• Title/Summary/Keyword: Bladder Pressure

Search Result 57, Processing Time 0.028 seconds

Radionuclide Cisternographic Findings in Patients with Spontaneous Intracranial Hypotension (자발성 두개내 저압 환자의 방사성 동위원소 뇌조조영술 소견)

  • Jung, Dong-Jin;Kim, Jae-Seung;Ryu, Jin-Sook;Shin, Jung-Woo;Im, Joo-Hyuk;Lee, Myoung-Chong;Jung, Sun-Joo;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.482-489
    • /
    • 1998
  • Purpose: Radionuclide cisternography may be helpful in understanding pathophysiology of postural head-ache and low CSF pressure in patients with spontaneous intracranial hypotension. The purpose of this study was to characterize radionuclide cisternographic findings of spontaneous intracranial hypotension. Materials and Methods: The study population consists of 15 patients with spontaneous intracranial hypotension. Diagnosis was based on their clinical symptoms and results of lumbar puncture. All patients underwent radionuclide cisternography following injection of 111 to 222 MBq of Tc-99m DTPA into the lumbar subarachnoid space. Sequential images were obtained between 112 hour and 24 hour after the injection of Tc-99m DTPA. Radioactivity of the bladder, soft tissue uptake, migration of radionuclide in the subarachnoid space, and extradural leakage of radionuclide were evaluated according to the scan time. Results: Radionuclide cisternogram showed delayed migration of radionuclide into the cerebral convexity (14/15), increased soft tissue uptake (11/15), and early visualization of bladder activity at 30min (6/10) and 2hr (13/13). Cisternography also demonstrated leakage site of CSF in 4 cases and 2 of these were depicted at 30min. Epidural blood patch was done in 11 patients and headache was improved in all cases. Conclusion: The characteristic findings of spontaneous intracranial hypotension were delayed migration of radionuclide and early visualization of the soft tissue and bladder activity. These scintigraphic findings suggest that CSF leakage rather than increased CSF absorption or decreased production may be the main pathophysiology of spontaneous intracranial hypotension. Early and multiple imaging including the bladder and soft tissue is required to observe the entire dynamics of radionuclide migration.

  • PDF

Soft Tissue Sarcomas Originating from Retroperitoneal Cavity in a Maltese Dog (후복강에서 기원한 비혈관성 연부조직 육종 증례)

  • Shin, Jung-Min;Park, Seuingjo;Lee, Sang-Kwon;Choi, Jihye
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.115-119
    • /
    • 2015
  • An 11-year-old spayed female maltese was presented for abdominal distention, dysuria and dyschezia. Panting and heart murmur was found and abdominal palpation was difficult due to increased abdominal pressure. A soft tissue mass, $6{\times}3cm$ in size, was identified radiographically in pelvic canal, displacing the descending colon to the medioventral direction and the urinary bladder cranially. On ultrasonography, the mass consisted of homogeneous hypoechoic parenchyma containing the focal hyperechoic region ($1.6{\times}1.5cm$). The mass had distinct margin and no connection with adjacent organs. It was considered as a mass originating from the retroperitoneal cavity. Additional diagnostic procedures were not advanced because of the owner's request, and only a surgical excision of the mass was performed to alleviate the dysuria and dyschezia. Histopathologic examination and immunohistochemistry determined the mass as a soft tissue sarcoma and excluded hemangiosarcoma and osteosarcoma, both are the most common types of the retroperitoneal tumors. This report described non-vascular soft tissue sarcoma originating from the retroperitoneal cavity in a maltese dog.

One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System (휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩)

  • Park, Sin-Wook;Kang, Tae-Ho;Lee, Jun-Hwang;Yoon, Hyun-C.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

Traumatic urethra injury presenting as urethral cancer : A case study (외상성 요도 손상으로 오인된 요도암)

