• 제목/요약/키워드: Biomedical Ultrasound

검색결과 236건 처리시간 0.025초

Comparison of trunk muscle thickness according to the type of feedback during spinal stabilization exercise in standing posture

  • Lee, Hee-Ji;Lee, Su-Ha;Lee, Seong-Joo;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권3호
    • /
    • pp.184-190
    • /
    • 2020
  • Objective: Patients with low back pain can possibly have impaired core muscle function, which is the common cause of low back pain. Spinal stabilization exercises are recommended for prevention and reinforcement. This study aimed to compare the effects of different types of feedback on abdominal and lumbar multifidus (LM) muscle recruitment during spinal stabilization exercises. Design: Cross-sectional study. Methods: Fifty-seven healthy subjects (sex=male 21/female 36, age=21.28±1.60 years) were divided into three different groups: the control group (n=19), the auditory feedback (AF) group (n=19), and the visual and auditory feedback (VAF) group (n=19). The control group received no feedback, whereas the AF group only received AF during exercises and the VAF group received the AF and visual feedback through the real-time ultrasound images. The main outcome measure was the assessment of the thickness of the abdominal muscles and LM measured by a dual ultrasound. Results: When VAF was applied, the thickness of the transverse abdominis significantly increased rather than when feedback was not applied or with AF only (p<0.05). The VAF group showed significant differences in both the control group and the AF group in the post-hoc test (p<0.05), and there was no significant difference between the control group and the AF group. Conclusions: With spinal stabilization exercises, VAF should be applied in standing posture for healthy adults to further promote the production of effective contractions.

초음파 집속을 위한 트랜스듀서 어레이 집속 각도 설정 (A transducer array for focusing the ultrasound setting angle)

  • 이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.45-48
    • /
    • 2016
  • 비만을 치료하기 위해 다양한 비만 치료기가 개발되어 왔으며, 초음파는 온열 및 진동작용으로 지방이 분해가 되기 쉬운 상태로 변하게 만든 후 혈액 및 림프액의 흐름을 촉진시켜 혈액으로 지방산 배출이 될 수 있도록 한다. 이러한 초음파 비만 치료기에 트랜스듀서 어레이가 사용되는데 트랜스듀서 어레이의 집속각도와 주파수는 지방을 분해하는데 중요한 영향을 미칠 수 있다. 본 논문에서는 트랜스듀서 어레이의 주파수를 설정하기 위해 27kHz, 1MHz, 3MHz의 주파수에 직경 5mm, 10mm, 16mm의 트랜스 듀서를 적용하여 파장과 근위장을 구하여 설정온도에 가장 짧은 시간에 도달하는 주파수를 설정하고, 3개 면이 닿는 트랜스듀서의 집속 각도를 설정하였다. 결과적으로 3MHz 주파수 일 때 설정온도에 도달하는 시간이 짧았으며, 집속각도는 $40^{\circ}$가 적정하였다.

수동 휠체어 추진 속도에 따른 상지 관절 생체역학적 영향 분석 (Upper Extremity Biomechanics of Manual Wheelchair Propulsion at Different Speeds)

  • 황선홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.241-250
    • /
    • 2022
  • It is known that chronic pain and injury of upper limb joint tissue in manual wheelchair users is usually caused by muscle imbalance, and the propulsion speed is reported to increase this muscle imbalance. In this study, kinematic variables, electromyography, and ultrasonographic images of the upper limb were measured and analyzed at two different propulsion speeds to provide a quantitative basis for the risk of upper extremity joint injury. Eleven patients with spinal cord injury for the experimental group (GE) and 27 healthy adults for the control group (GC) participated in this study. Joint angles and electromyography were measured while subjects performed self-selected comfortable and fast-speed wheelchair propulsion. Ultrasound images were recorded before and after each propulsion task to measure the acromiohumeral distance (AHD). The range of motion of the shoulder (14.35 deg in GE; 20.24 deg in GC) and elbow (5.25 deg in GE; 2.57 deg in GC) joints were significantly decreased (p<0.001). Muscle activation levels of the anterior deltoid, posterior deltoid, biceps brachii, and triceps brachii increased at fast propulsion. Specifically, triceps brachii showed a significant increase in muscle activation at fast propulsion. AHD decreased at fast propulsion. Moreover, the AHD of GE was already narrowed by about 60% compared to the GC from the pre-tests. Increased load on wheelchair propulsion, such as fast propulsion, is considered to cause upper limb joint impingement and soft tissue injury due to overuse of the extensor muscles in a narrow joint space. It is expected that the results of this study can be a quantitative and objective basis for training and rehabilitation for manual wheelchair users to prevent joint pain and damage.

