Changes in Centration of Contact Lenses on Cornea and Blink Rate Associated with Overusage of Disposable Lenses (일일 착용 렌즈의 착용기간 초과시 유발되는 렌즈의 중심 안정 위치 및 순목횟수 변화)

  • Park, Mijung;Yang, Jae Heon;Kim, Sun Mi;Park, Sang-Il;Park, Sang Hee;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Purpose: This study was assessed to investigate adverse effect induced by overuse of disposable soft contact lenses (CL). Methods: Three disposable lenses (etafilcon A, hilabilcon A, and nelfilcon A) were applied to 19 normal subjects free from any eye diseases for either a single day or variable periods by when subjects complained any discomforts. On the first and last days, localizations of lens' center on corneal surface and blink rates were recorded at every case. Results: Among CL wearers, 10.5% and 47.4% of total subjects quit wearing on the second day and third day, respectively. The case of stopping disposable lens wear was continuously increased with extended hour of lens application. On fourth day, 70.2% of CL wearers reported severe discomforts such as redness, dryness, irritation, pain and blurred vision. When subjects stopped CL wear, decentration of lens from the center of cornea was observed when it compared to the case of single usage of disposable CL. Also about 80% of total subjects showed increased blink rate when CL were worn for more than 2 days. These changes in lens centration and blink rate were consistantly shown regardless of lens types. Conclusions: Blurred vision and acute/chronic discomforts could occur to CL wearers by decentration of lens and increased blink rate when CL were overused more than 2 days even the numbers of two parameters measured in this study were variable by each subject or lens types. Therefore, consideration of individual characteristics and lens types is critical to prevent adverse effects may induced by overusage of disposable lens.

  • PDF

Eye as a Human/Computer Interface Device (눈으로 조종하는 인간/컴퓨터 인터페이스)

  • 박경수;이경태
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.36-47
    • /
    • 1996
  • By integrating the eye head-position monitioring devices, the present authors developed an eye-controlled human/computer interface based on the line-of-sight and an intentional blink to invoke commands. Also modified was an existing calibration method to reduce the visual angle between the target center and the intersection point of the derived line-of-sight. This modified calibration method allowed 108 or more command blocks to be displayed on the 14 inch monitor with the target acquisition probability(hit rate) of 98% when viewed at the distance of 500 mm apart. An active triggering method using an intentional blink was proposed and was shown to be a feasible and efficient alternative to invoke commands with total triggering time of 0.8 sec or less. The system could be used by the normal people as well as the handicapped individuals as a new human/computer interface.

  • PDF

PSYCHOPHYSIOLOGICAL CHANGES DURING VIRTUAL REALITY NAVIGATION

  • Kim, Y.Y.;Kim, E.N.;C.Y. Jung;H.D. Ko;Kim, H.T.
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.107-113
    • /
    • 2002
  • We examined the psychophysiological effects of navigation in a virtual reality (VR). Subjects were exposed to the VR, and required to detect specific objects. Ten electrophysiological signals were recorded before, during, and after navigation in the VR. Six questionnaires on the VR experience were acquired from 45 healthy subjects. There were significant changes between the VR period and the pre-VR control period in several psychophysiological measurements. During the VR period, eye blink, skin conductance level, and alpha frequency of EEG were decreased but gamma wave were increased. Physiological changes associated with cybersickness included increased heart rate, eye blink, skin conductance response, and gamma wave and decreased photoplethysmogram and skin temperature. These results suggest an attentional change during VR navigation and activation of the autonomic nervous system for cybersickness. These findings would enhance our understanding for the psychophysiological changes during VR navigation and cybersickness.

  • PDF

Eye Blink Detection and Alarm System to Reduce Symptoms of Computer Vision Syndrome

  • Atheer K. Alsaif;Abdul Rauf Baig
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.5
    • /
    • pp.193-206
    • /
    • 2023
  • In recent years, and with the increased adoption of digital transformation and spending long hours in front of these devices, clinicians have observed that the prolonged use of visual display units (VDUs) can result in a certain symptom complex, which has been defined as computer vision syndrome (CVS). This syndrome has been affected by many causes, such as light refractive errors, poor computer design, workplace ergonomics, and a highly demanding visual task. This research focuses on eliminating one of CVSs, which is the eye dry syndrome caused by infrequent eye blink rate while using a smart device for a long time. This research attempt to find a limitation on the current tools. In addition, exploring the other use cases to utilize the solution based on each vertical and needs.

Damped Oscill ations of the (Hard)Contact Lenses Posterior to the Blink (순목 후 콘택트(하드)렌즈의 감쇄 진동)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.173-184
    • /
    • 2005
  • A capillary action-induced tension develops in the tear layer between the contact lens and cornea, which leads to the restoring force due to difference in the layer thickness between either upper and lower or left and right side of the lens when it is displaced off the equilibrium position as a result of blinking. Suppose the lens was displaced a certain distance from the equilibrium position, lens starts to oscillate toward the equilibrium position with the decreasing amplitude due to the restoring force as well as the velocity dependent viscous damping force in the tear layer. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped oscillations of lenses. The model predicts the time dependence of lenses after the blink varying the various parameters such as Be, diameters, masses and positions displaced from equilibrium. As the Be and mass of lens increases the rate of amplitude reduction decreases, which requires a more time for the lens to return to the equilibrium position. It seems that varying the lens' displacement and diameters affect the lens' motion very little.

