• Title/Summary/Keyword: Bioelectric Signal

Search Result 15, Processing Time 0.026 seconds

A Development of Portable Bioelectric Signal Measurement System for Industrial Workers' Safety (근로자 안전을 위한 휴대용 생리모니터 시스템 개발)

  • 장준근;허웅;변미경;한상휘;김형태;김형조;김정국
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.241-245
    • /
    • 2004
  • In this paper, we implement a portable bioelectric signal measurement system for the safety of industrial workers. The developed system consists of two parts: the one is boielectric signal measurement unit and the other is signal analyzer system with PDA. The former includes signal processing part, A/D convertor, and 8051 based microprocessor, the latter includes software for signal analysis and display. The developed system detects industrial worker's ECG and displays and stores it to PDA. The ECG data in PDA can be transmitted to PC located in a distance, allowing a doctor to review the ECG and make a treatment decision. A doctor analyzes the ECG data and gives medical treatment to industrial worker.

  • PDF

An Experimental Study of Non-Electrolysis Anti-Microfouling Technology Based on Bioelectric Effect

  • Young Wook Kim
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.172-179
    • /
    • 2023
  • Biofouling initiated by biofilm (slime) formation is a key challenge for practical ocean engineering and construction. This study evaluated a new anti-biofilm technology using bioelectricity. The anti-microfouling electrical technology is based on the principles of the bioelectric effect, known as the application of an electrostatic force for biofilm removal. Previously, the electricity was optimized below 0.82V to avoid electrolysis, which can prevent the production of biocides. A test boat comprised of microelectronics for electrical signal generation with electrodes for an anti-biofouling effect was developed. The tests were conducted in the West Sea of Korea (Wangsan Marina, Incheon) for three weeks. The surface biofouling was quantified. A significant reduction of fouling was observed under the bioelectric effect conditions, with approximately 30% enhanced prevention of fouling progress (P<0.05). This technology can be an alternative eco-friendly technique for anti-microfouling that can be applied for canals, vessels, and coastal infrastructure because it does not induce electrolysis.

Effective Body Signal Measurement with the Bioelectric Impedance Analysis (생체 전기 신호에 의한 효율적인 생체 신호 측정)

  • Oh, Se-Yong;Hwang, Dae-Seok;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.955-958
    • /
    • 2005
  • Bioelectrical Impedance Analysis(BIA) can measure body water amount and then body fat mass. The formula is used here FFM=-4.104+0.518H+0.231W+0.130X+4.229S is used, In this work, H is height, R is resistance value, W is weight, X is reactance and S is distinction of sex.

  • PDF

Effective Body Signal Measurement with the Bioelectric Impedance Analysis (효율적인 생체 임피던스 신호 측정에 관한 연구)

  • Oh, Se-Yong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.689-692
    • /
    • 2005
  • Bioelectrical Impedance Analysis(BIA) can measure body water amount and then body fat mass. Locate 4 electrode in palm to measure efficiently and flow current(50kHz, 800uA) in body for measuring voltage and capacitance. And proposed method to measure body fat with hight, weight, age and distinction of sex.

  • PDF

Study on the Development of Meridian Impedance Measurement System (경락 임피던스 측정 시스템 개발에 관한 연구)

  • Lee, Woo-Cheol;Yin, Chang-Shik;Min, Kyoung-Kee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

Development and Applications of a Wireless Bioelectric Signal Measurement System on the Electrodes (전극 상의 일체형 무선 생체전기신호 측정 시스템 개발 및 응용)

  • Joo, Se-Gyeong;Kim, Hee-Chan
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.88-94
    • /
    • 2003
  • Electromyogram (EMG) is the bioelectric signal induced by motor nerves. Analyzing EMG with the movement produced by muscle contraction, we can provide input commands to a computer as a man-machine interface as well as can evaluate the patient's motional abnormality. In this paper, we developed an integrated miniaturized device which acquires and transmits the surface EMG of an interested muscle. Developed system measures $60{\times}40{\times}25mm$, weighs 100g. Using an amplifier circuitry on the electrodes and the radio frequency transmission, the developed system dispenses with the use of cables among the electrodes, amplifier, and the post processing system (personal computer). The wiring used in conventional systems can be obstacle for natural motion and source of motion artifacts. In results, the developed system improves not only the signal-to-noise ration in dynamic EMG measurement, but also the user convenience. We propose a new human-computer interface as well as a dynamic EMG measurement system as a possible application of the developed system.

