• Title/Summary/Keyword: Blood Parameter

Search Result 306, Processing Time 0.032 seconds

Effects of Age and Lines on Blood Parameters in Laying Tsaiya Ducks

  • Lee, S.R.;Shen, T.F.;Jiang, Y.N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.7
    • /
    • pp.984-989
    • /
    • 2004
  • Three hundred and twelve female Tsaiya ducks from four lines (L1051, L1052, L1053 and L1054) were used in this study to investigate the changes in plasma calcium and inorganic phosphorus levels, blood pH, carbon dioxide partial pressure (pCO$_{2}$), bicarbonate ion concentration ($HCO_{3}^{-}$), and base excess (BE) during laying periods. The results indicated that plasma calcium and inorganic phosphorus concentration at 40 and 50 wks of age were higher (p<0.05) than those at other ages. Significant positive correlation coefficients were found between plasma calcium and inorganic phosphorus levels at each age tested from 20 to 50 wks. Ducks from L1053 showed lower (p<0.05) blood pH, BE and $HCO_{3}^{-}$ as compared with other lines. Ducks from L1054 had higher (p<0.05) blood pH, BE and $HCO_{3}^{-}$ than those of other lines showing that there were some differences on blood parameters among lines. Eggshell strength decreased with age up to 65 wks and remained constant thereafter. Egg weight increased gradually from 30 to 60 wks and decreased slightly after 70 wks of age. Plasma inorganic phosphorus level in 40 and 50 wks old birds was positively correlated with eggshell strength, while blood $HCO_{3}^{-}$ in 40 and 50 wks old birds was negatively correlated with eggshell strength.

Hemodynamic Analysis of Pig's Left Common Coronary Artery (LCCA) (II) (좌주간부 관상동맥(LCCA)에 관한 혈류역학적 분석 (II))

  • Moon, Su-Yeon;Jang, Ju-Hee;Park, Jung-Su;Shin, Seh-Yun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2043-2047
    • /
    • 2003
  • The distributions of blood pressure, blood flow, and blow volume in the left common artery (LCCA) were determined using the lumping parameter method. In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary condition. Pressures and volumes of blood and flow resistance were expressed in terms of electrical voltages, current, and resistances, respectively, in the electrical analog model. The results of two mathematical models, symmetrical and asymmetrical models, were compared with other investigator's data. The present results were in good agreement with previous studies. It was found that the mean pressure profiles were similar in both models.

  • PDF

An algorithm for real time blood flow estimation of LDF (LDF의 실시간 혈류추정을 위한 알고리즘)

  • Kim, Jong-Weon;Ko, Han-Woo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.78-79
    • /
    • 1998
  • This paper describes a real time algorithm for blood flow estimation of LDF(laser Doppler flowmeter). Many algorithms for blood flow estimation are using power spectral density of Doppler signal by blood flow. In these research, the fast Fourier transformation is used to estimate power spectral density. This is a block processing procedure rather than real time processing. The algorithm in this paper used parametric spectral estimation. This has real time capability by estimation of AR(autoregressive) parameters sample by sample, and has smoothing power spectrum. Also, the frequency resolution is not limited by number of samples used to estimate AR parameter. Another advantage of this algorithm is that AR model enhance SNR.

  • PDF

Aflatoxin-mediated Sperm and Blood Cell Abnormalities in Mice Fed with Contaminated Corn

