• 제목/요약/키워드: Blood pressure measurement

검색결과 401건 처리시간 0.029초

고혈압 건강진단의 비용분석 (Cost analysis of hypertension screening program)

  • 박은철;유승흠
    • Journal of Preventive Medicine and Public Health
    • /
    • 제22권3호
    • /
    • pp.380-388
    • /
    • 1989
  • To evaluate the costs of the hypertension screening program of the Korea Medical Insurance Corporation, the records of the screening examinations were used. The sample size was 49,983 of the 906,554 people insured by the Corporation and was obtained by two-stage stratification random sampling. The alternatives for efficiency of the screening program, which were divided into three categories : modification of the screening test package, application of other hypertension diagnostic criteria, and selective approach of tested groups by age, were evaluated according to the cost per patient detected. The results of this study were as follows In the hypertension screening system, the cost per patient detected was Won 30,883. The most nonsensitive test for hypertension detection was ophthalmoscopy, which was examined during the second stage of screening. If the ophthalmoscope examination was excluded, olny one person was not detected, which was 0.2% of detected persons, and the cost per patient detected decreased to Won 28,098. The most efficient modification of the screening test package was measurement of blood pressure through the first and second stages of screening. The cost per patient detected by this modification was Won 24,408. The application of other diagnostic critera, which were more restricted criteria, increased the cost per patient detected by 3.7%-6.7%. The cost per patient detected were Won 170,582 for persons less than 39 years old, Won 20,032 for persons 40 to 59 years old, and Won 8,675 for persons 60 years old and over. In conclusion, the best alternative suggested with respect to efficiency and practical application excluded the ophthalmoscope examination of second stage screening and restricted the target population to persons greater than 40 years old. The application of this alternative decreased 54.9% of the screening costs and the cost per patient detected was Won 15,222. This study was limited in that measurement of effectivenes was not of the ultimate goal of screening, which is decreasing morbidity and mortality, but was of disease detection as the short-term objective.

  • PDF

헬스 케어를 위한 무선 모니터링 시스템 구현 (An Implementation of Wireless Monitoring System for Health Care)

  • 엄상희;장용훈
    • 한국정보통신학회논문지
    • /
    • 제12권8호
    • /
    • pp.1401-1407
    • /
    • 2008
  • 최근 고령 인구의 증가에 따른 헬스 케어 수요가 증가하고 있고 환자뿐만 아니라 일반인들에게서도 헬스 케어 모니터링에 대한 요구가 급증하고 있다. 또한 의료 서비스를 제공받으려는 대상자의 불편을 최소화하고, 지속적인 모니터링을 통한 헬스 케어가 가능할 수 있는 의료 기술과 의료 정보 서비스에 대한 수요도 늘어나고 있는 추세이다. 본 논문에서는 헬스 케어를 위한 무선 생체신호 모니터링 시스템을 구현하였다. 구현된 시스템은 생체신호 측 정부와 무선 통신부로 구성된 센서 노드(sensor node)와 원격 시스템의 모니터링 프로그램으로 구성된다. 센서 노드에서는 심전도, 혈압, 맥파, 동맥혈산소포화도, 심박수를 측정할 수 있고 블루투스 기술을 이용하여 무선 전송을 하여 모니터링 시스템에서 실시간 무선 모니터링이 가능하도록 구현하였다.

IoT 스마트 스트레스 케어를 위한 생체신호 기반의 실시간 HRV 측정 (Development of Real-time HRV measurement Application based on vital signs for IoT smart stress care)

