• 제목/요약/키워드: Blind test

검색결과 417건 처리시간 0.024초

이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구 (Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction)

  • 강은철;유성연;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

Effects of Pressure Cooker Brand Awareness on the Consumer Acceptability of Cooked Rice

  • Kim, Dong-Hee;Kim, Hee-Sup
    • Food Quality and Culture
    • /
    • 제1권1호
    • /
    • pp.34-39
    • /
    • 2007
  • The effects of pressure cooker brand awareness, in terms of rice cooking performance, were evaluated using consumer acceptability tests. A blind test was performed using rice samples cooked by 3 different pressure cookers without any brand information, and a brand awareness test followed with the same informed consumer panel. Overall acceptability, glossiness, stickiness, hardness, flavor, and color were evaluated and compared to determine whether or not there were changes on consumer choice for acceptability. Brand A and brand B were not significantly different in their overall acceptability, moisture content, flavor, or color (p > 0.05), but they were significantly different for glossiness, stickiness, and hardness. Brands A and C were significantly different for all the attributes (p < 0.05). In the brand awareness test, brands A and B were not significantly different in their liking scores for all the attributes (p > 0.05). Brand C had significantly lower liking scores for overall acceptability, glossiness, stickiness, hardness, and moisture content than the other brands (p < 0.05). When comparing the liking scores for all the attributes with those of the blind test, the scores of the brand awareness test were slightly higher. For brand A, there were changes in its liking scores for overall acceptability, flavor, and glossiness (p < 0.05). However, brands B and C had brand awareness effects for all the attributes (p < 0.05).

  • PDF

Japanese Vowel Sound Classification Using Fuzzy Inference System

  • Phitakwinai, Suwannee;Sawada, Hideyuki;Auephanwiriyakul, Sansanee;Theera-Umpon, Nipon
    • 한국융합학회논문지
    • /
    • 제5권1호
    • /
    • pp.35-41
    • /
    • 2014
  • An automatic speech recognition system is one of the popular research problems. There are many research groups working in this field for different language including Japanese. Japanese vowel recognition is one of important parts in the Japanese speech recognition system. The vowel classification system with the Mamdani fuzzy inference system was developed in this research. We tested our system on the blind test data set collected from one male native Japanese speaker and four male non-native Japanese speakers. All subjects in the blind test data set were not the same subjects in the training data set. We found out that the classification rate from the training data set is 95.0 %. In the speaker-independent experiments, the classification rate from the native speaker is around 70.0 %, whereas that from the non-native speakers is around 80.5 %.

전신 뼈검사에서의 영상 평가 연구 (Study on Image Quality Assessment in Whole Body Bone Scan)

  • 권오준;허재;이한울;김주연;박민수;노동욱;강천구;김재삼
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.30-36
    • /
    • 2015
  • 전신 뼈검사는 골수염과 골절 및 원발성 암의 조기 발견 등골 병변에 대해 높은 민감도와 해상도를 가진 검사이며, 핵의학 검사 중 가장 많은 비중을 차지하고 있다. 그러나 최저 계수치를 제외한 평가 기준이 마련되어 있지 않다. 따라서, 본 연구에서 전신 뼈검사에서 정량적인 평가 지표를 나타낼 수 있는 방법을 분석해보고자 하였다. 본 연구는 2014년 4월부터 2014년 9월까지 본원을 내원한 특이 골병변소견이 없는 환자 30명을 대상으로 GE INFINIA 장비에서 진행하였다. 환자의 전신계수와 허리뼈를 관심영역으로 하여, 계수치를 측정하였으며, 허리뼈 각각의 신호평균 값과 표준편차를 구하여, 대조도 대 잡음비(Contrast to Noise Ratio, CNR), 신호 대 잡음비(Signal to Noise Ratio, SNR)를 산출하였고, 팬텀 실험을 통해 검사 속도 변화에 따른 각각의 수치와 조직등가물질을 이용하여 복부 두께에 따른 수치를 비교 하였다. 그리고, 판독의 2명과 5년 이상의 경력을 가진 숙련된 방사선사 5명이 각각 10점 척도로 하여, Blind test로 육안적인 분석치와 정량적인 산출치 간의 상관관계를 분석하였다. 환자의 전신 계수치와 관심영역의 계수치는 Blind test를 통한 육안적인 분석치와 유의한 상관관계를 보이지 않았다(P>0.05). 대조도 대 잡음비와 신호 대 잡음비는 육안적인 분석치와 유의한 상관관계를 보였다(P<0.05). 팬텀 실험에서는 검사 속도가 느릴수록, 조직등가물질의 두께가 얇을수록 각 수치는 향상되는 것을 보였으며, 지연검사에서 영상의 질이 향상됨을 확인하였다. 현재 전신 뼈검사에서 최저 계수치를 제외한 평가 기준이 마련되어있지 않다. 이에 본 연구에서는 대조도 대 잡음비 및 신호 대 잡음비를 이용하여 Blind test와의 유의한 상관관계를 확인 할 수 있었으며, 검사 속도가 영상의 질을 좌우하는 인자라는 것을 수치를 통해 확인하였다. 본 연구에서는 동일한 주입량, 동일한 검사 속도 등 동등한 조건에서의 평가를 진행하였지만, 환자의 생리적 기능과 수분 섭취량 등에 따라 모든 특성을 고려하는 것에 한계가 존재한다. 그러나 객관적으로 정량적 수치를 제시하여, 유의한 평가 지표를 입증하였다는 데에 학술적 의미가 있을 것으로 사료된다.

