above similar operation during same period. The Cell Saver system [Haemonetics Corp.] was employed for autologous blood transfusion. The blood shed in the operative field before and after cardiopulmonary bypass and remained cardiotomy reservior was aspirated by means of a locally heparinized collecting system. After centrifused salvaged blood, the resulting red cell concentrate reinfused subsequently. The patient receiving autologous blood transfusion required significantly less homologous blood transfusion than their control group. [Group I; 3519 $\pm$ 869, Group II; 4622 $\pm$ 856, Respectively; P=0.005] There were no clinical infections in the autotransfusion group. And there was no apparent intergroup difference of the clinical findings, hematologio datas and coagulation parameters. We conclude the autotransfusion using Cell Saver is effective for reducing of the hom-ologlous blood transfusion in cardiac surgery.

  • PDF

Use of Predonated Banked Autologous Blood in Open Heart Surgery (개심술시 자가헌혈을 이용한 자가수혈의 효과)

  • 김동관
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.685-692
    • /
    • 1992
  • In spite of multiple technical advances, large amount of homologous blood transfusions usually required for open heart surgery. Because the complications associated with transfusion are increased as the number of homologous transfusion increase, especially as transfusion related acquired immunodeficiency syndrome has appeared in recent years, such risks have stimulated recent interest in the use of autologous blood. This is a report concerning 23 consecutive adult autologous donors[autologous group] who had elective cardiac surgery at the Yonsei Cardiovascular Center, Yonsei University College of Medicine, from march, 1990 to august, 1991. A similar group of 23 patients operated during the same periods without autologous blood donation was used for comparison [control group] to investigate the effect of predonated autologous blood in decreasing the need of homologous transfusion and to investigate predonation related adverse effect. Autologous group consisted of 15 men and 8 women. Control group consisted of 7 men and 16 women. There were no significant differences in mean age, hemoglobin, hematocrit, RBC count, platelet count and prothrombin time on admission between the two groups. The mean autologous blood donation in autologous group was 2.2 units. In 10[43.5%] of the 23 atuologous group patients, no homologous RBC products transfusion was required. However, all patients required homologous transfusion in control group. In autologous group, patients required less homologous RBC products than control patients[2.1 units versus 5.3 units; p<0.001]. There were no significant differences in hemoglobin, hematocrit, RBC count and platelet count between the two groups before discharge. There were no serious complications related to preoperative blood donation, although 3 patients complained of mild dizziness during donation We conclude that preoperative autologous predonation of blood is a safe and effective method for reducing homologous transfusion and is recomended in all patients undergoing elective cardiac surgery except limited contraindications such as severe aortic valve stenosis or unstable angina pectoris.

  • PDF

A CLINICAL STUDY OF THE BLOOD LOSS AND TRANSFUSION ON ORTHOGNATHIC SURGER (악교정 수술시 출혈량과 수혈에 관한 임상적 연구)

  • Bae, Jun-Soo;Lyoo, Jong-Ho;You, Jun-Young;Kim, Yong-Kwan;Shin, Dong-Yong;Lee, Chang-Sun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.300-304
    • /
    • 1998
  • Moderns have desire likely to be further good-looking concomitant with a qualitative advancement of the life. With one of this phenomenon, an orthognathic surgery performing at the dept. of oral and maxillofacial surgery have been becoming a more extensively. It's possible to occur many complications during the operations and especially, an excessive bleeding of those may be fatal and so a transfusion is performing for the prevention &management of that. But, because of the rate of increase of an blood-born infection like AIDS via transfusion, nowadays an autologous blood transfusion is interesting to us. We made a comparative study of an amount of blood loss &transfusion using hemoglobin value after classifying the orthognathic surgeries from Feb. '97 to Mar. '98 in single-jaw and doublejaw surgery. And we intended to set a standard against of a routine preoperative cross-matching deciding the amount of predictive homologous blood transfusion according to operative method. Simultaneously, we studied the realization &effectiveness of autologous blood transfusion with some cases, so would like to present. Results: 1. Single-jaw operation can be performed without blood transfusion or with homologous blood transfusion through only blood typing & screening. 2. We commonly transfuse two units of blood with double-jaw operation and an autologous blood transfusion has much more advantage than an homologous blood transfusion. 3. We can reduce charge associated with blood transfusion through precisely preoperative evaluation of patients and proper type of blood transfusion.

