• 제목/요약/키워드: Blasting-induced vibration

검색결과 67건 처리시간 0.024초

안전관련 구조물 근접시공시 발파진동 허용기준의 적용성에 관하여 (Applicability of Safe Blast Vibration Limits to the Blasting Work near Safety Related Structures)

  • 류창하;서우춘;정소걸;이종림;주광호;이대수
    • 터널과지하공간
    • /
    • 제4권3호
    • /
    • pp.287-296
    • /
    • 1994
  • Safety-related structures of power plants have to be protected against the effects of possible hazards and natural phenomena. Earthquakes are considered a major dynamic design loading as a requirement of plant design, but the effects of blast-induced vibratons are not. Due to the difficulties of obtaining construction site for new plants, following ones are inevitably being built in the site adjacent to existing power plants. Therefore considerable thought has been recently given to the dynamic loading generated by blasting works near the plants. In this paper, discussed is applicability of existing vibration standards and industrial codes to the blasting works near safety related structures. Also evaluated are the parameters for the safe vibration limits such as measure of vibration level, frequency consideration, structure response, propagation equation, etc.

  • PDF

도심지 발파에서 발파진동치의 크기에 영향을 미치는 제요소 (Some factors affecting level of blasting-induced vibration in urban area)

  • Huh, Ginn;Lim, Han uk
    • 기술사
    • /
    • 제23권2호
    • /
    • pp.81-93
    • /
    • 1990
  • 서울 지하철 3,4호선은 고층빌딩, 각종 상점및 문화재등이 위치하고 있는 도심지를 통과하기 때문에 발파로 인한 지반의 진동이 이들 시설물 및 인체에 큰 영향을 미치고 있다. 따라서 지반 진동으로 인한 피해를 방지하기 위하여 발파진동치의 크기를 여측하고, 또 주어진 한계치내에서 지반당 최대 장약량을 산정함으로써 시설물의 피해 방지와 아울러 효과적인 시공을 도모토록 하는데 본 연구의 목적이 있다. 이를 위하여 3,4호선 건설 예정지를 자유면의 수에 따라 1) 오푼컷트 공법에서 바닥파기, 2) 오푼컷트 공법에서 계단발파, 3) 턴널의 심발 발파, 4)심발 발파후의 틴널발파등으로 나누고, 한국에서 생산되는 폭약중 제란틴, 초안폭약, 함수폭약을 위 4가지 조건과 암질이 서로 다른곳 10개 지역을 선정하여 시험발파를 하면서 Sprengneter, VME, Rion 등 진동 측정기로 측정하여, 다음과 같은 결과식을 구하였다. V=K(D / Wb)$^{-n}$ 에서 n 및 k는 각각 1.60-l.78, 48-138이다. 따라서 위 결과식을 이용하여 현장에서 쉽게 장약량등 발파방법을 결정할 수 있도록 nomogram 등을 제시하였다. 이상의 연구 결과를 토대로 효과적인 건설을 할 수 있었기에 금반 그 내역을 발표코저 한다.

  • PDF

도로구조물의 발파진동 허용기준에 관한 연구 (Study on the Allowable Limit of Blasting-induced Vibration for Road Structures and Facilities)

  • 손무락;홍두표;권오철;정연권;황영철;박두희
    • 한국지반공학회논문집
    • /
    • 제30권12호
    • /
    • pp.27-40
    • /
    • 2014
  • 본 논문은 도로구조물 및 시설물들에 대한 발파진동 허용기준들을 도출하고 그 결과를 제시하고자 한 것이다. 본 연구를 위해서 우선 현재 국내 외에서 사용되는 다양한 구조물들에 대한 발파진동 허용기준들에 대해서 조사하였으며, 이를 통해 국내에서 적용되는 발파진동 허용기준들에 관련되는 문제점을 분석하고 이를 해소하기 위한 방안을 제시하였다. 더 나아가 본 연구에서는 국내 외에서 사용되는 다양한 발파진동 허용기준들을 상호 비교 및 분석한 후 교량 및 터널 등의 도로구조물 및 시설물들에 대한 발파진동 허용기준으로서 국내에서 사용할 수 있는 기준들을 구조물별로 제시하였다. 제시된 기준들의 실무적용을 위한 타당성 검증을 위해서 현장에서 계측되고 관측된 발파진동 유발 구조물 피해사례들을 수집한 후 제시된 기준들과 상호 비교분석하였다. 뿐만 아니라 제시된 기준들은 이론적 접근방법 및 수치해석적 방법을 통한 결과들과도 상호 비교분석하였다. 비교분석결과 제시된 도로구조물 및 시설물별 발파진동 허용기준들은 실무적용을 함에 있어서 타당성이 있는 것으로 나타났다. 이와 같은 결과를 통해서 본 연구에서 제시된 기준들은 향후 국내 외 도로구조물 및 시설물들의 발파진동에 따른 피해유무를 판단하기 위한 기준으로서 실무에서 유용하게 활용될 수 있을 것으로 기대된다.

