• Title/Summary/Keyword: Biofilm reactor

Search Result 191, Processing Time 0.022 seconds

Nitrogen and Phosphorous Removal from Wastewater by SBBR(Sequencing Batch Biofilm Reactor) System (연속회분식 생물막 반응기를 이용한 폐수중의 질소.인 제거)

  • 김조웅;이정복;최대건;임윤택;김두현;황재웅;이용희;반용병
    • KSBB Journal
    • /
    • v.13 no.6
    • /
    • pp.638-643
    • /
    • 1998
  • An investigation was made to develop new biofilm medium which could be applied to the Sequencing Batch Biofilm Reactor(SBBR) system for enhanced nutrient removal. 21 kinds of polyurethane media were tested fro adhesion ability for nitrifying bacteria. Nitrification rates were also tested by introducing synthetic wastewater containing ammonium-nitrogen to reactors with biofilm media. It was found that Z96-06 medium had higher selective adhension ability for nitrifying bacteria than the other biofilm media. The nitrification rate was 2.21 mg {{{{ { NH}`_{4 } ^{ +} }}}}-N /L$.$h$.$g MLSS when we operated the SBBR system containing Z96-06. Nitrification rate of the SBBR system increased approximately by 30% compared with that of the Sequencing Batch Reactor(SBR) system which did not contain biological carrier.

  • PDF

Control of Excessive Biofilm for the Treatment of High Strength Organic Wastewater by Biofilm Process (생물막공법에 의한 고농도 유기폐수 처리시 생물막 과부착 제어)

  • 임재명;권재혁;한동준
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.67-77
    • /
    • 1995
  • This study was performed for minimization of excessive biofilm effects at the high strength organic wastewater treatment. As a results of biofilm attachment experiment using piggery wastewater, aggravation of water quality due to excessive biofilm showed after 15 days of operating times.4 excessive biofilm phase, the equivalent biofilm thickness and VSS contents per unit aura were observed in the range of 1,100 to $1,200{\mu}m$ and 2.5 to 3.0mg $VSS/cm^{2}$, respectively. In the aerobic fixed biofilm reactor/anoxic fixed biofilm reactor(AFBR/ANFBR) process with endogenous respiration phase, the BOD removal efficiency was obtained more than 90 percentage at the surface loading rate and volumetric loading rate of the AFBR maintained less than 17 g $BOD/m^{2}{\cdot}$day and 1.7kg $BOD/m^{3}{\cdot}$day, respectively. The removal efficiency of TKN and $NH_{3}$-N at the loading rates below 5.60g $NH_{3}-N/m^{2}{\cdot}day$ and 0.56kg $NH_{3}-N/m^{3}{\cdot}$day were above 76 percentage and 82 percentage, respectively. In order to reduced sludge production rate and aggravation of water quality, endogenous respiration phase was accepted at first AFBR reactor. As a results of this operating condition, sludge production was minimized and removal efficiency was maintained stability.

  • PDF

A Study on Aerobic Fluidized-Bed Biofilm Reactor for Treating Industrial Wastewaters(III) -Mathematical model for organic removal- (산업폐수처리를 위한 호기성 생물막 유동층 반응기의 연구(III) -유기물 제거에 관한 수학적 모델-)

  • 안갑환;박상준;송승구
    • Journal of Environmental Science International
    • /
    • v.2 no.4
    • /
    • pp.331-336
    • /
    • 1993
  • A mathematical model for organic removal efficiency was investigated in a fluidized bed biofilm reactor by changing the feed flow rate, the residence time and the recycle flow rate. In batch experiment, organic removal could be assumed as first order and an intrinsic first order rate constant(k1) was found $6.4{\times}^{-6}cm^3/mg{\cdot}sec$ at influent COD range of 3040 - 6620 mg/L. In continuous experiment, at the condition of the influent COD, 3040 mg/L, the superficial upflow velocity, 0.47 cm/sec, the biofilm thickness 336 ${\mu}m$ and the biofilm dry density 0.091 g/mL, the calculated COD removal efficiency from the mathematical model gave 60% which was very close to the observed value of 66 %. As the feed flow rate was increased, the COD removal efficiency was sharply decreased and at constant feed flow rate, the COD removal efficiency was decreased also as the residence time being decreased.

