• Title/Summary/Keyword: Biomechanical technique

Search Result 103, Processing Time 0.03 seconds

Fabrication and Biomechanical Characteristics of Composite Ceramic Bone Scaffolds for Bone Tissue Engineering (골 생체조직공학을 위한 복합 세라믹 골 지지체의 제조와 생체역학적 특성)

  • Kim E. S.;Chung J. H.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.5 s.106
    • /
    • pp.457-466
    • /
    • 2004
  • Novel porous composite ceramic bone scaffolds composed of biodegradable PHBV(polyhydroxybutyrate-co-hydroxyvalerate) and TA(toothapatite) have been fabricated for bone tissue engineering by a modified solvent casting and particulate leach-ing method with salt-contained heat compression technique. The results of this study suggest that the PHBV-TA composite scaffold, especially the scaffold containing 30 weight$\%$ of TA may be a good candidate far bone tissue engineering of non-load bearing area in oral and maxillofacial region.

Clinical Application of Three-Dimensional Reconstruction in Shoulder Surgeries

  • Kim, Sung-Hwan;Ha, Seung-Joo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.67-70
    • /
    • 2014
  • 3-D medical image reconstruction technique using computer simulation technology has been used in the knowledge of the anatomical features and the biomechanical characteristics with the advancement of computer hardware and software. Especially, the use of 3-D image reconstruction technique in orthopaedics demonstrates that this technique is useful to improve surgical technique as well as to help inform the knowledge of shoulder joint anatomy. The purpose of this article is to introduce the utilization of 3-D image technology in shoulder surgeries.

Lumbo-iliac Fixation Using Modified Galveston Technique in a Patient with Metastatic Sacral Tumor

  • Shin, Dong-Ah;Kim, Hyo-Jun;Shin, Dong-Gyu;Kim, Hyoung-Ihl
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.1
    • /
    • pp.61-64
    • /
    • 2007
  • Lumbo-sacral junction is a transition lone between the mobile lumbar spine and immobile pelvis. Lumbosacral junction has been considered to be the most troublesome portion of the spine to be fused because of the difference in anatomical and biomechanical factors between spine and pelvis. A metastatic sacral tumor in a 57-year-old man was resected, followed by unilateral lumbo-iliac fixation across lumbosacral junction using modified Galveston technique. Rigid fixation was successfully achieved. Detailed anatomy and surgical techniques are presented.

Sport Biomechanics Research Project at IAAF World Championships Daegu 2011 (2011 대구세계육상선수권대회 운동역학 프로젝트 수행 경과보고)

  • Bae, Young-Sang;Park, Young-Jin;Park, Jong-Jin;Lee, Joong-Sook;Chae, Woen-Sik;Park, Seung-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.503-510
    • /
    • 2011
  • The purpose of this study was to find the biomechanical research project result carried out at 2011 IAAF World championship in Daegu. This project was approved by the International Amateur Athletic Federation(IAAF) and financially supported by the Ministry of Culture, Sports and Tourism(MCST) and, Korea Association of Athletics Federations(KAAF). The total number of the project members was 20, including the members of the Scientific Committee, the Korean Society of Sport Biomechanics(KSSB) and graduate students as assistants. The objective of this project has been to analyze the performance in the track events(100 m, 110 mH) and field events(Long Jump, High Jump, Triple Jump, Pole Vault, Javelin Throw and Shot Put). This project was focused on the biomechanical research only. This kind of analysis has been carried out at major competitions for more than a decade, as it provides coaches and athletes with very useful information as an aid to training programmes and competition preparation. The biomechanical analysis of the top athletes in the world in each specialty serves as a reference for assessing technique and rationalizing the results achieved. The results will be disseminated world-wide and coaches will be in a better position to design training strategies in line with current world trends.

Biomechanical Evaluation of Cement type hip Implants as Conditions of bone Cement and Variations of Stem Design (골시멘트 특성 및 스템 형상에 따른 시멘트 타입 인공관절의 생체역학적 평가)

  • Park, H.S.;Chun, H.J.;Youn, I.C.;Lee, M.K.;Choi, K.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.212-221
    • /
    • 2008
  • The total hip replacement (THR) has been used as the most effective way to restore the function of damaged hip joint. However, various factors have caused some side effects after the THR. Unfortunately, the success of the THR have been decided only by the proficiency of surgeons so far. Hence, It is necessary to find the way to minimize the side effect caused by those factors. The purpose of this study was to suggest the definite data, which can be used to design and choose the optimal hip implant. Using finite element analysis (FEA), the biomechanical condition of bone cement was evaluated. Stress patterns were analyzed in three conditions: cement mantle, procimal femur and stem-cement contact surface. Additionally, micro-motion was analyzed in the stem-cement contact surface. The 3-D femur model was reconstructed from 2-D computerized tomography (CT) images. Raw CT images were preprocessed by image processing technique (i.e. edge detection). In this study, automated edge detection system was created by MATLAB coding for effective and rapid image processing. The 3-D femur model was reconstructed based on anatomical parameters. The stem shape was designed using that parameters. The analysis of the finite element models was performed with the variation of parameters. The biomechanical influence of each parameter was analyzed and derived optimal parameters. Moreover, the results of FE A using commercial stem model (Zimmer's V erSys) were similar to the results of stem model that was used in this study. Through the study, the improved designs and optimal factors for clinical application were suggested. We expect that the results can suggest solutions to minimize various side effects.

