• 제목/요약/키워드: Biomedical Ultrasound

검색결과 232건 처리시간 0.021초

발목각도 Toe 0°, Toe in 10°, Toe out 10°에 따른 스쿼트 운동이 안쪽넓은근과 가쪽넓은근의 근두께와 지면반발력에 미치는 영향 (The Effect of Squat Exercise According to Ankle Angle-Toe 0°, Toe In 10°, Toe Out 10°-on Muscle Thickness and Ground Reaction Force of Vastus Medialis Oblique and Vastus Lateralis Oblique Muscles)

  • 안수홍;이수경
    • PNF and Movement
    • /
    • 제18권1호
    • /
    • pp.65-75
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the differences in muscle thickness and ground reaction force of the vastus medialis oblique and vastus lateral oblique muscles during squats at ankle angles of toe 0°, toe in 10°, and toe out 10°. Methods: In this study, 9 male and 17 female students in their 20s participated in a randomized controlled trial and were compared according to the ankle angles of toe 0°, toe in 10°, and toe out 10°. To determine the reliability and measurement of muscle thickness according to ankle angle using ultrasound equipment and muscle thickness, the participants' ankle angles-toe 0°, toe in 10°, and toe out 10°-were measured three times at the vastus medialis oblique and vastus lateralis oblique muscles during squats. At the same time, the maximum vertical ground reaction force was measured with a force plate. A total of three measurements were taken and averaged, and two minutes of squat movements were assessed between ankle angles to prevent target action. Results: The results of this study illustrated that the reliability of the vastus medialis oblique muscles and vastus lateralis oblique muscles in ankle angle was high. The difference in muscle thickness was significantly greater in comparing the toe out 10° angle with the toe 0° angle than between toe in 10° and toe out 10° in vastus medialis oblique and vastus lateralis oblique (p < 0.05). There was no statistically significant difference between the ankle angle of toe 0° and toe in 10° (p > 0.05). The maximum vertical ground reaction force was significantly greater at toe out 10° than at the ankle angle of toe 0° and toe out 10° and between toe in 10° and toe out 10° (p < 0.05). There was no statistically significant difference in the comparison between toe 0° and toe in 10° (p > 0.05). Conclusion: Squatting at an ankle angle of toe out 10° increases the dorsi flexion; thus, the stability of the ankle and the thickness of both oblique muscles increased to perform more effective squats. In addition, as the base of support widens, it is thought that the stability of the posture increases so that squat training can be performed safely.

집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰 (Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems)

  • 김준태;김주희;주규태;김경아;류옥수;조재현;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.164-177
    • /
    • 2022
  • 의료기기 사용적합성 평가란 최종 시제품 제작 완료이전 실제 사용자를 통한 의료기기의 평가를 말한다. 국제전자의료기기 안전규격 중 하나인 IEC 62366은 유럽 및 미국 등 주요 선진국의 의료기기 인허가 획득을 위해 반드시 적용해야 하는 규격이다. 국내의 경우 식약처 고시를 통하여 2021년 1월부터 등급별로 순차적 적용을 시행하고 있다. 본 연구에서는 (주)이끌레오에서 개발 중인 집중형초음파자극시스템의 사용자 적합성 평가 중 형성평가를 인천 G 대학 병원 의료기기융합 센터를 통하여 참가자 전문의 15인을 모집하였고, 공동 시나리오 개발을 통하여 시험을 진행하였다. 작업 수행 여부 결과에서는 90.67%의 수행율을 보였으며, 수행 완료 후 참가자 설문 조사결과 문항별 결과 분석에서 '사용자 인터페이스의 용이성' 86.67%, '정보의 식별성/가독성/이해도' 문항에서 94%의 보통 이상의 응답 비율을 보였다.