  • PDF

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

Study on Head Loss in Aerated Biofilm Filtration Reactor (폭기생물막(曝氣生物膜) 여과지(濾過池)의 여과저항(濾過抵抗)에 관한 연구(研究))

  • Kang, Yong Tae;Hyun, Kil Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.285-291
    • /
    • 1992
  • The purpose of this research, through kinetic analyses and pilot plant experimentation of biofilm filtration reactor, is to study the theoretical equation of head loss in the Biofilm Reactor. The Head loss in the biofilm reactor has occurred due to the biofilm growth and the adhesion to the media surface and stagnation of upflow air bubble, which have caused the pore spaces to become smaller. On a basis of the head loss theory of sand filtration, therefore, the following equation of head loss for the biofilm reactor was proposed from this research results and proved to be possible to apply the equation for practical design of the biofilm filter. $h={\frac{h_o}{L}}{\int}^L_00.58\exp[-4.5){\sigma}_B)][{\frac{1-{\varepsilon}_o+({\sigma}_B)}{1-{\varepsilon}_o}}]^2{[\frac{{\varepsilon}_o}{{\varepsilon}_o-({{\varepsilon}_B)}}]^3dz$ here ${\sigma}_B=0.130+0.001{\theta}$.

  • PDF

The High Rate Denitrification of Nitric Acid Wastewater in a Fluidized Bed Biofilm Reactor (유동층 생물막 반응기를 이용한 고농도 질산성 폐수의 탈질화에 관한 연구)

  • 신승훈;김민수;박동일;안재동;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.95-104
    • /
    • 1997
  • The objectives of this study are to investigate the effect of media on the removal efficiency of nitrate-nitrogen and the biofilm thickness in the fluidized bed biofilm reactor(FBBR) used for the high rate denitrification of nitric acid wastewater. Granular activated carbon(GAC) of 1.274 mm diameter and sand of 0.455 mm diameter were used as the media in the FBBR of 0.05 m diameter and 1.5 m height. As the nitrate-nitrogen concentration of the influent was increased stepwise from 600 to 4800 mg/l, the nitrate- and nitrite-nitrogen concentration of the effluent, biofilm thickness and biofilm dry density were measured to study the effects of media on the denitrification efficiency. The biofilm thickness increased with the substrate loading rate, and the biofilm dry density decreased with the increase of the biofilm thickness. At the influent nitrate-nitrogen concentration of 2400 mg/l, the removal efficiency in the FBBR with GAC was 88%, while that in the FBBR with sand was 99.6%. The biofilm in the FBBR with GAC was so thick, 754.9 $\mu$m, as to increase the mass transfer resistance, compared to that, 143.7 $\mu$m, in the FBBR with sand. The maximum specific denitrification rate in the FBBR with GAC was 15.0 kg-N/m$^3\cdot$ day, while that in the FBBR with sand was 18.0 kg-N/m$^3\cdot$ day. The biomass concentration in the FBBR with sand exhibited the high value 37 kg/m$^3$.

  • PDF

Difference of Microorganisms Found in an Aerated submerged Biofilm Reactor with Different Plastic Media Terating Phenol Wastewater (페놀폐수를 처리하는 침적형 생물막 반응기에서 매질에 따른 미생물상의 차이)

  • 정재춘;차병훈
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.4
    • /
    • pp.492-498
    • /
    • 1995
  • Net type polyvinylidene chloride (PVDC) media and cillium type polyethlene polypropylene (PEPP) media were installed in the aereted submerged biofilm reactors. Synthetic phenol wastewater for feed were made to contain 1,480 mg of phenol per liter of water. The organic loading range of reactors were 0.439-0.456 kg COD/m$_{3}$, 0.882 - 0.919 kg COD/m$_{3}$ and 1.199-1.339 kg COD/m$_{3}$. Comparing PVDC to PEPP media, the bacterial number found in biofilm on PEPP were slightly higher. With the low temperature (10$\circ$C), the number of bacteria was some what deceered. Number of bacterial strains identified from PVDC were 23 and those from PEPP were 42. Genera identified in the PVDC media were Flavobacterium (47.8%), Unidentified (17.6%), Pseudomonas (13.0%), Micrococcus (8.7%) and Beggratoa (8.7%). Genera identified in the PEPP media reactor were Pseudomonas (35.7%), Alcaligenes (19.0%), Aeromonas (14.33%) and Micrococcus (11.9%), In the steady, state, a filamentous bacteria, type 1701 was identified in all of the reactors. Paramecium sp. and fungi were present in the PVDC media reactor. While, Difflugia sp, Paramecium sp. and fungi were found in the PEPP media reactor. The low diversity of protozoa was ascribed to high concentration of phenol.

