• Title/Summary/Keyword: Biological imaging

Search Result 688, Processing Time 0.031 seconds

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

Synthesis and Preliminary Evaluation of $9-(4-[^{18}F]Fluoro-3-hydroxymethylbutyl)$ Guanine $([^{18}F]FHBG)$ in HSV1-tk Gene Transduced Hepatoma Cell (9-(4-$[^{18}F]Fluoro-3-hydroxymethylbutyl)$guanine $([^{18}F]FHBG)$의 합성과 헤르페스 단순 바이러스 티미딘 키나아제 이입 간암 세포주에서의 기초 연구)

  • Moon, Byung-Seok;Lee, Tae-Sup;Lee, Myoung-Keun;Lee, Kyo-Chul;An, Gwang-Il;Chun, Kwon-Soo;Awh, Ok-Doo;Chi, Dae-Yoon;Choi, Chang-Woon;Lim, Sang-Moo;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.218-227
    • /
    • 2006
  • Purpose: The HSV1-tk reporter gene system is the most widely used system because of its advantage that direct monitoring is possible without the introduction of a separate reporter gene in case of HSV1-tk suicide gene therapy. In this study, we investigate the usefulness of the reporter probe (substrate), $9-(4-[^{18}F]Fluoro-3-hydroxymethylbutyl)$guanine ($[^{18}F]FHBG$) for non-invasive reporter gene imaging using PET in HSV1-tk expressing hepatoma model. Materials and Methods: Radiolabeled FHBG was prepared in 8 steps from a commercially available triester. The labeling reaction was carried out by NCA nucleophilic substitution with $K[^{18}F]/K2.2.2.$ in acetonitrile using N2-monomethoxytrityl-9-14-(tosyl)-3-monomethoxytritylmethylbutyl]guanine as a precursor, followed by deprotection with 1 N HCl. Preliminary biological properties of the probe were evaluated with MCA cells and MCA-tk cells transduced with HSV1-tk reporter gene. In vitro uptake and release-out studies of $[^{18}F]FHBG$ were performed, and was analyzed correlation between $[^{18}F]FHBG$ uptake ratio according to increasing numeric count of MCA-tk cells and degree of gene expression. MicroPET scan image was obtained with MCA and MCA-tk tumor bearing Balb/c-nude mouse model. Results: $[^{18}F]FHBG$ was purified by reverse phase semi-HPLC system and collected at around 16-18 min. Radiothemical yield was about 20-25%) (corrected for decay), radiochemical purity was >95% and specific activity was around >55.5 $GBq/{\mu}\;mol$. Specific accumulation of $[^{18}F]FHBG$ was observed in HSV1-tk gene transduced MCA-tk cells but not in MCA cells, and consecutive 1 hour release-out results showed more than 86% of uptaked $[^{18}F]FHBG$ was retained inside of cells. The uptake of $[^{18}F]FHBG$ was showed a highly significant linear correlation ($R^2=0.995$) with increasing percentage of MCA-tk numeric cell count. In microPET scan images, remarkable difference of accumulation was observed for the two type of tumors. Conclusion: $[^{18}F]FHBG$ appears to be a useful as non-invasive PET imaging substrate in HSV1-tk expressing hepatoma model.

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Morphometric Analysis of Distances between Sacral Hiatus and Conus Medullaris Using Magnetic Resonance Image in Korean Adult (자기공명영상을 이용한 한국 성인의 엉치뼈틈새와 척수원뿔 사이 거리 연구)

  • Park, Tai Soo;Hwang, Byeong-Wook;Park, Sang-Joon;Baek, Sun-Yong;Yoon, Sik
    • Anatomy & Biological Anthropology
    • /
    • v.29 no.4
    • /
    • pp.145-154
    • /
    • 2016
  • The purpose of this study was to provide basic biometric data on Korean adults through magnetic resonance imaging (MRI)-based measurements of the distances between the apex of sacral hiatus (SH) and the termination of dural sac (DS), and between SH and conus medullaris (CM) because they are critical to the performance of epidural neuroplasty. A total of 200 patients(88 males and 112 females) with back pain, who had no spine fracture, significant spinal deformity, and spondyloisthesis were selected for this study. The subjects were of mean age 54.3 (20~84) years and mean height 161.3 cm (135~187). T2-weighted MRI images were used for correlation analysis to evaluate the relationships between the distances, and variables such as sex and height. In all patients, the mean distance between SH and DS was $62.8{\pm}9.4mm$ and the mean distance between SH and CM was $232.2{\pm}21.8mm$. The minimum distance and the maximum distance between SH and DS were 34.8 mm and 93.9 mm respectively, and the minimum distance and the maximum distance between SH and CM were 155.0 mm and 284.0 mm respectively. In female patients, both the distances between the SH and DS, and between SH and CM were shorter when compared to those of the male patients(p<0.05). Both the distances between SH and DS and between SH and CM showed a significant correlation with height(p<0.01). The results of this study will provide a useful biometric data on the distances between SH and DS and between SH and CM in Korean in ensuring clinical safety and in the development of more effective catheterization techniques for epidural neuroplasty in Korean.

