• 제목/요약/키워드: Block scan

검색결과 103건 처리시간 0.029초

자궁경부재발암 환자의 국소동맥 주입식 동위원소 검사 -방사성 동위원소의 치료시도를 위한 평가- (Intraarterial Scintigraphy in Recurrent Cervix Cancer - The Evaluation of Radionuclide Therapeutic Trials -)

  • 김은영;서진석;박창윤;이종태;유형식
    • 대한핵의학회지
    • /
    • 제24권2호
    • /
    • pp.293-298
    • /
    • 1990
  • We performed 17 intraarterial scintigraphies in six patients with recurrent cervix cancer. With Seldinger method, the agent (four different radiopharmaceuticals) was perfused at the same speed of infusion of anticancer drugs (25 cc/hour) through internal iliac artery. There were four different radiopharmaceuticals; I-131-Lipiodol, Tc (Technetium)-99m-HSa (Human Serum Albumin), $^{99m}Tc-Sucralfate$ and $^{99m}Tc-MAA$ (Macroaggraegated Albumin). We evaluate the distribution pattern of radioactivity by the use of ratio of Tumor/Extratumor uptake (T/ET ratio). Our results reveals that $^{99m}Tc-MAA$ scan showed the highest T/ET ratio and the other were not ideal agents for intraarterial therapy of recurrent cervix cancer. In conclusion, an ideal radioisotope and tracer which can block capillary, for example MAA, should be re-evaluated or produced in order to treat the patient with recurrent cervix cancer.

  • PDF

다결정 실리콘 박막 트랜지스터 Active Matrix OLED 디스플레이를 위한 이중 변조 구동 (Dual Modulation Driving for Poly-Si TFT Active Matrix OLED Displays)

  • 김재근;정주영
    • 대한전자공학회논문지SD
    • /
    • 제41권10호
    • /
    • pp.17-22
    • /
    • 2004
  • 본 논문에서는 진폭 변조와 펄스 폭 변조를 모두 사용하는 새로운 AMOLED 디스플레이 구동 방식을 개발하였다. 펄스 폭 변조를 위해서 다섯 개의 서브 프레임으로 화상 프레임을 나누었고 진폭 변조를 위해 TFT 게이트 전압에 의해 제어되는 3가지의 OLED 휘도(전류) 레벨을 사용하였다. 이 두 종류의 변조를 조합하여 35(=243) 계조를 얻었다. 그리고 DAC를 사용하지 않고 2개의 쉬프트 레지스터를 갖는 새로운 데이터 전극 구동 회로를 설계하였다. 회로 동작은 6㎛ 채널 길이 다결정 TFT의 전류-전압 특성에서 추출된 TFT 파라미터를 이용한 HSpice 시뮬레이션을 통하여 검증하였다. 시뮬레이션 결과로부터 320×240, 이중 스캔, 243 계조 AMOLED 디스플레이를 구현할 수 있음을 확인하였다.

모바일 단말기에서 이미지 처리에 필요한 메모리 사용량을 줄이기 위한 타일화 이미지 압축 기법 (Tiled Image Compression Method to Reduce the Amount of Memory Needed for Image Processing in Mobile Devices)

  • 오황석
    • 한국게임학회 논문지
    • /
    • 제13권6호
    • /
    • pp.35-42
    • /
    • 2013
  • 본 논문에서는 모바일 기기의 프로세서 처리 능력과 메모리 용량의 제한에 관계없이 거대 크기의 이미지를 게임의 배경으로 사용하기 위한 타일화된 이미지 압축 기법을 제안한다. 실험을 통하여 제안한 기법이 압축 효율 측면에서는 하나의 PNG 파일로 압축하는 방법과 유사하나 모바일 단말기의 메모리 제한으로 인한 디코딩 가능한 이미지의 크기 제한 문제를 해결할 수 있음을 보였다. 또한 실행 시 부분 디코딩 기법을 적용하여 단말기 화면에 출력되는 이미지 부분만 디코딩하여 출력함으로 초기의 대규모 이미지의 로딩 시간을 줄일 수 있음을 보였다.

