• 제목/요약/키워드: Blood pressure measurement

검색결과 401건 처리시간 0.024초

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

30~60대 여성의 골밀도와 비만도, 폐경, 혈압, 식생활 관련 요인 분석 (Analysis of BMI Menopose, Blood Pressure and Dietary Habits Affecting Born Mineral Density of 30~60 Years Women)

  • 구재옥;박서연
    • 대한지역사회영양학회지
    • /
    • 제15권3호
    • /
    • pp.403-414
    • /
    • 2010
  • Reducing women's bone mineral density (BMD) has close relationship to risk in osteoporosis. This study was carried out to identify bone density risk factors affecting women's BMD, and to analyze the relationship of age, between BMD and menopause, BMI, blood pressure lifestyle and dietary habits for bone health by physical measurement and questionnaires. The study subjects, 128 women living in Seoul, were divided into 4 age group; 30~39 years (17), 40~49 years (54) and 50~59 years (36) and 60~69 years (21). There were significant differences in mean height, BMI, systolic blood pressure, menache and menopause age and menopause ratio and BMD T-score among the 4 age groups. BHD was significantly decreased according to increasing age and BMI and menopause. The rate of BMD risk subjects was significantly different increasing with age and BMI. The rate of risk group were 0%, 13%, 22.2% and 71.4%, by age groups and 0%, 16.2%, 33.3% and 52.9% by BMI respectively. BMD of menopause groups was significantly decreased from 1.23 (40 years) to 1.34 (60 years). p < 0.001. Also systolic blood pressure were significantly increased from 116.5 mmHg (30 years) to 130.81 mmHg (60 years). The T-score of normal group also decreased significantly from 1.27 to 0.13 (60years) with age. There were significant negative correlation between BMD and age (r = -0.409) menopause (r = -0.346), BMI (r = -0.218) systolic blood pressure (r = -0.193), salty taste eating out (r = -0.185) (p < 0.05). There were significant positive correlation between BMD and meat fish and walking time. In conclusion, bone density decreased with age. Most of the 50 years' subjects were in risk group. BMI, menopause, systolic blood pressure, frequency alcohol consuming. To prevent osteoporosis, over 40 years needed to be educated to maintain normal weight and the improvement of eating and living habits.

한국인혈압(韓國人血壓)의 정상치역(正常値域) (Normal Range of Blood Pressure of Korean)

  • 김인달;안윤옥;조수헌
    • Journal of Preventive Medicine and Public Health
    • /
    • 제7권2호
    • /
    • pp.395-401
    • /
    • 1974
  • In order to figure out the normal range, lower limit of hypertension and upper limit of hypotension of the blood pressure of Korean, authors had measured blood pressure according to Korotkow's method for 31,897 healthy persons as samples who were occupied different levels of the social class except cases who would seem to be the essential hypertension and had the diseases affecting to secondary hypertension. A following conclusion was induced by actual measurement and statistical reasoning. 1. The normal range and limits of hypo- and hypertension by sex and age groups of Korean were demonstrated in Table 1 and Figure 1. 2. The more aging the higher value of blood pressure in both sexes, especially women rather than men and systolic as to diastolic. 3. Generally, blood pressure values of female were lower than male, after 55 years of age, however, the crossing phenomenon was recognizable. 4. To settle the normal and abnormal ranges of the blood pressure of Korean, it was attempted that $M{\pm}1.282{\sigma}$ as normal range, $M+2{\sigma}$ as lower limit of hypertension and $M-2{\sigma}$ as upper limit of hypotension were calculated, and regression lines were drawn to adjust the biological variables and derive continuity from each age class. (Fig. 2 and 3) 5. The blood pressure levels were becoming elevated as to getting increased of the body weight, particularly diastolic value at 40-49 age group in male and systolic value at 30-39 age group in female.

  • PDF

맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발 (Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity)

  • 최정현;조욱현;박준호;김남훈;성향숙;조종만
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

삼소음(蔘蘇飮)이 백서(白鼠)의 국소뇌혈류량(局所腦血流量)과 혈압(血壓)에 미치는 영향(影響) (The Effects of Samsoeum Extracts on Regional Cerebral Blood Flow and Blood Pressure in Mice)

  • 박병민;홍재의;고영철;신조영;이시형
    • 대한한방내과학회지
    • /
    • 제23권1호
    • /
    • pp.33-39
    • /
    • 2002
  • Objective : The objective of this study is to measure the changes of regional cerebral blood flow(rCBF) and blood pressure(BP) in rats with the following injection. Methods : The measurement was continually monitored by laser-doppler flowmeter-Transonic Instrument, USA- and pressure tranducer(Grass, USA) in anesthetized adult Sprague-Dawley rats about for two hour to two hour and a half hours through the data acquisition system composed of Maclab and Macintosh computer. Result : This experiment with Samso-eum increased the changes of rCBF in rats, significantly, but did not change the blood pressure. The rCBF of Samso-eum decreased by pretreated propranolol, and was not changed by pretreated L-NNA and ODQ. Conclusion : It is considered that the dosage-dependent increase on rCBF is mediated by adrenegic ${\beta}$-receptor.