발파진동이 인접한 터널의 콘크리트 라이닝과 록볼트의 안정성에 미치는 영향평가 (Stability Assessment of Concrete Lining and Rock Bolts of the Adjacent Tunnel by Blast-Induced Vibration)

  • 전상수;김두섭;장양원
    • 한국지반공학회논문집
    • /
    • 제23권10호
    • /
    • pp.33-45
    • /
    • 2007
  • 본 연구에서는 발파 시 발생되는 지반진동이 인접한 터널 지보재의 안정성에 미치는 영향을 분석하고, 발파진동에 의한 터널의 역학적 안정성을 허용진동속도를 기준으로 검토하였다. 기존에 제시된 미광무국과 서울지하철에서 제시한 이론식, 그리고 수치해석 프로그램을 사용하여 허용진동속도를 초과하지 않는 발파이격거리를 산정하였고, 발파시 콘크리트 라이닝과 록볼트의 거동을 평가하였다. 콘크리트 라이닝의 구조적 안정성에 미치는 발파진동영향은 미미한 것으로 나타났으나, 록볼트에 미치는 영향은 상대적으로 크다는 것을 알 수 있었다.

154kV 대신 S/S인출 전력구 시험발파 패턴 및 진동, 소음 계측에 의한 기존 CRACK에 미치는 영향 연구 (On the Study of Blasting Vibration, Sound by Measuring Gage Influence to Exist Crack in 154kV Daeshin Electric Cable Tunnel)

  • 강대우;박태원
    • 화약ㆍ발파
    • /
    • 제16권3호
    • /
    • pp.25-34
    • /
    • 1998
  • This area is covered in Andesite of high compression strength and located in PUSAN SEO-KU. There are many old houses around shaft site. So, we must have a cautious blasting operation. A total of 40 blasts were test at DAE-SHIN Shaft site to study the magnitude and frequency characterization of blast-induced vibration. The effect of viblating frequency on structual damage and site-specific scaling to define th empirical equations were also discussed. The result can be summarized as follows: 1. Some empirical equations were obtained. $V=K\{{\frac{D}{W}}1/3\}^{-n}$ where the values for n and K are estimated to be -1.407 to -2.202 and 643.3489 to 7283.2104 respectively. 2. Dominant frequencies at short distance are in the range of about 75.0 to 91.8 Hz, with some exceptions of about 50Hz, Frequencies observed at long distance are in the range of 10 to 2Hz. It is apparent the shift of dominant frequency down to lower levels at long distance.

  • PDF

발파진동으로 인한 조적조 가옥 피해의 임계수준 평가 (Estimation of critical vibration level on structural damage of brick house induced by blasting)

  • 양형식;김남수;전양수;정지문;문승백;조상호
    • 터널과지하공간
    • /
    • 제9권1호
    • /
    • pp.72-77
    • /
    • 1999
  • 구조물의 피해판정을 위하여 환경변화를 감안한 새로운 판정방법을 제안하였다. 농어촌 조적조 가옥에 대한 시험결과, 구조물 피해를 유발하는 발파진동 수준은 허용 발파진동설계를 위한 0.5 kine 보다 10배 이상의 높은 진동수준이었다.

  • PDF

Development of a new explicit soft computing model to predict the blast-induced ground vibration

  • Alzabeebee, Saif;Jamei, Mehdi;Hasanipanah, Mahdi;Amnieh, Hassan Bakhshandeh;Karbasi, Masoud;Keawsawasvong, Suraparb
    • Geomechanics and Engineering
    • /
    • 제30권6호
    • /
    • pp.551-564
    • /
    • 2022
  • Fragmenting the rock mass is considered as the most important work in open-pit mines. Ground vibration is the most hazardous issue of blasting which can cause critical damage to the surrounding structures. This paper focuses on developing an explicit model to predict the ground vibration through an multi objective evolutionary polynomial regression (MOGA-EPR). To this end, a database including 79 sets of data related to a quarry site in Malaysia were used. In addition, a gene expression programming (GEP) model and several empirical equations were employed to predict ground vibration, and their performances were then compared with the MOGA-EPR model using the mean absolute error (MAE), root mean square error (RMSE), mean (𝜇), standard deviation of the mean (𝜎), coefficient of determination (R2) and a20-index. Comparing the results, it was found that the MOGA-EPR model predicted the ground vibration more precisely than the GEP model and the empirical equations, where the MOGA-EPR scored lower MAE and RMSE, 𝜇 and 𝜎 closer to the optimum value, and higher R2 and a20-index. Accordingly, the proposed MOGA-EPR model can be introduced as a useful method to predict ground vibration and has the capacity to be generalized to predict other blasting effects.

