• 제목/요약/키워드: Biomechanical model

검색결과 232건 처리시간 0.026초

승차감 평가를 위한 수직 방향의 인체 진동 모델 개발 (Development of Vertical Biomechanical Model for Evaluating Ride Quality)

  • 조영건;박세진;윤용산
    • 소음진동
    • /
    • 제10권2호
    • /
    • pp.269-279
    • /
    • 2000
  • This paper deals with the development of biomechanical model on a seat with backrest support in the vertical direction. Four kinds of biomechanical models are discussed to depict human motion. One DOF model mainly describes z-axis motion of hip, two and three DOF models describe z-axis of hip and head, and while nine DOF model suggested in this study represents more motion than the otehr model. Three kinds of experiments were executed to validate these models. The first one was to measure the acceleration of the floor and hip surface in z-axis, the back surface in x-axis, and the head in z-axis under exciter. From this measurement, the transmissiblities of each subject were obtained. The second one was the measurement of the joint position by the device having pointer and the measurement of contact position between the human body and the seat by body pressure distribution. The third one was the measurement of the seat and back cushion by dummy. The biomechanical model parameters were obtained by matching the simulated to the experimental transmissiblities at the hip, back, and head.

  • PDF

인체 진동 모델을 이용한 시트 동적 설계 (Design of dynamic Characteristic of Seat using Estimated Biomechanical Model)

  • 조영건;윤용산;박세진
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.811-818
    • /
    • 2000
  • This paper deals with the design of a car seat for enhancing dynamic ride quality using a Biomechanical Model that was developed from the measured whole-body vibration characteristic. For evaluation of seat ride quality, the z-axis acceleration of floor as an input of biomechanical model was measured on a driving passenger car at highway and national road. Form the floor signal and the estimated biomechanical model, overall ride value evaluated by parameter study of seat stiffness and damping. The result shows that overall ride value decreases as the seat damping increases and the sear stiffness decreases. A lot of polyurethane foams were manufactured and tried to evaluate dynamic ride quality of a seat. It is found that stiffness and damping of a seat show a linear relationship, which means the stiffness and damping are not independent each other, So the optimal seat parameters within practically achievable space are determined.

  • PDF

Simulations using a whole-body biomechanical model

  • 정의승
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1990년도 춘계공동학술대회논문집; 한국과학기술원; 28 Apr. 1990
    • /
    • pp.140-150
    • /
    • 1990
  • Further developments on a dynamic biomechanical model are presented to assess musculoskeletal stresses and human responses. The model being developed is an extension of the Articulated Total Body (ATB) Model, originally developed by Calsapan Corp. for the study of human dynamics during automobile crashes, later adopted to the U.S.Air Force to simulate the reactions of aircrew personnel to such forces typically encountered in various phases of flight operations. Further refinements were introduced by Freivalds and Kaleps(1984) to account for a human neuromusculature. In this study, modelling of active neuromusculature was described and simulations of whole-body human motion were performed using the ATB Model. It indicated the potential of using a muscularized biomechanical model coupled with CAD capabilities to simulate human responses in a variety of industrial settings as well. This will serve as a basis of incorporating computer aided design methods into a muscularized biomechanical models.

  • PDF

작업부하 평가를 위한 생체역학적 측정방법 (Biomechanical Measuring Techniques for Evaluation of Workload)

  • 김정룡;박지수;조영진
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.445-453
    • /
    • 2010
  • It is necessary to quantitatively evaluate the workload of workers in order to improve the level of safety and efficiency as well as to prevent workers from musculoskeletal disorders. The purpose of this study is to introduce biomechanical methods that are largely used to quantitatively evaluate workload. The biomechanical methods use kinematics and kinetics to analyze the movement and force of biomechanical body. Motion analysis, joint angle measurement, ground reaction force, mathematical model, and electromyography (EMG) were introduced as a tool or device for biomechanical evaluation. In this study, the special feature of each method was emphasized and important tips for field measurement were summarized. The information and technique disclosed in this summary can be used to evaluate and design the workplace better by effectively control the workload of field workers.

