• Title/Summary/Keyword: Bioequivalence

Search Result 352, Processing Time 0.024 seconds

Bioequivalence of DilastTM Capsule to Ketas® Capsule (Ibudilast 10 mg) (케타스캅셀(이부딜라스트 10 mg)에 대한 딜라스트캡슐의 생물학적동등성)

  • Chang, Kyu-Young;Kang, Seong-Woo;Yoo, Eun-Ju;Lew, Soo-Hyun;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.197-203
    • /
    • 2007
  • A bioequivalence study of $Dilast^{TM}$ Capsule (Chong Kun Dang Pharma. Co., Ltd.) to $Ketas^{(R)}$ Capsule (Han Dok Pharma. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty eight healthy male Korean volunteers received each medicine at the ibudilast dose of 20 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of ibudilast were monitored by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) for over a period of 36 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 36 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Dilast^{TM}$ $Capsule/Ketas^{(R)}$ Capsule were $log0.93{\sim}log1.06$ and $log0.93{\sim}log1.11$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Thus, our study demonstrated the bioequivalence of $Dilast^{TM}$ Capsule and $Ketas^{(R)}$ Capsule with respect to the rate and extent of absorption.

Bioequivalence Study of Toriem® Tablet to Motilium-M® Tablet (Domperidone Maleate 12.72 mg) Evaluated by Liquid Chromatography/Tandem Mass Spectrometry

  • Ryu, Ju-Hee;Choi, Sang-Jun;Lee, Myung-Jae;Lee, Jin-Sung;Kang, Jong-Min;Tak, Sung-Kwon;Seo, Ji-Hyung;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • The aim of the present study was to evaluate the bioequivalence of two domperidone maleate tablets, Motilium-$M^{(R)}$ Tablet (Janssen Korea Ltd., reference product) and $Toriem^{(R)}$ Tablet (Daewon Pharm. Co., Ltd., test product). Domperidone was extracted by liquid-liquid extraction using tert-butyl methyl ether and separated in less than 3 min on $C_{18}$ reverse-phase column using an isocratic elution. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z $426.1{\rightarrow}119.1$ and the m/z $837.4{\rightarrow}158.2$ transitions for domperidone and the internal standard (roxithromycin), respectively. Calibration curves, from $0.05{\sim}50$ ng/mL of domperidone, showed correlation coefficients (r) higher than 0.9941. Intra day and inter day precision (C.V. %) for quality control were ranged from 10.04 to 16.09% and from 10.87 to 18.69%, respectively. The lower limit of quantification (LLOQ) of domperidone was 0.05 ng/mL. The method described is precise and sensitive and has been successfully applied to the study of bioequivalence of domperidone in 24 healthy Korean volunteers. Twenty-four healthy male Korean volunteers received a single dose of each medicine ($2{\times}12.72\;mg$ domperidone maleate) in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of domperidone were monitored for over a period of 24 hr after the administration. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were within acceptable range of log 0.8 to log 1.25 (e.g., $log\;0.92{\sim}log\;1.05$ for $AUC_{0-t}$, $log\;0.81{\sim}log\;1.05$ for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that $Toriem^{(R)}$ tablet is bioequivalent to Motilium-$M^{(R)}$ tablet.

Bioequivalence of FLUTAL Tablet to SOMALGEN Tablet (Talniflumate 370 mg) (소말겐 정(탈니플루메이트 370 mg)에 대한 플루탈 정의 생물학적동등성)

  • Lee, Heon-Woo;Cho, Sung-Hee;Park, Wan-Su;Im, Ho-Taek;Kim, Young-Kwan;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.303-308
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two talniflumate tablets, SOMALGEN tablet (Kun Wha Pharm. Co., Ltd., Seoul, Korea, reference drug) and FLUTAL tablet (Kukje Pharm. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets at the talniflumate dose of 740 mg in a $2{\pm}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of niflumic acid were monitored by an HPLC-UV for over a period of 14 hr after the administration. $AUC_t$(the area under the plasma concentration-time curve from time zero to 14 hr) was calculated by the linear trapezoidal rule method. $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$, ratio and the $C_{max}$ ratio for SOMALGEN/FLUTAL were $log0.8510{\sim}log1.0318$ and $log0.9264{\sim}log1.0607$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Taken together, our study demonstrated the bioequivalence of SOMALGEN and FLUTAL with respect to the rate and extent of absorption.