  • 송호준;박도영
    • Journal of Platform Technology
    • /
    • 제9권1호
    • /
    • pp.40-45
    • /
    • 2021
  • COVID-19 펜데믹으로 인하여 우리의 일상은 많은 변화를 가지고 왔다. 이로 인한 사회적거리두기와 같은 공중보건 조치로 인하여 COVID-19의 확장을 줄이는 데는 필수적이나, 동시에 우울증, 불안장애, 우울장애, 외상 및 스트레스 관련 장애 등에 노출이 되고 있다. 본 논문에서는 생체신호를 실시간으로 측정이 가능한 Smart Watch 디바이스를 기반으로 한 ECG와 PPG 측정을 통하여 HRV 데이터 및 스트레스 지수 확인이 가능한 Application을 개발하였다. 개발된 Application의 경우 실시간으로 Heart Rate를 측정하여 표시 하였으며, 걸음 수와 칼로리, 총 운동 거리를 측정하여 기본적인 운동정보를 전달하였고, 측정하기 프로그램으로 혈압, 심박수, HRV 데이터를 블루투스 기반으로 원활히 전달 하였다. 이를 통해 스스로 정신건강 관리를 할 수 있는 IoT 스마트 스트레스 케어 Application이 스트레스 및 우울 외상 장애 환자에게 도움이 될 것이라 생각한다.

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

중증외상환자의 주 손상 부위별 특성과 간호활동 (Characteristics and Nursing Activities of Severe Trauma Patients Regarding the Main Damaged Body Parts)

  • 김명희;김명희;박정하
    • Journal of Korean Biological Nursing Science
    • /
    • 제15권4호
    • /
    • pp.210-218
    • /
    • 2013
  • Purpose: The purpose of this study was to identify the characteristics and nursing activities of severe trauma patients regarding damaged body parts in Busan Regional Emergency Medical Center. Methods: A survey using a 'trauma patient information questionnaire and a list of nurse activities' was conducted with 133 patients over 15 points ISS on EMR from June 1, 2011 to May 31, 2012. The collected data were analyzed by the SPSS/WIN 12.0 program. Results: Almost all of the subjects were men, and the mean age was 48.8. The amount of road traffic accidents was 60.4%, and the mean RTS and ISS were 6.08, and 23.14 points. Nursing activities in common were airway management, assessment of LOC & GCS, and EKG monitoring. Most of head and neck trauma patients were cared for manasing using intracranial pressure: each patience had the following assessed: pupil size and light reflex, they were checked the leak of CSF, kept $30^{\circ}$ head elevation, and administered medications. Some of chest trauma patients were treated for chest tube and central venous catheter insertion. Partial abdominal trauma patients were administered analgesic and cared for using arterial pressure measurement. Part of the limbs and pelvis trauma patients were given a blood transfusion. Conclusion: Based on the results, the characteristics and nursing activities were specific according to the specific damaged body parts.

Utility of Toe-brachial Index for Diagnosis of Peripheral Artery Disease

  • Park, Seong-Chul;Choi, Chang-Yong;Ha, Young-In;Yang, Hyung-Eun
    • Archives of Plastic Surgery
    • /
    • 제39권3호
    • /
    • pp.227-231
    • /
    • 2012
  • Background : The ankle brachial pressure index (ABI) is a simple, useful method for diagnosing peripheral artery disease (PAD). Although the ABI is an objective diagnostic method, it has limited reliability in certain scenarios. The aim of the present study was to determine the accuracy and reliability of the toe brachial index (TBI) as a diagnostic tool for detecting stenosis in PAD, associated with normal or low ABI values. Methods : ABI and TBI values were measured in 15 patients with diabetic gangrene who were suspected of having lower extremity arterial insufficiency. The ABI and TBI values were measured using a device that allowed the simultaneous measurement of systolic blood pressure in the upper and lower extremities. In addition, the ABI and TBI values were compared pre- and post-angiography. Results : Patients with an ABI of 0.9-1.3 showed almost no difference between the 2 measurements. The patients with TBI >0.6 had no arterial insufficiency. The patients with TBI <0.6 required vascular intervention with ballooning. After the angiography, the gangrenous wounds decreased in size more rapidly than they did prior to the intervention. Conclusions : Our findings suggest that TBI is the method of choice for evaluating lower limb perfusion disorders. This result requires further studies of TBI in a larger number of patients. Future long-term studies should therefore evaluate the utility of TBI as a means of screening for PAD and the present findings should be regarded as preliminary outcomes.