Science of Falling and Injury in Older Adults - Do All Falls Lead to Death?: Literature Review (노인 낙상 - 넘어짐 그리고 인체손상의 과학, 넘어지면 다 죽는가?: 문헌 고찰)

  • Choi, Woochol Joseph;Lim, Kitaek;Kim, Seung-su;Lee, Se-young
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.161-167
    • /
    • 2021
  • Understanding sciences behind fall-related hip fractures in older adults is important to develop effective interventions for prevention. The aim of this review is to provide biomechanical understanding and prevention strategies of falls and related hip fractures in older adults, in order to guide future research directions from biomechanical perspectives. While most hip fractures are due to a fall, a few of falls are injurious causing hip fractures, and most falls are non-injurious. Fall mechanics are important in determining injurious versus non-injurious falls. Many different biomechanical factors contribute to the risk of hip fracture, and effects of each individual factors are known well. However, combining effects, and correlation and causation among the factors are poorly understood. While fall prevention interventions include exercise, vision correction, vitamin D intake and environment modification, injury prevention strategies include use of hip protectors, compliant flooring and safe landing strategies, vitamin D intake and exercise. While fall risk assessments have well been established, limited efforts have been made for injury risk assessments. Better understanding is necessary on the correlation and causation among factors affecting the risk of falls and related hip fractures in older adults. Development of the hip fracture risk assessment technique is required to establish more efficient intervention models for fall-related hip fractures in older adults.

Design of the Interspinous Process Fixator Using Biomechanical Analysis for the Treament of Degenerative Lumbar Spinal Stenosis (퇴행성 요추부 척추관 협착증 치료를 위한 극돌기간 고정기구의 설계 및 생체역학적 분석)

  • Heo S.;Son K.;Lee S.J.;Moon B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1963-1966
    • /
    • 2005
  • Degenerative lumbar spinal stenosis(DLSS) is a disease inducing low back pain, leg pain, convulsion, numbness, and neurogenic claudication from compression of nerve root. Intervertebra fixation was reported to increase the degenerative of neighbor region after treatment. Recently, a new surgical technique of inserting a fixator between interspinous processes has been introduced. The purpose of this study is to design of the interspinous process fixator with flexibility to complement the trouble of using fixator in DLSS. This study evaluated the existing fixator through the mechanical test and modified fixators using the finite element analysis(FEA). Displacement, stiffness and Von-Mises stress were found to have similar values to those obtained from the mechanical test and the FEA in the biomechanical loading condition. Effects of variation in length and thickness were investigated to design an optimal fixator.

  • PDF

Comparative Analysis of Biomechanical Factors in Performing Techniques of 1/1Turn, Stretched, and Tucked on the Old Vaulting Horse and the New Vaulting Table (신.구형도마에서 1/1Turn, Stretched, Tucked 기술수행 시 운동역학적 분석)

  • Kim, Ji-Tae;Heo, Seong-Gyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.135-145
    • /
    • 2006
  • The aim of this study was to find out the differences of biomechanical factors from touching down the vaulting board to landing when techniques of 1/1Turn, stretched, and Tucked were performed on the old vaulting horse and on the new vaulting table. Three national representative men gymnasts were sampled for this study. Three dimension motion analyses by means of six Sony PD-150 video cameras with the velocity of 60 fps were used. As a result of analyzing the kinetic data from two kind of vaulting table, the following conclusions were made. 1. There was not significant differences of angular momentum between the old and the new vaulting table in all three techniques except the phase of stepping on the vaulting board and contacting the vaulting horse in the Tucked technique. IN the two phases above, the angular momentum in the new vaulting table was greater than that of the old vaulting horse. 2. There were few significant differences between the old and the new vaulting horses in the horizontal and vertical reaction force according to techniques when stepping was performed. However, it appeared tendency that the horizontal and vertical reaction force in the new vaulting table was a little greater than that of the old vaulting horse when the 1/1Turn, the Stretched and the Tucked were performed.

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.

Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced Flexibility (요추부 극돌기간 고정기구의 생체역학적 해석과 소형화 및 유연성 향상 설계)

  • Park, Jung-Hong;Heo, Soon;Lee, Sung-Jae;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1509-1517
    • /
    • 2006
  • The intervertebral fusion was reported to increase the degeneration of the neighboring region. Recently, a new technique of inserting an interspinous process fixator has been introduced to minimize the degenerative change in the lumbar spine. This study analyzed biomechanical effects of the fixator in the lumbar spine, and designed a new prototype to improve flexibility of the fixator with a reduced size. The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and finite element analysis. A finite element lumbar model of L1 to L5 was constructed. The finite element model was used to analyze intervertebral fusion, insertion of a commercial fixator and a new prototype. The range of motion of intervertebral segments and pressures at vertebral discs were calculated from FEA. The results showed that the stiffness of the prototype was reduced by 32.9% than that of the commercial one.