• Title/Summary/Keyword: Biological dosimetry

Search Result 59, Processing Time 0.028 seconds

Interstitial Photodynamic Therapy (PDT) Set-up for Treating Solid Tumor Using Laser Diode (레이저 다이오드를 이용한 고형암 치료를 위한 간질성 광역학 치료법 개발)

  • Kim Jong-Ki;Kim Ki-Hong
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.104-109
    • /
    • 2005
  • Photodynamic therapy (PDT) is one of the expectable current cure operation methods. Tumor tissue is treated by abundant oxygen in a body and generated singlet or free radical from exterior laser diode and photosensitizer. Current problem of PDT is the low penetration power of the light beam in a deep seated large tumor and solid tumor thus results in low treatment outcome. In the study, we tried to develop interstitial photodynamics therapy treatment to solve this problem. As the accurate determination of light dosimetry in biological tissue is one of the most important factors affecting the effectiveness of PDT, parameters used in this study are the optical property of biological tissue. Since biological tissues have large scattering coefficient to visible light the penetration depth of a biological tissue in visible light region is only $15\~20$ mm. We showed that it is possible to measure fluence rate and penetration depth within the biological tissues by Monte Carlo simulation very well. Based on the MC simulation study, the effectiveness of interstitial photodynamic therapy on tumor control in solid tumor was proved through in vivo animal experiment.

  • PDF

Radiation exposure dose in human blood lymphocytes as assessed by the CBMN assay

  • Ryu, Tae Ho;Kim, Jin-Hong;Kim, Jin Kyu
    • Journal of Ecology and Environment
    • /
    • v.37 no.4
    • /
    • pp.195-200
    • /
    • 2014
  • The chances of accidental exposure are augmented as the application of ionizing radiation increases in various fields. Such accidental exposures may occur at nuclear power plants, laboratories, and hospitals. Cytogenetic assays have been used for estimating radiation dose in the situation of the accidents. The micronucleus assay has several advantages over the other cytogenetic methods as it is simple and fast. The present study aimed at investigation of the micronuclei frequencies in cytokinesis-block cells in human blood lymphocytes after ${\gamma}$-irradiation and at establishment of a standard dose response relationship. The samples of peripheral blood were obtained from 6 different donors aged between 24 and 30 years old. The bloods were irradiated in vitro with 0-5 Gy. A linear quadratic dose-response equation was obtained by scoring the micronuclei in binucleated cells; $y=27.87x^2+46.13x+2.08$ ($r^2=0.99$). Irradiation caused a significant decrease in the nuclear division index. Necrotic and apoptotic cells increased in number after irradiation in a dose-dependent manner. In conclusion, the conventional cytokinesis-block micronucleus assay has proven to be the great technique in biological dosimetry. Dose-response calibration curve derived from CMBN assay could be used to estimate the exposure dose during a radiological emergency.

A Study on the Measurements of Optical Parameters in Photosensitizer by Light Scattering (농도가 진한 매질에서 광증감제에 의한 광학적 파라미터측정에 관한 연구)

  • Kim, Ki-Jun;Lee, Jou-Joub
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.102-108
    • /
    • 2011
  • The study of wave propagation and scattering in biological media has become increasingly important in recent years. The propagation of light within tissues is an important problem that confronts the dosimetry of therapeutic laser delivery and the development of diagnostic spectroscopy. In the clinical application of photodynamic therapy(PDT) and in photobiology, the photon deposition within a tissue determines the spatial distribution of photochemical reactions. Scattered light is measured as a function of the distance (r) between the axis of the incident beam and the detection spot. Consequently, knowledge of the photosensitizer(Chlorophyll-a) function that characterizes a phantom is measured. To obtain the results of scattering coefficients(${\mu}s$) of a turbid material from diffusion described by experimental approach. It was measured the energy fluency of photon radiation at the position of penetration depth. From fluorescence experimental method obtained the analytical expression for the scattered light as the values of $(I/I_o)_{wavelength}$ vs the distance between the center of the incident beam and optical fiber in terms of the condition of "in situ spectroscopy(optically thick)" and real time by fluorometric measurements. The result was compromised with transport of intensities though a random distribution of scatters.

Thermally Stimulated Currents in Gamma Irradiated Polymer (감마선에 조사된 중합체의 열자극 전류)

  • Chu, Sung-Sil
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.49-55
    • /
    • 1982
  • Thermally stimulated currents of polymers have some properties as radiation dosimetry, especially polymer could be made as a good dosimeter in biological fields because of tissue equivalent material. We experimented the radiation response of polymers and attempted to apply it in clinical use. Polymers have the properties of thermoluminescence and thermally stimulated currents which are due to several kinds of charged particles such as dipoles, electronic trapped charges and mobile ions. Several peaks are datected in the thermally stimulated currents in polyethylene under vias field V, by heating from room temperature to $100^{\circ}C$ shortly after irradiation. As V increases, both the peak temperature $T_m$ and the activation energy H decreases, while the peak current $I_m$ increases. We plotted the $T_m-V\;and\;I_m-V$ curves and calculated the electron trap depth with the recombination operative TSC theory and compared the peak TSC with radiation doses.