Bioequivalence Of SudoTM Ranitidine Hydrochloride Tablet to CuranTM Tablet (Ranitidine Hydrochloride 150 mg) (큐란 정(염산라니티딘 150 mg)에 대한 수도염산라니티딘정의 생물학적동등성)

  • Lee, Sun-Neo;Ko, Youn-Jung;Kang, Seung-Woo;Yoon, Seo-Hyun;Park, Moo-Sin;Lee, Ye-Ri;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.193-199
    • /
    • 2006
  • A bioequivalence study of $Sudo^{TM}$ Ranitidine HCI tablet (Sudo Pharma. Ind. Co., Ltd.) to $Curan^{TM}$ tablet (Il Dong Pharma. Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korean volunteers received each medicine at the ranitidine hydrochloride dose of 150 mg in a 2x2 crossover study. There was a one week wash-out period between the doses. Plasma concentrations of ranitidine were monitored by a high-turbulent liquid chromatography (HTLC) for over a period of 12 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found far all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Sudo^{TM}$ Ranitidine $HCl/Curan^{TM}$ were 0.92-1.00 and 0.90-1.03, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Sudo^{TM}$ Ranitidine HCI and $Curan^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of LosartanTM Tablet to CozzarTM Tablet (Losartan Kalium 50 mg) (코자 정(로자탄 칼륨 50 mg)에 대한 로자르탄 정의 생물학적동등성)

  • Kim, Yong-Won;Park, Wan-Su;Kim, Sung-Su;Seo, Ji-Hyung;Cho, Sung-Hee;Lee, Heon-Woo;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.131-136
    • /
    • 2006
  • The purpose of the present study was to evaluate the bioequivalence of two losartan tablets, $Cozaar^{TM}$ tablet (MSD Korea. Co., Ltd., Seoul, Korea, reference drug) and $Losartan^{TM}$ tablet (DaeWon Pharm. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets at the losartan kalium dose of 100 mg in a $2\;{\time}\;2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of losartan were monitored by an LC-MS/MS for over a period of 12 hr after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Cozaar^{TM}/Losartan^{TM}$ were $log\;0.97{\sim}log\;1.12\;and\;log\;0.93{\sim}log\;1.23$, respectively. These values were within the acceptable bioequivalence intervals of $log\;0.80{\sim}log\;1.25$. Taken together, our study demonstrated the bioequivalence of $Cozaar^{TM}$ and $Losartan^TM$ with respect to the rate and extent of absorption.

Bioequivalence of NimegenTM Soft Capsule to RoAccutane® Soft Capsule (Isotretinoin 10 mg) (로아큐탄 연질캡슐(이소트레티노인 10 mg)에 대한 니메겐 연질캡슐의 생물학적동등성)

  • Yang, Seung-Kwon;La, Sook-Ie;Chang, Kyu-Young;Lee, Yun-Young;Yoon, Mi-Kyeong;Lew, Soo-Hyun;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.4
    • /
    • pp.255-261
    • /
    • 2007
  • A bioequivalence study of $Nimegen^{TM}$ soft capsule (Medica Korea Pharma. Co., Ltd.) to $RoAccutane^{(R)}$ soft capsule (Roche Korea Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Thirty healthy male Korean volunteers received each medicine at the isotretinoin dose of 60 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of isotretinoin were monitored by a high performance liquid chromatography (HPLC) for over a period of 48 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48 hr) was calculated by the linear trapezoidal rule method. $C_{MAX}$ (maximum plasma drug concentration) and $T_{MAX}$ (time to reach $C_{MAX}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{MAX}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{MAX}$ ratio for $Nimegen^{TM}/RoAccutane^{(R)}$ were $log0.860{\sim}log0.98\;and\;log0.85{\sim}log1.00$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Thus, our study demonstrated the bioequivalence of $Nimegen^{TM}\;and\;RoAccutane^{(R)}$ with respect to the rate and extent of absorption.

Bioequivalence of Traline Tablet to Zoloft® Tablet (Sertraline HCI 50 mg)

  • Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.5
    • /
    • pp.317-322
    • /
    • 2011
  • Sertraline HCl, (1S-cis)-4-(3, 4-dichloro-phenyl)-1, 2, 3, 4-tetrahydro-N-methyl-l-naphthalenamine hydrochloride, is a potent and selective serotonin reuptake inhibitor which is used in the treatment of depression and obsessivecompulsive disorders. The purpose of the present study was to evaluate the bioequivalence of two sertraline HCl tablets, Traline tablet (Myungin Pharm. Co. Ltd.) and Zoloft$^{(R)}$ tablet (Pfizer Inc.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of sertraline from the two sertraline HCl formulations was tested using KP VIII Apparatus II method with various dissolution media. Twenty four healthy Korean male volunteers, $23.50{\pm}1.74$ years in age and $64.09{\pm}7.10\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ crossover study was employed. After a single tablet containing 50 mg as sertraline HCl was orally administered, blood samples were taken at predetermined time intervals and the concentrations of sertraline in serum were determined using an online columnswitching HPLC method with UV/Vis detection. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and computer programs (Equiv Test and K-BE Test) were utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and un-transformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, Zoloft$^{(R)}$ tablet, were 0.04, 3.26 and -1.29% for $AUC_t$, $C_{max}$, and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log0.8 to log1.25. Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Traline tablet was bioequivalent to Zoloft$^{(R)}$ tablet.

