• Title/Summary/Keyword: Biomechanical analysis

Search Result 474, Processing Time 0.027 seconds

Biomechanical Analysis of Men's High Jump Medalists in IAAF World Championships, Daegu 2011 (2011 대구세계육상선수권대회 남자 높이뛰기 메달리스트들의 바이오메카닉스적 특성 분석)

  • Kim, Eui-Hwan;Bae, Young-Sang;Kim, Sung-Sup;Kwon, Moon-Seok;Wi, Ung-Ryang;KIm, Ki-Man;Lee, Jeong-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.573-584
    • /
    • 2011
  • The purpose of this study was to perform a kinematic analysis of the high jump techniques of the three men's medalists at the 2011 IAAF Championships in Daegu (August 27-September 4, 2011). In particular, a three-dimensional coordinates method was used to analyze the last three strides before touchdown, the touchdown techniques, and the movements after takeoff toward the bar. An analysis of the, data for the biomechanical characteristics of the world's best high jumpers could contribute to an improvement in the performance of a national high jumper. The first conclusion of the data analysis was that the arm movements of the gold medalist, J. Williams, had a single arm form, whereas the arm movements of the other medalists were a double arm form. Second, the difference in the knee joint angles upon touchdown and toe-off was $10^{\circ}$. Third, J. Williams achieved his maximum CM height after takeoff (1.26 m) using the maximum flexion of his knee joint. Fourth, the foot contact duration of A. Dmitrik (0.11 s) was the shortest among the medalists, and the ratio for his transformation of horizontal velocity to vertical velocity was the greatest (75.25%) among the three. Last, the maximum CM height of T. Barry was the greatest, and his foot contact duration was the longest.

Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis

  • Choi, Sung-Min;Choi, Hyunsuk;Lee, Du-Hyeong;Hong, Min-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.396-407
    • /
    • 2021
  • PURPOSE. Zirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA. MATERIALS AND METHODS. Two groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated. RESULTS. In oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material. CONCLUSION. Owing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.

Investigation of Biomechanical Factors in Track and Field Javelin Performance: A Multidimensional Analysis of Predictive Variables through Multiple Regression Analysis (육상 창던지기 기록에 미치는 운동학적 요인의 탐색: 다차원적 다중회귀를 활용한 성과 예측 변수 분석)

  • Ho-Jong Gil;Jin Joo Yang;Jong Chul Park;Young Sun Lee;Jae Myoung Park
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.175-184
    • /
    • 2023
  • Objective: The purpose of this study is to investigate the effects of human motion and javelin kinematics during the energy transfer in javelin throwing on records, and to provide evidence-based training insights for athletes and coaches to enhance records. Method: Three javelin throw athletes (age: 22.67 ± 0.58 years, height: 178.33 ± 7.37 cm, weight: 83.67 ± 1.15 kg) were recruited for this study. Each athlete attempted ten maximum record trials, and the kinematic data from each performance were analyzed to determine their influence on the records. The Theia3d Markerless system was used for motion analysis. Results: Key factors were modeled and identified at each moment. In E1, main variables were COM Y (𝛽 8.162, p<.05) and COM velocity Z (𝛽 -72.489, p<.05); in E2, COM X (𝛽 -17.604, p<.05); in E3, COM X (𝛽 -18.606, p<.05), COM velocity Y (𝛽 38.694, p<.05), and COM velocity X (𝛽 66.323, p<.05). For the javelin throw dynamics in E3, key determinants were Attitude angle and Javelin velocity in the Y-axis. Conclusion: The study reveals that controlled vertical movement, center of mass management during braking, and enhanced pelvic rotation significantly improve javelin throw performance. These kinematic strategies are critical for record enhancement in javelin throwing.

Biomechanical Analysis of the Artificial Discs (인공디스크에 대한 생체역학적 분석)

  • Kim Young-Eun;Yun Sang-Seok;Jung Sang-Ki
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.907-910
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical change with its implantation was rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Two models implanted with artificial discs, SB $Charit\acute{e}$ or Prodisc, via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments and facet joint, and the stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400 N were compared. The implanted model showed increased flexion-extension range of motion and increased force in the vertically oriented ligaments, such as ligamentum flavum, supraspinous ligament and interspinous ligament. The increase of facet contact force on extension were greater in implanted models. The incresed stress distribution on vertebral endplate for implanted cases indicated that additinal bone growth around vertebral body and this is matched well with clinical observation. With axial rotation moment, relatively less axial rotation were observed in SB $Charit\acute{e}$ model than in ProDisc model.