GPU 하드웨어 아키텍처 기반 sub-warp 단위 병렬 프리픽스(prefix) 연산의 정확한 구현 (Correct Implementation of Sub-warp Parallel Prefix Operations based on GPU Hardware Architecture)

  • 박태정
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권3호
    • /
    • pp.613-619
    • /
    • 2017
  • 본 논문에서는 대규모 데이터를 길이가 32 미만인 로컬 세그먼트 단위로 구분하고 이 로컬 세그먼트 내에서 정확한 GPU 병렬 프리픽스(prefix) 연산 결과를 출력하는 CUDA (Compute Unified Device Architecture) 코드를 제시한다. 이미 Mark Harris와 Michael Garland가 이러한 목적을 수행하기 위한 CUDA 코드를 이미 발표한 바 있으나 본 논문에서는 로컬 세그먼트의 길이가 32 미만일 때 기존 코드의 결과가 정확하지 않다는 사실을 살펴 보고 그 원인을 논의한 후, 정확한 결과를 출력하는 코드를 제안한다. 본 논문에서 다루는 로컬 세그먼트 단위의 병렬 프리픽스 연산은 최인접 요소 탐색(k-nearest neighbor search) 등은 물론 다양한 대규모 병렬 처리 알고리즘을 구성하는 기본 연산으로 활용 가능하다.

요부 경막외 스테로이드 주입 후 발생한 무균성 수막염 -증례 보고- (Aseptic Meningitis after a Lumbar Epidural Steroid Injection -A case report-)

  • 황병문;임정길
    • The Korean Journal of Pain
    • /
    • 제18권1호
    • /
    • pp.52-55
    • /
    • 2005
  • Complications following a well conducted epidural steroid injection are rare. A 50-year-old man developed a headache and neck stiffness 2 days after a lumbar epidural steroid injection. Under the impression of aseptic meningitis, fluid and nonsteroidal anti-inflammatory drug therapy was started immediately after cerebrospinal fluid (CSF) sampling. The CSF was turbid, and revealed a white blood cell count, protein, glucose and pressure of $550/{\mu}l$ (98% lymphocyte), 107.9 mg/dl, 48 mg/dl (serum 113 mg/dl) and $17cmH_2O$, respectively. The CSF stain and culture, and antibody test and polymerase chain reaction for pathogens were negative. A computed tomography (CT) scan of the brain revealed no abnormality, and a chest roentgenogram and the results of the neurological examination were normal. Under the impression of aseptic meningitis, the condition was managed conservatively, without antibiotics. Seven days later, the clinical symptoms had improved, and the patient discharged.

Accidental intracerebral injection and seizure during scalp nerve blocks for awake craniotomy in a previously craniotomized patient -a case report-

  • Lee, Woo Kyung;Kim, Hyunzu;Bae, Myung-Il;Choi, Seung Ho;Min, Kyeong Tae
    • Korean Journal of Anesthesiology
    • /
    • 제71권6호
    • /
    • pp.483-485
    • /
    • 2018
  • A 34-year-old man who previously underwent a craniotomy due to oligodendroglioma was admitted with a diagnosis of recurrent brain tumor. An awake craniotomy was planned. Approximately 15 minutes after completing the scalp nerve block, his upper torso suddenly moved and trembled for 10 seconds, suggesting a generalized clonic seizure. He recovered gradually and fully in 55 minutes without any neurological sequelae. The emergency computed tomography scan revealed a localized fluid collection and small intracerebral hemorrhage nearby in the temporoparietal cortex beneath the skull defect. He underwent surgery under general anesthesia at 8 hours after the seizure and was discharged from the hospital after 10 days. This report documents the first case of generalized seizure that was caused by the accidental intracerebral injection of local anesthetics. Although the patient recovered completely, the clinical implications regarding the scalp infiltration technique in a patient with skull defects are discussed.

전자선치료 시 3D 프린터로 제작한 환자 맞춤형 차폐체의 유용성 평가 (Evaluation of the Usefulness of Patient Customized Shielding Block Made with 3D Printer in the Skin Cancer Electron Beam Therapy)

  • 안기송;정우찬;김대현;김무섭;윤도군;심재구;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.447-454
    • /
    • 2019
  • In order to improve and supplement the shielding method for electron beam treatment, we designed a patient-specific shielding method using a 3D printer, and evaluated the usefulness by comparing and analyzing the distribution of electron beam doses to adjacent organs. In order to treat 5 cm sized superficial tumors around the lens, a CT Simulator was used to scan the Alderson Rando phantom and the DICOM file was converted into an STL file. The converted STL file was used to design a patient-specific shield and mold that matched the body surface contour of the treatment site. The thickness of the shield was 1 cm and 1.5 cm, and the mold was printed using a 3D printer, and the patient customized shielding block (PCSB) was fabricated with a cerrobend alloy with a thickness of 1 cm and 1.5 cm. The dosimetry was performed by attaching an EBT3 film on the surface of the Alderson Rando phantom eyelid and measuring the dose of 6, 9, and 12 MeV electron beams on the film using four shielding methods. Shielding rates were 83.89%, 87.14%, 87.39% at 6, 9, and 12 MeV without shielding, 1 cm (92.04%, 87.48%, 86.49%), 1.5 cm (91.13%, 91.88% with PSCB), 92.66%) The shielding rate was measured as 1 cm (90.7%, 92.23%, 88.08%) and 1.5 cm (88.31%, 90.66%, 91.81%) when the shielding block and the patient-specific shield were used together. PCSB fabrication improves shielding efficiency over conventional shielding methods. Therefore, PSCB may be useful for clinical application.

