• 제목/요약/키워드: Blood pressure

검색결과 4,612건 처리시간 0.037초

소금 섭취 행태와 혈압: 맛에 대한 민감도와 선호도의 영향 (Salt Intake Behavior and Blood Pressure: the effect of taste sensitivity and preference)

  • 김진희;최만규
    • 한국생활과학회지
    • /
    • 제16권4호
    • /
    • pp.837-848
    • /
    • 2007
  • The literature suggested that a small reduction in overall blood pressure can have a large effect on overall prevalence of hypertension, and therefore, the affect of taste preferences of the population on salt intake should be considered for long-term blood pressure intervention programs. The purpose of this study is to investigate the influence of salt taste preference and salt taste sensitivity on salt intake behavior as risk factors for high blood pressure. We collected information on blood pressure, diet and lifestyle behaviors, salt taste preference and salt taste sensitivity from 540 respondents from Suseo-dong, Seoul. Salt taste sensitivity was assessed by administering a 1% NaCl solution to the subject's tongue and measuring the perceived intensity on 10 level scale. Salt intake behavior was classified into 3 categories: frequency of high-sodium foods, practice of salt-reducing behavior and frequency of vegetable and fruit intake. Salt taste preference showed a significant relation to the subjects' blood pressure, i.e. subjects with a higher salt preference had higher blood pressure. Salt taste sensitivity did not show a significant relation to blood pressure. However, there was a positive correlation between salt taste preference and salt taste sensitivity. Among the 3 indicators used to measure salt intake behavior, the practice of salt-reducing behavior remained significantly correlated to blood pressure. Moreover, salt-reducing behavior and salt taste preference showed a significant correlation, i.e. people who do not like salty foods tend to practice more salt-reducing behavior, leading to reduced levels in blood pressure. In a population, a small reduction in overall blood pressure can have large effects in overall prevalence of hypertension, in contrast to clinical studies where achievement of an individual's normal blood pressure is emphasized. Therefore, taste preference of the population should be considered for long-term blood pressure intervention programs.

대나무 밟기 운동이 노인의 혈압에 미치는 영향 (Effects of Bamboo Stepping Exercise on Blood Pressure in the Elderly)

  • 송성인;구봉오
    • 대한통합의학회지
    • /
    • 제7권1호
    • /
    • pp.75-80
    • /
    • 2019
  • Purpose : This study investigated the effect of bamboo stepping exercises on the blood pressure of the elderly. This study was performed for 8 weeks. Methods : The study participants included 25 people aged 65 and over. Of the participants, 16 were in the hypertensive elderly group and 9 were in the normal blood pressure elderly group. The participants stepped on semicircular bamboo for 20 minutes 3 times a week for 8 weeks. The participants' blood pressure was measured 3 times before and after 8 weeks of exercise. The mean values of the 3 before and after measurements were compared and analyzed statistically. Results : The systolic blood pressure of the hypertensive elderly group decreased significantly from $134.6{\pm}21.1mmHg$ to $119.9{\pm}18.1mmHg$ (p<.05). The diastolic blood pressure of the hypertensive elderly group decreased from $70.2{\pm}10.5mmHg$ to $66.1{\pm}9.8mmHg$, but the difference was not significant. The systolic blood pressure of the normal blood pressure elderly group decreased significantly from $127.2{\pm}18.7mmHg$ to $115.5{\pm}19mmHg$ (p<.05). The diastolic blood pressure of the normal blood pressure elderly group decreased from $72.6{\pm}11.3mmHg$ to $68.2{\pm}12mmHg$, but the decrease was not significant. Conclusion : After completing 8 weeks of the bamboo stepping exercises, the elderly participants' systolic blood pressure was effectively reduced. Today, lifestyle modifications, such as daily exercise, are necessary to control the blood pressure of the elderly. We hope that the bamboo stepping exercises, which are easy to perform and are not restricted by place and time, will become part of the elderly health policy.