  • PDF

Influence of Autologous and Homologous Blood Transfusion on Interleukins and Tumor Necrosis Factor-α in Peri-operative Patients with Esophageal Cancer

  • Xing, Yue-Li;Wang, Yan-Chun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7831-7834
    • /
    • 2014
  • Objective: To explore the influence of different ways of blood transfusion on the expression levels of interleukins (IL) and tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) inperi-operative patients with esophageal cancer. Materials and Methods: A total of 80 patients with esophageal cancer who underwent radical operations were selected as study patients and randomly divided into an observation group (treated with autologous blood transfusion) and control group (with homologous blood transfusion). Changes of intra-operative indexes and peri-operative blood indexes, from hemoglobin (Hb) and hematocrit value (Hct), to levels of inflammatory factors like interleukins-6 (IL-6), IL-8, IL-10 and tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) were compared. Results: Operations for patients in both groups were successfully conducted, and no significant differences in mean surgical duration and intra-operative hemorrhage volume, fluid infusion volume and blood transfusion volume were detected (p>0.05). Compared with values before surgery, Hb and Hct levels decreased significantly while white blood cell count (WBC) increased 1, 5 and 7 d after operation (p<0.05, p<0.01). In addition, WBC was apparently higher in observation group than in control group 5 and 7 d after operation (p<0.01). Compared with before surgery, in the observation group, levels of IL-6, IL-8 and IL-10 had no significant differences after operation (P>0.05), but TNF-${\alpha}$ level increased y (p<0.01), whereas in control group, IL-6 level had no significant difference (p>0.05), IL-8 level decreased obviously (p<0.05), IL-10 level increased markedly first and then decreased gradually as time passed but its level remained elevated (p<0.01), and TNF-${\alpha}$ level increased first and then decreased, and there was no significant difference 7 d after operation (p>0.05). Conclusions: Decreased IL-8 and increased IL-10 levels are two important reasons for immunosuppression after homologous blood transfusion, whereas autologous blood transfusion can alleviate this while increasing the TNF-${\alpha}$ level, which also has potential to improve anti-tumor immunity in the human body.

Autologous Transfusion in Pregnant Women with Significant Risk for Hemorrhage (출혈위험 임산부에서의 자가수혈)

  • Kim, Gee-Deuk;Bae, Chul-Sung;Park, Yoon-Kee;Kim, Jong-Wook;Koh, Min-Whan;Lee, Sung-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.95-103
    • /
    • 1990
  • Autologous transfusion, storage of one's own blood for subsequent infusion if needed, is safe and effective in a variety of scheduled operative procedures. Obstetric involvement in such programs is very limited, however, because of concern over the possibility of inducing premature labor or causing fetal distress by blood volume change or vasovagal reactions. We describe our experience with pregnant women in this program. The incidence of vagovagal reactions of autologous donation was 9.5% (2/21). After entry into this program, 17pastients received a total 37pints, which consist of 19 Autologous and 18 Homologous. Homologous transfusion was avoided in 30% of patients receiving blood. The values of the mean haematocrits before and after hpebotomy were 34.1 % and 31.8 % respectively. It was statically significant(p<0.01). We recommended that autologous blood donation by pregnant women in third trimester is safe for mothers or infants and it should be strongly encouraged for patient with placenta previa and repeated cesarean section.

  • PDF

Autotransfusion Using Ccell Saver in Cardiac Surgery (개심술에서의 자가수혈기(Cell Saver)를 이용한 자가수혈)

