• Title/Summary/Keyword: Biting force

Search Result 32, Processing Time 0.022 seconds

Effects of Occlusal Condition and Clenching Force on the Mandibular Torque Rotational Movement (교합조건 및 이악물기 힘의 변화가 하악의 비틀림 회전운동에 미치는 영향)

  • Oh, Min-Jung;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.411-426
    • /
    • 2005
  • The purpose of this study was to investigate the effects of occlusal condition and clenching level on the mandibular torque rotational movement. For this study, healthy 14 men without any symptoms and signs of temporomandibular disorders were selected. Mandibular torque rotational movement was observed in each circumstance of combination of three occlusal conditions such as natural dentition, with wafer of 3.6 mm thickness, and wafer with resin stop of 14 mm thickness total during hard biting of bite stick at maximum voluntary contraction(MVC) and 50% of MVC level of surface EMG activity of masseter muscle. Electromyographic activity and mandibular torque rotational movement were observed using BioEMG and BioEGN in $BioPak^{(R)}$ system. Each biting movement in each circumstance was composed of clenching one time and hard biting of wooden stick two times. The observed items were opening distance, velocity and amount of torque rotational movement in mandibular movement, and the data were statistically processed with $SPSS^{(R)}$ windows (ver.10.0). The results of this study were as follows: 1. There were no differences in the mandibular movement distance between those value in both biting sides, and between those in both clenching forces, but the mandibular velocity showed a different results by clenching force. For the amount of torque rotational movement, there were no difference in the value of the frontal plane but some significant difference was in the value of the horizontal plane by biting side. 2. The mandibular movement distance and the mandibular velocity in both planes were higher by maximum voluntary contraction than those by half maximum voluntary contraction, and amount of torque rotational movement in the horizontal plane was also increased by maximum voluntary contraction. 3. The opening distance in both planes were decreased with the increase of vertical dimension of occlusion, namely, by the occlusal appliances, and this pattern was also showed in the mandibular velocity in case of hard biting by maximum voluntary contraction. However, the amount of torque rotational movement were not different by the increase of vertical dimension of occlusion. 4. The value of angle and distance of the torque rotational movement in the hard biting of wooden stick were generally higher than those in the clenching without wooden stick in both planes without regard to occlusal conditions and/or clenching forces.

Seasonal Abundance of Culicoides at Yongsan US Army Garrison (USAG) and Camp Humphreys USAG, Republic of Korea, 2010-2013 and 2014-2017

  • Kim, Myung-Soon;Kim, Heung Chul;Bellis, Glenn A.;Chong, Sung-Tae;Kim, Hyo-Sung;Klein, Terry A.
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.3
    • /
    • pp.273-280
    • /
    • 2021
  • Biting midges (Culicoides: Ceratopogonidae) were collected using New Jersey light traps at Yongsan US Army Garrison (USAG;urban), Seoul Metropolitan city and Camp Humphreys USAG (rural), Pyeongtaek, Gyeonggi-do (province), Republic of Korea , from May-October 2010-2013 and 2015-2017, to determine species composition and seasonal distribution patterns in urban and rural habitats. A total of 9,958 female (53.85%) and 8,533 male (46.15%) Culicoides comprising 16 species were collected. Overall, the most commonly collected species was Culicoides arakawae (74.3%), followed by C. circumscriptus (16.2%), C. kibunensis (2.5%), C. nasuensis (2.2%), C. clavipalpis (1.4%), and C. pallidulus (1.3%), while the remaining 10 species accounted for <2.1% of all Culicoides spp. collected. The 2 predominant species collected were C. circumscriptus (47.4%) and C. arakawae (33.4%) at Yongsan, and C. arakawae (90.4%) and C. circumscriptus (3.9%) at Camp Humphreys. The seasonal abundance of these 2 species varied between years and between sites but on average peaked in August-September for C. arakawae and June-July for C. circumscriptus. Annual variations in abundance were observed for most species collected during this study. Unusually high proportions of male specimens were observed for most species at both sites which may be due to the use of the New Jersey trap.

Seasonal Abundance of Biting Midges, Culicoides spp. (Diptera: Ceratopogonidae), Collected at Cowsheds in the Southern Part of the Republic of Korea