동맥경화 평가를 위한 연령별 맥파 주요인자 분석 (Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation)

  • 이나라;이승욱;김수병;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제28권4호
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

채식 성인여성의 식사형태 및 비타민, 영양제 복용과 혈중 지질, 혈당, 혈압과의 관련성에 관한 비교연구 (The Study of the Diet Style and Relationships among Vitamin and Nutrient Supplement Intakes, Serum Lipid Levels, Blood Sugar and Blood Pressure of Adult Female)

  • 차복경;최원경
    • 한국식품영양과학회지
    • /
    • 제31권2호
    • /
    • pp.306-314
    • /
    • 2002
  • 조사대상자의 평균나이는 채식인 44.2세, 비채식인 40.5세, BMI는 각각 22.4, 21.0이었고, WHR은 0.8, 0.8였고, %BF는 28.7, 26.5였으며, 채식인의 평균채식기간은 13.1년이었다. 조사대상자중 비만인 사람의 식사 형태는 채식인은 볼륨형(58.8 %), 미식가형(20.6%), 다이어트형(8.8%), 패스트푸드형 (5.9%), 밸런스형(5.9%)의 순이었고 비채식인은 미식가형(33.3%), 볼륨형 (27.8%), 다이어트형 (16.7%), 패스트푸드형 (11.1%), 밸런스형(11.1%)의 순이었다. 채식인은 식사의 양이 많은 사람에게서 비채식인은 미식가형에서 비만이 많은 것으로 나타났다. 정상체중인 사람의 식사형태는 책식인은 볼륨형(45.1 %), 미식가형 (32.4%), 밸런스형 (16.2%), 다이어트형 (4.2%), 패스트푸드형 (2.1%)의 순으로 볼륨형과 미식가형이 약 78% 정도를 차지하였다. 비채식인은 볼률형(34.2%), 미식가형(26.1 %), 패스트푸드형 (22.6%), 밸런스형 (10.6%), 다이어트형 (6.5 %)의 순으로 의외로 볼륨형이 가장 많았다. 조사대상자의 평균 중성지방은 채식인 136.7 mg/dL, 비채식인 130.5 mg/dL 였고, total-cholesterol은 채식인 161.4 mg/dL, 비채식인 189.6 mg/dL, HDL-cholesterol은 채식인 48.2 mg/dL, 비채식인 50.8 mg/dL, LDL-cholesterol은 채식인 86.6 mg/dL, 비채식인 111.1 mg/dL, AI는 채식인 2.4, 비채식인 2.9, 혈당은 채식인 90.8 mg/dL, 비채식인 103.6 mg/dL, 수축기 혈압은 채식인 107.5 mmHg, 비채식인 119.3 mmHg, 이완기혈압은 채식인 72.4 mmHg, 비채식인 73.6 mmHg이었다. 조사대상자의 total-cholesterol, LDL-cholesterol, HDL-cholesterol, AI, 수축기혈압 및 혈당은 비채식인이 유의적으로(p<0.05) 높았으며, 심혈관질환 예견지수인 HDL-cholesterol/total-cholesterol 비는 채식인이 유의적으로(p<0.05) 높았다. 조사 대상자의 비타민 및 영양제 복용실태는 비타민을 복용한다고 한 사람은 채식인 53명(22.6%), 비채식인 71명 (29.0%), 영양제를 복용한다고 한 사람은 채식인 24명(10.2%), 비채식인 15명 (11.0%), 비타민이나 영양제를 먹지 않는다고 한 사람은 채식인 158명(67.2%), 비채식인 147명(60.0%)으로 두 군이 비슷한 비율이었다.