  • PDF

Use of Frequencies of Micronuclei as Biological Dosimetry in Korean Native Cattle and Goat Lymphocytes after Irradiation in vitro (한우 및 한국재래산양 유래 말초혈액 림프구의 미소핵을 이용한 방사선 피폭의 생물학적 선량측정)

  • 류시윤;김민주;김호준;조성환;김태환;정규식;이해준;김성호
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.290-294
    • /
    • 2002
  • The frequencies of gamma-ray-induced micronuclei (MN) in cytokinesis-blocked (CB) lymphocytes at several doses were measured in three donors of Korean native cattle and Korean native goat. Measurements performed after irradiation showed a dose-related increases in MN frequency in each of the donors studied. When analysed by linear-quadratic model the line of best fit was cattle : y : 0.1016D +$0.0118D^2$+0.0147, goat : y = 0.1353D +$0.0043D^2$+0.0087 (y : number of MN/CB cells and D = irradiation dose in Gy). The relative sensitivity of goat lymphocytes compared with cattle lymphocytes was estimated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 Gy to 4 Gy. In the case of MN frequency with 0.05, 0.1, 0.2, 0.4 and 0.8, the relative sensitivities of goat lymphocytes were 1.106. 1.166. 1.140, 1.069 and 0.976 respectively. Our in vitro radiobiological study confirmed that the cytogenetic response obtained in blood from cattle and goat can be utilized for application in environmental studies.

Reference Dosimetry and Calibration of Glass Dosimeters for Cs-137 Gamma-rays (연구용 세슘-137 조사기에 대한 흡수선량 측정과 유리선량계 교정에 관한 연구)

  • Moon, Young Min;Rhee, Dong Joo;Kim, Jung Ki;Kang, Yeong-Rok;Lee, Man Woo;Lim, Heuijin;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.140-144
    • /
    • 2013
  • In this research, the glass dosimeter was calibrated to measure the standard absorbed dose of the Cs-137 irradiator and absorbed dose in a biological sample. Absorbed dose in water for Cs-137 gamma ray was determined by the IAEA TRS-277 protocol. The PTW-TM30013 ion chamber and the PTW-TM41023 water phantom were utilized for measuring absorbed dose and the value was compared with the reading from DoseAce GD-302M glass dosimeter from Asahi Techno Glass Corporation for its calibration. The uncertainty of measurement ($1{\sigma}$) of the calibrated glass dosimeter was 2.7% and this result would be applied to improve the accuracy in measurement of absorbed dose in a biological sample.

Development of A Electromagnetic Exposure System for In Vitro Experiments at PCS Band (PCS 대역 세포실험용 전자파 노출 장치 개발)

  • Part Min-Young;Ko Chae-Ok;Sung Mi-Jin;Kim Jeong-Lan;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.335-340
    • /
    • 2006
  • In this paper, a rectangular-cavity-type exposure system for in vitro experiments has been developed fur the biological effect studies of radio frequency fields from handhold wireless telephones. It ia fed with a ${\lambda}_g/8$ monopole antennas at the ${\lambda}_g/4$ position of the top plate in order to excite fundamental $TE_{102}$ mode and it allows the uniform exposure of one 8.5 cm(inner diameter) petri dish. SARs inside the exposed medium have been characterized by numerical simulations, using the FDTD method and by experimental dosimetry with fiberoptic temperature probes (model 790, Luxtron Corp.).

Observation on The Frequency of Chromosomal Aberration and Changes in Number of Peripheral Lymphocytes in Radioactive Iodine Treatment (방사성옥소 투여에 따른 말초혈액 림프구 수의 변화 및 염색체이상 빈도의 관찰)

  • Koo, Chun-Hee;Shin, Min-Ho;Park, Young-Ju;Lee, Jung-Yim;Park, Tae-Yong;Lee, Jae-Yong;Kim, Chong-Soon;Han, Seung-Soo;Kim, Kwang-Hoe;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.343-349
    • /
    • 1995
  • Background : For biological dosimetry of radiation exposure, both observing hematologic change and calculating Ydr by chromosomal analysis as biological indicators are widely used. However, due to the lack of studies on biological dosimetry of radiation dose absorbed in the body such as in the cases of radioactive iodine therapy, the maximal and safe dose is not well known, nor is the extent to which the body can safely endure radiation exposure. Purpose : To investegate the practical applicability of hematologic changes and Ydr as an indicator for estimating radiation exposure, to patients with thyroid diseases after doses of radioactive iodine. Material and Methods : 5 patients with hyperthyroidism and 35 patients who have had thyroid cancer operation were under treatment with radioactive iodine, changes in number of lymphocytes were tracked and Ydr was calculated for more than 2 months by chromosomal analysis in peripheral lymphocytes. Results ; 1) The number of lymphocytes began to decrease 2 weeks after doses of radioactive iodine, and reached the nadir after 6 and 8 weeks, then gradually recovered. 2) The nadir count of lymphocytes was reversely correlated with the administered dosage of radioactive iodine. 3) Ydr was generally stable between 2 and 8 weeks. 4) The maximal value of Ydr was correlated with the administered dosage of radioactive iodine. 5) Ydr value at the 2nd week increased with augmented dosage of radioactive iodine. 6) Ydr value at the 2nd week was correlated with fall of lymphocyte count. Conclusion : Patients must be closely observed, because temporary bone marrow suppression and slight chromosomal aberration can be produced by even generally used dosages of radioactive iodine for diagnosis and therapy. Maximal percent fall of lymphocyte count, Ydr at the 2 week interval and maximal Ydr can be used as the biological predictor of administered dosage of radioactive iodine.

  • PDF

Absorbed Dose Determination for a Biological Sample Irradiated by Gamma Rays from a Cs-137 Source (Cs-137 감마선에 대한 생물학 연구용 시료의 흡수선량 결정에 관한 연구)

  • Jeong, Dong-Hyeok;Kim, Jeung-Kee;Yang, Kwang-Mo;Ju, Min-Su;Kim, Min-Young;Lee, Chang-Yeol;Kim, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.124-130
    • /
    • 2011
  • In this study the dosimetric evaluation for a biological sample irradiated by gamma rays from Cs-137 irradiator (Gamma Irradiator, Chiyoda Technol Co., Japan) was performed for radiobiological experiment. A spherical water with a diameter of 3 cm was assumed as a biological sample. The absorbed dose were determined by the air kerma based dosimetric calculation system. The theoretical and Monte Carlo calculations (MCNPX) were performed and compared to evaluate measured air kerma and determined absorbed dose respectively. As a result of comparison with theoretical calculation, the measured air kerma was in good agreement within 3.1% at the distance of 100 and 200 cm from the source. In comparison with Monte Carlo results the determined absorbed dose along the central axis was in good agreement within 1.9% and 3.7% at 100 cm and 200 cm respectively. Although the preliminary results were obtained in this study these results were used as a basis of dosimetric evaluation for radiobiological experiment. Extended study will be performed to evaluate the dose in various conditions of biological samples.

A Correlation Study between the Environmental, Personal Exposures and Biomarkers for Volatile Organic Compounds (대기 중 휘발성유기오염물질의 환경, 개인 및 인체 노출의 상관성 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.197-205
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health problem throughout the world. Many important questions remain to be addressed in assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in the analytical determination of VOCs. Personal exposure measurements are needed to evaluate the relationship between microenvironmental concentrations and actual exposures. It is also important to investigate exposure frequency, duration, and intensity, as well as personal exposure characteristics. In addition to air monitoring, biological monitoring may contribute significantly to risk assessment by allowing estimation of absorbed doses, rather than just the external exposure concentrations, which are evaluated by environmental and personal monitoring. This study was conducted to establish the analytic procedure of VOCs in air, blood, urine and exhaled breath and to evaluate the relationships among these environmental media. The subjects of this study were selected because they are occupationally exposed to high levels of VOCs. Environmental, personal, blood, urine and exhalation samples were collected. Purge & trap, thermal desorber, gas chromatography and mass selective detector were used to analyze the collected samples. Analytical procedures were validated with the“break through test”, 'quot;recovery test for storage and transportation”,“method detection limit test”and“inter-laboratory QA/QC study”. Assessment of halogenated compounds indicted that they were significantly correlated to each other (p value < 0.01). In a similar manner, aromatic compounds were also correlated, except in urine sample. Linear regression was used to evaluate the relationships between personal exposures and environmental concentrations. These relationships for aromatic and halogenated are as follows: Halogen $s_{personal}$ = 3.875+0.068Halogen $s_{environmet}$, ($R^2$= .930) Aromatic $s_{personal}$ = 34217.757-31.266Aromatic $s_{environmet}$, ($R^2$= .821) Multiple regression was used to evaluate the relationship between exposures and various exposure deter-minants including, gender, duration of employment, and smoking history. The results of the regression model-ins for halogens in blood and aromatics in urine are as follows: Halogen $s_{blood}$ = 8.181+0.246Halogen $s_{personal}$+3.975Gender ($R^2$= .925), Aromatic $s_{urine}$ = 249.565+0.135Aromatic $s_{personal}$ -5.651 D.S ($R^2$ = .735), In conclusion, we have established analytic procedures for VOC measurement in biological and environmental samples and have presented data demonstrating relationships between VOCs levels in biological media and environmental samples. Abbreviation GC/MS, Gas Chromatography/Mass Spectrometer; VOCs, Volatile Organic Compounds; OVM, Organic Vapor Monitor; TO, Toxic Organicsapor Monitor; TO, Toxic Organics.