• Title/Summary/Keyword: Biomedical engineering

Search Result 7,053, Processing Time 0.038 seconds

Cell proliferation inhibition effects of epigallocatechin-3-gallate in TREK2-channel overexpressing cell line (TREK2-채널 과발현 세포주에서 에피갈로카테킨-3-갈레이트의 세포 증식 억제 효과)

  • Kim, Yangmi;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.127-135
    • /
    • 2016
  • Two-pore domain potassium (K2P) channels are the targets of physiological stimuli, such as intracellular pH, bioactive lipids, and neurotransmitters, and they set the resting membrane potential. Some types of K2P channels play a critical role in both apoptosis and tumoriogenesis. Among the K2P channels, no antagonists of the TREK2 channel have been reported. The aim of the present study was to determine if the TREK2 channel is blocked and whether cell proliferation is influenced by flavonoids in the TREK2 overexpressing HEK293 cells (HEKT2). The electrophysiological current was recorded using single channel patch clamp techniques and cell proliferation was measured using a XTT assay. The electrophysiological results showed that the TREK2 channel activity was reduced to $91.5{\pm}13.1%$ (n=5) and $82.2{\pm}13.7%$ (n=5) by flavonoids, such as epigallocatechin-3-gallate (EGCG) and quercetin in HEKT2 cells, respectively. In contrast, the EGCG analogue, epicatechin (EC), had no significant inhibitory effects on the TREK2 single channel activity. In addition, cell proliferation was reduced to $69.4{\pm}14.0%$ (n=4) by ECGG in the HEKT2 cells. From these results, EGCG and quercetin represent the first known TREK2 channel inhibitors and only EGCG reduced HEKT2 cell proliferation. This suggests that the flavonoids may work primarily by inhibiting the TREK2 channel, leading to a change in the resting membrane potential, and triggering the initiation of a change in intracellular signaling for cell proliferation. TREK2 channel may, at least in part, contribute to cell proliferation.

Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance (선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성)

  • Lee, Jeong-Woo;Hong, Se-Mie;Park, Byung-Moon;Kang, Min-Young;Kim, You-Hyun;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.183-188
    • /
    • 2008
  • Aim of this study is to investigate the feasibility of 2D ion chamber array as a substitute of the water phantom system in a periodic Linac QA. For the feasibility study, a commercial ion chamber matrix was used as a substitute of the water phantom in the measurement for a routine QA beam properties. The device used in this study was the I'm RT MatriXX (Wellhofer Dosimetrie, Germany). The MatriXX consists of a 1,020 vented ion chamber array, arranged in $24{\times}24\;cm^2$ matrix. Each ion chamber has a volume of $0.08\;cm^3$, spacing of 0.762 cm. We investigated dosimetric parameters such as dose symmetry, energy ($TPR_{20,10}$), and absolute dose for comparing with the water phantom data with a Farmer-type ionization chamber (FC65G, Wellhofer Dosimetrie, Germany). For the MatriXX measurements, we used the white polystyrene phantom (${\rho}:\;1.18\;g/cm^3$) and also considered the intrinsic layer (${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm) of MatriXX to be equivalent to water depth. In the preliminary study of geometrical QA using MatriXX, the rotation axis of collimator and half beam junction test were included and compared with film measurements. Regarding the dosimetrical QA, the MatriXX has shown good agreements within ${\pm}1%$ compared to the water phantom measurements. In the geometrical test, the data from MatriXX were comparable with those from the films. In conclusion, the MatriXX is a good substitute for water phantom system and film measurements. In addition, the results indicate that the MatriXX as a cost-effective novel QA tool to reduce time and personnel power.

  • PDF

The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique (이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구)

