주기적인 원주형 장애물이 있는 덕트유동 및 열전달의 비직교좌표변환에 의한 해석 (Numerical Analysis of Flow and Heat Transfer in Duct with Repeated Cylindrical Blockages by Non-orthogonal Coordinate Transformation)

  • 최영돈;이건휘
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.473-488
    • /
    • 1988
  • This paper is concerned with the prediction of two dimensional turbulent flows in the parallel plate with the repeated cylindrical blockages. The purpose of this paper is to find the effect of the eccentricity and the pitch of the repeated cylindrical blockages on the flow field, heat transfer coefficients and friction factors. A special technique is developed for the solution of the fully developed turbulent recirculating flow, in which the flow field varies periodically. A non-othogonal coordinate transformation is employed to solve the momentum and the energy equations. The results show that the pitch ratio or the eccentricity of the repeated blockages become smaller, or the Reynolds number of the flow larger, friction factors and heat transfer coefficients increase.

  • PDF

장애물을 갖는 덕트내의 유동가시화 및 수치해석에 관한 해석 (Flow Visualization and Numerical Calculation in a Channel Perturbed by Curvilinear Blockages)

  • 문찬;박진철;김철
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.218-226
    • /
    • 1994
  • Laminar flow and heat transfer in a channel with blockages are obtained numerically in a Reynolds-number range of $100{\leq}Re{\leq}400$. A boundary-fitted curvilinear coordinate system is generated for irregular boundary of the physical region, and solutions of Navier-Stokes equation and energy equation are obtained by finite analytic method in the transformed computational domain. The flow separates in downstream of the blockage and the length of separated-flow region increases with Reynolds number. The heat flux is high on the top of the blockages and increase in the heat transfer occurs where the fluid reattaches the wall. Comparison between computed streamlines and experimental flow-visualization is also presented and discussed.

  • PDF

Numerical Prediction of Unsteady Flows through Whole Nozzle-Rotor Cascade Channels with Partial Admission

  • Sasao, Yasuhiro;Monma, Kazuhiro;Tanuma, Tadashi;Yamamoto, Satoru
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권3호
    • /
    • pp.248-253
    • /
    • 2009
  • This paper presents a numerical study for unsteady flows in a high-pressure steam turbine with a partial admission stage. Compressible Navier-Stokes equations are solved by the high-order high-resolution finite-difference method based on the fourth-order compact MUSCL TVD scheme, Roe's approximate Riemann solver, and the LU-SGS scheme. The SST-model is also solved for evaluating the eddy-viscosity. The unsteady two-dimensional flows through whole nozzle-rotor cascade channels considering a partial admission are numerically investigated. 108 nozzle passages with two blockages and 60 rotor passages are simultaneously calculated. The influence of the flange in the nozzle box to the lift of rotors is predicted. Also the efficiency of the partial admission stage changing the number of blockages and the number of nozzles is parametrically predicted.

냉시동시 채널 막힘이 고분자전해질연료전지의 장기성능에 미치는 영향 (Effects of channel blockages during cold start up on durability of proton exchange membrane fuel cell)

  • 이상엽;김형준;조은애;장종현;임태훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2008
  • Cell degradation when anode channels are blocked during cold start up was tested and measured. Proton exchange membrane fuel cell (PEMFC) stacks with several configurations of channel blockages were operated and decay in performance was analyzed. When only channels near hydrogen inlet were blocked, performance was rarely changed. In contrast, significant cell reversal occurred and considerable amount of $CO_2$ was produced when all channels near inlet and outlet were blocked. In the case, it was also observed that performance was severely decreased in the area where hydrogen was not supplied sufficiently.

  • PDF

비틀림 유도파를 이용한 배관 내부 슬러지검출 (Sludge Detection Inside Pipes Using Torsional Guided Waves)

  • 박경조;김정엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.757-762
    • /
    • 2013
  • A technique is presented that uses a new guided wave technique for sludge and blockages detection in long-range pipelines. Existing techniques have the limitations that the sludge position needs to be known a priori and the area to be inspected needs to be accessible. Two guided wave techniques have been developed which allow the sludge or blockages to be detected remotely without the need to access the specific location where the pipe is blocked, nor to open the pipe. The first technique measures the reflection of guided waves by sludge which can be used to accurately locate the blocked region; the second technique detects sludge by revealing the changes to the transmitted guided waves propagating in the blocked region or after it. The two techniques complement each other and their combination leads to a reliable sludge or blockage detection. Various types of realistic sludge have been considered in the study and the practical capabilities of the two techniques have been demonstrated.

  • PDF

UHPLC 시스템 종료 및 재가동 시 가이드 (UHPLC System Shutdown and Reactivation Advice)

  • Mark Fever;Gemma Lo
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.8.1-8.3
    • /
    • 2024
  • Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.