  • PDF

Last's biomechanical function changes analysis for Marathone shoes last development

  • Park, Seung-Beom;Seo, Guk-Ung;Kim, Yong-Jae;Yu, Seok-Ju;Lee, Jung-Suk
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.319-330
    • /
    • 2002
  • A toe spring and ball girth data, when marathone shoes research, development, and production in Korea, is a important point in athlete shoe research. It is clear from the results presented that any differences between MA3 and MA1, MA4 in 70%, 80% session in forepart last comparision. Especially the more 70%-80% session getting wide, the more 90% session getting up, Also, To development for high performance marathones shoes last, in all session, in korean style, 70%, 80%, and 90% session part function changed and consequently there is a need for normative last data that desribe foot, last shape, dimension. this leads to the conclusion that unique shoe lasts for both marathone shoes developmented last comparison are required for optimal marathone shoe comfort. The more ball girth construction will wide in forepart in last, the more comfort characteristic sill development. But relative with performance ability, it is need to research. The further study of Korea marathoner forefoot measurements(70% session ~ 90% session) among toe spring's angular difference of marathone last to north american and Korea marathone shoes last is required to develop and improve athletes performance in an effective way of study and to prevent forefoot injury.

Biomechanical Research of Soccer Footwear (축구화의 운동역학적 특성연구)

  • Jin, Young-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.31-39
    • /
    • 2005
  • The Purpose of this study was to reveal the biomechanical difference of two soccer footwear(soft ground footwear and hard ground footwear). Secondly, the purpose of this study was to clarify how each type of soccer footwear effects soccer players, which will provide scientific data to coaches and players, to further prevent injuries and to improve each players capacity. The result of comparative analysis of two soccer footwear can be summarized as below. The comparison of the very first braking force at walking found distinctive factors in the statistical data(t=3.092, p<.05). Braking impulse of two difference footwear showed distinctive factors in the statistical data(t=2.542, p<.05). In comparing GRFz max(N), the result showed a statistically significant difference in the two soccer footwear at running(t=2.784, p<.05). In the maximum braking impulse(t=2.774, p<.05) and propulsive impulse for antero-posterior direction, there was a statistically significant difference between the two soccer footwear at running. In the maximum braking force(t=3.270, p<.05) and propulsive force(t=4.956, p<.05) for antero-posterior direction, there was a statistically significant difference between the two soccer footwear at running. Significant differences were not found in moment(rotational friction) with two difference soccer footwear(moment max; t=2.231, moment min; t=1.784).

Biomechanical and postural analysis of machine repair tasks with relatively high complaints of low back pain (정비작업에 대한 인체역학적 부하 및 작업자세 평가)

  • 정민근;최경임;송영웅;이인석;이명수;임종호
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.49-60
    • /
    • 1997
  • Although the tasks are being mechanized or automated today, many tasks are still performed manually in several industrial settings. Manual materials handling and improper sorking postures are known to be a major cause of low back injuries, which are one of the major problems in the economic and public health aspects. In this study, two machine repair shops of a manufacturing company in Pohang were recommended by the company health care center to investigate the potential risk factors that may cause low back injuries. Five machine repair tasks were selected from each machine repair shop, which are accountable for relatively high complaints of low back pain. The purpose of this study is to quantitatively evaluate the hazards of the tasks, and finally to recommend the improved methods and guidelines for safe work practices. In order to accomplish this goal, the questionnaire study and ergonomic evaluations were carried out and the results were analyzed. For most of the tasks under study, workers were found to be exposed to relatively high biomechanical stresses in low back, mainly due to the heaby objects handled and the improper working postures.