  • Ryeom Hun-Kyu;Lee Jongmin;Kim Yong-Sun;Lee Sang-Kwon;Suh Kyung-Jin;Bae Sung-Jin;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Purpose : To investigate the signal enhancement ratio by NOE effect on in vivo $^{31}P$ MRS in human heart muscle and liver. we also evaluated the enhancement ratios of different phosphorus metabolites, which are important in 31P MRS for each organ. Materials and Methods : Ten normal subjects (M:F = 8:2, age range = 24-32 yrs) were included for in vivo $^{31}P$ MRS measurements on a 1.5 T whole-body MRI/MRS system using $^1H-^{31}P$ dual tuned surface coil. Two-dimensional Chemical Shift Imaging (2D CSI) pulse sequence for $^{31}P$ MRS was employed in all $^{31}P$ MRS measurements. First, $^{31}P$ MRS performed without NOE effect and then the same 2D CSI data acquisitions were repeated with NOE effect. After postprocessing the MRS raw data in the time domain, the signal enhancements in percent were estimated from the major metabolites. Results : The calculated NOE enhancement for liver $^{31}P$ MRS were $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%)$ and $PME\;(31\%)$. Because there is no creatine kinase activity in liver, PCr signal is absent. For cardiac $^{31}P$ MRS, whole body coil gave better scout images and thus better localization than surface coil. In $^{31}P$cardiac multi-voxel spectra, DPG signal increased from left to right according to the amount of blood included. The calculated enhancement for cardiac $^{31}P$ MRS were : $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;(PDE)\;(51\%),\;and\;DPG\;(72\%)$. Conclusion : Our results revealed that the NOE effect was more pronounced in heart muscle than in liver with different coupling to 1H spin system and thus different heteronuclear cross-relaxation.

  • PDF

Quantitative Analysis of Brain Metabolite Spectrum Depending on the Concentration of the Contrast Media in Phantom (팬텀 내 조영제 농도에 따른 뇌 대사물질 Spectrum의 정량분석)

  • Shin, WoonJae;Gang, EunBo;Chun, SongI
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 2015
  • Quantitative analysis of MR spectrum depending on mole concentration of the contrast media in cereberal metabolite phantom was performed. PRESS pulse sequence was used to obtain MR spectrum at 3.0T MRI system (Archieva, Philips Healthcare, Best, Netherland), and the phantom contains brain metabolites such as N-Acetyl Asparatate (NAA), Choline (Cho), Creatine (Cr) and Lactate (Lac). In this study, optimization of MRS PRESS pulse sequency depending on the concentration of contrast media (0, 0.1 and $0.3mmol/{\ell}$) was evaluated for various repetition time(TR; 1500, 1700 and 2000 ms). In control (cotrast-media-free) group, NAA and Cho signals were the highest at TR 2000 ms than at 1700 and 1500 ms. Cr had the highest peak signal at TR 1500 ms. When concentration of contrast media was $0.1mmol/{\ell}$, the metabolites were increased NAA 73%, Cho 249%, Cr 37% at TR 1700 ms compared with other TR, and also signal increased at $0.3mmol/{\ell}$, In $0.5mmol/{\ell}$ of contrast agent, cerebral metabolite peaks reduced, especially when TR 1500 ms and 2000 ms they decreased below those of control group. The ratio of metabolite peaks such as NAA/Cr and Cho/Cr decreased as the concentration of the contrast agent increased from 0.1 to $0.5mmol/{\ell}$. Authors found that the optimization of PRESS sequence for 0.3T MRS was as follows: low density of contrast agent ($0.1mmol/{\ell}$ and $0.3mmol/{\ell}$) made the highest signal intensity, while high density of contrast agent reveals the least reduction of signal intensity at 1700 ms. In conclusion, authors believe that it is helpful to reduce TR for acquiring maximum signal intensity.

The Dynamic and Histologic Changes of Variously Fixed Bovine Pericardiums Specimens after Mechanical Fatigue Stimuli (다양한 고정 처리법을 이용한 소 심낭의 기계적 피로 자극 후 역학적 및 조직학적 변화)

  • Chang, Hyoung-Woo;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Park, Chun-Soo;Kim, Woong-Han;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.148-156
    • /
    • 2009
  • Background: As cardiovascular operations become more complex and sophisticated, there is an increasing need for various bioprostheses for use as components of blood vessels and heart valves. We developed a fatigue stimuli test instrument to objectively evaluate the mechanical durability of a bioprosthesis, and we tested several currently known processing methods for bovine pericardium and we then compared the results. Material and Method: Fresh bovine pericardium was collected at the butcher shop with using aseptic technique, and each piece of pericardium was fixated and/or decellularized by 16 representative methods. We measured the permeability and compliance of the processed bovine pericardium samples, and measured them again after exposure to the fatigue stimuli. All the pieces of pericardium underwent microscopic examinations before and after the fatigue stimuli. Result: A mixture of glutaraldehyde and solvent treatment showed better mechanical durability than did the single glutaraldehyde treatment. High concentration glutaraldehyde treatment showed equal or no worse results than did low concentration glutaraldehyde treatment. After SDS (sodium dodecylsulfate) decellularization, the mechanical property of the bioprosthesis became much worse ($20{\sim}190$ times) and the mechanical durability to the fatigue stimuli was also very poor. Conclusion: We obtained the basic durability data after various fixation methods with using a home-made fatigue test instrument.