  • PDF

A Randomized single blind controlled clinical trial on safety and efficacy of a Unani formulation (Itrifal-e-Sagheer) in dyslipidemia

  • Alam, Sazid;Alam, MD Anzar;Quamri, MA;Sofi, Ghulamuddin;Khan, Mohd. Qudratullah;Ansari, Shabnam
    • 셀메드
    • /
    • 제10권1호
    • /
    • pp.8.1-8.7
    • /
    • 2020
  • Aim:'Itrifal-e-Sagheer', a compound Unani formulation has been indicated in disease conditions simulating dyslipidemia. The present study was done to substantiate the efficacy of 'Itrifal-e-Sagheer' in dyslipidemia on scientific parameters. Materials and methods: A randomized, single blind, controlled, clinical trial was carried out on 30 patients of dyslipidemia who were randomly allocated into test (n = 15) or control (n = 15) groups. The test drug, Itrifal-e-Sagheer and control drug, Abana® were given to respective group for 45 days along with lifestyle modification. Results: The test drug significantly alleviated the symptoms of subjective parameters (palpitation, breathlessness and weight gain) (p<0.05). There was statistically significant reduction in lipid profile of the patients in test group (p<0.05) than control drug treatment. Conclusion: The study evidenced that Itrifal-e-Sagheer is potentially effective and safe in the treatment of dyslipidemia. However, a multicentric study with robust study design is required to generalize the results.

NEW PHARMACOLOGICAL, CLINICAL, MICROBIOLOGICAL AND ANALYTICAL TESTS MADE WITH VARIOUS GINSENG PREFARATIONS OF THE WORLD MARKET

  • Rueckert Karl Heinz
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 1978년도 학술대회지
    • /
    • pp.85-92
    • /
    • 1978
  • The aim of the double blind test was to assess the prophylactic and therapeutic efficacy of the preparation GINSANA, containing the standardized ginseng extract PHARMATON G115,. The determination was carried out with special emphasis on the following features : general physical condition, physical performance, mental performance, enjoyment of life/mood, concentration and memory, as well as sleeping habits. Sixty test persons took part in the study, men and women between the ages of 22 and 80. The 90-day test was carried out in the form of a double blind experiment. Experimental measurements were made and the persons were also questioned. The reaction time, the optical merging threshold, the coordination of both hands and the recovery quotients, as well as the recovery rates were analyzed. The results for the serum group were clearly better than those for the placebo group, particularly for the characteristics: general physical condition, physical performance and sleeping habits. The results of the test methods used, especially with regard to the reaction time, the coordination of both hands, the recovery quotient and the recovery period, permit the following conclusion to be drawn: when administered for several weeks, GINSANA has a positive action, in the sense of an activation of the entire personality by the ginseng glycosides contained in the standardized Extracts G115.

  • PDF

Influence of stiffeners on the performance of blind-bolt end-plate connections to CFST columns

  • Ding, Fa-xing;Pan, Zhi-cheng;Liu, Peng;Huang, Shi-jian;Luo, Liang;Zhang, Tao
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.447-462
    • /
    • 2020
  • The paper aims to investigate the mechanical mechanism and seismic effect of stiffeners in blind bolt endplate connection to CFST column. A precise 3D finite element model with considering the cyclic properties of concrete and steel materials was established, and the efficiency was validated through monotonic and cyclic test data. The deforming pattern and the seismic performance of the unstiffened and stiffened blind bolt endplate connections were investigated. Then a parametric analysis was conducted to analyze the contribution of stiffeners and the joint working behaviors with endplate under cyclic load. The joint stiffness classifications were compared and a supplement stiffness classification method was proposed, and the energy dissipation ability of different class connections were compared and discussed. Results indicated that the main deformation pattern of unstiffened blind bolt endplate connections was the local bending of end plate. The vertical stiffeners can effectively alleviate the local bending deformation of end plate. And influence of stiffeners in thin endplate and thick endplate was different. Based on the stiffness of external diaphragm welded connection, a more detailed rigidity classification was proposed which included the pin, semi-rigid, quasi-rigid and rigid connection. Beam was the main energy dissipation source for rigid connection. For the semi-rigid and quasi-rigid connection, the extended endplate, stiffeners and steel beam would all participate in the energy dissipation.

