• Title/Summary/Keyword: Blood gas analysis

Search Result 221, Processing Time 0.027 seconds

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

Quantitative Analysis of Tiropramide in Human Blood by Gas Chromatography with Nitrogen-Phosphorus Detector

  • Kwon, Oh-Seung;Park, Young-Jin;Ryu, Jae-Chun;Chung, Youn-Bok
    • Archives of Pharmacal Research
    • /
    • v.26 no.5
    • /
    • pp.416-420
    • /
    • 2003
  • The analytical method of antispasmodic agent tiropramide {$(\pm)\alpha$-(benzoylamino)-4-[2-(diethylamino)ethoxy]-N,N-dipropylbenzenepropanamide hydrochloride} was developed by gas chromatography/nitrogen-phosphorus detector (GC/NPD) in human plasma. Two kinds of tiropramide tablets were orally administered to volunteers by Latin square crossover design, and blood was withdrawn as designed schedule. The plasma of 1 mL was loaded on Sep-pak $C_{18}$ cartridge and eluted with methanol after washing with 30% methanol. The residue dissolved in 100 $\mu$L of methanol after evaporation was analyzed by GC/NPD. Precision (CV%) of intra-day was located within 2.6% and accuracy was less than 9.7%. Inter-day precision was below 8.7% and accuracy was relatively good as less than 14%. Plasma samples obtained from human volunteers were analyzed for the determination of tiropramide concentration by using this method. The method was sensitive, rapid and suitable enough to be applied for pharmacokinetic and bioequivalence studies of tiropramide in human volunteers.

A Study on DNA Degeneration by Comet Assay & Pathological Observation for Mouse Which were Exposed HCN Gases from Fire (화재로 인한 HCN 가스에 노출된 마우스의 병리학적 관찰 및 단세포 전기영동법을 사용한 DNA 변성 추적에 관한 연구)

  • Cho, Nam-Wook;Oh, Eun-Ha;Hwang, Sung-Kwy
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.7-16
    • /
    • 2012
  • Combustion Toxic Effects among several factors of risk encountered during fire are important in the evacuation and final survival, and they are broader and fatal than the direct damages caused by flame. Most studies on fire toxicity until the present are limited to fatality, mainly deaths by fire through pathological research. In this study, it is conducted as a fundamental experiment to address 3 principles of animal experiment and to provide an alternative test to animal testing that is regulated by national building codes and it was conducted through approval by the animal testing ethics committee. Hence, in this study average time of activity stop was measured after directly inhaling toxic gases (HCN) to laboratory animals (mice) through gas toxicity test (KS F 2271) for major asphyxiating gases(HCN) which are produced during fire combustion. effects of Combustion toxic gases on body were quantitatively analyzed through changes in internal organs and hematological analysis, and electrophoresis of a single cell of these laboratory animals. Biological conclusion of combustion toxicology is drawn through approaches (pathological examination, blood test, blood biochemical test, electrophoresis analysis of single cell) which could not confirmed in existing gas toxicity test.

Explainable analysis of the Relationship between Hypertension with Gas leakages (설명 가능한 인공지능 기술을 활용한 가스누출과 고혈압의 연관 분석)

  • Dashdondov, Khongorzul;Jo, Kyuri;Kim, Mi-Hye
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.55-56
    • /
    • 2022
  • Hypertension is a severe health problem and increases the risk of other health issues, such as heart disease, heart attack, and stroke. In this research, we propose a machine learning-based prediction method for the risk of chronic hypertension. The proposed method consists of four main modules. In the first module, the linear interpolation method fills missing values of the integration of gas and meteorological datasets. In the second module, the OrdinalEncoder-based normalization is followed by the Decision tree algorithm to select important features. The prediction analysis module builds three models based on k-Nearest Neighbors, Decision Tree, and Random Forest to predict hypertension levels. Finally, the features used in the prediction model are explained by the DeepSHAP approach. The proposed method is evaluated by integrating the Korean meteorological agency dataset, natural gas leakage dataset, and Korean National Health and Nutrition Examination Survey dataset. The experimental results showed important global features for the hypertension of the entire population and local components for particular patients. Based on the local explanation results for a randomly selected 65-year-old male, the effect of hypertension increased from 0.694 to 1.249 when age increased by 0.37 and gas loss increased by 0.17. Therefore, it is concluded that gas loss is the cause of high blood pressure.