Utility Estimation of the Application of Auditory-Visual-Tactile Sense Feedback in Respiratory Gated Radiation Therapy (호흡동조방사선치료 시 Real Time Monitor와 Ventilator의 유용성 평가)

  • Jo, Jung Hun;Kim, Byeong Jin;Roh, Shi Won;Lee, Hyeon Chan;Jang, Hyeong Jun;Kim, Hoi Nam;Song, Jae Hun;Kim, Young Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the possibility to optimize the gated treatment delivery time and maintenance of stable respiratory by the introduction of breath with the assistance of auditory-visual-tactile sense. Materials and Methods: The experimenter's respiration were measured by ANZAI 4D system. We obtained natural breathing signal, monitor-induced breathing signal, monitor & ventilator-induced breathing signal, and breath-hold signal using real time monitor during 10 minutes beam-on-time. In order to check the stability of respiratory signals distributed in each group were compared with means, standard deviation, variation value, beam_time of the respiratory signal. Results: The stability of each respiratory was measured in consideration of deviation change studied in each respiratory time lapse. As a result of an analysis of respiratory signal, all experimenters has showed that breathing signal used both Real time monitor and Ventilator was the most stable and shortest time. Conclusion: In this study, it was evaluated that respiratory gated radiation therapy with auditory-visual-tactual sense and without auditory-visual-tactual sense feedback. The study showed that respiratory gated radiation therapy delivery time could significantly be improved by the application of video feedback when this is combined with audio-tactual sense assistance. This delivery technique did prove its feasibility to limit the tumor motion during treatment delivery for all patients to a defined value while maintaining the accuracy and proved the applicability of the technique in a conventional clinical schedule.

  • PDF

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

Radiation Exposure Analysis of Female Nuclear Medicine Radiation Workers (여성 핵의학 방사선종사자의 피폭요인 분석)

  • Lee, Juyoung;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.209-225
    • /
    • 2016
  • In this study, radiation workers who work in nuclear medicine department were analyzed to find the cause of differences of radiation exposure from General Characteristic, Knowledge, Recognition and Conduct, especially females working on nuclear medicine radiation, in order to pave the way for positive defense against radiation exposure. The subjects were 106 radiation workers who were divided into two groups of sixty-four males and forty-two females answered questions about their General Characteristic, Knowledge, Recognition, Conduct, and radiation exposure dose which was measured by TLD (Thermo Luminescence Dosimeter). The results of the analysis revealed that as the higher score of knowledge and conduct was shown, the radiation exposure decreased in female groups, and as the higher score of conduct was shown, the radiation exposure decreased in male groups. In the correlation analysis of female groups, the non-experienced in pregnancy showed decreasing amount of radiation exposure as the score of knowledge and conduct was higher and the experienced in pregnancy showed decreasing amount of radiation exposure as the score of recognition and conduct was higher. In the regression analysis on related factors of radiation exposure dose of nuclear medicine radiation workers, the gender caused the meaningful result and the amount of radiation exposure of female groups compared to male groups. In the regression analysis on related factors of radiation exposure dose of female groups, the factor of conduct showed a meaningful result and the amount of radiation exposure of the experienced in pregnancy was lower compared to the non-experienced. The conclusion of this study revealed that radiation exposure of female groups was lower than that of male groups. Therefore, male groups need to more actively defend themselves against radiation exposure. Among the female groups, the experienced in pregnancy who have an active defense tendency showed a lower radiation exposure. Thus, those who have never been pregnant need to have a more active defensive conduct for the future possibility of pregnancy.