  • Shin, Sang-Yol;Hwang, Yong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.147-154
    • /
    • 2020
  • Purpose: The purpose of the study was to investigate traumatic urethral injury in a 63-year-old patient with hematuria. Methods: A hematuria patient was transferred by paramedics. At the time of the visit, the patient's blood pressure (151/91mmHg), pulse rate (86/min), body temperature (37.1℃), and other vital signs were stable. Their KTAS (Korean Triage and Acuity Scale) was Level 4. The patient had no damage to the injured area, but a large contrast defect was observed between the prostate urethra and the bladder in urethral angiography performed due to persistent hematuria and pain in the injured area. Results: Following radiological evaluation of a suspected liposarcoma or neuroma mass of the prostate urethra, the mass was removed through urethral tumor resection. The result of histologic evaluation provided a diagnosis of highly differentiated invasive urethral cell carcinoma that had invaded the muscle layer. The patient was given additional treatment for urethral cancer but was rejected and is currently being followed. Conclusion: The prognosis for urinary tract cancer has distinct differences for patients with lymph node metastasis and tumor characteristics. The presence or absence of urethral cancer should be confirmed through angiography, CT, MRI, and cystoscopy.

Use of Home Nursing Therapy and Need of Home Care Equipments (가정간호환자의 치료적 간호서비스 제공과 의료기구 사용 및 요구도)

  • Ryu, Ho-Shin;Park, Chai-Soon;Kim, In-A;Kwon, Young-Dae;Kang, Sung-Wook
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.2
    • /
    • pp.157-166
    • /
    • 2008
  • This study was conducted with whole home care nurses nationwide to provide secondary analyzed data to understand on their usage of medical equipments and their need of them for a month. This study found that treatments given by home care nurses were nelaton catheterization, bladder washing/urethral washing, newborn care, exchange and care for nasogastric tube and suction in that order of frequency. Second, instruments and equipments used for home care were reported to be stethoscope, patient monitor, blood pressure measuring equipment, air flotation mattresses, beds for patients, mattresses, suctioning device sets, enteral feeding equipment and dressing set in that oder of frequency. Moreover, need assessment of medical instruments and equipments showed renal dialysis was most needed and patient monitor, blood pressure measuring equipment, enteral feeding equipment, solution and other supplies for renal dialysis and beds for patient were necessary in that order. In conclusion, the results of this study investigating special treatments and medical instruments and equipments used for home care patients and analyzing patients' need, were expected to be useful for expansion of application of long-term care insurance for the elderly and health insurance as well as for quality control of home care and development of medial instruments and equipments used at home.

  • PDF

Proposal of Urinary Incontinence Treatment Program Using Moosim Gi-Gong Riding stance. (무심 기공 선자세를 활용한 요실금 치료 프로그램 제안)

  • Lee, Se Won;Lee, Jae Heung;Bae, Jae Ryong;Chui, Eun Geung;Park, Jung Eun;Kang, Han Joo
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.17 no.1
    • /
    • pp.83-108
    • /
    • 2017
  • Objects : The purpose of this study was to investigate Urinary Incontinence improvement effect of Moosim Gi-Gong Riding stance and to propose urinary incontinence treatment Program. Methods : We analyzed the effect of Moosim Gi-Gong Riding stance, and compared to Behavior theraphy which includes Kegel Exercise, Riding Stance of Ki-chum, Zhan-Zhuang-Gong. Results : 1. Moosim Gi-Gong Riding stance can correct the pelvic strain with principles such as horseback riding and help restore organs in the abdominal cavity. 2. Moosim Gi-Gong Riding stance can restore the ability to recover bladder and proximal urethra in right place through changes in the abdominal pressure by breathing and posture 3. Moosim Gi-Gong Riding stance can help restoring the ability to control the urination by increasing the intensity of the abdominal pressure and reinforcing Kidney, Liver, Spleen Meridian muscles. 4. Reinforcing Kidney, Liver, Spleen Meridian muscles can help to treat urinary incontinence through strengthening the tension between organs and activating the intestinal tract. Conclusions : This study shows that treatment program for Urinary Incontinence using Moosim Gi-Gong Riding stance can be useful to patient.

