• Title/Summary/Keyword: Blind control

Search Result 474, Processing Time 0.035 seconds

Optimum Blind Control Considering Characteristics of Solar Profile Angle Curve (건물에서 태양 프로파일의 변화 특성을 고려한 블라인드 최적 제어 방안)

  • Seong, Yoon-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.111-124
    • /
    • 2011
  • The objective of this study is to develop the blind control strategy and method which reduce negative effect of incoming daylight on visual comfort of occupants, minimize psychological anxieties caused by frequent motions of a blind, and maximize positive effect of incoming daylight by opening/closing of a blind. In previous researches on blind controls, major problem is that the time interval and amount of blind movement do not meet the control objective at the inflected zone of solar profile curve. To overcome these limitations revealed in theprevious researches, following tasks were performed in this study. i)To establish the control objective to accomplish the goal of this study. ii)To develop the control methods and algorithms which prevent glare on the work-plane at any time and which control the time interval and amount of blind movement to follow the control objective at various solar profile angle curves. This study proposed the control strategy and method that define the base control section implying the inflection point within the control objective zone and subsequently, divide the control sections for the residual time zones. The proposed strategy and method are found to increase the incoming daylight and solar irradiation by 0 to 15 %.

Effects of Postural Control Training Using a Visual Blind Board on Head Control, Trunk Control, and the Sitting Abilities of Children with Moderate to Severe Cerebral Palsy: A Pilot Study (시야 가림막을 활용한 자세 조절 훈련이 중등도-중증 뇌성마비 아동의 머리 조절, 몸통 조절, 앉기 능력에 미치는 효과: 예비연구)

  • Kim, Kun-Woo;Lee, Min-Goo;Hahm, Suk-Chan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.31-40
    • /
    • 2022
  • PURPOSE: This study was conducted to investigate the effects of postural control training using a visual blind board, on head control, trunk control, and the sitting abilities of children with moderate-to-severe cerebral palsy. METHODS: Ten children with moderate to severe cerebral palsy participated in this study. Postural control training with a visual blind board was given for 40 minutes per session, 3 times a week for 4 weeks (12 sessions). Before and after the intervention, head control, trunk control, and sitting abilities were quantified using the head control scale, Korean version-trunk control measurement scale, and the sitting part of the Korean version-gross motor function measure-88, respectively. RESULTS: Postural control with the visual blind board significantly improved the head control ability of children with moderate to severe cerebral palsy (p = .015). Their trunk control abilities also showed significant improvement after the intervention (p = .016). However, their sitting ability did not show a significant change. CONCLUSION: These results showed that postural control training using a visual blind board is effective in improving the head and trunk control abilities of children with cerebral palsy. Further studies with suitable sample sizes and control groups are needed to reach a conclusion about the use of postural control training with visual blind boards for improvement of postural control of children with moderate to severe cerebral palsy.

Automated Blind Control Strategy to Minimize Occupant's Distractions (재실자 방해 최소화를 위한 자동 블라인드 제어 방안)

  • Koo, So-Young;Yeo, Myoung-Souk;Seong, Yoon-Bok;Kim, Kwang-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.84-92
    • /
    • 2013
  • Blinds are a common type of shading device and are increasingly operated automatically to overcome the limitations of manual operation. Automated blinds need to be controlled to maximize benefits of daylight in the point of occupant comfort and energy consumption. However, the previous control methods could cause occupant's distractions by the undesirable control time interval and amount of blind movement. A few researches suggested the control concept for minimizing occupant's distractions by automatic blind control, but they did not provide optimal control algorithm to be useful in practice. In this paper, we propose an optimal control algorithm for automated blinds that can maximize not only visual comfort but also sunlight penetration into buildings based on occupants' preferences on blind movement and sunlight. The proposed control algorithm can prevent solar glare on workplane and minimize occupant's distractions to maximize occupants' visual comfort.

Optimum Blind Control at the End of Operation Time Zone for Preventing Glare on Work-plane and Maximizing Daylight and Solar Heat Gain (작업면 현휘 방지와 주광 및 일사 유입 최대화를 위한 제어 종료 영역에서의 최적 블라인드 제어)

  • Seong, Yoon-Bok;Yeo, Myoung-Souk;Koo, So-Young;Kim, Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.27-41
    • /
    • 2012
  • The objective of this study is to develop the blind control strategy and method which reduce negative effect of incoming daylight on visual comfort of occupants, minimize psychological anxieties caused by frequent motions of a blind, and maximize positive effect of incoming daylight and solar irradiation by opening/closing of a blind. As previous researches on blind controls have limited outdoor environmental conditions to those in specific regions, orientations and dates, these resulted in problems at various conditions for general-purpose application. Major problem is that the time interval and amount of blind movement do not meet the control objective at the end of control zone and discontinuous curve. To overcome these limitations revealed in the previous researches, following tasks were performed in this study. 1) To establish the control objective to accomplish the goal of this study. 2) To develop the control methods and algorithms which prevent glare on the work-plane at any time and which control the time interval and amount of blind movement to follow the control objective at various profile angle curves. 3) To validate the general-purpose applicability and performance of the developed control methods and algorithms by simulation and its data analysis at various conditions. It was found that the proposed methods and algorithms can prevent the direct glare on the work-plane at all the time and also increase the incoming daylight and solar irradiation.