Reactive Airways Dysfunction Syndrome (RADS) from Chlorine Gas Releasing Cleaning Agents (염산 흡입 후 발생한 Reactive Airways Dysfunction Syndrome (RADS) 1례)

  • Cho, Kwang-Hyun;Kim, Seung-Hwan;Cho, Young-Soon;Lee, Hahn-Shick;Park, Joon-Seok
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.1
    • /
    • pp.60-62
    • /
    • 2005
  • A previously healthy 57-year-old woman with dyspnea and wheezing presented to the emergency department a few minutes after exposure to unknown gas from mixing bleach (sodium hypochlorite) and cleaning agent (hydrochloric acid) at work place. Initial physical examination revealed severe wheezing on both whole lung fields, but the chest radiograph was normal. Arterial blood gas analysis showed only moderate hypoxemia. The patient was treated with oxygen, $\beta$adrenergic bronchodilators, antihistamines and corticosteroids, after then symptoms were improved. And the patient discharged against medical advice. We report a rare case of reactive airways dysfuntion syndrome from chlorine gas exposure.

  • PDF

Distribution of Abused Drugs in 275 Alcohol-positive Blood Samples of Korean Driver (음주운전자 275명 혈액 중 마약류 및 남용약물의 분석)

  • Choi, Hye-Young;Lee, Ju-Seon;Choi, Sang-Kil;Kim, Eun-Mi;Kim, Jae-Kyun;Kim, Young-Woon;Lim, Mi-Ae;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.137-146
    • /
    • 2008
  • Even though driving under the influence of drug (DUID) is a worldwide problem, we, Korea has no regulation system yet except for alcohol, and there are little cases reported related to DUID. In order to investigate the type of abused drugs for drivers in Korea, we tried to analyze controlled and non-controlled drugs in alcohol-positive blood samples. 275 whole bloods, which were positive for alcohol on the roadside test, were collected from the police for two months ($Nov.{\sim}Dec.$ 2006). The analytical strategy was constituted of three steps: First, alcohol in blood samples were confirmed and quantified by gas chromatography. Second, controlled drugs were screened by $Evidence_{investigator}\;^{TM}$ (Randox, U.K.) as preliminary test. It was based on immunoassay by biochip array analyzer. Nine groups of drug abuse were screened: amphetamines, methamphetamines, cannabis, cocaine, opiates, barbiturates, methadone, benzodiazepines I (oxazepam) & II (lorazepam). Finally, confirmation of these drugs was performed by GC-MS. Blood samples were extracted by solid-phase extraction by $RapidTrace^{TM}$ (Zymark, U.S.A.). After trimethylsilyl (TMS) derivatization, eluates were analyzed to GC-MS. Total 49 drugs were investigated in this study including controlled drugs, antidepressants, 1st generation antihistamines, dextromethorphan, nalbuphine, ketamine, etc. For rapid detection, we developed the automated identification system. It was made up a new software, "DrugMan", modified Chemstation data analysis menu and newly developed macro modules. A series of peak selection, identification and reporting of the results were performed automatically by this system. Concentrations of alcohol in 275 blood samples were ranged from 0.011 to 0.249% (average, 0.119%). Among 149 blood samples, just six samples (4.0%) were showed positive results to the immunoassay: one methamphetamine and five benzodiazepines group I. By GC-MS confirmation, only benzodiazepines were detected and methamphetamine was not detected from immunoassay positive blood sample. Besides these drugs, 5 chlorpheniramines, dextromethorphan, diazepam, doxylamine, ibuprofen, lidocaine and topiramate were also detected in whole bloods by GC-MS. Conclusively, the frequency of drug abuse for Korean drivers was relatively low. There was none case which illegal drug was detected. However these results were limited to alcohol positive blood samples, so it is necessary to analyze more samples including alcohol negative blood.