  • Kim, Heung-Chul;Bellis, Glenn A.;Kim, Myung-Soon;Chong, Sung-Tae;Lee, Dong-Kyu;Park, Jee-Yong;Yeh, Jung-Yong;Klein, Terry A.
    • Parasites, Hosts and Diseases
    • /
    • v.50 no.2
    • /
    • pp.127-131
    • /
    • 2012
  • Black light traps were used to measure the seasonal and geographical distribution of Culicoides spp. (biting midges or no-see-ums) at 9 cowsheds in the southern half of the Republic of Korea (ROK) from June through October 2010. A total of 25,242 Culicoides females (24,852; 98.5%) and males (390; 1.5%) comprising of 9 species were collected. The most commonly collected species was Culicoides punctatus (73.0%) followed by C. arakawae (25.7%), while the remaining 7 species accounted for <1.0% of all Culicoides spp. collected. The mean number of Culicoides spp. collected per trap night (Trap Index [TI]) was highest for C. punctatus (409.3), followed by C. arakawae (144.2), C. tainanus (4.1), C. oxystoma (1.2), C. circumscriptus (0.7), C. homotomus (0.6), C. erairai (0.4), C. kibunensis (0.3), and C. nipponensis (0.04). Peak TIs were observed for C. punctatus (1,188.7) and C. arakawae (539.0) during July and August, respectively. C. punctatus and C. arakawae have been implicated in the transmission of arboviruses and other pathogens of veterinar importance that adversely impact on animal and bird husbandry.

The Effects of Quantitative Occlusal Force on Size of Temporomandibular Joint Space (정량적 교합력이 측두하악관절강 크기에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.18 no.1
    • /
    • pp.21-29
    • /
    • 1993
  • The purpose of this study was to evaluation of temporomandibulr joint space according to increasing the occlusal force on working and non-working side during unilateral bite. For the study, 22 normal adults, age ranged from 23 to 25, who had no symptoms on TMJ area and masticatory muscles and had normal or class I molar relationship were selected. Transcranial TMJ radiograph was taken during unilateral biting with sensor of Bite force checker (Nihon Kohden Kygyo Co.Ltd., Japan) on each 1st molar teeth of right and left side which were forced each 0Kg, 10Kg, 20Kg and 30Kg by use of Accurad-200 (Denar Corperation's product). The radiographs were traced on the screen, which was magnified by 5. The size of temporomandibular joint space at anterior, superior and posterior compartment were measured with Dumas's method (reference line of between squamotympanic fissure and the most inferior point of articular eminence). On the basis of this study, the following results were obtained. 1. Size of anterior TMJ space was tend to decrease on the working side and increase on the non-working side according to increasing the occlusal force, but not significant statistically (p>0.05). 2. Size of superior TMJ space was tend to increase on the working side and decrease on the non-working side according to increasing the occlusal force (p<0.05). 3. Size of posterior TMJ space was tend to decrease on both working ad nonworking side, but non significant statistically.

  • PDF

COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH (골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교)

  • Kwon Young-Sook;Hwang Sun-Hong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

A STUDY OF THE RELATIONSHIP BETWEEN TOOTH MOBILITY AND BITE FORCE ACCORDING TO THE PERIODONTAL DISEASE SEVERITY (치주질환 심도에 따른 치아동요도와 교합력의 상관관계에 관한 연구)

  • Choi, Joug-Woo;Lee, Man-Sup;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.2
    • /
    • pp.331-344
    • /
    • 1993
  • The purpose of this study was to investigate the change of tooth mobility and bite force according to periodontal disease severity. Tooth mobility and biting force due to change of viscoelastic property of periodontium were influenced by inflammation of periodontal tissue. 30 patients participated in this study, the periodontal disease severity is evaluated with SBI and attachment loss. SBI and attachment loss were examined by periodontal probe. Tooth mobility was tested two times to each tooth using periotest (Siemens Co, Germany) and bite force was evaluated with MPM-3000 (Nihon Kohden Co, Japan). Statistical analysis was applied to correlation ($r^2$) and regression analysis. The obtained results were as follows : 1. As the attachment loss increased, tooth mobility increased with significance, and they had highly positive correlation ($r^2=0.68$) on entire dentition. 2. As the SBI increased, tooth mobility increased with significance, and they had positive correlation ($r^2=0.37$) on entire dentition. 3. As the attachment loss increased, bite force decreased with significance, and they had highly negative correlation ($r^2=0.42$) on maxillary anterior dentition but low negative correlation ($r^2=0.20$) on the other portion of dentition. 4. As the SBI increased, bite force decreased with significance, and they had highly negative correlation ($r^2=0.31$) on maxillary anterior dentition but low negative correlation ($r^2=0.16$) on the other portion of dentition. 5. As tooth mobility increased, bite force decreased with significance, and they had highly negative correlation ($r^2=0.32$) on maxillary anterior dentition but low negative correlation ($r^2=0.16$) on the other portion of dentition.