Bioequivalence of Hana Loxoprofen Sodium Tablet to Dongwha Loxonin® Tablet (Loxoprofen Sodium 60 mg)

  • Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.2
    • /
    • pp.117-123
    • /
    • 2011
  • Loxoprofen sodium, a 2-phenylpropionate non-steroidal anti-inflammatory drug (NSAID), has marked analgesic and antipyretic activities and relatively weak gastrointestinal ulcerogenicity. The purpose of the present study was to evaluate the bioequivalence of two loxoprofen sodium tablets, Hana loxoprofen sodium tablet (Hana Pharm. Co., Ltd.) and Dongwha Loxonin$^{(R)}$ tablet (Dongwha Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of loxoprofen from the two loxoprofen sodium formulations was tested using KP IX Apparatus II method with various dissolution media. Twenty four healthy Korean male volunteers, $22.83{\pm}1.862$ years in age and $69.92{\pm}9.14$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ crossover study was employed. After a single tablet containing 60 mg as loxoprofen sodium was orally administered, blood samples were taken at predetermined time intervals and the concentrations of loxoprofen in serum were determined using a online column-switching HPLC method with UV/Vis detection. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC^t$, $C_{max}$ and $T_{max}$ were calculated, and computer programs (Equiv Test and K-BE Test 2002) were utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and un-transformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, Dongwha Loxonin$^{(R)}$ tablet, were 2.03, 2.99 and -9.49% for $AUC_t$, $C_{max}$, and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log0.8 to log1.25 (e.g., log0.9831~log1.0535 and log0.9455~log1.1386 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Hana loxoprofen sodium tablet was bioequivalent to Dongwha Loxonin$^{(R)}$ tablet.

Some Statistical Considerations on 2×k Crossover Designs for Bioequivalence Trial (생물학적 동등성 시험을 위한 2×k 교차설계법의 통계적 고려)

  • Noh, So-Young;Park, Sang-Gue
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.4
    • /
    • pp.675-686
    • /
    • 2013
  • The Korea Food and Drug Administration(KFDA) recommends the use of a $2{\times}2$ crossover design to assess the bioequivalence of generic drugs. However, a standard $2{\times}2$ crossover design for bioequivalence trials is often considered problematic due to ethical and economic issues as highly variable drugs are usually required by large numbers of subjects when designing the trial. To overcome this problem a $2{\times}4$ crossover design has been a recommended option as per US regulations; in addition, a $2{\times}3$ crossover design has also recently drawn special attention as an efficient alternative. The current KFDA regulation requires an ANOVA table for every bioequivalence study; however, ANOVA tables of $2{\times}4$ and $2{\times}3$ crossover designs have never been published in the literature. This study shows the derivation of tables of analysis of variance for a $2{\times}4$ cross-over design and a $2{\times}3$ cross-over design. We also suggest a sample size formulas for $2{\times}2$, $2{\times}4$ and $2{\times}3$ crossover designs to provide information on the selection of efficient designs for highly variable drugs.

Bioequivalence of LANIDIEM® Tablet 4 mg to Vaxar® Tablet 4 mg(Lacidipine 4 mg) (박사르®정 4 밀리그램(라시디핀 4 mg)에 대한 라니디엠®정 4 밀리그램의 생물학적동등성)

  • Lee, Yun-Young;Kim, Hye-Jin;La, Sookie;Cho, Kyung-Hee;Jang, Moon-Sun;Park, Young-Joon;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.125-131
    • /
    • 2010
  • A bioequivalence study of LANIDIEM$^{(R)}$ tablet 4 mg (Samil. Co., Ltd.) to Vaxar$^{(R)}$ tablet 4 mg (GlaxoSmithKline Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Forty healthy male Korean volunteers were enrolled in the study and thirty six volunteers completed the study according to the protocol. Thirty six volunteers received each medicine at the lacidipine dose of 4 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of lacidipine were monitored by a high performance liquid chromatography - tandem mass spectrometry (LC-MS/MS) for over a period of 24 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for LANIDIEM$^{(R)}$/Vaxar$^{(R)}$ were log 0.8102~log 1.0417 and log 0.8493~log 1.1439, respectively. These values were within the acceptable bioequivalence intervals of log 0.80~log 1.25. Thus, our study demonstrated the bioequivalence of LANIDIEM$^{(R)}$ tablet 4 mg and Vaxar$^{(R)}$ tablet 4 mg with respect to the rate and extent of absorption.