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Physical properties of a new resin-based root canal sealer in comparison with AH Plus Jet (새로운 레진계 근관실러와 AH Plus Jet의 물성 비교)

  • Thu, Myint;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.80-87
    • /
    • 2017
  • Purpose: The aim of this study was to assess the physical properties of a novel resin-based endodontic sealer, Any-Seal, in comparison with AH Plus Jet. Materials and Methods: Flow, radiopacity and compressive strength were examined according to ISO 6876/2001. For flow test, 0.05 mL of sealer was placed between glass plate and 100 g weight were applied. Ten minutes after mixing the sealers, the load was removed and the diameters of the compressed sealer discs were measured. For radiopacity, 10 mm diameter and 1 mm thickness sample were fabricated and took radiograph with an aluminum step-wedge and analyzed using imaging program. For compressive strength test, $4mm{\times}6mm$ cylindrical specimen was fabricated and tested after 24 hours and 1 week using Universal testing machine. Results: Both tested sealers were consistent with ISO 6876/2001 in the flow and radiopacity test. The flow values of both sealers were not significantly different (P > 0.05). AH Plus Jet had significantly higher radiopacity (P < 0.05). AH Plus Jet showed higher compressive strength at both time intervals (P < 0.05). Conclusion: Any-Seal showed low compressive strength until after 1 week, so its physical and biological aspect should be evaluated more before clinical use.

Robust Image Fusion Using Stationary Wavelet Transform (정상 웨이블렛 변환을 이용한 로버스트 영상 융합)

  • Kim, Hee-Hoon;Kang, Seung-Hyo;Park, Jea-Hyun;Ha, Hyun-Ho;Lim, Jin-Soo;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.6
    • /
    • pp.1181-1196
    • /
    • 2011
  • Image fusion is the process of combining information from two or more source images of a scene into a single composite image with application to many fields, such as remote sensing, computer vision, robotics, medical imaging and defense. The most common wavelet-based fusion is discrete wavelet transform fusion in which the high frequency sub-bands and low frequency sub-bands are combined on activity measures of local windows such standard deviation and mean, respectively. However, discrete wavelet transform is not translation-invariant and it often yields block artifacts in a fused image. In this paper, we propose a robust image fusion based on the stationary wavelet transform to overcome the drawback of discrete wavelet transform. We use the activity measure of interquartile range as the robust estimator of variance in high frequency sub-bands and combine the low frequency sub-band based on the interquartile range information present in the high frequency sub-bands. We evaluate our proposed method quantitatively and qualitatively for image fusion, and compare it to some existing fusion methods. Experimental results indicate that the proposed method is more effective and can provide satisfactory fusion results.

THE APPEARENCE OF PROINFLAMMATORY CYTOKINES IN TEMPOROMANDIBULAR JOINT DISORDERS AFTER ARTHROCENTESIS AND LAVAGE (측두하악장애환자에서 악관절 세척술후 관절활액의 전구염증성 Cytokines의 발현)

  • Kim, Cheol-Hun;Hwang, Hie-Sung;Shin, Sang-Hoon;Chung, In-Kyo;Hwang, Tae-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.5
    • /
    • pp.370-378
    • /
    • 2005
  • The purpose of this study is that evaluate the distribution and biological roles of TNF-a, interleukin-1${\beta}$(IL-1${\beta}$), interleukin-6(IL-6) and tissue inhibitors of metalloproteinase-1(TIMP-1) in the synovial fliud of patients with non-inflammatory chronic temporomandibular joint(TMJ) disorders in relation to pain during joint movements and magnetic resonance imaging(MRI) findings. TMJ synovial fluids aspirates were obtained from 36 patients (36 joints) with chronic TMJ disorders and from 8 controls(8 joints). Patients were divided to four groups. The control group was from healthy volunteers(8 joints), group I(18 joints) was patients with anterior disc displacement with reduction, group II(5 joints) was patients with disc displacement without reduction and group III (5 joints) was osteoarthritis. The TNF-${\alpha}$, IL-1${\beta}$ and IL-6 levels in the aspirates were determined by using an enzyme-linked immunosorbent assay and the TIMP-1 level was measured by an enzyme immunoassay. Following examinations for pain during joint movements and MRI observations, these cytokines' level and frequencies of detection were compared. The level of IL-1${\beta}$was not significant different in all groups. but the level of TNF-${\alpha}$, IL-6 and TIMP-1 were significant different among groups. The level of IL-6 and TIMP-1 were correlated to pain during movement(p<0.01) and the level of TNF-a(p<0.05). Also, the level of IL-6 was correlated to the level of TIMP-1(p<0.01). Especially, The level of the TIMP-1 level was significantly correlated to the pain during movement and showed very high levle of Pearson's correlation coefficient (r=0.833)(p<0.001). The results indicated that the TNF-${\alpha}$, IL-6 and TIMP-1 levels in the TMJ aspirates of patients with chronic TMJ disorders have been raised. Especially, IL-6 and TIMP-1 were very high levels in the patients who were degraded in the TMJ. Also, TNF-${\alpha}$, IL-6 and TIMP-1 showed the significant correlation in the chronic temporomandibular joint disorders. Therefore I suggest that these cytokines were also correlated to the pain during movement in the chronic temporomandibular joint disorders.