다차원 DCT를 이용한 비디오 부호화기 설계 (Design of video encoder using Multi-dimensional DCT)

  • 전수열;최우진;오승준;정세윤;최진수;문경애;홍진우;안창범
    • 방송공학회논문지
    • /
    • 제13권5호
    • /
    • pp.732-743
    • /
    • 2008
  • 본 논문은 H.264/AVC가 이전의 비디오 코덱에서 사용하는 8$\times$8 변환이 아닌 4$\times$4 변환을 도입하면서 인트라 및 인터 예측 성능을 높인 반면 공간적 압축도가 낮은 점을 개선하기 위한 다차원 변환 방법을 제안한다. 다차원 변환 방법은 H.264/AVC가 갖는 시간적 예측의 장점과 공간적 압축도를 동시에 충족시킬 수 있는 방법이다. 먼저 실험을 통해 다차원 DCT가 H.264/AVC의 2차원 정수 변환(Integer Transform)보다 에너지 압축율이 높다는 것을 보였다. 다차원 DCT를 위한 정수형 변환과 양자화기를 설계하였으며, H.264에서 사용하는 컨텍스트 기반 적응 가변 길이 코딩 (CAVLC)을 엔트로피 코더로 사용하여 다차원 부호화기를 설계하였다. 다차원 부호화기에는 다차원 변환에 따른 블록 주사 방식과 파라미터 갱신, 다차원 변환 모드 선택 등의 도구가 적용되었다. 실험 결과, 다차원 부호화기는 낮은 비트율에서 H.264/AVC와 유사한 압축 효율을 보였지만, 엔트로피와 0이 아닌 계수를 계산하여 비교한 통계적 성능 비교에서는 높은 성능을 보였다. 따라서, 다차원 부호화에 대한 추가적인 연구가 진행된다면 기존의 H.264/AVC의 성능을 보완할 수 있는 부호화 알고리즘으로서 발전할 수 있을 것이다.

68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구 (Study of 68Ga Labelled PET/CT Scan Parameters Optimization)

  • 곽인석;이혁;김시활;문승철
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

이진 프린트 영상에 적용하는 디지털 워터마킹의 성능 개선 (An Improved Method of Digital Watermarking Applied to Binary Printed Images)

  • 김현주;곽내정;권혁봉;안재형
    • 한국멀티미디어학회논문지
    • /
    • 제4권3호
    • /
    • pp.247-256
    • /
    • 2001
  • 디지털 워터마킹은 데이터 내부에 지각적으로 인식되지 않는 신호를 삽입하여 저작권을 보호하기 위한 방법으로 압축, 기하학적 변환, 크기변환 등의 공격도 영상 데이터가 견고한 특성을 나타낼 수 있는 방법을 중심으로 연구되어 왔으나 프린트 영상에 대하여 저작권을 보호하는 연구는 그다지 활발하지 않았다. 본 논문에서는 이진 프린트 영상에 워터마크를 삽입하는 새로운 방법을 제안한다. 제안방법은 영상을 디더링 한 후 $16\times{16}$ 크기의 블록에서 1(백화소)의 개수를 카운팅하고 카운팅 배열을 $2\times{2}$ 블록씩 나누어 워터마크 값에 따라 다르게 정의된 기준 블록 패턴과 비교함으로 워터마크를 삽입한다. 워터마크 정보는 '1' 과 '0'의 두 가지를 사용하여 동일한 워터마크 비트로 더 많은 정보를 표현할 수 있다. 워터마크 검출은 워터마크가 삽입된 영상과 기준 블록 패턴을 이용해 워터마크 정보를 재구성하고, 재구성된 워터마크와 디더 영상에 삽입된 원본의 워터마크 정보와 비교함으로 가능하다. 성능평가는 워터마크 삽입영상을 프린트 한 후 스캔하여 기존의 방법과 검출 성능을 비교하였다.

  • PDF