  • Fapohunda, S. O.;Ezekiel, C. N.;Alabi, O. A.;Omole, A.;Chioma, S. O.
    • Mycobiology
    • /
    • v.36 no.4
    • /
    • pp.255-259
    • /
    • 2008
  • The effect of aflatoxin-contaminated corn on albino mice was investigated using the sperm morphology assay. Blood parameter levels including; total white blood cells (WBC), total red blood cells (RBC), packed cell volume (PCV), serum bilirubin (SB) and fasting blood sugar (FBS) were also determined in the tested mice. Test mice were exposed to aflatoxin-contaminated corn (contamination level of 100 ppb) for $1{\sim}4$ weeks while aflatoxin-free corn and cyclophosphamide were used as negative and positive controls, respectively. Sperm cells showed varieties of morphological abnormality when assessed after 5 weeks. The percentage frequencies of the negative and positive controls were 18.8% and 48.87%, respectively, while the percentage abnormalities for the 1, 2, 3 and 4 weeks exposures were 41.38%, 48.17%, 57.13% and 61.67%, respectively. PCV, WBC, total bilirubin and glucose level values of mice in all concentrations were higher and statistically significant as compared to the negative control values using Dunnett's test. Therefore, abnormal sperm cell induction is concentrationdependent such that continuous consumption of aflatoxin-contaminated corn is capable of negatively affecting spermatogenesis by inducing or increasing the frequency of morphologically abnormal sperm cells produced.

A Study on Arterial Characterization by using Up-stroke Time of Photoplethysmogram (용적맥파 상승시간에 의한 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.108-116
    • /
    • 2007
  • This paper proposed an analyzable parameter and its analytic method to provide more accurate information than currently employed 4 channels system which uses pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels for the characterization of arterial vessel. In order to verify the volume pulse waves on 4 sites were simultaneously acquired subjects aged from 12 to 81 years old. and the proposed parameters were extracted from time (UT) was then compared with blood pressure. Then, the regression analyses were done relationships among the proposed parameter and others, such as aging, pulse transit time pressure (BP). The followings are the results of linear regression analysis of the proposed parameter for total 50 normal subjects. We selected any two subjects (58 years and 27 years) and measured PPG (photoplethysmogram) and BP of before and after exercise. The coefficient of correlations between BP and UT observed was -0.928 for 50 years subject, and -0.922 for 20 years subject. For total 50 normal subjects, in case of correlation between the pulse transit time and BP, the result showed -0.170 on left side and -0.233 on right side, and the coefficient value of correlation between the pulse transit time and UT was -0.607 on left side and -0.510 on right side. UI is strongly correlated with the pulse transit time than BP. Hence, we believe that the proposed parameter is related with the index of arterial stiffness.

  • PDF

A study on the pulsatile flow characteristics of Newtonian and non-Newtonian fluids in the bifurcated tubes (분기관내 뉴턴유체와 혈액의 맥동유동특성에 관한 연구)

  • Seo, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3607-3619
    • /
    • 1996
  • Experimental and numerical studies for three-dimensional pulsatile flows are conducted to investigate the flow characteristics in the bifurcated tubes. Velocity measurements in experimental study were made by both Pulsed Doppler Ultrasound(PDU) machine and Laser Doppler Anemometer(LDA) system. Glycerin is used for experimental study. Experimental results are used to verify the results of the numerical simulation. Flow characteristics of Newtonian fluid and blood in the bifurcated tubes under the steady and pulsatlie flows are numerically investigated. Finite volume method is employed for three-dimensional numerical simulations. Blood is considered as a non-Newtonian fluid and the constitutive equation of blood is used for the numerical analysis. Numerical analyses are focused on the flow patterns for various branch angles ranging from 30.deg. to 90.deg. and diameter ratios such as 1.0, 0.8, and 0.6. Pulsatile flow characteristics of blood are compared with those of Newtonian fluid. Parameter effects on axial velocity, pressure and wall shear stress distribution along the bifurcated tubes are discussed in terms of the branch angle, diameter ratio, and Reynolds number.