Monitoring System of Blind Areas in a Skiing Resort using a USN (USN을 이용한 스키장 사각 지역 감시 시스템)

  • Lee, Hyung-Bong;Jung, Ui-Min;Park, Lae-Jeong;Moon, Jung-Ho;Chung, Tae-Yun
    • The KIPS Transactions:PartD
    • /
    • v.16D no.2
    • /
    • pp.249-256
    • /
    • 2009
  • This paper introduces an efficient USN (ubiquitous sensor network) for monitoring blind areas in a skiing resort, developed as a part of u-Sport showcase project of Gangwon Province. Blind areas of a skiing resort are dangerous and/or steep areas located aroud ski slopes, which are rarely traveled and not easily seen by a ski patrol. If an accident occurs in such a blind area, the main control center of the sking resort can hardly recognize the accident and provide first aid and rescue services promptly. The blind area monitoring system proposed in this paper monitors a blind area of a skiing resort using five battery-powered sensor nodes each of which has an image sensor on it and wirelessly transmits images around the blind area to the main control center on a regular basis, therebly allowing real-time monitoring of the blind area and prompt rescue services in case of accidents. Additionally, the monitoring system provides an emergency button which skiers injured in the blind area can push. If the button is pushed, an image around the button and an alarm signal are transmitted to the main control center and therefore the main control center can take prompt actions for rescuing the injured skiers.

A Measurement of Luminous Environment and Power Generation according to Control Methods of Blind PV (블라인드 PV 제어에 따른 실내 빛환경 및 발전량 측정)

  • Kim, So-Hyun;Son, A-Rom;Kim, In-Tea;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.14-21
    • /
    • 2013
  • Today, energy problem has become an important issue, and a development of renewable energy is urgent. In architectural fields, a research of the energy efficient lighting system using renewable energy is in progress. The energy efficient lighting system could be realized by integrating a daylight responsive LED lighting control system and a blind PV system. This system is able to save and generate electric energy. Efficiency of this system depends on control methods of blind PV. As a preliminary research, this research analyzed power generation and inflow of available daylight according to control method of blind PV.

Optimized slat angle control algorithm prediction of venetian blind depending on window orientation for energy saving (건물에너지 저감을 위한 향별 슬랫형 블라인드의 최적각도 제어 알고리즘 산출)

  • Kwon, Hyuk-Ju;Lee, Keum-Ho;Lee, Kwang
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.99-106
    • /
    • 2017
  • Purpose: Most modern office buildings adopt the curtain wall system in order to provide occupants with the sense of openness and high-technology, which requires large window area. As a result, the amount of solar radiation increases, negatively affecting cooling load during the summer and increasing energy costs. However, the performance of window itself is not sufficiently controllable parameter to control thermal comfort and solar radiation. Therefore, a shading device such as venetian blind is required to control them and thus a variety of studies have been performed thus far. So, the purpose of this study is to improve the performance of blind through the development of blind control algorithm. Method: Among various input variables for the control of venetian blinds, the vertical solar radiation has been selected in this study as the primary input variable and the optimal control algorithm for venetian blinds were developed for each window orientation. Result: The developed optimal control algorithm has a positive effect on building energy savings.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance (재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략)

  • Oh, Myung-Hwan;Yoon, Jong-Ho;Shin, U-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

A Elicitation Method of Optimum Slat Angle of Fixed Venetian Blind Considering Energy Performance and Discomfort Glare in Buildings (건물에너지성능 및 불쾌현휘를 고려한 고정형 블라인드의 최적 슬랫각도 도출 방법에 관한 연구)

  • Park, Jang Woo;Yoon, Jong Ho;Oh, Myung-Hwan;Lee, Kwang-Ho
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.107-112
    • /
    • 2012
  • The purpose of this study is to determine the optimum slat angle of the venetian blind which was applied at an outer skin of a curtain-wall system. The evaluation of the blind slat angle was performed in terms of the comfortable visual environment and decreased energy consumption. The office building prototype was considered for the analysis and simulation variables include application of blind, blind slat angle and dimming control of lighting. The annual energy consumption and incidence rate of discomfort glare were analyzed using EnergyPlus which is developed by the U. S. Department of Energy for the detailed building energy simulation. As a result, it turns out that when the blind (reflectance: 0.5) was installed, the annual energy consumption was greater than that of the base model. However, when the dimming control was applied, the maximum energy saving of 16.3% could be achieved at a slat angle of $0^{\circ}$. In addition, in case of the base model, the incidence rate of discomfort glare was 84%, while the case of the blind with the slat angle of $0^{\circ}$ showed that the incidence rate of discomfort glare was 42.4%. Consequently, the results showed that the slat angle of $55^{\circ}$ with dimming control was the optimum strategy for the comfortable visual environment and decreased energy consumption.