  • PDF

유비쿼터스 혈압 측정 시스템의 설계 및 구현 (Design and Implementation of ubiquitous blood pressure measurement system)

  • 김정원
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권6호
    • /
    • pp.143-150
    • /
    • 2006
  • 본 논문에서는 인체의 혈압을 측정하여 언제 어디서나 환자의 건강상태를 체크할 수 있는 유비쿼터스 헬스 케어 시스템을 구현하였다. 구현된 시스템은 혈압 측정 단말기 자료 수집 베이스 노드, 의료 정보 수집 서버로 구성된다. 구현된 단말기는 지그비(Zigbee) 프로토콜을 통하여 센스 네트워크를 구성하며 TinyOS가 내장되어 있는 초소형 보드로 설계되었다. 자료 수집 베이스 노드는 무선 리눅스 단말기로 구성되어 서버로 무선 랜을 통하여 센싱된 정보를 실시간으로 전송한다. 또한 의료 정보 수집 서버는 단말기에서 얻은 데이터를 저장 관리하며 긴급 상황 발생 시 연계된 의료진에게 환자의 상태를 보고하도록 설계되었다. 실험 결과 지그비 통신 프로토콜을 이용한 센스 네트워크를 통하여 유비궈터스 헬스 케어 시스템이 구현 가능함을 확인하였다.

  • PDF

광센서와 압력센서를 이용한 맥박측정시스템 개발 (Development of Blood Pressure Measuring System using piezoelectric and photo sensor)

  • 최영숙;김경재;홍우헌;류정탁
    • 한국산업정보학회논문지
    • /
    • 제14권5호
    • /
    • pp.149-154
    • /
    • 2009
  • 사람들의 평균 수명이 늘어남으로써 건강에 대한 관심도가 매우 높아지고 있다. 그에 따라 사람들은 자신의 몸 상태를 체크하며 주기적으로 자신의 건강상태를 확인하기 위해 정기검진을 받는다. 그러나 평소 자신의 맥박이나 혈압의 체크를 통하여 건강관리 및 질병예방이 가능하다. 따라서 본 논문에서는 간편하게 얻을 수 있으면서도 기본적이고 유용한 정보를 많이 가지고 있는 맥박신호를 혈액량에 따라 투과율의 변화를 측정할 수 있는 광센서를 이용한 방법과 압전 센서를 사용하여 손목의 요골동맥의 압력을 측정하여 맥박을 측정할 수 있는 휴대용 맥박측정 시스템을 구현하였으며 두 방법으로 제작된 시스템을 비교연구 하였다.

맥파전달시간을 이용한 동맥혈 혈압측정 (Arterial blood pressure measurement using pulse transit time)

  • 황대석;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.265-267
    • /
    • 2007
  • 고혈압을 진단하고 치료함에 있어 정기적인 혈압의 측정 및 관리는 매우 중요하다. 본 논문에서는 요골 동맥혈에서 혈압 측정을 하기 위한 심전도 측정기와 광용적맥파 측정기를 설계하여 구성하였으며, 이를 이용한 맥파 전달 시간 측정을 LA(Left Arm), RA(Right Arm)에서 심전도와 요골동맥에서 광 용적맥파 신호를 측정하였다.

  • PDF

PPG 맥파 분석의 PTT 측정변화에 따른 SBP, DBP 추정 융합 알고리즘 변화율 분석 (Analysis of Change Rate of SBP and DBP Estimation Fusion Algorithm According to PTT Measurement change PPG Pulse Wave Analysis)

  • 김선칠
    • 한국융합학회논문지
    • /
    • 제11권7호
    • /
    • pp.35-40
    • /
    • 2020
  • 최근 초소형 생체신호를 측정할 수 있는 스마트 워치 등의 장비들이 출시됨에 따라, 체성분, 혈압, 심박동수, 산소포화도 등 다양한 정보를 쉽게 얻을 수 있다. 그러나 사용자에게 신뢰를 얻지 못하는 부분이 바로 정확성이다. 이러한 생체신호는 외부 환경에 대해 민감하며, 대상자 신체 내부의 조건에 따라 변동값이 크다. 특히 혈압 측정은 아직 신체 내부의 조건들의 처리에 따라 결과값이 다르다. 따라서 실험에서는 PPG 알고리즘에서 혈관 상태를 정의하는 인자를 특정값으로 처리하고 PPG를 분석하였으며, PTT 측정에 있어서 최고점 80%, 100%의 두 지점 PTT 측정값이 SBP와 DBP에 미치는 영향을 분석하였다. 또한 정확도를 높이기 위한 방안 중 하나를 제시하고자 하였다. 연구결과 PPG 최고점 80%에서 측정값 PTT값이 100%에서 측정한 값보다 SBP, DBP 혈압추정에 효과적이며, 변화율 혈압추정의 회귀분석에서 SBP(80%)의 결정계수가 0.6946, DBP(100%)는 0.547로 나타났다. 결론적으로 ECG와 PPG를 통해 PTT를 측정할 경우 PPG 80% 지점의 측정값이 혈압추정의 정확도를 향상시킬 수 있다.