A Comparison of Ultrasonic Doppler and Oscillometric Methods in Systemic Blood Pressure Measurement of Dogs

  • Gang, Ho-min;Song, Joong-Hyun;Cho, Kyu-Woan;Jung, Dong-In
    • 한국임상수의학회지
    • /
    • 제33권6호
    • /
    • pp.321-324
    • /
    • 2016
  • The present study compared two indirect blood pressure methods at thoracic limb, pelvic limb, and coccygeal sites. For measurement of blood pressure, 48 client-owned dogs in a clinical setting were used. When comparing the results obtained by doppler and oscillometric methods, there were significant differences in blood pressure of the thoracic and pelvic limbs. The Doppler machine produced significantly higher blood pressure value than oscillometry measured at thoracic and pelvic limbs. The difference in blood pressure between the two methods was not significant when measured in the tail. Comparison of blood pressure measured at three different sites by doppler, blood pressure measured at pelvic limb was higher than at thoracic limb and tail. In case of oscillometry, there were no significant differences between the three sites. The results of this study indicate that mechanical and positional differences were existed in blood pressure measurements at the canine thoracic limb, pelvic limb and tail.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권4호
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

Automatic blood pressure measurement device using oscillometric method and Korotkoff sounds

  • Wei, Ran;Lim, Young Chul;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • 제1권2호
    • /
    • pp.20-25
    • /
    • 2012
  • The oscillometric method and Korotkoff sound method are the most common ways to measure the blood pressure. A new automatic blood pressure measurement device, which uses both oscillometric method and Korotkoff method, was developed. A pressure sensor was used to obtain cuff pressure and oscillation signal, and a microphone was used to detect Korotkoff sounds. Forty-five measurements from fifteen subjects were used for analysis. Correlation coefficients between the traditional auscultatory method and Korotkoff sound method were 0.9820 and 0.9721 for the systolic and diastolic blood pressure values, respectively. Standard deviations of differences for the systolic and diastolic blood pressure values were 1.3019 and 1.4495, respectively. Correspondingly, correlation coefficients between the traditional auscultatory method and oscillometric method using newly developed algorithm were 0.9651 and 0.9136 for the systolic and diastolic blood pressure values, with the standard deviations of 1.42 and 1.73, respectively. The results showed that the newly developed algorithm for oscillometirc method provide accurate blood pressure values, moreover, Korotkoff sound method using microphone provides even higher accuracy. Therefore, a new automatic device which utilizes both oscillometric method and Korotkoff sound method would provide the accurate and reliable blood pressure values.

다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교 (Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure)

  • 송효숙;전태국;최은정;김미정
    • 기본간호학회지
    • /
    • 제8권3호
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

비례제어밸브와 혼합제어기를 이용한 혈압 시뮬레이터의 구현 (Implement of Blood Pressure Simulator Using Proportional Control Valve and Hybrid Controller)

  • 이규원;김철한;한기봉;김호종;전계록
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2005년도 춘계학술대회 논문집
    • /
    • pp.149-153
    • /
    • 2005
  • In the cardiovascular system, the waveform of the pulsatory blood pressure appears variously due to the cardiac impulse and compliance of blood vessels and arm tissue. We have constructed a blood pressure simulator to investigate effects of mechanical properties of artery walls and tissue on blood pressure measurements. The blood pressure simulator is designed to reproduce wave forms of blood pressure in human arteries. To minimize tracking error, we use a linear control valve, and adapt a hybrid control scheme which consists of a feedback controller and a feedforward controller. Any form of the pressure wave can be reproduced, changing function of the wave form in the computer connected to the simulator for control. From experiments, it has been shown that the simulator reproduces wave forms very well, and that the hybrid scheme adapted is superior to the feedback controller.

  • PDF

Does Inhaled Peppermint Essential Oil Affect Blood Pressure?

  • Park, Sah-Hoon;Kim, Kun-Hee;Park, Jong-Seong
    • 통합자연과학논문집
    • /
    • 제14권3호
    • /
    • pp.95-98
    • /
    • 2021
  • By far, studies on the effect of oral administration of peppermint essential oil on blood pressure are not consistent, increasing or decreasing. And the effect of inhalation of peppermint essential oil on blood pressure was not reported. This study was designed to clarify the effect of peppermint essential oil inhalation on the blood pressure and autonomic nervous system. Blood pressure and heart rate variability (HRV) as an indicator of autonomic nervous system activity were measured. The systolic and diastolic blood pressure was not changed significantly by inhalation of peppermint essential oil. Standard deviation of normal to normal (SDNN), a parameter of total activity of autonomic nervous system also was not changed significantly. High frequency (HF) power level, an indicator of parasympathetic nervous system activity was not changed by peppermint. These results indicate that action mechanism of peppermint essential oil on blood pressure is different by the method of administration, oral or inhalation.