건물 계단 이용에 따른 심폐기능의 변화 (Variation of Cardiopulmonary Function by Use of Building Stairs)

  • 이승주
    • 대한물리치료과학회지
    • /
    • 제3권2호
    • /
    • pp.989-995
    • /
    • 1996
  • 본 연구는 건물 계단을 올라감에 따른 심폐기능의 변화를 알아보기 위해 안동전문대학 물리치료과에 재학 중인 1, 2, 3학년 학생 총 136명 중 50명을 무작위로 추출하여 1995년 9월 20일에서 10월 3일까지 14일간 조사된 연구의 분석결과는 다음과 같다. 1. 연구대상자의 일반적인 특성 중 신장은 평균 166.4cm, 체중은 57.7kg이었다. 2. 안정시 수축기혈압은 평균 121.3mmHg, 이완기 혈압은 78.5 mmHg였다. 3. 안정시 맥박수는 평균 71.8회, 호흡수는 20.4회, 체온은 $36.8^{\circ}C$였다. 각 층에서 심폐기능의 변화를 파악하기 위해 분산분석을 실시한 결과는 다음과 같다. 1. 측정 후 2, 3, 4충간의 수축기혈압은 각각 129.0 mmHg, 127.0 mmHg, 132.0 mmHg로 3층에서는 약간 낮았으나 점차 증가하였고 (P=0.1919), 이완기혈압도 80.1mmHg, 76.5mmHg, 82.0 mmHg로 3층에서 약간 낮은 후 점차 증가하였으나 통계적 차이는 없었다(P=0.4229). 2. 맥박수는 2, 3, 4층에서 각각 74.0회, 73.1 회, 74.0회로 충간의 뚜렷한 차이가 없었다(P = 0.8148). 3. 호흡수는 2, 3, 4층에서 21.4회, 23.1회, 24.6회로 층수가 높아짐에 따라 횟수가 증가하여 통계적으로 유의한 차이를 보였다(P = 0.0071). 4. 체온은 2, 3, 4층에서 36.8, 36.6, $36.5^{\circ}C$로 통계적으로 유의하게 낮아짐을 나타내었다(P=0.0040). 따라서 본 연구결과에 의하면 건물의 계단을 올라감에 따라 호흡수는 증가하였고, 체온은 낮아짐을 알 수 있었다. 그래서 중추신경계환자 및 노약자들은 이 점을 의식해야 될 것으로 사료되며, 본 연구는 정상인을 대상으로 측정을 실시하였지만 향후 환자를 대상으로 한 연구가 요구된다.

  • PDF

u-EMS : 바이오 센서 네트워크 기반의 응급 구조 시스템 (u-EMS : An Emergency Medical Service based on Ubiquitous Sensor Network using Bio-Sensors)

  • 김홍규;문승진
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제13권7호
    • /
    • pp.433-441
    • /
    • 2007
  • 바이오센서는 생명공학 또는 의학 분야에서 사용되는 인간의 생체 신호를 감지할 수 있는 센서들로 의료기기에 주로 사용되는데, 최근 MEMS 기술의 발달로 작은 크기의 하드웨어에 센서 인터페이스, 프로세서, 무선통신, 배터리 등을 포함한 모듈을 센서노드(모트 : Mote)들로 구성된 센서기반 네트워크에서 바이오센서 네트워크로 응용분야를 확장하고 있다. 이에 본 논문에서는 바이오센서 기술과 센서네트워크 기술을 융합한 기술인 바이오 센서네트워크를 활용한 응급 구조 시스템의 설계 및 구현을 제안한다. 제안된 시스템에 사용된 바이오센서는 근전도(EKG), 혈압(Blood Pressure), 맥박(Heart Rate), 산소포화도(Pulse Oximeter), 혈당(Glucose)센서들로, 바이오센서에서 측정된 생체 신호를 센서네트워크 모트를 통해 데이타를 수집하고, 수집된 데이타를 이용하여 건강관리 측정 데이타로 활용하였으며 측정된 데이터는 무선단말기(PDA, 휴대폰), 전자액자 디스플레이장치 등에서 확인 가능하도록 구성하였다. 아울러, 제안한 u- 응급 구조 시스템의 유효성을 실험하기 위해서 사용자의 바이탈사인 정보와 주변 환경정보를 고려한 실험을 수행하였다.