  • 육을수
    • Journal of Chest Surgery
    • /
    • v.28 no.2
    • /
    • pp.125-130
    • /
    • 1995
  • Autotransfusion system is a common method of reducing the need of intraoperative and postoperative homologous blood transfusion in cardiac operation. Between August 1991 and August 1993, a series of 51 adults undergoing open heart surgery was selected. Autotransfusion using Cell Saver [COBE Baylor Rapid Autologous Transfusion System was done with homologous blood transfusion in 15 cases [Group II or without homologous blood transfusion in 17 cases [Group III . The other 19 cases were taken without Cell Saver for control [Group I . The shed blood in the operative field, remained blood in the oxygenator after cardiopulmonary bypass, and blood drained from chest tubes in postoperative care were aspirated by means of a locally heparinized collection system. After the salvaged blood was washed and centrifuged, the processed blood subsequently reinfused. Composition of processed blood by Cell Saver was hemoglobin 16.9gm%, hematocrit 49%, RBC 5,140,000/ml, WBC 670/ml, and platelet 30,000/ml. In three group, hemoglobin, hematocrit, and platelet counts were decreased postoperatively, but no significant differences between three group. Postoperatively, the amounts of drainage from chest tubes was 543$\pm$121ml in Group I, 809$\pm$201ml in Group II, and 631$\pm$147ml in Group III. In Group II, there was large amount of drainage compared with Group I [p<0.05 . The amount of homologous blood transfused was 1116$\pm$219 ml in Group I, 791$\pm$183 ml in Group II [p<0.05 . The homologous blood was not transfused in 17 cases [53% with Cell Saver.Preoperative and postoperative, coagulation parameters showed no significant differences between three group. And there was no complication related to Cell Saver. We conclude that the autotransfusion using Cell Saver is effective for reducing the homologous blood transfusion in cardiac surgery.

  • PDF

Intraoperative and Postoperative Blood Conservation in Cardiac Surgery (수술중 및 수술후 혈액보존법)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.451-454
    • /
    • 1994
  • In February 1991 I initiated a blood conservation program that included hemodilution, use of a cell conservation device to concentrate diluted blood from operative field and from mediastinal shed blood, acceptance of a minimal hematocrit level of 25% in stable patients, and strict avoidance of use of blood products without definitive indication. A retrospective study to evaluate the effects of blood conservation program was designed to compare the amount of homologous transfusion, hematologic data, and postoperative outcome in patients operated on before and after initiation of blood conservation program. Patient characteristics were not different between two groups, before[n = 18] and after[n = 42] initiation of the program. The significant decrease of homologous transfusion[5.2 vs 1.4 units] and the marked increase of nontransfused patients[none vs 57%] in experimental group were due to marked decrease in homologous transfusion during the operation[4.6 vs 0.7 unit]. I conclude that with strict intraoperative blood conservation program, cardiac patients can be operated on with minimal homologous transfusion.

  • PDF

A HEMATOLOGIC STUDY OF ORTHOGNATHIC SURGERY PATIENTS (악교정 수술후 혈액학적 변화에 대한 연구)

  • Lee, Jong-Seok;Ko, Seung-O;Jeong, Kil-Jung;Leem, Dae-Ho;Baek, Jin-A;Shin, Hyo-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.2
    • /
    • pp.157-166
    • /
    • 2007
  • Moderns have desire likely to be further good-looking concomitant with a qulitative advancement of the life. Orthognathic surgery for the correction of dentofacial deformities is a common elective procedure. It's possible to occur many complication during the operations and especially, an excessive bleeding of those may be fatal and so a tranfusion is performing for the prevention and management of that. The most notable of these for reduction of blood loss is the utilization of induced hypotensive anesthetic technique to reduce the mean arterial pressure between 55 and 60 mmHb. Another method for dealing with blood loss following orthognathic surgery is the transfusion of blood obtained as an autologous tranfusion or from banked blood. Some of the disadvantage of banked blood are overcome with the use of predeposited autologous transfusion. But currently, surgeons try so that even autologous transfusion may not transfuse the patients. We made a comparative study of hematologic change and transfusion requirement based on a series of 200 patients who had an orthognathic surgical procedure at Chonbuk National University during the period 2001-2005. This study is to make a comparative analysis of an post-operative hematologic (Hemoglobin, Hematocrit, Red blood cell) change and duration of the procedure under induced hypotensive anesthesia in healthy orthognathic patients.

