• Title/Summary/Keyword: Blood Glucose Test Meter

Search Result 5, Processing Time 0.026 seconds

Development of Reliability Demonstration Test for Personal Blood Glucose Meters (개인용 혈당측정기의 신뢰성 보증시험 개발)

  • Kim, Gi-Young;Park, Ho-Joon;Park, Chan-Soo;Ham, Jung-Keol;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.4
    • /
    • pp.299-307
    • /
    • 2013
  • The value of blood sugar is measured by a personal blood glucose meter which consists of two parts: a glucose strip and a blood glucose meter. A personal blood glucose meter makes use of electric media which are composed of glucose oxidase and electron. This study is to propose a method of reliability demonstration test derived from field data analysis and FMEA(Failure Mode and Effect Analysis). Detailed Conditions for reliability demonstration test are selected from the comparison of various failure mechanisms. The most dominant failure mechanism is wear-out which is caused by strip insertion/extraction. The testing device that can reproduce the failure mechanism of strip insertion/extraction is made to conduct reliability demonstration test. Using the testing device, it is confirmed that target lifetime of selected devices is more than 2 years.

Design and Implementation of a Blood-Glucose Meter to Reduce Hematocrit Interference (적혈구 용적률 간섭 보정을 위한 혈당 측정 기기의 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.4
    • /
    • pp.167-175
    • /
    • 2020
  • A blood-glucose meter is one of the in vitro diagnostic devices to measure and control the glucose concentration of diabetics. In order to measure the glucose level in the blood, the common method is to measure the amount of electrons, that is, the output current generated by glucose oxidation after a blood sample is inserted into the test strip containing an enzyme. The hematocrit is an obstacle in measuring accurate blood glucose concentration. This paper deals with the design and implementation of a blood-glucose meter to correct the hematocrit interference. We propose a sequential method which measures impedance using the alternating current and then measures glucose in the blood using the direct current. In addition, this paper introduces how to use commercial glucose strips based on the proposed system. Finally, we conducted the performance evaluation of the proposed system by comparing the measured current and impedance with those of the references. As a result, the standard deviation of the current measurement is approximately 0.6nA and the impedance measurement error for measuring the hematocrit is approximately within 1%. The proposed system will improve the accuracy of the conventional blood-glucose meter by reducing the hematocrit interference.

Effects of Peony-Licorice Mixture Supplementation on Blood Glucose and Lactate Levels (작약감초탕 섭취가 운동수행 후 혈당과 젖산의 변화에 미치는 영향)

  • Ha, Sung;Lee, Ho-Keun;Seo, Dong-Il
    • The Korea Journal of Herbology
    • /
    • v.27 no.5
    • /
    • pp.93-97
    • /
    • 2012
  • Background : The purpose of this study was to examine that the effects of Peony-Licorice (PL) mixture supplementation on post-exercise blood glucose and lactate in professional women basketball players. Methods: Eleven professional women basketball players were participated in this study. The subjects participated in two trials, PL supplementation and water supplementation. They did 20-meter shuttle run test, and measured blood glucose and lactate level before, immediately, after 3 minutes, after 5 minutes and after 10 minutes the test. Results: There was not interaction effect on blood glucose(p<0.433) and lactate(p<0.770) levels. Blood glucose and lactate levels were increased in PL group and water group after the test. Conclusion: PL supplementation could not affect changing blood glucose and lactate level. Therefore, we suggest that PL supplementation may not be positive ergogenic aid for improving exercise performance in professional women basketball players.

The Effects of 12-Week Training for the Physical Fitness and Cardiovascular Factors to Examine Physical Fitness on Firefighters Test-Taker (소방공무원 수험생의 체력검정을 위한 12주간 훈련이 체력요인, 심혈관계요인에 미치는 영향)

  • Lim, Youn-Sub;Park, Jin-Hong;Kim, Jong-Hyuck;Kim, In-Dong;Kim, Jae-Joong;Park, Jeong-Beom;Lee, Chae-Mun
    • Journal of Industrial Convergence
    • /
    • v.19 no.4
    • /
    • pp.111-126
    • /
    • 2021
  • The purpose of this study was to investigate the effects of 12-week training on changes in physical fitness and cardiovascular factors for firefighters. For this purpose, 40 men in their 20s and 30s who agreed to participate voluntarily were recruited. They were divided into four groups: the firefighters' physical fitness test training group (hereinafter referred to as PT group), firefighters' physical fitness test and aerobic training group (hereinafter referred to as PT+AR group), firefighters' physical fitness test and both aerobic and anaerobic training group (hereinafter referred to as PT+CO group). Physical fitness factors (grip strength, back muscle strength, seated forward bend, standing long jump, sit-ups, 20-meter shuttle run), cardiovascular factors (total cholesterol, triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, glucose, waist circumference, systolic blood pressure, diastolic blood pressure) and the relationship between Framingham Heart Risk Score and physical/cardiovascular factors were compared and analyzed, and the following conclusions were obtained. Aerobic training, anaerobic training, and combined training, including 12 weeks of firefighter physical examinations, all had positive effects on fitness and cardiovascular factors, which would be an appropriate way for firefighter examinees to improve physical strength and reduce the risk of cardiovascular disease.