비침습적 혈압 측정 시스템 구현에 관한 연구 (A Study on Implemetation of Non-invasive Blood Pressure)

  • 노영아;이종수;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.451-454
    • /
    • 2000
  • 혈압을 측정하는 방법에는 침습적(Invasive)인 방법과 비침습적(Non-invasive)인 방법이 있는데 침습적인 방법에 의한 혈압측정의 경우 정확한 값을 얻는 반면에 그 사용법이 복잡하고 환자에게 불편하므로 중환자의 경우를 제외한 경우 대부분 비침습적인 방법에 의해 혈압을 측정한다. 현재 전자 혈압계의 경우 대부분이 오실로메트릭(Oscillometric) 방법을 사용하여 기본적인 시스템을 구성하고 여기에 여러 가지 알고리즘을 부가적으로 적용하고 있다. 본 연구에서 이러한 혈압 측정 시스템을 개발하기 위해 커프(Cuff)의 압력을 제어, 측정하고 측정된 데이터를 필터링하여 혈압을 측정할 수 있도록 알고리즘을 구성하였다. 통신방식으로는 개발된 시스템의 모든 기능이 개인용 컴퓨터(Personal Computer)와의 통신을 통해 이루어지도록 구성되어져 있으며, 사용된 통신방식은 비동기 직렬 통신 방식(RS-232)인 패킷방식을 사용하였고 솔레노이드(Solenoid) 밸브를 이용한 자동 또는 급속 배기 방법을 이용하여 커프의 압력을 감압(Deflation)하였다. 혈압측정 알고리즘은 기본적인 오실로메트릭 방법과 최대 진폭 알고리즘(Maximum Amplitude Algorithm)을 사용하였다. 최대진폭 알고리즘에서는 측정된 오실레이션(Oscillation)중 최고의 진폭을 가지는 오실레이션 같은 오차의 원인이 되는 연령이나 체중, 팔의 두께에 따라 다양하게 나타난다. 본 연구에서는 오실레이션의 간에 획일적인 비율을 적용하지 않고 여러 가지 요인들에 대한 가변적인 특정 비율(Characteristic Ratio)반영하여 보다 정확한 최고혈압(Systolic Blood Pressure), 최저혈압(Diastolic Blood Pressure), 평균혈압(Mean Blood Pressure)의 값을 구하는 연구를 하였다. 최고진폭 알고리즘에서 가변적인 특성비율의 적용은 혈압간의 오차를 줄일 수 있을것으로 기대된다.

  • PDF

혈중 납과 혈압의 연관성에 관한 메타분석 (A Meta-analysis of the Association between Blood Lead and Blood Pressure)

  • 고상백;남정모;최홍열;차봉석;박종구;지호성;김춘배
    • Journal of Preventive Medicine and Public Health
    • /
    • 제34권3호
    • /
    • pp.262-268
    • /
    • 2001
  • Objectives : To integrate the results of studies which assess an association between blood lead and blood pressure. Methods : We surveyed the existing literature using a MEDLINE search with blood lead and blood pressure as key words, including reports published from January 1980 to December 2000. The criteria for quality evaluation were as follows: 1) the study subjects must have been workers exposed to lead, and 2) both blood pressure and blood lead must have been measured and presented with sufficient details so as to estimate or calculate the size of the association as a continuous variable. Among the 129 articles retrieved, 13 studies were selected for quantitative meta-analysis. Before the integration of each regression coefficient for the association between blood pressure and blood lead, a homogeneity test was conducted. Results : As the homogeneity of studies was rejected in a fixed effect model, we used the results in a random effect model. Our quantitative meta-analysis yielded weighted regression coefficients of blood lead associated with systolic blood pressure and diastolic blood pressure results of 0.0047 (95% confidence interval [CI]: -0.0061, 0.0155) and 0.0004 (95% CI: -0.0031, 0.0039), respectively. Conclusions : The published evidence suggested that there may be a weak positive association between blood lead and blood pressure, but the association is not significant.

  • PDF