AVAILABILITY OF AUTOLOGOUS TRANSFUSION IN BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY FOR MANDIBULAR PROGNATHISM (하악전돌증 환자의 하악지 시상분할 골절단술에서 자가수혈의 유용성)

  • Han, Sang-Jeong;Zang, Ju-Min;Oh, Han-Seok;Lee, Hae-Kyung;Lee, Jeong-Nyeo;Lee, Su-Woon;Park, Sang-Jun;Kim, Woo-Hyung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.524-529
    • /
    • 2007
  • Objective: Autologous transfusion is frequently used with orthognathic surgery. The necessity of autologous transfusion has begun to question alone in bilateral sagittal split ramus osteotomy. The aim of this study was to evaluate the availability of autologous transfusion. Methods: The chart reviews of sixty patients who had undergone bilateral sagittal ramus osteotomy were done. The subjects were divided into two groups: In experimental group, 30 patients who autodonated 320ml in the preoperative 3 weeks actually received a transfusion in the postoperative 6 hours were included. In control group, 30 patients who underwent the same operation without preoperative donation and any other transfusion were included. Hemoglobin, hematocrit, and changes of these values in both groups were evaluated. Results: 1. From postoperative 3 hours to postoperative 1 day, the increases of hemoglobin(0.8g/dL in experimental group, 0.2g/dL in control group) and hematocrit(0.3% in experimental group, 0.6% in control group) were not statistically significant between both groups. 2. From postoperative 1 day to postoperative 1 week, the increase of hemoglobin(0.6g/dL in experimental group, 0.3g/dL in control group) was not statistically significant between both groups. But the increase of hematocrit(2.5% in experimental group, 1.0% in control group) was statistically significant between both groups over the same period(hematocrit p=0.043). 3. On postoperative 1 week, the values of hemoglobin(12.3% in both groups) and hematocrit(35.6% in experimental group, 36.8% in control group) were not statistically significant between both groups. Conclusion: The autologous transfusion in surgery of just a little blood loss was not effective. The most results show that there is little availability of autologous transfusion according to changes of hemoglobin and hematocrit in bilateral sagittal split ramus osteotomy.

Open Heart Surgery without Transfusion (수혈 없이 시행한 개심술)

  • Kim, Kun-Il;Lee, Weon-Yong;Kim, Hyoung-Soo;Kim, Shin
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.184-192
    • /
    • 2009
  • Background: Although complications from transfusion are known to happen, transfusion is performed during most open heart surgeries. The aim of this study was to investigate the possibility of performing cardiac surgery without allogenic blood transfusion. Material and Method: Between January to August 2007, 44 consecutive patients who underwent open heart surgery with using various blood conservation methods were retrospectively enrolled. They were divided into group I (the onpump group, n=17) and group II (the offpump group, n=27). The blood conservation methods were intraoperative autologous donation, cell saver, retrograde autologous priming, conventional ultrafiltration and modified ultrafiltration. Antianemic agents were administered to all the patients postoperatively. We analyzed the possibility of bloodless operations, the causes of homologous transfusion, the serial change of the hematocrit and the postoperative chest tube drainage, and we compared the results between the two groups. If comparison between the two groups was not reasonable, then we compared two groups with the individual control groups I and II (49 patients) in 2006. Result: 40 (90.9%) of 44 patients were successfully operated on without transfusion and the success rate was 88.2% (15/17) for group I and 92.6% (25/27) for group II. There was no statistical difference between the two groups (p=NS). The causes of transfusion were 2 cases of postoperative bleedings, 1 case of intraoperative bleeding and 1 mistake of the indication for transfusion. There was no statistical difference of the total chest tube drainage (Group I: $417{\pm}359mL$, Group II: $451{\pm}237mL$) (p=NS), but the total chest tube drainages of the two groups were less than each of the control groups 1 and II (p<0.05). The lowest hematocrit level of Group I was $16.4{\pm}2%$, and this occurred just after infusion of cardioplegics and the hematocrits of both groups were recovered to the preoperative level at 2 months postoperatively. Conclusion: In this study, bloodless open heart surgery could be performed in 90.9% of the patients with intraoperative autologous donation, cell saver, retrograde autologous priming, conventional ultrafiltration and modified ultrafiltration. A combination of various blood conservation methods is the most important and bloodless cardiac surgery could be performed with meticulous bleeding control and strictly following the transfusion indications.