  • PDF

Effect of Aeration Intensity on the Treatment Efficiency in Submerged Biofilm Process (침지형 생물막공법에 있어서 포기강도가 처리효율에 미치는 영향)

  • 박종웅
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.89-96
    • /
    • 1989
  • An aerated submerged biofilm reactor is the reactor in which influent organic substrates are aerobically oxidized by suspended biomass and attached biomass of biofilm grown on the surface of submerged media. The objective of this study was to investigate the effect of aeration intensity on microbial characteristics and treatment efficiency in submerged biofilm process. In the organic loading rate (4.3kg BOD/$m^{3} \cdot day$), biofilm thickness (420-780$\mu$m) and attached biomass(1.79-2.94mg/cm$^{2}$) increased as the aeration intensity increased (2-8m$^{3}$ air/$m^{2} \cdot hr$), but biofilm density decreased (42.25-37.69mg/cm$^{3}$). The minimum aeration intensity for prevention of deposited biomass was 2m$^{3}$ air/$m^{2} \cdot hr$. The minimum dissolved oxygen of 2.5mg/l had to be maintained for improved efficiency.

  • PDF

Hydraulic Shock of Apartment Sewage in Inverse Fluidized Bed Biofilm Reactor (역유동층 생물막 반응기에서 수리학적 충격에 따른 아파트 오수의 처리)

  • 박영식;나영수
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • The objective of this study was to examine the transient response to hydraulic shocks in an Inverse fluidized bed bioflm reactor(IFBBR) for the treatment of apartment sewage. The hydraulic shock experiments, when the system were reached at steady state with each HRT 12, 7, and 4hr, were conducted by chancing twice HRT per day during 3days. The SCOD, SS, DO, and pH of the effluent stream were increased with hydraulic shock, but easily recovered to the steady state of pre-hydraulic shock condition. In spite of hydraulic shock, there were not much variation of biomass concentration, biofilm thickness and biofilm dry density.

  • PDF

Laboratory Study on the Factors Affecting on Initial Anaerobic Biomass Development (혐기성 부착미생물의 초기성장에 미치는 영향인자에 관한 연구)

  • 허준무;박종안;손부순
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.185-194
    • /
    • 1998
  • Laboratory-scale investigation into initial anaerobic biofilm development was carried out by circulating mixed liquor from a steady-state anaerobic reactor through silicone tubing and then rerurning the mixed liquor to the reactor. The wall of the silicone tubing was the surface upon which anaerobic biofilm accumulation or development was monitored. Methanogenic bacteria accumulation was monitored by F$_{420}$ fluorescence (picomoles F$_{420}$/cm$^{2}$) of the extracted biofilm material. Biofilm accumulation was measured by the increase in COD of the extracted material ($\mu $g COD/cm$^{2}$). Experiments were conducted for 25 days, and biofilm analyses were performed at 5 days intervals. The results indicated that the initial rates of methangen and anaerobic biofilm accumulation increased with increasing organic loading rate and higher initial rates were observed for 15 days than 15 day liquid HRT or SRT. When the initial rates were plotted against the corresponding mixed liquor volatile suspended solids the difference between the results at the two HRT's became much less significant. Thus, the concentration of mixed liquor volatile suspended solids was found to be a very important parameter affecting initial anaerobic biofilm development. The ratio of methanogens to anaerobic biofilm was also investigated. The results showed that the ratio remained constant through the 25 days of each experiment and for high organic loading rates. Based on the results of this research, a reduction, a reduction of start-up period of anaerobic fixed film reactors might be achieved by maintaining a high organic loading and a large concentration of anaerobic microorganisms in the mixed liquor during the start-up period.

  • PDF