Blood parameter changes in Korean traditional calves and pigs after foot-and-mouth disease vaccination

  • Cha, Chun-Nam;Park, Eun-Kee;Yoo, Chang-Yeul;Kim, Suk;Yun, Young Won;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.57 no.1
    • /
    • pp.43-45
    • /
    • 2017
  • This study investigated changes in certain blood parameters in calves and pigs after foot-and-mouth disease (FMD) vaccination. In this study, five calves and five pigs were selected from groups of 10 calves and pigs, respectively, and were vaccinated with an FMD vaccine. The remaining animals formed two non-treatment control groups. Blood samples were collected from all animals on the 1st, 3rd, 5th, and 7th days post-vaccination. In the FMD-vaccinated calves and pigs on day 7 post-vaccination, white blood cell counts, blood urea nitrogen levels, and alanine aminotransferase and aspartate aminotransferase activities were higher than those in the respective controls. The present data suggested that the certain hemato-biochemical parameters on cattle and pigs were meaningfully changed between before and after FMD vaccination.

Measurement of Leg Arterial Compliance of Normal and Diabetics (정상인과 당뇨병 환자의 다리 동맥의 Compliance 측정)

  • 김덕원;김상수
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.189-194
    • /
    • 1992
  • As people's income and intake of animal fat rapidly increase, so does choresterol concentration in blood. Thus diseases such as non-insulin-dependent diabetes mellitus(NIDDM)myocardial infraction, high blood pressure, cerebral stroke resulting from atherosclerosis rapidly increase recently. It is very difficult to diagnose atherosclerosis early since its progress is so slow and there is no sypmtoms in the beginning of the disease. In this study a mechanical characteristic, compliance, of the lower leg arteries was measured noninvasively. Changes of blood volume and pressure were measured using impedance plethysmgraphy and mercury sphygmomanometer, respectively. The compliance was calculated by dividing the change of blood volume by the change of pulse pressure ( systolic-diastolic pressure ) . Subjects were 24 asymptomatic persons ranging (rom 30 Ic 58yeras and 14 diabetics from 41 to 59years. The compliances, mean, and systolic pressures were statistically analyzed using a t-test be- tween the healthy and diabetic groups. The average compliance of the healthy and diabetic group was measured 2.79 and 1.82U1/mmHg/cm, respectively and these were significantly different(p<0.01). It was also found that the compliance is a better parameter in differentiating the vascular disease than mean or systolic blood pressure.

  • PDF

Combined Effect of Fluorouracil with Metoclopramide or Propantheline Bromide in Rats and Rabbits (Fluorouracil과 Metoclopramide 및 Propantheline.Bromide와의 병용시(倂用時) 항암효과(抗癌効果)에 관한 연구(硏究))

  • Choi, Jun-Shik;Lee, Jin-Hwan;Baik, Chai-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • This paper was attempted to study on the effect of metoclopramide or propantheline on the absorption rate and bioavailability and pharmacokinetic parameter of fluorouracil in rats and rabbits. The result are as follows; Metoclopramide increased the absorption rate of fluorouracil but propantheline decreased in situ experiment with rat small intestine. Metoclopramide increased the blood level and relative bioavailability and absorption rate constant of fluorouracil in rabbits. Prolonged the peak blood level (tmax) and decreased the absorption rate constant (Ka) but did not affect the blood level and relative bioavailability of fluorouracil in rabbits. As a matter of fact, it is considerd that the coadministration of metoclopramide or propantheline is more desirable than the single administration of fluorouracil for available dosage regimen.

  • PDF

Complex Permittivity Extraction of Blood Glucose at Microwave Frequency

  • Jeong, You-Chul;Lee, Hee-seok;Kim, Joung-ho
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.2
    • /
    • pp.139-145
    • /
    • 2001
  • In this paper, a coaxial sample holder is proposed with its de-embedding and parameter extraction procedure. The S-parameters were measured up to 1 GHz using network analyzer, HP8753D, and N-type connector together with the de-embedding of N-type connector. The proposed de-embedding procedure is performed to extract electrical parameters of blood glucose, which gives the permittivity of blood glucose. We also analyzed the error of extracted parameters, which are caused by instrument error and geometrical error. Using these error analyses, we reduced the error factors of extracted parameters. We extracted electrical parameters of glucose samples through these all extraction procedure and confirmed the possibility of glucose diagnosis system based on microwave system.

  • PDF