  • PDF

STUDY ON VERTICAL DISPLACEMENT OF SOFT TISSUE UNDER DISTAL EXTENSION PARTIAL DENTURE BASE BY FUNCTIONAL IMPRESSION (유리단 국소의치의 기능 인상에 의한 연조직의 수직적 변위량에 관한 연구)

  • Lee, Kwang-Hee;Chang, IK-Tai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.21 no.1
    • /
    • pp.59-66
    • /
    • 1983
  • Distal extension partial dentures are supported by both the relatively rigid teeth and the resilient mucosa. So impression techniques of residual alveolar ridge in case of distal extension partial denture have particular importance in order to broad distribution of the masticatory force. McLean recognized the need for recording the tissues supporting distal extension partial denture base in functional form to equalize the resilient and non-resilient support, and this was called functional impression. Many investigators proposed various techniques of the functional impression for a distal extension partial denture, but only a little studies were performed about displacement of soft tissue under distal extension partial denture base. The purpose of this study is to investigate the amount of vertical displacement of the soft tissue under distal extension partial denture base by different functional impression techniques. Impression techniques used were Z.O.P. Impression, Selective Tissue Placement Impression, Functional Relining Impression. Measurement of the vertical displacement of soft tissue were made with Depth Gauge and Measuring Platform. A Anatomic Impression was used as a control. The results were tested statistically using 3 way ANOVA and Scheffe test. The followings were the results obtained from this study. 1. The greatest amount of soft tissue displacement was observed in the center of the retromolar pad. 2. No significant differences were found between the crest of alveolar ridge and the buccal shelf area. 3. The greatest soft tissue displacement was observed in Functional Relining Impression using Iowa wax, and the least displacement was observed in Selective Tissue Placement Impression using murcaptan rubber base. 4. No significant differences were found between finger pressure and biting pressure in Z.O.P. Impression, but greater displacement was observed by biting pressure than finger pressure in Functional Reling Impression.

  • PDF

Development of Milking Machine for Human with Reference to human Babies' Behavior

  • Kawamura, Takashi;Morichika, Masayuki;Nakazawa, Masaru
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.203-205
    • /
    • 2000
  • This paper deals with human nursing and milking. We have made clear the principle of milking of human babies that consists of biting force, sucking pressure and movement of tongue. Base on this observation, the tongue mechanism was proposed. Then new type milking machine was developed and helpful milking was realized by controlling it with reference to human babies behavior. The experimental result of milking from nursing bottles and breast of mothers are shown in this paper. According to the result, the machine has almost same ability as babies.

  • PDF

A 3-dimensional Finite Element Analysis of Stress Distribution in the Supporting Bone by Diameters of Dental Implant Fixture (골유착성 치과 임플랜트 고정체 직경에 따른 지지골의 응력분포에 관한 삼차원 유한요소 분석적 연구)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2004
  • The objective of this finite element method study was to analyze the stress distribution induced on a supporting bone by 3.75mm, 4.0mm, 5.0mm diameter of dental implant fixture(13mm length). 3-dimensional finite element models of simplified gold alloy crown(7mm height) and dental implant structures(gold cylinder screw, gold cylinder, abutment screw, abutment, fixture and supporting bone(cortical bone, cancellous bone) designs were subjected to a simulated biting force of 100 N which was forced over occlusal plane of gold alloy crown vertically. Maximum von Mises stresses(MPa) under vertical loading were 9.693(3.75mm diameter of fixture), 8.885(4.0mm diameter of fixture), 6.301(5.0mm diameter of fixture) and the highest von Mises stresses of all models were concentrated in the surrounding crestal cortical bone. The wide diameter implant was the good choice for minimizing cortical bone-fixture interface stress.

  • PDF

Finite Element Analysis on Stress Distribution in Base Metal-Ceramic Crown Margin Designs (유한요소법을 이용한 비귀금속-도재관 변연부 형태에 따른 응력 분포 분석)

  • Lee, Myung-Kon;Shin, Jung-Woog;Kim, Myung-Duk
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.79-88
    • /
    • 2000
  • The objective of this finite element method study was to analyze the stress distribution induced in a maxillary central incisor Ni-Cr base metal coping ceramic crowns with various margin design. Margin designs of crown in this experiment were knife-edge metal margin on chamfer finishing line of tooth preparation(M1), butt metal margin on shoulder finishing line(M2), reinforced butt metal margin on shoulder finishing line(M3), beveled metal margin on bevelde shoulder finishing line(M4). Two- dimensional finite element models of crown designs were subjected to a simulated biting force of 100N which was forced over porcelain near the lingual incisal edge. Base on plane stress analysis, the maxium von Miss stresses(Mpa) in porcelain venner was 0.432, in metal coping was 0.579, in dentin abutment was 0.324 for M1 model, and M2 model revealed in porcelain was 0.556, in metal coping was 0.511, in dentin was 0.339, and M3 model revealed in porcelain was 0.556, in metal coping was 0.794, in dentin was 0.383 for M4 model. All values of each material in metal-ceramic crown were much below the critical failure values.

  • PDF