• Title/Summary/Keyword: Birdcage-type coil

Search Result 7, Processing Time 0.019 seconds

FPCB-based Birdcage-Type Receiving Coil Sensor for Small Animal 1H 1.5 T Magnetic Resonance Imaging System (소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서)

  • Ahmad, Sheikh Faisal;Kim, Hyun Deok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.245-250
    • /
    • 2017
  • A novel method to implement a birdcage-type receiving coil sensor for use in a magnetic resonance imaging(MRI) system has been demonstrated employing a flexible printed circuit board (FPCB) fabrication technique. Unlike the conventional methods, the two-dimensional shape of the coil sensor is first implemented as a FPCB and then it is attached to the surface of a cylindrical supporting structure to implement the three-dimensional birdcage-type coil sensor. The proposed method is very effective to implement object-specific MRI coil sensors especially for small animal measurements in research and preclinical applications since the existing well-developed FPCB-based techniques can easily meet the requirements on accuracies and costs during coil implement process. The performances of the coil sensor verified through $^1H$ 1.5T MRI measurements for small animals and it showed excellent characteristics by providing a high spatial precision and a high signal-to-noise ratio.

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2002
  • We authors developed a new small-size birdcage RF coil for animal MR images. And we compared signal-to-noise ratio (SNR) of the new small coil with a conventional knee coil. The dimension of the low-pass type birdcage coil with 12 elements at 37 MRI system are 13 cm outer diameter, 12 cm inner diameter and 20 cm length. For each element, the width of copper tape is 0.05 mm, thickness is 8 mm and length is 20 cm. The small birdcage coil with 12 elements exhibited 7 resonance modes. The isolation of the quadrature channel could be achieved more than 20 ㏈. The coil quality factor (Q value) was 98.6. The SNR of the animal coil was 243.2 on the average and was about twice as high as the conventional knee coil. The present study successfully demonstrated that the small birdcage coil could provide high quality animal MR images with the improved SNR. Therefore, it is expected that the small birdcage coil could be used in the clinical diagnosis and research studies for veterinary medicine in the near future.

  • PDF

FDTD 방법을 이용한 3T MRI용 RF 코일의 해석

  • 이종오;박준서;명노훈;박부식;김용권;정성택
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.976-983
    • /
    • 2000
  • In this paper, Bridcage type RF coils used widely as RF coils for MRI and its applicable type, spiral type RF coil are analyzed and designed using FDTD method. In low tesla (IT, 1.5T) MRI system, several tools have been used for the analysis and design of the RF coils for MRI. This includes, so-called, LC equivalent circuit method for predicting the resonance frequency of the coil and the Biot-Savart law to determine the field distribution within the coil. Both of the circuit analysis and Biot-Savart law are low frequency techniques. Therefore, at high frequency applications, the circuit model approximation breaks down because the coil geometry is a significant fraction of the wavelength. In this paper, we analyzed and designed RF coils for 3T MRI using FDTD method. This method is a full wave analysis and very accurate at low and high frequencies. Also, this RF coils are actually fabricated and FDTD models of RF coils for MRI are proven.

  • PDF

Development of Quadrature Detection Surface Coil for Functional Magnetic Resonance Imaging at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.363-364
    • /
    • 2002
  • We describe quadrature type surface coil for functional magnetic resonance imaging at 3T MRI system. The coil consisted of two coplanar resonators and was used as both transmitter and receiver. The signal-to-noise ratio (SNR) of the coil was compared with that of a standard birdcage head coil. Visual cortex activation on normal subjects using LED flicker was performed. The SNR of surface coil was found to be better than that of the conventional head coil.

  • PDF

A New Quadrature Breast RF Coil for MRI (새로운 자기공명영상촬영용 Quadrature Breast RF 코일)

  • Kim, S.K.;Yang, Y.J.;Lee, D.R.;Yi, Y.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.291-293
    • /
    • 1997
  • A new quadrature RF coil is designed for Breast MR Imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by "$\sqrt{2}$" using two orthogonal RF coils in combination. A modified Breast Quadrature coil is designed. It is a modified type of the high-pass birdcage coil. To reduce the field distortion, by using current feeding, the field pattern is optimized to achieve a quadrature circularly-polarized field pattern. The coil has been implemented for receive-only mode, and tested by phantom imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

Actively-Shielded Brain-Only $R^{2}$-Gradient Coil for Localized MRI/MRS (Localized MRI/MRS를 위한 차폐된 두뇌촬영용 $R^{2}$-경사자계코일)

  • Oh, C.H.;Yang, Y.J.;Kim, S.K.;Yi, Y.;Lee, H.K.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.161-164
    • /
    • 1996
  • An actively-shielded $r^{2}$-gradient coil has been developed for brain localized MRI or MRS. Spatial localization is very useful for spatial volume selection in MRI or MR Spectroscopy(MRS). The radial(or $R^{2}-$) gradient coil is useful in reducing the artifact or in improving the SNR by selecting the volume with less number of RF pulses. It is, however, difficult to implement the coil with a gradient intensity strong enough to use it for practical whole-body MRI system. For example, the smallest volume size for selection is just 6 cm in diameter with a 250 Ampere of current driving for a whole-body system (in case of 70-cm-diameter). In this study, an asymetric $r^{2}$-coil with a small diameter of 35 cm has been designed and implemented for brain localized MRI or MRS. An 8-rod high-pass-type birdcage RF coil has also been implemented. The coil set has been developed for 1.0 Tesla Medison MRI system and its performance has been verified experimentally.

  • PDF

Evaluation of Cerebral Cortices Associated with Sexual Arousal in Healthy Male Using BOLD-based Functional MRI

  • Kim, Hyung-Joong;Seo, Jeong-Jin;Kang, Heoung-Keun;Jeong, Gwang-Woo;Park, Jin-Gyoon;Jeong, Yong-Yeon;Chung, Tae-Woong;Woong Yoon;Park, Kwang-Sung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • Purpose: The purpose of this study was to identify cerebral cortices related with sexual arousal fro visual sexual stimulation in healthy males using BOLD-based functional MR imaging Method: Sixteen male volunteers with sexually potent(mean age:24) were examined for thi study. Functional MRI was performed on a 1.5T MR scanner(GE Signa Horizon) with birdcage-type head coil. In this study, blood oxygenation level dependent(BOLD) technique was utilized to create fMR image reflecting local brain activities. The BOLD-based fMRI d were obtained from 7 oblique planes using gradient-echo EPI with $90^{\circ}$flip angle, 50ms TE 6000ms TR, $26cm{\times}26$ cm FOV, $128{\times}128$ matrix, and 10mm slice thickness. The sexual stimulation paradigm consisted of two alternating periods of rest and activati and it began with a 1 minute rest, followed by a 2 minute stimulation by a documentary a erotic video film. Brain activation maps were generated by cross-correlation of imag acquired during rest and activation periods. The index of activation was used to compare t number of pixels activated by each task in each volunteer, where the significance of th differences was evaluated by using Students t-test.

  • PDF