Comparison of ondansetron and granisetron for antiemetic prophylaxis in maxillofacial surgery patients receiving general anesthesia: a prospective, randomised, and double blind study

  • Savant, Kiran;Khandeparker, Rakshit Vijay Sinai;Berwal, Vikas;Khandeparker, Purva Vijay;Jain, Hunny
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권2호
    • /
    • pp.84-89
    • /
    • 2016
  • Objectives: To compare the efficacy of intravenous ondansetron (4 mg, 2 mL) and granisetron (2 mg, 2 mL) for preventing postoperative nausea and vomiting (PONV) in patients during oral and maxillofacial surgical procedures under general anesthesia. Materials and Methods: A prospective, randomized, and double blind clinical study was carried out with 60 patients undergoing oral and maxillofacial surgical procedures under general anesthesia. Patients were divided into two groups of 30 individuals each. Approximately two minutes before induction of general anesthesia, each patient received either 4 mg (2 mL) ondansetron or 2 mg (2 mL) granisetron intravenously in a double blind manner. Balanced anesthetic technique was used for all patients. Patients were assessed for episodes of nausea, retching, vomiting, and the need for rescue antiemetic at intervals of 0-2, 3, 6, 12, and 24 hours after surgery. Incidence of complete response and adverse effects were assessed at 24 hours postoperatively. Data was tabulated and subjected to statistical analysis using the chi-square test, unpaired t-test, or the Mann-Whitney U-test as appropriate. A P-value less than 0.05 was considered statistically significant. Results: There was no statistically significant difference between the two groups for incidence of PONV or the need for rescue antiemetic. Both study drugs were well tolerated with minimum adverse effects; the most common adverse effect was headache. The overall incidence of complete response in the granisetron group (86.7%) was significantly higher than the ondansetron group (60.0%). Conclusion: Granisetron at an intravenous dose of 2 mg was found to be safe, well tolerated, and more effective by increasing the incidence of complete response compared to 4 mg intravenous ondansetron when used for antiemetic prophylaxis in maxillofacial surgery patients receiving general anesthesia. Benefits of granisetron include high receptor specificity and high potency, which make it a valuable alternative to ondansetron.

동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정 (The Application of Dynamic Acquisition with Motion Correction for Static Image)

  • 윤석환;승종민;김계환;김재일;이형진;김진의;김현주
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.46-53
    • /
    • 2010
  • 정적 영상 획득 시 기존의 정적 영상 획득 방식 대신 동적 영상 획득 방식을 이용하여 움직임에 의한 motion correction을 적용함으로써 정적 영상 획득 시 발생되는 움직임에 의한 문제점을 해결하고자 하였다. 실험은 capillary tube와 IEC body phantom을 이용하여 움직임이 없을 때 정적 영상 획득 방식으로 얻은 영상과 동적 영상 획득 방식으로 얻은 각각의 frame을 더한 영상에 대해 resolution, frequency, total counts, blind test를 비교 분석하였으며 임의로 최소한의 움직임과 과도한 움직임을 주어 motion correction 전후의 영상에 대해서도 resolution, frequency, total counts, blind test를 비교 분석 하였다. 기존의 정적 영상 획득 방식으로 얻은 영상과 동적 영상 획득 방식으로 얻은 각각의 frame을 더한 영상의 resolution, frequency, total counts, blind test의 결과 값의 차이가 없었다. 또한 최소한의 움직임과 과도한 움직임을 준 영상에 대해 motion correction 적용 전후의 비교 결과 값은 motion correction 후 resolution, frequency, blind test의 결과 값이 움직임이 없을 때의 정적 영상과 거의 차이가 없었다. 하지만 과도한 움직임에 대한 보정 시 frame당 흐림 현상이 많이 발생 하였으므로 좌표 보정이 어려워 frame을 제외하는 방법을 적용하였기 때문에 과도한 motion correction 후 삭제한 frame 수만큼 total counts에서 차이를 보였다. 정적 영상 획득 시 움직임이 예상되는 환자에게 기존의 정적 영상 획득방식이 아닌 동적 영상 획득 방식을 이용하여 움직임 발생시 좌표 보정과 흐림 현상이 심한 frame 제외 방법을 이용하여 정적 영상에서 움직임에 의해 발생되었던 영상의 질 저하와 정량적 분석의 신뢰도 감소, 재검사에 대한 문제점을 해결할 수 있을 것이라고 생각되며 motion correction에 제공되는 다양한 프로그램 개발과 임상 적용에 대한 광범위한 연구가 현실적으로 필요하며 향후 지속적인 연구가 기대되는 바이다.

  • PDF