  • PDF

The Effect of Low Back Pain and Pelvic Displacement on Foot Orthosis (발 보조기 착용이 요통환자의 골반 변위와 통증 변화에 미치는 영향)

  • Lee, Wan-Hee;Park, Dae-Sung
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.4
    • /
    • pp.57-67
    • /
    • 2005
  • The purpose of this study is to investigate the effect of low back pain(LBP) and pelvic displacement on foot orthosis. Before and after experiments were designed to compare the effect. 21 LBP patients who were the subjects diagnosed of applying foot orthosis for 3 weeks after, investigated about pelvic obliquity angle, displacement of ilium, lumbo-sacral angle by x-ray test which is one of pelvic displacement tests, visual analogue scale is used for LBP measurement. The result show the followings; First, Pelvic obliquity angle was significantly reduced after applying foot orthosis compared before using it(p<.05). Second, Displacement of ilium was significantly reduced after applying foot orthosis compared before using it(p<.05). Third, Lumbo-sacral angle was significantly reduced after applying foot orthosis compared before using it(p<.05). Fourth, LBP was significantly reduced after applying foot orthosis compared before using it(p<.05). This study tries to suggest new LBP treatment to reduce pelvic displacement by apply foot orthosis. In conclusion, foot orthosis reduces pelvic obliquity angle, displacement of ilium, lumbo-sacral angle and also decrease LBP. Further more, It needs of biomechanical study which can recognize relation between foot arch and pelvic displacement. This study will serve as a clinically useful data for diagnosis and treatment of LBP and biomechanical analysis of lower limb.

  • PDF

Comparative Analysis of Biomechanical Factors in Performing Techniques of 1/1Turn, Stretched, and Tucked on the Old Vaulting Horse and the New Vaulting Table (신.구형도마에서 1/1Turn, Stretched, Tucked 기술수행 시 운동역학적 분석)

  • Kim, Ji-Tae;Heo, Seong-Gyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.135-145
    • /
    • 2006
  • The aim of this study was to find out the differences of biomechanical factors from touching down the vaulting board to landing when techniques of 1/1Turn, stretched, and Tucked were performed on the old vaulting horse and on the new vaulting table. Three national representative men gymnasts were sampled for this study. Three dimension motion analyses by means of six Sony PD-150 video cameras with the velocity of 60 fps were used. As a result of analyzing the kinetic data from two kind of vaulting table, the following conclusions were made. 1. There was not significant differences of angular momentum between the old and the new vaulting table in all three techniques except the phase of stepping on the vaulting board and contacting the vaulting horse in the Tucked technique. IN the two phases above, the angular momentum in the new vaulting table was greater than that of the old vaulting horse. 2. There were few significant differences between the old and the new vaulting horses in the horizontal and vertical reaction force according to techniques when stepping was performed. However, it appeared tendency that the horizontal and vertical reaction force in the new vaulting table was a little greater than that of the old vaulting horse when the 1/1Turn, the Stretched and the Tucked were performed.

Biomechanics and Occlusion for Implant-Supported Prosthesis (임플란트 보철의 생역학과 교합)

  • Koo, Cheol-Ihn;Kwak, Jong-Ha;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.127-144
    • /
    • 2002
  • There is an increasing appreciation of the vital role that biomechanics play in the performance of oral implant. The aim of this article is to provide some basic principles that will allow a clinician to formulate a biomechanically valid treatment plan. However, at this point in the history of oral implantology, the clinician should realize that we do not know enough to provide absolute biomechanical rules that will guarantee success of all implants in all situations. To examine the biomechanical questions, one must begin with an analysis of the distribution of biting forcess to implants. Related topics, such as stress transfer to surrounding tissues and interrelationships between bone biology and mechanical loading are major subjects, deserving a separate discussion. Once rigid fixation, angulation, crestal bone level, contour, and gingival health are achieved, stress beyond physiologic limits is the primary cause of initial bone loss around implants. The restoring dentist has specific responsibilities to reduce overload to the bone-implant interface. These include proper diagnosis, leading to a treatment plan designed with adequate retention and form, and progressive loading to improve the amount and density of bone and further reduce the risk of stress beyond physiologic limits. The major remaining factor is the development of occlusal concept in harmony with the rest of the stomagnetic system.