Protective effect and mechanism of ginsenoside Rg2 on atherosclerosis

  • Qianqian Xue;Tao Yu;Zhibin Wang;Xiuxiu Fu;Xiaoxin Li;Lu Zou;Min Li;Jae Youl Cho;Yanyan Yang
    • Journal of Ginseng Research
    • /
    • 제47권2호
    • /
    • pp.237-245
    • /
    • 2023
  • Background: Ginsenoside Rg2 (Rg2) has a variety of pharmacological activities and provides benefits during inflammation, cancer, and other diseases. However, there are no reports about the relationship between Rg2 and atherosclerosis. Methods: We used 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) to detect the cell viability of Rg2 in vascular smooth muscle cells (VSMCs) and human umbilical vein endothelial cells (HUVECs). The expression of inflammatory factors in HUVECs and the expression of phenotypic transformation-related marker in VSMCs were detected at mRNA levels. Western blot method was used to detect the expression of inflammation pathways and the expression of phenotypic transformation at the protein levels. The rat carotid balloon injury model was performed to explore the effect of Rg2 on inflammation and phenotypic transformation in vivo. Results: Rg2 decreased the expression of inflammatory factors induced by lipopolysaccharide in HUVECs-without affecting cell viability. These events depend on the blocking regulation of NF-κB and p-ERK signaling pathway. In VSMCs, Rg2 can inhibit the proliferation, migration, and phenotypic transformation of VSMCs induced by platelet derived growth factor-BB (PDGF-BB)-which may contribute to its anti-atherosclerotic role. In rats with carotid balloon injury, Rg2 can reduce intimal proliferation after injury, regulate the inflammatory pathway to reduce inflammatory response, and also suppress the phenotypic transformation of VSMCs. Conclusion: These results suggest that Rg2 can exert its anti-atherosclerotic effect at the cellular level and animal level, which provides a more sufficient basis for ginseng as a functional dietary regulator.

Initial United Kingdom experience of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography

  • Puneet Chhabra;Wei On;Bharat Paranandi;Matthew T. Huggett;Naomi Robson;Mark Wright;Ben Maher;Nadeem Tehami
    • 한국간담췌외과학회지
    • /
    • 제26권4호
    • /
    • pp.318-324
    • /
    • 2022
  • Backgrounds/Aims: Gallstone disease is a recognized complication of bariatric surgery. Subsequent management of choledocholithiasis may be challenging due to altered anatomy which may include Roux-en-Y gastric bypass (RYGB). We conducted a retrospective service evaluation study to assess the safety and efficacy of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) in patients with RYGB anatomy. Methods: All the patients who underwent EDGE for endoscopic retrograde cholangiopancreatography after RYGB at two tertiary care centers in the United Kingdom between January 2020 and October 2021 were included in the study. Clinical and demographic details were recorded for all patients. The primary outcome measures were technical and clinical success. Adverse events were recorded. Hot Axios lumen apposing metal stents measuring 20 mm in diameter and 10 mm in length were used in all the patients for creation of a gastro-gastric or gastro-jejunal fistula. Results: A total of 14 patients underwent EDGE during the study period. The majority of the patients were female (85.7%) and the mean age of patients was 65.8 ± 9.8 years. Technical success was achieved in all but one patient at the first attempt (92.8%) and clinical success was achieved in 100% of the patients. Complications arose in 3 patients with 1 patient experiencing persistent fistula and weight gain. Conclusions: In patients with RYGB anatomy, EDGE facilitated biliary access has a high rate of clinical success with an acceptable safety profile. Adverse events are uncommon and can be managed endoscopically.

이차원 곡면 어레이를 이용한 실시간 3차원 초음파 영상화 기법 (Real-Time 3-D Ultrasound Imaging Method using a 2-D Curved Array)

  • 김강식;한호산;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.351-364
    • /
    • 2002
  • 일차원 어레이 변환자를 기계적으로 움직여 3차원 영상을 얻는 기존의 3차원 초음파 영상 기법은 일차원 배열 변환기가 갖는 고도방향 해상도의 저하를 극복하기 어렵다. 한편 이차원 위상 어레이 변환자를 이용하는 실시간 3차원 영상 시스템은 많은 수의 채널 수를 가지기 때문에 고비용의 매우 큰 빔집속부를 필요로 한다. 이러한 문제점을 극복하기 위해 본 논문에서는 2차원 곡면 어레이 상에서 256 채널의 송수신 부구경을 전기적으로 움직이면서 관심영역의 입체영상을 얻을 수 있는 3차원 영상화 기법을 제안하였다. 이를 위해 본 논문에서는 상용 3차원 영상 장치에 사용되는 기계 주사식 일차원 곡면 어레이 변환자와 측방향과 고도방향으로 동일한 시야각을 갖는 이차원 곡면 어레이 변환자를 설계하였다. 또한 제안된 방법에서는 256 개의 제한된 채널 수를 이용하면서도 송수신 부구경의 크기를 증가시켜 보다 향상된 해상도의 영상을 구현하기 위해 직사각형 모양의 부구경에서 네 모서리 부분의 어레이 소자들을 적절히 제거한 형태의 부구경을 사용하였다. 특히 수신시는 고도방향이나 측방향으로한 배열 소자씩 건너뛰는 희박 어레이 기법을 적용하여 수신 부구경의 크기를 증가시켰다. 또한 수신시 희박 어레이로 인한 소자간의 간격 증가로 인해 유발되는 그레이팅 로브 상승을 억제하기 위해 송신시에는 희박 어레이를 적용하지 않고 폴드-오버 어레이 기법을 적용함으로써 송신부구경의 크기를 측방향과 고도방향으로 각각 두배만큼 증가시키는 효과를 얻었다. 제안한 방법을 통해 기존의 기계 주사식 일차원 어레이 변환자를 이용한 실시간 3차원 시스템과 비교하여 측방향으로는 거의 같고 고도방향으로는 훨씬 우수한 해상도의 영상을 획득할 수 있음을 컴퓨터 모사실험을 통해 검증하였다.