  • PDF

A Study on the Confidence of Dry Eye Diagnosis Methods (건성안 검사 방법의 신뢰도에 대한 연구)

  • Lee, Byeong Jun;Hong, Jae Hyeon;Jung, Dai;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • Purpose: To study on the confidence of dry eye diagnosis methods which need to prescribe contact lens. Methods: Non-invasive tear film break-up time (NIBUT) and tear film break-up time (TBUT) were measured in forty healthy subjects in their 20s, and then the subjects were classified into normal eye and dry eye. The results of McMonnies questionnaire, tear prism height measurement, Hardtack test, blink rate measurement and Schirmer test were compared with the results of NIBUT and TBUT. Results: The results of NIBUT and TBUT were as follows; 20 subjects had normal eyes, 10 subjects had dry eyes in both NIBUT and TBUT, and 10 subjects showed different results. In McMonnies questionnaire, the score of normal eye group averaged 8.2 and that of dry eye group averaged 18.5, which showed statistically significant difference. Furthermore, 100% of normal eye group classified by the results of NIBUT and TBUT corresponded with the result of McMonnies questionnaire and 90% of dry eye group showed the correspondence. Tear prism height of normal eye group averaged 0.32 mm and that of dry eye group averaged 0.23 mm, which were significantly different. Hardtack test, blink rate measurement and Schirmer test without local anesthesia showed no statistically significant difference between normal eye group and dry eye group. Conclusions: On dry eye diagnosis methods, the results of McMonnies questionnaire and tear prism height measurement had close correlation with the results of NIBUT and TBUT.

  • PDF

Eye Movement-based Visual Discomfort Analysis from Watching Stereoscopic 3D Contents Regarding Brightness and Viewing Distance (눈 움직임을 이용한 밝기와 시청거리에 따른 3D 콘텐츠 피로도 분석)

  • Kim, Yong-Woo;Kang, Hang-Bong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.9
    • /
    • pp.1723-1737
    • /
    • 2016
  • When watching 3D contents, people often experience various visual discomforts like tiredness, dryness, headaches, and dizziness. Previous researches on visual discomfort analyzed and concluded vergence-accommodation conflict, viewing distance, and brightness changes to be the causes of visual discomfort. Yet it is necessary to systematically analyze the visual discomfort due to the changes in object, background brightness and viewing distance. In this paper, we produce four videos that have four different background brightness and two different viewing distances to solve analyze the visual discomfort from watching 3D contents. We measure and analyze eye-blink and saccadic movement, saccadic latency, Nearest Point of Convergence (NPC), and participant survey for amore accurate result compared to previous researches. Our results show that the eye-blink rate and saccadic latency increase when the background is bright and viewing distance is close while the saccadic movement decreases in the same environment. However, NPC only changes when the background brightness changes. We confirm that the bright background and near viewing distance create greater visual discomfort and decrease depth perception abilities.

Relationship between biosignal, raction time, and eye blink depending on arousal level (I) (각성상태에 따른 생리신호와 반응시간 및 눈깜박임의 상관관계 (I))

  • Ko, H.W.;Kim, Y.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.426-429
    • /
    • 1997
  • This paper describes the relationship among physiological, behavioral signal, and subjective evaluation depending on arousal level. Nz and reaction time hall similar pattern with KSS level, but eyeblink rate was different from these two parameters. Eyeblink rate increased slowly from KSS level 1 to 5, and had high increasing rate at KSS 7. But it showed steep descent at KSS level 9. From the result of reaction time test, since human performance was decreased rapidly above the KSS level 5, it is desirable to give a subject some stimulus such as sound or aroma to rise arousal level above the KSS level 3.

  • PDF

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.

Driver Fatigue and Physiological Responses to Driving Conditions (주행상황에 따른 운전피로와 생리적 반응)

  • 성은정;민병찬;최현재;김태은;전광진;강인형;신용균;김철중
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.65-70
    • /
    • 2002
  • 본 연구에서는 3시간 연속 운전에 따른 운전자의 피로감 및 생리적 반응을 고속도로 주행과 시내주행으로 실시하여 비교 검토하였다. 중추신경계 반응의 측정결과 양 주행조건 모두 각성되고 불쾌하였으나 시내주행의 경우가 상대적으로 각성되고 쾌한 경우가 많았던 것으로 나타났다. 한편, 시내주행의 경우는 심박수의 변화가 심하였으나, 고속도로의 주행에서는 눈깜빡임율이 크게 증가하였다. 따라서 2가지 주행 조건 모두 운전시간이 경과함에 따라 피로감을 느끼나 그러한 피로감을 느끼는 원인이나 현상은 상이한 것으로 나타났다.

  • PDF