Source Current Reconstruction Based on MCG Signal (심자도 신호를 이용한 전류원 재구성)

  • 권혁찬;이용호;김진목
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.48-52
    • /
    • 2002
  • When applying a SQUID system for diagnosing heart disease, it is informative to obtain the source current distributions from the measured MCG (magnetocardiogram) signals since the bioelectric activity in the heart is generally represented by distributed current sources. In order to estimate the Primary current distribution in a heart, the minimum norm estimate was computed, assuming a source plane below the chest surface. In the simulation, current distributions, which were computed for the test dipoles represented well the essential feature of the test-current configurations. Source current reconstruction was performed for MCG signal of a healthy volunteer, which was recorded using a 40-channel SQUID system in a magnetically shielded room. It was found that the obtained current distribution is consistent with the electrical activity in a heart.

  • PDF

Development of Exercise Analysis System Using Bioelectric Abdominal Signal (복부생체전기신호를 이용한 운동 분석 시스템 개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.183-190
    • /
    • 2012
  • Conventional physical activity monitoring systems, which use accelerometers, global positioning system (GPS), heartbeats, or body temperature information, showed limited performances due to their own restrictions on measurement environment and measurable activity types. To overcome these limitations, we developed a portable exercise analysis system that can analyze aerobic exercises as well as isotonic exercises. For bioelectric signal acquisition during exercise, waist belt with two body contact electrodes was used. For exercise analysis, the measured signals were firstly divided into two signal groups with different frequency ranges which can represent respiration related signal and muscular motion related signal, respectively. After then, power values, differential of power values, and median frequency values were selected for feature values. Selected features were used as inputs of support vector machine (SVM) to classify the exercise types. For verification of statistical significance, ANOVA and multiple comparison test were performed. The experimental results showed 100% accuracy for classification of aerobic exercise and isotonic resistance exercise. Also, classification of aerobic exercise, isotonic resistance exercise, and hybrid types of exercise revealed 92.7% of accuracy.

Development of a Excercise Prescription Device using EMG Signal (근전도 신호를 이용한 운동 처방 장치 개발)

  • Kim, Ho-joon;Lee, Jun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.152-157
    • /
    • 2012
  • In this paper, we develop a muscle exercise prescription system and present a prescription method by analyzing bioelectric signal of human muscles. This system is designed to give right exercise prescriptions include strength, duration, frequency of exercise after diagnosing personal body condition using EMG(Electromyography). With the help of these prescriptions all users can keep there optimum exercise status and avoid excess exercise symptom and, we van utilize in all the measurements like abnormal posture, muscle power, muscle regidity, muscle fatigue, muscle balance. Also easily accessable system can offer variable utilizations such as in health care center, sports center, social welfare center, social medical center, school, and kinder garden.

Survey for Needs of Bio-Signal Devices for the Diagnosis, Assessment, or Analysis of Neurocognitive Disorder in Korean Society of Oriental Neuropsychiatry (인지 장애 진단·평가·분석을 위한 생체신호 장비 개발에 대한 수요조사: 한방신경정신과학회 회원들을 대상으로)

  • Choi, Yujin;Kim, Ji Hye;Kim, Kahye;Kim, Jaeuk
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.2
    • /
    • pp.89-99
    • /
    • 2020
  • Objectives: The purpose of this study was to identify the needs of bio-signal devices for the diagnosis, assessment, and analysis of neurocognitive disorder in Korean medicine (KM) hospitals and clinics. Methods: A questionnaire was developed to survey the current status of medical device use, and diagnosis and interventions for patients with cognitive disorders in KM hospitals and clinics. November 11~December 2, 2019, 114 responses (71.9% completed) were collected by internet-based questionnaires from the members of the Korean society of Oriental Neuropsychiatry. Results: The clinical requests were in the descending order of hematology analyzer, ultrasound imaging system, and electroencephalography among the 15 most commonly used devices of which research would support for their clinical usability. The biosignal-based devices showed the highest research demands for patients with mild cognitive impairment rather than more severe stages of cognitive impairment. Prevention rather than diagnosis, or several treatment regimens was the strongest clinical area of the KM for patients with neurodegenerative cognitive impairment. Many responded that five to 10 minutes of test duration and 20,000 won to 30,000 won of cost would be appropriated for a new device to be developed. Conclusions: There were strong demands for the development of bio-signal devices for neurocognitive disorders among the KM doctors. Specifically, it showed high needs for the technology that can be used in the prevention area of cognitive disorders. Additionally, new medical devices to assess cognitive functions and to obtain KM pattern-related information were the high needs.