유한요소 모델 변수의 역 추정법을 이용한 생체의 물성 규명 (Biomechanical Characterization with Inverse FE Model Parameter Estimation: Macro and Micro Applications)

  • 안범모;김영진;신현정;김정
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1202-1208
    • /
    • 2009
  • An inverse finite element (FE) model parameter estimation algorithm can be used to characterize mechanical properties of biological tissues. Using this algorithm, we can consider the influence of material nonlinearity, contact mechanics, complex boundary conditions, and geometrical constraints in the modeling. In this study, biomechanical experiments on macro and micro samples are conducted and characterized with the developed algorithm. Macro scale experiments were performed to measure the force response of porcine livers against mechanical loadings using one-dimensional indentation device. The force response of the human liver cancer cells was also measured by the atomic force microscope (AFM). The mechanical behavior of porcine livers (macro) and human liver cancer cells (micro) were characterized with the algorithm via hyperelastic and linear viscoelastic models. The developed models are suitable for computing accurate reaction force on tools and deformation of biomechanical tissues.

인공추간판 적용 시 인접 운동 분절에서의 변화 분석 (Analysis of biomechanical change of adjacent motion segment of the lumbar spine with an implanted artificial disc)

  • 김영은;윤상석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.244-247
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain and used clinically, biomechanical change with its implantation seldom studied. To evaluate the effect of artificial disc implantation on the biomechanics of lumbar spinal unit, nonlinear three-dimensional finite element model of L1-L5, S1 was developed and strain and stress of vertebral body and surrounding spinal ligaments were predicted. Intact osteoligamentous L1-L5, S1 model was created with 1-mm CT scan of a volunteer and known material property of each element were applied. This model also includes the effect of local muscles which was modeled with pre-strained spring elements. The intact model was validated with reported biomechanical data. Two models implanted with artificial discs, SB Charite or Prodisc, at L4/5 via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments, facet joint contact force with $2\sim12$ Nm flexion-extension moment.

  • PDF

인두기능의 3차원적 생체역학 모델에 관한 연구 (A study on the three-dimensional biomechanical model of the human pharyngeal function)

  • 김성민;김남현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1852-1855
    • /
    • 1997
  • A three-dimensional biomechanical modle is proposed in order to simulate human pharyngeal function based on the FEM(Finite Element Method) utilizing optimization procedure.

  • PDF

추간판 치환술이 요추분절에 미치는 생체역학적 영향 : 유한요소해석 (Biomechanical Effect of Total Disc Replacement on Lumbar Spinal Segment : A Finite Element Analysis)

  • 박원만;김기택;홍규표;김윤혁;오택열
    • 한국CDE학회논문집
    • /
    • 제13권1호
    • /
    • pp.58-66
    • /
    • 2008
  • The artificial discs have recently used to preserve the motion of the treated segment in lumbar spine surgery. However, there have been lack of biomechanical information of the artificial discs to explain current clinical controversies such as long-term results of implant wear and excessive facet contact forces. In this study, we investigated the biomechanical effects of three artificial implants on the lumbar spinal segments by finite element analysis. The finite element model of intact lumbar spine(L1-S) was developed and the three implants were inserted in L4-L5 segment of the spine model. 5 Nm of flexion and extension moments were applied on the superior plate of L1 with 400 N of compressive load. Excessive motions and high facet contact forces at the surgical level were generated in the all three implanted models. In the flexion, the peak von-Mises stresses in the semi-constrained type implant was higher than those in the un-constrained type implant which would cause wear on the polyethylene core. The results of the study would provide a biomechanical guideline for selecting optimal surgical approach or evaluating the current design of the implants, or developing a new implant.

Boundary Elements Heat Transfer Model of Temperature Distribution in Grain Storage Bins

  • T.Abe;C.E.Ofoche;Y.Hikida;Han, D.H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.922-931
    • /
    • 1993
  • Boundary element method was used to solve heat conduction problem for predicting temperature distribution in grain storage bin. Temperature of grain in storage is one of the three main abiotic factors, besides the intergranular gas composition and the grain moisture content, that determine the keeping quality and control measures used to protect grain from insects and damaging microflora. Collecting the temperature data at various points in the storage bins at different time of the day over a period of time is one way of finding the temperature distribution, this method requires a lot of time, cost and labour and less efficient. However data so collected serve useful purpose of being used to validate predicted temperature distribution using mathematical models. Mathematical models based on physical principles can potentially predict with accuracy the temperature distribution in a grain storage bin. Using the boundary element model the effect of bin wall material, ambient emperature, bin size etc. on temperature distribution can be studied. A knowledge of temperature distribution in stored grain not only helps in identifying active deterioration , but also gives an indication of potential for detection.

  • PDF