A Comparative Study Between On-Pump and Off-Pump Coronary Artery Bypass Grafting on Clinical Outcomes

  • Moon Seong-Min;Choi Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.237-243
    • /
    • 2004
  • In recent, many cardiac centers have preferred off-pump coronary artery bypass grafting (CABG) to on-pump CABG to prevent the adverse effects of cardiopulmonary bypass. The present study was performed to prove beneficial effects of off-pump CABG. Sixty adult patients scheduled for elective CABG were randomly assigned to On-pump group (n=30) or Off-pump group (n=30). Arterial blood samples were drawn before and after the operation (Pre-OP and Post-OP, respectively) for measuring CBC, prothrombin time, activated thromboplastine time, blood gas analysis, creatine kinase-MB (CK-MB) level, and lactate dehydrogenase (LDH) level. Perioperative parameters including heparin and protamine usages, complications, blood components usages, blood loss, ventilation and ICU-staying time, and hospitalization were also evaluated. Platelet count at Post-OP was high in Off-pump group whereas CK-MB and LDH levels were low compared with On-pump group. Off-pump group had significantly lower heparin and protamine usages, lower total leukocyte count, higher hematocrit and hemoglobin levels, less blood loss, lower usages of blood components, shorter ventilation and ICU-staying time, and lower incidence of pleural effusion than On-pump group. Other variables did not significantly differ between two groups. These results showed that Off-pump CABG was a satisfactory technique with less inflammatory reaction, less cardiac damage, less postoperative complications, and less cost.

  • PDF

Gas Chromatographic Analysis of Zipeprol in Blood (혈액중 지페프롤의 가스크로마토그래피에 의한 분석)

  • Yoo, Young-Chan;Chung, Hee-Sun;Kim, Eun-Mi
    • YAKHAK HOEJI
    • /
    • v.36 no.3
    • /
    • pp.191-198
    • /
    • 1992
  • The abuse of zipeprol, an antitussive agent, is prevalent among young people. Ten fatal cases of zipeprol concentration in blood after its abuse had caused death are disscussed. GC equipped with TSD was used to quantify the drug in postmortem blood and GC/MS to identify the metabolites in urine after preliminary test. The calibration curve of zipeprol was linear (r = 0.998) and the recoveries of zipeprol 5, 10 and $20\;{\mu}g$ added to 1 ml postmortem blood were $97.2{\pm}3.9$, $92.5{\pm}3.9$ and $86.9{\pm}4.6%$ respectively. The blood zipeprol concentration varied 2.9 to $24.69\;{\mu}g/ml$ in 10 fatal cases. All the deaths were young adults with the age of 16-21. Three metabolites were identified in drug abuser's urine, 2-methoxy-2-phenyl ethylpiperazine, 2-hydroxy-3-methoxy-3-phenyl propylpiperazine and a demethylated zipeprol.

  • PDF

Analysis of $\beta$-Blockers in Whole Blood by GC/MS-SIM

  • Rhee, Jong-Sook;Yang, Hee-Jin;Seol, Il-Ung;Koo, Ki-Ser
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.219.3-219.3
    • /
    • 2003
  • We describe here solid-extraction and derivatisation methods of ${\beta}$-adrenoceptor blocking drugs used for the treatment of various cardiovascular disorders such as hypertension, angina pectoris and cardiac arrhythmia: propranolol, metoprolol, sotalol, timolol, oxprenolol, alpranolol, atenolol, pindolol. Solid-extraction and derivatisation methods are described involving the use of Bond Elut Certify cartridges, MSTFA and MBTFA. Gas chromatographic-mass spectrometry analysis(GC/MS) was carried out select-ion monitroing mode. (omitted)

  • PDF

Mobile-type blood gas analysis system for data transmission system (이동형 혈액가스분석기의 데이터 전송시스템)

  • Kang Sung-Chul;Kim Gi-Ryon;Jung Dong-Keun;Jeong Do-Un;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1027-1031
    • /
    • 2006
  • Recently, mobile-type analysis system when emergency patient can check his blood condition in the transportation or vessel has being required. Under the present system, it takes lots off-time to know the blood analysis result of patient, so, it may lead to a dangerous situation. But, in this study, analysis time makes to fall down to $1{\sim}min$. to emergency treatment patient more quickly, and you can check the information by wireless PC through Bluetooth base. It is able to measure in about 7minutes from 25minutes of warming-up time in existing facilities by testing temperature peculiarity curve, to operate system without error even minute temperature change by adoption DUAL heating. And Bluetooth base was adopted to reduce power consumption and be able to hospital networking by keeping and sending analyzed data when it needs.

  • PDF