  • PDF

다봉채널내의 공기-물 플러딩 : 스페이서 그릿 및 블럭키지의 영향 (Air-Water Flooding in Multirod Channels : Effects of Spacer Grids and Blockages)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.381-393
    • /
    • 1993
  • 이 논문은 하강하는 물의 막과 상승하는 공기유동으로 구성된 수직 다봉채널내서의 역유동 플러딩에 관한 실험결과를 발표한 것이다. 특히 다봉속에 혼합깃이 있는 것과 없는 스페이서 그릿 및 블럭키지가 프러딩의 거동에 미치는 영향이 조사되었다. 시험부에는 5$\times$5 지르칼로이관속이 사용되었다. 플러딩에 관한 전의 해석적 모델과 실험적 상관식들을 본 실험결과와 비교한즉 기존의 모델과 상관식들이 매우 높은 플러딩 곡선을 예측함이 발혀졌다. 스페이서 그릿은 이것이 없는 봉속과 비교하면 낮은 플러딩 공기유량을 나타낸다. 그러나 혼합깃이 있는 스페이서 그릿은 이것이 없는 스페이서 그릿에 비하여 높은 플러딩 공기유량이 요구된다. 블럭키지를 가진 봉속은 더욱더 높은 플러딩 공기유량을 갖는다. 세가지 형식의 시험봉 속에 대한 실험적 플러딩 상관식이 얻어졌다.

  • PDF

A review on the risk, prevention and control of cooling water intake blockage in coastal nuclear power plants

  • Heshan Lin;Shuyi Zhang;Ranran Cao;Shihao Yu;Wei Bai;Rongyong Zhang;Jia Yang;Li Dai;Jianxin Chen;Yu Zhang;Hongni Xu;Kun Liu;Xinke Zhang
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.389-401
    • /
    • 2024
  • In recent decades, numerous instances of blockages have been reported in coastal nuclear power plants globally, leading to serious safety accidents such as power reduction, manual or automatic power loss, or shutdown of nuclear power units. Loss or shortage of cooling water may compromise the reliability of the cooling water system, thus threatening the operational safety of power plants and resulting in revenue reduction. This study provides a comprehensive review of the current state of cooling water system safety in coastal nuclear power plants worldwide and the common challenges they face, as well as the relevant research on cooling water system safety issues. The research overview and progress in investigation methods, outbreak mechanisms, prevention and control measures, and practical cases of blockages were summarized. Despite existing research, there are still many shortcomings regarding the pertinence, comprehensiveness and prospects of related research, and many problems urgently need to be solved. The most fundamental concern involves understanding the list of potential risks of blockages and their spatially distributed effects in surrounding waters. Furthermore, knowledge of the biological cycles and ecological habits of key organisms is essential for implementing risk prevention and control and for building a scientific and effective monitoring system.

비틀림 유도파를 이용한 배관 내부 슬러지검출 (Sludge Detection Inside Pipes Using Torsional Guided Waves)

  • 박경조;김정엽
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.282-290
    • /
    • 2013
  • A new method is presented that uses guided wave techniques for sludge and blockages detection in long-range pipelines. Existing techniques have the limitations that the sludge position needs to be known a priori and the area to be inspected needs to be accessible. Two guided wave techniques have been developed which allow the sludge or blockages to be detected remotely without the need to access the specific location where the pipe is blocked, nor to open the pipe. The first technique measures the reflection of guided waves by sludge which can be used to accurately locate the blocked region; the second technique detects sludge by revealing the changes to the transmitted guided waves propagating in the blocked region or after it. The two techniques complement each other and their combination leads to a reliable sludge or blockage detection. Various types of realistic sludge have been considered in the study and the practical capabilities of the two techniques have been demonstrated.

In-situ Blockage Monitoring of Sensing Line

  • Mangi, Aijaz Ahmed;Shahid, Syed Salman;Mirza, Sikander Hayat
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.98-113
    • /
    • 2016
  • A reactor vessel level monitoring system measures the water level in a reactor during normal operation and abnormal conditions. A drop in the water level can expose nuclear fuel, which may lead to fuel meltdown and radiation spread in accident conditions. A level monitoring system mainly consists of a sensing line and pressure transmitter. Over a period of time boron sediments or other impurities can clog the line which may degrade the accuracy of the monitoring system. The aim of this study is to determine blockage in a sensing line using the energy of the composite signal. An equivalent Pi circuit model is used to simulate blockages in the sensing line and the system's response is examined under different blockage levels. Composite signals obtained from the model and plant's unblocked and blocked channels are decomposed into six levels of details and approximations using a wavelet filter bank. The percentage of energy is calculated at each level for approximations. It is observed that the percentage of energy reduces as the blockage level in the sensing line increases. The results of the model and operational data are well correlated. Thus, in our opinion variation in the energy levels of approximations can be used as an index to determine the presence and degree of blockage in a sensing line.