터널 발파로 인한 아파트 인근지역에서의 지반진동 전파특성 및 영향 평가 연구 (Environmental Effects and Characteristics of Ground Vibration Caused by Tunnel Blasting in the Vicinity of an Apartment)

  • 최병희;류창하;백승규
    • 화약ㆍ발파
    • /
    • 제22권1호
    • /
    • pp.57-65
    • /
    • 2004
  • 화약발파를 이용한 터널굴착은 지반진동 및 소음과 같은 발파공해적 요소가 수반됨으로써 주위 환경조건에 따라 여러 가지 형태의 피해를 유발할 수 있으며 시공 중에 종종 발생하는 민원의 주요 원인이 되고 있다. 본 연구는 터널 건설과정에서 노선이 통과하는 직상부 지역에 위치한 민가들과 인근의 아파트를 대상으로 발파로 인한 지반진동의 영향여부를 검토함으로써 사전에 발파작업으로부터의 안전성을 확보할 수 있는 근거를 마련코자 실시되었다. 먼저, 대상지역에 위치한 건물들에 대한 발파진동 허용수준은 보수적인 관점에서 0.5cm/sec를 관리수준으로 설정하였고, 터널 굴착과정에서 발생하는 발파진동 발생특성을 실측하기 위하여 총 6회의 굴진 발파에 대하여 총 70개소 이상의 측점에서 현장계측을 실시하였다. 발파진동 영향평가에서는 현장계측으로부터 획득한 자료들을 처리하여 발파로 발생하는 최대진동수준을 예측하기 위한 전파식들을 지상과 지하의 계측장소별로 유도하였다. 지반진동의 영향여부를 결정하기 위한 진동 예측식은 엄격한 기준을 적용하여 전체자료의 95%를 포함하는 식을 채택하였고, 지표 및 지하터널에 대해 각기 별도의 식을 사용할 것을 제안하였다.

터널굴착이 지상구조물에 미치는 영향평가 및 발파지침설계 (Ground Vibration in Tunnelling by Blasting and its Effect on Surface Structures)

  • 신희순;한공창;류창하;신중호;박연준;최영학
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.463-470
    • /
    • 2000
  • In tunnel excavation by blast beneath the surface structures in urban area, the characteristics of ground vibration induced by blast and its influence on surface structures are analyzed by the field test and the numerical analysis on dynamic behaviors of the structure. According to the field test on the propagating characteristics of blast vibration through the rock mass and the concrete foundation pile. the attenuation index of peak particle velocity with distance shows the range of 1.7∼2.0 for the rock mass and the range of 2.0∼2.3 for the concrete pile. This shows that the blast vibration reduces more rapidly in the concrete pile. It is known from the numerical analysis on dynamic behavior of the structure that the coefficient of response, velocity ratio of structure response to input wave, is different according to the story of the structure. It can be said from this research that the characteristics of the ground vibration and the dynamic behavior of the structure should be well evaluated and be considered as important factors for safe blasting design especially in underground excavation at shallow depth in urban area.

  • PDF

바위갯지렁이 양식장 인접지역 계측 사례를 포함한 수중소음 피해인정기준에서 배경소음과의 차에 대한 문제점 (Study on the Acceptance Level for Damage due to Underwater Noise from the Case Study of Field Measurement at Marphysa sanguinea Farm)

  • 최태홍;김재웅;고진석
    • 화약ㆍ발파
    • /
    • 제35권1호
    • /
    • pp.34-42
    • /
    • 2017
  • 발파에 의한 소음 진동의 물리적 크기 이외에 영향을 미치는 대상의 응답조건, 주변 환경에 적응상태 및 주관적 감정, 정신적 상태 등에 따라 크게 좌우되는 특성을 가지고 있어 명확히 피해영향을 판단하는 것은 매우 어려운 일이다. 특히 어류의 피해영향에 대해서는 실험을 통한 연구자체도 어렵고, 적용할 수 있는 제시기준이 모호하여 정확한 평가방법은 물론 실제 소음 진동 노출정도의 예측에 많은 어려움이 있다. 국내의 경우 수중소음 피해인정 기준을 140 dB re $1{\mu}Pa$, 수중 배경음과의 차가 어류에 미치는 피해기준은 20 dB re $1{\mu}Pa$ 이상으로 규정하고 있으나, 이는 연속음에 대한 것으로서 충격음인 발파음에 대한 평가로서는 적합하지 않다. 이 연구에서는 시험발파를 통해 바위갯지렁이 양식장 주변에서 발파 시 진동속도와 수중소음의 관계를 예측해보았다. 그리고 수중소음 피해인정기준에서 배경소음과의 차에 대한 의견을 제시해 보고자 한다.