Report for Development of Korean Portable Cardiopulmonary Bypass II. Experimental Study of Portable Cardiopulmonary Bypass for Emergency Cardiopulmonary Resuscitation after Cardiac Arrest in Normal Dogs (한국형 이동식 심폐소생기 개발 보고 II. 응급소생술을 위한 이동식 심폐소생기의 동물 실험 연구)

  • Kim, Hyoung-Mook;Lee, In-Sung;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Lee, Hye-Won;Lee, Kyu-Back;Chang, Jun-Kuen;Kim, Chong-Won;Kim, Hark-Jei
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1147-1158
    • /
    • 1998
  • Background: Portable cardiopulmonary bypass(CPB) technique has been used increasingly as a potent and effective option for emergency cardiopulmonary resuscitation(CPR) because it can maintain more stable hemodynamics and provide better survival than conventional CPR techniques. This study was designed to develop a prototype of Korean portable CPB system and, by applying it to CPR, to discriminate whether it would be superior to standard open-chest CPR. Material and Method: By using adult mongrel dogs, open-chest CPR(OCPR group, n=4) and portable-CPB CPR(CPB group, n=4) were compared with respects to restoration of spontaneous circulation(ROSC), hemodynamics, effects on blood cells, blood gas patterns, biochemical markers, and survivals. Ventricular fibrillation-cardiac arrest(VF-CA) of arrest(VF-CA) of 4 minutes followed by basic life support(BLS) of 15 minutes was applied in either group, which was standardized by the protocol of American Heart Association. Then, advanced life support(ALS) was applied to either group under the support of internal cardiac massage or CPB. ALS was maintained until ROSC was achieved but not longer than 30 minutes regardless of the presence of ROSC. All of the measured values were expressed as means±SD percent change from baseline. Result: During the early ALS, higher mean arterial pressure was maintained in CPB group than in OCPR group(90±19 vs. 71±32 %; p<.05) and lower mean pulmonary arterial pressure was also maintained in CPB group than in OCPR group(105±24 vs. 146±6%; p<.05). ROSC was achieved in all dogs. Post-ROSC levels of hematocrit, RBC, and platelet were decreased and plasma free hemoglobin was increased significantly in CPB group compared to OCPR group(p<.05). Changes in blood gas patterns, lactate, and CK-MB levels were not different between groups. Early mortality was seen in 3 dogs in OCPR group(survival time 31±36 hours) and 2 in CPB group(228±153 hours, p=ns). The remainders in both groups showed prolonged survival. Conclusion: These findings indicate that portable CPB can be effective to maintain stable hemodynamics during cardiac arrest, to achieve ROSC and to prolong survival. Further study is needed to refine the portable CPB system and to meet clinical challenges.

  • PDF

Effects of Nasal Continuous Positive Airway Pressure Application on Sympathetic Activation : Power Spectrum Analysis of Electrocardiogram in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 시행이 교감신경계 활성도에 끼치는 영향 : 심전도 스펙트럼 분석)

  • Youn, Tak;Park, Hae-Jeong;Kim, Eui-Joong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • Objectives: Obstructive sleep apnea syndrome(OSAS) is known to be associated with the changes of autonomic nervous system (ANS). Nasal continuous positive airway pressure(nCPAP) treatment was found to correct abnormal ANS changes in OSAS but it remains to be further clarified. We aimed to assess the effects of nCPAP on ANS manifested on electrocardiogram, using spectrum analysis in the subjects with OSAS. Methods: Digital polysomnography was performed in 18 patients with OSAS(mean age $43.7{\pm}16.6$ years ; 17 males, 1 female ; mean respiratory disturbance index (RDI) $48.6{\pm}20.9$) for one baseline and another CPAP nights. From each night, 300 continuous beats of ECGs without artifact were chosen from both stage 2 sleep and REM sleep and they were used for power spectrum analysis. We compared between baseline and CPAP nights the heart rate variability including VLF(very low frequency power), LF (low frequency power), HF(high frequency power), R-R means, R-R variance, and LF/HF ratio, using Wilcoxon signed ranks test. Results: In all patients, nCPAP proved to be effective in relieving apneas and snoring. During nCPAP night compared with baseline night, decreases in VLF(p<0.05), LF(p<0.01), and R-R variance(p<0.05) were found in stage 2 sleep, and decreased LF(p<0.05) was found in REM sleep. No significant differences in each sleep stage were found in other variables between the two nights. Conclusion: Our findings suggest that OSAS increases the activity of sympathetic nervous system and nCPAP application effectively decreases the activity. And nCPAP does not appear to influence the parasympathetic nervous activity in OSAS.

  • PDF