• Title/Summary/Keyword: Biosensors

Search Result 296, Processing Time 0.026 seconds

Fabrication of Polyimide Film Electrode by Laser Ablation and Application for Electrochemical Glucose Biosensor (Laser ablation을 이용한 폴리이미드 필름 전극제조 및 전기화학적 글루코오즈 바이오센서 응용)

  • Park, Deog-Su
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.357-363
    • /
    • 2013
  • An ultraviolet pulsed laser ablation of polyimide film coated with platinum has been used to enhance the sensitivity for the application as an electrochemical biosensor. Densely packed cones are formed on polyimide surface after UV irradiation which results in increase of surface area. In order to apply the sensitivity improvement of laser ablated polyimide film electrodes, the glucose oxidase modified biosensor was fabricated by using an encapsulation in the gel matrix through sol-gel transition of tetraethoxysliane on the surface of laser ablated polyimide film. The optimum conditions for glucose determination have been characterized with respect to the applied potential and pH. The linear range and detection limit of glucose detection were from 2.0 mM to 18.0 mM and 0.18 mM, respectively. The sensitivity of glucose biosensors fabricated with laser ablated polyimide film is about three times higher than that of plain polyimide film due to increase in surface area by laser ablation.

Investigate Electronic Property of N-doped Plasma-Polymer Thin Films for Applied Biosensors

  • Seo, Hyeon-Jin;Hwang, Gi-Hwan;Nam, Sang-Hun;Ju, Dong-U;Lee, Jin-Su;Yu, Jeong-Hun;Bu, Jin-Hyo;Yun, Sang-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.159-159
    • /
    • 2013
  • In this studying, we investigated the basic properties of N-doped plasma polymer. The N-doped plasma polymer thin films were deposited by radio frequency (13.56 MHz) plasma-enhanced chemical vapor deposition method. Various carbon-source were used as organic precursor with hydrogen gas as the precursor bubbler gas. Additionally, ammonia gas [NH3] was used as nitrogen dopant. The as-grown polymerized thin films were analyzed using cyclic voltammetry, ellipsometry, Fourier-transform infrared [FT-IR] spectroscopy, Raman spectroscopy, FE-SEM, and water contact angle measurement. Electronic property of N-doped plasma thin film is changed as flow rate of the NH3 gas.

  • PDF

Voltammetric Studies of Guanine and Its Derivatives by (TEX)$Ru(bpy)^{2+/3+}$(/TEX) Mediator on Indium Tin Oxide Electrode

  • Kim, Jin Hyeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.7
    • /
    • pp.709-711
    • /
    • 2000
  • Oxidizing metal complex mediates the electrochemical oxidation of guanine nucleotides. This catalysis results in an enhancement in cyclic voltammograms that yield the rate constant for the oxidation of guanine by the metal complex via digital simulation. The rate constant of oxidation of guanine by Ru(bpy)3(3+) is 6.4 x 10(5)M(-1)s(-l). The rate constant and the enhanced current depend on the number of phosphate groups on the sugar of nucleotidc. Also the modified guanine bases show different oxidation rate constants following the trend guanine-5'- monophosphatc (GMP) > 8-bromo-guanine-5'-monophosphate (8-Br-GMP) > xanthosine -5'-monophosphate (XMP) > inosinc-5'-monophosphate (IMP). The guanine bases derivatized differently are all distinguishable from one another, providing a basis for studying electrochemistry of DNA and RNA and developing electrochemical biosensors.

Atomistic analysis of nano/micro biosensors

  • Chen, James;Lee, James D.
    • Interaction and multiscale mechanics
    • /
    • v.3 no.2
    • /
    • pp.111-121
    • /
    • 2010
  • Dynamic analysis of nano/micro bio-sensors based on a multiscale atomistic/continuum theory is introduced. We use a generalized atomistic finite element method (GAFEM) to analyze a bio-sensor which has $3{\times}N_a{\times}N_p$ degrees of freedom, where $N_p$ is the number of representative unit cells and $N_a$ is the number of atoms per unit cell. The stiffness matrix is derived from interatomic potential between pairs of atoms. This work contains two studies: (1) the resonance analysis of nano bio-sensors with different amount of target analyte and (2) the dependence of resonance frequency on finite element mesh. We also examine the Courant-Friedrichs-Lewy (CFL) condition based on the highest resonance frequency. The CFL condition is the criterion for the time step used in the dynamic analysis by GAFEM. Our studies can be utilized to predict the performance of micro/nano bio-sensors from atomistic perspective.

Purification of Carp Serum Metallothionein Induced in Carp with Cadmium and Production of Polyclonal Antibody (카드뮴 유도 잉어 혈액으로부터의 Metallothionein 정제 및 이에 대한 다클론 항체 생산)

  • Ryu, Hyung-Seok;Kang, Ho-Joon;Kim, Seul Ki;Kim, Namsoo;Kim, Woo-Yeon
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.314-319
    • /
    • 2009
  • Metallothioneins (MTs) are low molecular weight, cysteine-rich, and heavy metal binding proteins, which could be induced with heavy metals such as Cd, Hg, Zn and Cu in liver, kidney, and in cultured cells. By using ion exchange chromatography on DE-52, MT was purified from the serum of carp induced with cadmium in order to produce antibody against MT. Polyclonal antibody produced against purified carp MT reacted well with MT in the serum of carp induced with cadmium, whereas control serum did not. This may indicate that the polyclonal antibody against the carp MT could be used for the preparation of biosensors to detect MT in fishes like carp.

Investigation of Thermal Fusion Bonding and Separation of PMMA Substrates by using Molecular Dynamics Simulations (분자동역학을 이용한 PMMA 평판의 열접합 및 분리에 대한 연구)

  • Yi, Taeil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.111-116
    • /
    • 2018
  • Thermal fusion bonding is a method to enclose open microchannels fabricated on polymer chips for use in lab-on-a-chip (LOC) devices. Polymethyl methacrylate (PMMA) is utilized in various biomedical-microelectromechanical systems (bio-MEMS) applications, such as medical diagnostic kits, biosensors, and drug delivery systems. These applications utilize PMMAs biochemical compatibility, optical transparency, and mold characteristics. In this paper, we elucidate both the conformational entanglement of PMMA molecules at the contact interfacial regime, and the qualitative nature of the thermal fusion bonding phenomena through systematic molecular dynamics simulations.

Periodic Biometric Information Collection Interface Method for Wearable Vulnerable Users

  • Lee, Taegyu
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.33-40
    • /
    • 2021
  • Recently, wearable computers equipped with various biosensors such as smart watches, smart bands, and smart patches that support daily health management of users as well as patients have been released. Users of wearable computers such as smart watches face various difficulties in performing biometric information processes such as data sensing, collection, transmission, real-time analysis, and feedback in a weak wireless and mobile biometric information service environment. In particular, the biometric information collection interface is an important basic process that determines the quality and performance of the entire biometric information service. So far, research has focused on sensing hardware and logic. This study intensively considers the interface method for effectively sensing and collecting raw biometric information. In particular, the process of collecting biometric information is designed and analyzed from the perspective of periodicity. Therefore, we propose an efficient and stable periodic collection method.

A Recombinant Microbial Biosensor for Cadmium and Lead Detection (카드뮴 및 납 검출을 위한 재조합 미생물 바이오센서)

  • Shin, Hae Ja
    • Journal of Life Science
    • /
    • v.26 no.5
    • /
    • pp.503-508
    • /
    • 2016
  • Biosensors have been used as first-step monitoring tools to detect on-site samples in a simple and cost-effective manner. Numerous recombinant microbial biosensors have been exploited for monitoring on-site toxic chemicals and biological signals. Herein, a recombinant microbial biosensor was constructed for monitoring cadmium. The cadmium responding cadC regulatory gene and it’s promoter from Staphylococcus aureus was amplified through PCR, fused with the lacZ gene, and transformed into Escherichia coli BL21 (DE3) cells. In the presence of cadmium, the biosensor cells express β-galactosidase showing red color development with chlorophenol red β-galactopyranoside (CPRG) as the enzymatic substrate. The biosensor cells showed the best β-galactosidase activity after 3 hr induction with cadmium at pH 5 and a detection range from 0.01 μM to 10 mM cadmium with a linearity from 0.01 to 0.1 μM cadmium (y = 0.98 x + 0.142, R2 = 0.98). Among the heavy metals, cadmium and lead showed good responses, tin and cobalt showed medium responses, and mercury and copper showed no responses. The biosensor cells showed good responses to several waste waters similar to buffer solution, all spiked with cadmium. The biosensor described herein could be applied for on-site cadmium monitoring in a simple and cost-effective manner without sample pretreatments.

Characteristics of cell culture on the carbon based materials (카본재질의 세포 배양 특성)

  • Nam, Hyo-geun;Oh, Hong-gi;Park, Hye-Bin;Kim, Chang-man;Jhee, Kwang-hwan;Song, Kwang-soup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.1000-1002
    • /
    • 2012
  • The material with superior biocompatibility and physical-chemical stability is required to fabricate high sensitive biosensors. Many kinds of biomaterials have been evaluated to apply for bioindustry. Recently, carbon based diamond and graphene thin films have been focal pointed as bio applications and their possibility is partially evaluated. Diamond thin film has many advantages for electrochemical and biological applications, such as wide potential window (3.0~3.5V), low background current and chemical-physical stability. And graphene film has many advantages as biomaterial, chemical-physical stability and conductivity. In this work, we have cultured human nerve cell (SH-SY5Y) on the nanocrystalline diamond, mirocrystalline diamond, graphene film and cell culture dish. We use MTT assay to evaluate the characteristics of cell culture on the substrates. As a result, nerve cell is well cultured on the carbon based diamond and graphene films as similar as cell culture dish. We expect that carbon materials have been applied for bioindustry such as biosensors.

  • PDF

Acetylcholinesterase-based Biosensor for Detection of Residual Organophosphates and Carbamates Insecticides (유기인계 및 카바메이트계 농약을 측정할 수 있는 바이오 센서의 개발)

  • Kim, Young-Mee;Kim, Jin-Young;Cho, Moon-Jae;Chang Kong-Man;Hyun, Hae-Nam;Cho, Somi K.
    • Applied Biological Chemistry
    • /
    • v.49 no.4
    • /
    • pp.315-321
    • /
    • 2006
  • Inhibitors of acetylcholinesterase(AchE), such as organophosphates and carbamates, interfere the action of AchE in nerve and may lead to a severe impairment of nerve functions or even death. Therefore, insect AchE is the biological target of predominant insecticides used in agriculture. Biosensors are sensitive and can be used as dispoisable sensors for environmental control. In recent years, the use of AchEs in biosensor technology has gained enormous attention, in particular with respect to insecticide detection. The principle of biosensors using AchE as a biological recognition element is based on the inhibition the catalytic activity by the agents to be detected. We here present a strip-type biosensor based on AchE inhibition. In this study, acetylcholinesterase and PVA-SbQ(polyvinyl alcohol functionalized with methyl pyridinium methyl sulfate) were co-immobilized on immobilone-P membranes. Immobilization of the enzymes showed a stability in 6 months without activity loss in $4^{\circ}C$ storage. Enzymes immobilized on surfaces of membrane responded to organophosphates and carbamate more sensitivitive than enzyme in solution. Organophosphates and carbamates concentrations could be detected by entrapped and surface immobilized enzymes, in 5 min. For chlorpyrifos, carbofuran, cabaryl, and methidathion, the detection limits of AChE-strip were similar to that of HPLC/GC method.