The Comparison of the Effectiveness of Pelvic Floor Muscle Exercise and Biofeedback Treatment for Stress Incontinence in Korean Women (한국여성의 복압성요실금에 대한 골반저근육훈련운동과 바이오피드백요법의 효과 비교)

  • 최영희;성명숙;홍재엽
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.1
    • /
    • pp.34-47
    • /
    • 1999
  • This study evaluated the Comparison of the Effectiveness of Pelvic Floor Muscle exercise and Biofeedback treatment for Genuine Stress Incontinence I assigned 60 participants to 2 groups : 30 to the pelvic floor muscle exercise group and 30 to the biofeedback group. Treatment protocol lasted for 6 weeks. Peak pressure, and duration time of pelvic muscle contraction were evaluated by a perineometer. Lower urinary symptoms, sexual matter and life style scores were achieved by using Jackson's scale. The treatment efficacy of the pelvic floor muscle exercise is compared with the biofeedback group and the main results of the comparison are as follows : 1. Pelvic muscle contraction 1) The peak pressure in the biofeedback group was significantly increased(P=0.000). 2. The frequency and quantity of incontinence 1) The frequency of incontinence in the biofeedback group was significantly decreased(P=0.000). 2) The quantity of incontinence in the biofeedback group was significantly decreased(P=0.000). 3. The lower urinary symptoms Daily frequency(P=0.000), nocturia(P=0.000), urgency(P=0.000), bladder pain(P=0.000), unexplained incontinence(P=0.048), wearing protection(P=0.022), changing outer clothing(P=0.005), hesitancy(P=0.008), intermittent stream(P=0.000), abnormal strength of stream(P=0.004), retention(P=0.000), incomplete emptying(P=0.000), and inability to stop mid stream(P=0.006) of the lower urinary symptoms in the biofeedbatk group were significantly decreased. 4. The sexual matters The dry vagina (P=0.004) and pain during sexual Intercourse (P=0.002) in the biofeedback group was significantly decreased. 5. The life style The fluid intake restriction(P=0.007), affected daily task(P=0.003), avoidance of places & situation(P=0.003), interference in Physical activity (P=0.002), interference in relationship with other people(P=0.01), and feeling about the rest of life with urinary symptom(P=0.000) in the biofeedback group were significantly decreased. In conclusion, the biofeedback treatment was more effective than the pelvic floor muscle exercise in genuine stress incontinence.

  • PDF

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Effects of Transcutaneous Electrical Stimulation on Physiological Symptoms and Psychological Satisfaction in Women With Stress Urinary Incontinence: A Preliminary Study

  • Kim, Ji-hyun;Kwon, Oh-yun;Jeon, Hye-seon;Hwang, Ui-jae;Gwak, Kyeong-tae;Yoon, Hyeo-bin;Park, Eun-young
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.67-75
    • /
    • 2019
  • Background: Stress urinary incontinence (SUI) is an involuntary leakage of urine from the urethra when intra-abdominal pressure increases, such as from sneezing, coughing, or physical exertion. It is caused by insufficient strength of the pelvic floor and sphincter muscles, resulting from vaginal delivery, obesity, hard physical work, or aging. The pelvic floor electrical stimulator is a conservative treatment generally used to relieve the symptoms of urinary incontinence. it recommended to applied before surgery is performed. Objects: The purpose of this study was to determine if the transcutaneous electrical stimulation (TCES) would be effective for the physiological symptoms and psychological satisfaction of women with SUI for an 8-weeks intervention. Methods: Easy-K is a specially designed user-friendly TCES. Five female who were diagnosed with SUI by a gynecologist but who did not require surgical intervention were included in this study. Intervention was implemented over an 8-week period. Outcome measures included vaginal ultrasonography, Levator ani muscle (LAM) contraction strength, incontinence quality of life (I-QOL), and female sexual function index (FSFI) questionnaires. Results: The bladder neck position significantly decreased across assessment time. Funneling index and urethral width significantly decreased after 8 weeks of intervention (p<.05). The bladder necksymphyseal distance and posterior rhabdosphincter thickness statistically increased and the anterior rhabdosphincter thickness showed a tendency to increase. All participants demonstrated a significant increase in the LAM contraction score across three assessment times (p<.05). Although the total score of the I-QOL did not show significant improvement, it steadily increased and among I-QOL subscales, only the "avoidance" subscale showed statistical improvements (p<.05). The total score of the FSFI statistically improved and the "desire" score significantly changed (p<.05). Conclusion: The TCES is recommended for women who want to apply conservative treatments before surgery and who have suffered from SUI in aspects of sexual function and quality of life.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF