• 제목/요약/키워드: Biokinetic Data

검색결과 7건 처리시간 0.021초

A Review of Organ Dose Calculation Methods and Tools for Patients Undergoing Diagnostic Nuclear Medicine Procedures

  • Choonsik Lee
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.1-18
    • /
    • 2024
  • Exponential growth has been observed in nuclear medicine procedures worldwide in the past decades. The considerable increase is attributed to the advance of positron emission tomography and single photon emission computed tomography, as well as the introduction of new radiopharmaceuticals. Although nuclear medicine procedures provide undisputable diagnostic and therapeutic benefits to patients, the substantial increase in radiation exposure to nuclear medicine patients raises concerns about potential adverse health effects and calls for the urgent need to monitor exposure levels. In the current article, model-based internal dosimetry methods were reviewed, focusing on Medical Internal Radiation Dose (MIRD) formalism, biokinetic data, human anatomy models (stylized, voxel, and hybrid computational human phantoms), and energy spectrum data of radionuclides. Key results from many articles on nuclear medicine dosimetry and comparisons of dosimetry quantities based on different types of human anatomy models were summarized. Key characteristics of seven model-based dose calculation tools were tabulated and discussed, including dose quantities, computational human phantoms used for dose calculations, decay data for radionuclides, biokinetic data, and user interface. Lastly, future research needs in nuclear medicine dosimetry were discussed. Model-based internal dosimetry methods were reviewed focusing on MIRD formalism, biokinetic data, human anatomy models, and energy spectrum data of radionuclides. Future research should focus on updating biokinetic data, revising energy transfer quantities for alimentary and gastrointestinal tracts, accounting for body size in nuclear medicine dosimetry, and recalculating dose coefficients based on the latest biokinetic and energy transfer data.

Application of the new ICRP iodine biokinetic model for internal dosimetry in case of thyroid blocking

  • Kwon, Tae-Eun;Chung, Yoonsun;Ha, Wi-Ho;Jin, Young Woo
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1826-1833
    • /
    • 2020
  • Administration of stable iodine has been considered a best measure to protect the thyroid from internal irradiation by radioiodine intake, and its efficacy on thyroid protection has been quantitatively evaluated in several simulation studies on the basis of simple iodine biokinetic models (i.e., three-compartment model). However, the new iodine biokinetic model adopted by the International Commission on Radiological Protection interprets and expresses the thyroid blocking phenomenon differently. Therefore, in this study, the new model was analyzed in terms of thyroid blocking and implemented to reassess the protective effects and to produce dosimetric data. The biokinetic model calculation was performed using computation modules developed by authors, and the results were compared with those of experimental data and prior simulation studies. The new model predicted protective effects that were generally consistent with those of experimental data, except for those in the range of stable iodine administration -72 h before radioiodine exposure. Additionally, the dosimetric data calculated in this study demonstrates a critical limitation of the three-compartment model in predicting bioassay functions, and indicated that dose assessment 1 d after exposure would result in a similar dose estimate irrespective of the administration time of stable iodine.

Age-Specific Thyroid Internal Dose Estimation for Koreans

  • Kwon, Tae-Eun;Yoon, Seokwon;Ha, Wi-Ho;Chung, Yoonsun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.170-177
    • /
    • 2021
  • Background: The International Commission on Radiological Protection is preparing to provide reference dose coefficients for environmental radioiodine intake based on newly developed age-specific biokinetic models. However, the biokinetics of iodine has been reported to be strongly dependent on the dietary intake of stable iodine; for example, the thyroidal uptake of iodine may be substantially lower in iodine-rich regions than in iodine-deficient regions. Therefore, this study attempted to establish a system of age-specific thyroid dose estimation for South Koreans, whose daily iodine intakes are significantly higher than that of the world population. Materials and Methods: Korean age-specific biokinetic parameters and thyroid masses were derived based on the previously developed Korean adult model and the Korean anatomical reference data for adults, respectively. This study complied with the principles used in the development of age-specific biokinetic models for world population and used the ratios of baseline values for each age group relative to the value for adults to derive age-specific values. Results and Discussion: Biokinetic model predictions based on the Korean age-specific parameters showed significant differences in iodine behaviors in the body compared to those predicted using the model for the world population. In particular, the Korean age-specific thyroid dose coefficients for 129I and 131I were considerably lower than those calculated for the world population (25%-76% of the values for the world population). Conclusion: These differences stress the need for Korean-specific internal dose assessments for infants and children, which can be achieved by using the data calculated in this study.

Biokinetics of Protein Degrading Clostridium cadaveris and Clostridium sporogenes in Batch and Continuous Mode of Operations

  • Koo, Taewoan;Jannat, Md Abu Hanifa;Hwang, Seokhwan
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권4호
    • /
    • pp.533-539
    • /
    • 2020
  • A quantitative real-time polymerase chain reaction (QPCR) was applied to estimate biokinetic coefficients of Clostridium cadaveris and Clostridium sporogenes, which utilize protein as carbon source. Experimental data on changes in peptone concentration and 16S rRNA gene copy numbers of C. cadaveris and C. sporogenes were fitted to model. The fourth-order Runge-Kutta approximation with non-linear least squares analysis was employed to solve the ordinary differential equations to estimate biokinetic coefficients. The maximum specific growth rate (μmax), half-saturation concentration (Ks), growth yield (Y), and decay coefficient (Kd) of C. cadaveris and C.sporogenes were 0.73 ± 0.05 and 1.35 ± 0.32 h-1, 6.07 ± 1.52 and 5.67 ± 1.53 g/l, 2.25 ± 0.75 × 1010 and 7.92 ± 3.71 × 109 copies/g, 0.002 ± 0.003 and 0.002 ± 0.001 h-1, respectively. The theoretical specific growth rate of C. sporogenes always exceeded that of C. cadaveris at peptone concentration higher than 3.62 g/l. When the influent peptone concentration was 5.0 g/l, the concentration of C.cadaveris gradually decreased to the steady value of 2.9 × 1010 copies/ml at 4 h Hydraulic retention time (HRT), which indicates a 67.1% reduction of the initial population, but the wash out occurred at HRTs of 1.9 and 3.2 h. The 16S rRNA gene copy numbers of C. sporogenes gradually decreased to steady values ranging from 1.1 × 1010 to 2.9 × 1010 copies/ml. C. sporogenes species was predicted to wash out at an HRT of 1.6 h.

BIDAS프로그램 : 방사성 핵종의 섭취량과 선량 평가용 생물학적분석 자료 해석 소프트웨어 프로그램 (The BIDAS Program : Bioassay Data Analysis Software for Evaluating Radionuclide Intake and Dose)

  • Tae-Yong Lee;Jong-Kyung Kim;Jong-Il Lee;Si-Young Chang
    • 방사성폐기물학회지
    • /
    • 제2권2호
    • /
    • pp.113-124
    • /
    • 2004
  • 본 연구에서는 인체 내에서 방사성핵종의 거동에 관하여 국제방사선방호위원회에서 권고한 최근 호흡기 모델, 소화기 모델 및 생체동역학 모델을 사용하여 생물학적분석 자료로부터 섭취량과 예탁유효선량을 평가하기 위한 BIDAS 프로그램을 개발하였다. 프로그램은 생물학적분석 자료를 관리하는 데이터베이스 모듈, 각 방사성 핵종에 대한 예측 생물학적분석 양을 내장하고 있는 모듈, 측정된 생물학적분석 양에 근거하여 급성 및 만성 피폭으로부터 섭취량과 선량을 평가하는 계산모듈 등으로 구성되어 있다. 본 논문은 프로그램의 특성과 검증결과에 대해 기술한다.

  • PDF

Haldane Inhibition at CAH DNAPL Source Zone in Soil and Groundwater

  • Yu, Seung-Ho;Semprini, Lewis
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.33-36
    • /
    • 2004
  • Two biokinetic models (\circled1 Mrichaelis-Menten kinetics with competitive inhibition \circled2 with both competitive inhibition and Haldane inhibition) for reductive dechlorination were developed and compared with results from batch kinetic tests conducted over a wide range of PCE and TCE concentrations with two different dechlorinating cultures. At PCE concentrations lower than 300 $\mu$M, both model simulated the experimental results well. However, The kinetic model that incorporated both competitive and Haldane inhibitions much better simulated experimental data for PCE concentrations greater than 300-400 $\mu$M, and TCE concentrations at half its solubility limit (4000 $\mu$M). The PM culture showed Haldane inhibition constants of 900, 6000, 7000 $\mu$M for TCE, c-DCE and VC, indicating very weak Haldane inhibition for c-DCE and VC, while the EV culture had lower Haldane inhibition constants for TCE, c-DCE, and VC of 900, 750, and 750 $\mu$M, respectively. The BM culture had better transformation abilities than the individual cultures over a wide range of PCE and TCE concentrations. Modeling results indicated that a combination of competitive and Haldane inhibition kinetics is required to simulate dechlorination over a broad range of concentrations up to the solubility limits of PCE and TCE.

  • PDF

바이오어세이 결과 해석에서 단일 섭취경로 가정에 따르는 예탁유효선량의 잠재오차 (Potential Errors in Committed Effective Dose Due to the Assumption of a Single Intake Path in Interpretation of Bioassay Results)

  • 이종일;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.135-140
    • /
    • 2006
  • 비밀봉 방사성물질의 취급 사고시 방사성핵종은 흡입과 취식의 두 가지 경로로 섭취될 수 있다. 이때 일상 감시처럼 하나의 섭취경로만 가정하여 예탁유효선량을 평가하면 심각한 오차를 유발할 수 없다. 이러한 잠재 오차를 제시하기 위해 총 섭취에 대한 흡입섭취의 비율을 달리할 때 예탁유효선량의 변동을 분석하였다. $^{241}Am$(AMAD 5 ${\mu}m$, 흡수형 M)을 대상으로 핵종의 생물역동학적 모델과 데이터를 이용하여 여러 흡입섭취 분율에서 폐, 소변 및 대변에 대한 바이오어세이 측정치를 모의하였다. 섭취 3일 후 예상 측정치를 이용하고 단일 경로 섭취를 가정한 경우 평가된 예탁유효선량의 잠재 오차는 -100%에서부터 많게는 +34,000%에 이르는 것으로 나타났다. 흡입섭취가 있을 때 대변만 분석하면 큰 오차가 발생하였다. 섭취경로 오판에 따르는 선량평가의 오차를 줄이기 위해 두 종류의 바이오어세이를 이용하는 전략을 제안하였다.