• Title/Summary/Keyword: Block scan

Search Result 103, Processing Time 0.023 seconds

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Early Results of Heart Transplantaion: A Review of 20 Patients (심장이식술 20례의 조기성적)

  • Park, Chong-Bin;Song, Hyun;Song, Meong-Gun;Kim, Jae-Joong;Lee, Jay-Won;Seo, Dong-Man;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.164-171
    • /
    • 1997
  • Heart transplantation is now accepted as a definitive therapeutic modality in patients with terminal hear failure. The first successful heart transplantation in humans was done in 1967 and the first case in Korea was performed in november, 1992. Since the first case in 1992, more than 50 cases have been performed in Korea. A total of 20 patients underwent orthotopic heart transplantation since November, 1992 in Asan Medicla Center. The purpose of this study is to evaluate the early results and the follow-up course of 20 cases of heart transplantation done in Asan Medical Center. The average age of 20 patients was 39.9$\pm$11.8 years old(20~58). The mean follow-up duration was 14.4$\pm$11.2 months(1~41). All patients are alive till now. The blood type was identical in 14 and compatible in 6 patients. ihe original heart disease was dilated cardiomyopathy in 16, valvular heart disease in 2, ischemic cardiomyopathy in 1, and giant cell myocarditis in 1 patient. HLA cross matching for recipient and donor was done in 18 cases and the results were negative for T-cell and B-cell in 16 patients, pos tive for warm B-cell in 2 patients. Among 6 loci of A, B, and DR, one locus was matched in 8 cases, 2 loci in 5 cases, and 3 loci matched in 1 case. The number of acute allograft rejection averaged 2.8$\pm$0.5 (0~6) per case and the number of acute allograft rejection requiring treatment averaged 1.0$\pm$0.9 (1~3) per case. The time interval from operation to the first acute rejection requiring treatment was 35.5$\pm$20.4 days (5~60). Acute humoral rejection was suspected strongly in 1 case and was successfully treated. The left ventricular ejection fraction measured by echocardiography and/or MUGA scan was dramatically increased from 17.5$\pm$6.8 (9~32)% to 58.9$\pm$2.0 (55~62)% after heart transplantation. Temporary pacing was needed in 5 patients over 24 hours but normal sinus rhythm appeared within 7 days in all cases. One patient has been taken permanent pacemaker implantation due to complete AV block appearing 140 days after heart transplantaion. One patient had cyclosporine-associated n urotoxicity during the immediate postoperative period and was recovered after 27 hours. The heart transplantation of Asan Medical Center is on a developing stage but the early result is comparable to that of well established centers in other countries, even though the long-term follow-up result must be reevaluated. We can conclude that the heart transplantion is a promising therapeutic option in patients with terminal heart failure.

  • PDF