집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험 (Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges)

  • 김준태;김주희;주규태;김경아;최안렬;조재현;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.477-484
    • /
    • 2022
  • 본 연구는 집속형초음파자극시스템의 카트리지부를 시료로 사용하여 의료기기 안전성 평가 기준인 GLP(Good Laboratory Practice)에 관한 시험 중 동물실험을 통한 피부 자극 시험 및 피부 감작성시험을 진행하였다. New Zealand White Rabbit 암컷 6마리를 이용하여 IACUC 승인 후 시험을 진행하였으며, 실험기간 동안 사망한 개체 수는 없었으며, 실험동물에서 어떤 이상 증상도 관찰되지 않았다. 극성, 비극성 자극 지수는 모두 '0.0'으로 나타났다. 또한, 피부감작성 평가의 경우 IACUC 승인을 통한 기니피그 30마리를 통하여 대조군 및 실험군으로 나누어 시험검체 및 공시험액을 별도의 희석 없이 용출액 자체를 사용하여 모든 유도 및 유발단계를 적용하였다. 실험결과대조동물의 피부반응 등급은 0등급이었으며, 시험동물의 피부반응에서 1등급 이상을 나타내는 동물은 없었다. 두 시험 결과에서 피부의 이상 증상은 발견되지 않았으며, 인체에 적용하여 환자를 치료할 경우 시험에 사용된 시험재료로부터 피부의 이상 증상이 생기는 질환 등은 나타나지 않는지에 관하여 안정성을 알아 보고자 하였다.

Gender Differences in Physiological Effects of a Transient Exposure to Experimental Noise

  • ;;;;최석철
    • 대한의생명과학회지
    • /
    • 제12권4호
    • /
    • pp.375-383
    • /
    • 2006
  • The physiological responses following stress are different in individual or personality. We performed this study to clarify gender differences in influences of noise stress on physiological factors. 70 healthy subjects, which was divided man (n=30) and woman (n=40) groups, were exposed to 85 decibels of excavator noise for 15 minutes. Cardiac factors such as heart rate (HR), systolic and diastolic blood pressures (SBP and DBP, respectively), and heart rate-systolic pressure product (RPP) were determined. Transcranial Doppler ultrasound (TCD) was used to measure mean blood flow velocity (Vm), pulsatility index (PI), and resistance index (RI) in the middle, anterior and posterior cerebral arteries (MCA, ACA and PCA, respectively) before and during noise exposure. Cortisol level and hematological variables were also measured before (baseline) and immediately after the end of noise exposure. In the both groups HR, SBP, and RPP significantly decreased during noise exposure (P<0.05) but not significantly different between two groups (P>0.05). Vms of three cerebral arteries in man group decreased, whereas Vm of PCA in woman group fell during noise exposure (P<0.05). Vm, PI and RI in MCA and ACA during noise exposure were low in man group compared with woman group (P<0.05). Vm of PCA was low, whereas PI and RI of PCA were high in man group compared with woman group during noise exposure (P<0.05). Total leukocyte and red blood cell (RBC) counts slightly decreased during noise exposure but not significant (P>0.05). Levels in hematological variables decreased but not significant changed following noise exposure. Decreased rate of total leukocyte in man group was higher (P<0.05). Cortisol levels in the both groups decreased immediately after the end of noise exposure, while the decreased rate in man group was greater than that in woman group (p<0.05). These findings indicate that a transient exposure to experimental excavator noise may cause decreased changes in cardiac factors, cerebral hemodynamics and cortisol levels and the changes may be greater in men than in women.

  • PDF

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발 (Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures)

  • 장익규;허영준;전금상;최재순
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권5호
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.