• 제목/요약/키워드: Biodegradable metal

검색결과 41건 처리시간 0.026초

치과용 Ni-Cr 합금의 조성에 따른 세라믹의 색차 분석 (Ceramic color differences of dental Ni-Cr alloy by compositional change)

  • 김사임;김태연;김세하;강정규;이정환
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.168-174
    • /
    • 2021
  • Purpose: This study was conducted to investigate alloys spectrophotometrically including yttrium of nickel-chromium (Ni-Cr) alloys, which are used as substitutes for the regulation of beryllium and provide helpful improvements in Ni-Cr alloys. Methods: Four groups of specimens (ZN, ZY, SN and EM) were prepared for analysis. Color parameters were measured with a spectrophotometer, and color difference (∆E*) was calculated. The t-test and one-way analysis of variance test were used to determine significant difference, and the Tukey test was used to identify where the differences were. To measure the spectroscopic reflectivity, the spectroscopic reflectance was measured and converted into CIE L*, a*, b* color system. Results: The ∆E* value of each metal ceramic group after opaque firing of Ni-Cr alloy with and without yttrium was <2, and the total group color difference (∆E*) was below 1 in the dentin ceramic all experimental group. However, the a* and b* values of the metal ceramic groups were higher than that in the lithium disilicate all ceramic group, and the chroma was higher than the natural tooth. The brightness of all experimental groups was similar to that of the shade guide sample. Conclusion: Yttrium added to Ni-Cr alloys showed similar CIE L*, a*, b* values to Ni-Cr alloys that did not contain yttrium, indicating that yttrium had no effect on color in metallic ceramic systems.

흡수성 반월상 연골나사를 사용한 얇은 골연골 골절의 치료 - 증례 보고 - (Biodegradable Meniscus Screw Fixation of Thin Flap Osteochondral Fracture - Two Case Report -)

  • 전재균;선두훈;송인수;김영우;정재용;이봉주
    • 대한관절경학회지
    • /
    • 제14권2호
    • /
    • pp.131-134
    • /
    • 2010
  • 관절내 골연골 골절은 적절한 치료가 이루어 지지 않은 경우 골관절염을 초래하여 통증과 기능장애를 초래할 수 있다. 골 연골 골절의 크기가 큰 경우에는 관혈적 정복 및 금속고정 수술등으로 치료를 할 수 있으나, 골편의 두께가 2mm 이하로 얇은 경우 튼튼한 고정력을 얻기 어려워 제거 하는 경우가 많았다. 저자들은 대퇴 내과에 발생한 박리성 골연골염 환자와 슬개골 골절로 골편의 두께가 2mm이하인 환자에서 흡수성 반월상 연골나사를 이용하여 좋은 결과를 얻었기에 보고하고자 한다.

  • PDF

과열(過熱) 증기(蒸氣)를 이용한 국내 폐기물(廢棄物) 유기성(有機性) 성분의 분해(分解) 특성 연구 (Degradation of Organic Component in MSW by Super-heated Steam)

  • 김우현;노선아;민태진;성현제;박성범;장하나
    • 자원리싸이클링
    • /
    • 제18권6호
    • /
    • pp.10-17
    • /
    • 2009
  • 과열 증기를 이용하여 생활 폐기물내 유기성 성분의 분해를 수행하고 폐기물의 특성 및 반응 시간이 폐기물의 분해율에 미치는 영향을 살펴보았다. 과열 증기를 이용한 분해 후 음식 및 폐지와 같은 생분해성 유기 성분은 쉽게 분해되었고 생분해성 유기 성분중 나무와 석유계 유기성 성분인 플라스틱, 금속과 같은 무기성 성분이 분해되지 않은 상태로 남아 쉽게 분리가 가능한 상태를 형성하였다. 입자의 크기 변화를 살펴본 결과 폐기물 내 생분해성 유기 성분이 적을수록 짧은 반응 시간에도 높은 입자 크기 감소를 보였으며 반응 시간이 60분 이상에서 최대 90% 이상의 입도 감소를 나타내었다.

생분해성 고분자 스텐트를 위한 나선헝 구조의 팽창력 연구 (Study on Radial Force of Helical Structure for Biodegradable Polymer Stents)

  • 박철호;박가람;최지연;박귀덕;한동근
    • 폴리머
    • /
    • 제35권3호
    • /
    • pp.260-264
    • /
    • 2011
  • 생분해성 고분자 스텐트는 상대적으로 향상된 생체적합성 및 낮은 부작용으로 기존의 비분해성 금속 스텐트를 대체하기 위해 이슈가 되고 있다. 기본적으로 오든 스텐트들은 확장된 혈관의 직경을 유지하기 위해 요구되는 기계적 강도, 특히 압축력 또는 팽창력을 가져야만 한다. 따라서 본 연구는 나선형 구조테를 제안하였으며, 측면 압축력과 구조적 인자들과의 관련성에 집중하였다. 실린더의 구조체와 달리, 나선형 구조체의 팽창력은 두께와 길이에 1차승으로 비례하고, 직경은 1.6지승의 반비례 관계를 가지고 있었다. 하지만 간극 사이의 거리는 하중과 관련성을 보이지 않았다. 본 연구에서 얻어진 이러한 함수는 임상 적용 스텐트를 설계하고 제조하는데 기초적인 정보를 제공할 수 있다.

흡수성 고정판과 나사를 이용한 중수골 골절의 치료 (Treatment of Metacarpal Bone Fracture Using Biodegradable Plates and Screws)

  • 조정목;은석찬;백롱민
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.458-464
    • /
    • 2011
  • Purpose: Metacarpal fractures are common hand injury that may require operative intervention to ensure adequate reduction and stabilization. Traditionally, titanium miniplate was used for rigid fixation of bone fractures. However, the use of permanent plate lends itself to multiple complications such as infection, exposure of the hardware, tendon adhesions, tendon rupture, prolonged pain, bony atrophy and osteoporosis (stress shielding), metal sensitization, and palpation under the skin. This study evaluated the usefulness and stability of biodegradable plates and screws for treatment of metacarpal bone fractures. Methods: There was 17 patients who had surgery for metacarpal bone fracture from April 2007 to June 2010. All patients had open reduction and internal fixation. We used absorbable plates and screws (Inion CPS$^{(R)}$) for internal fixation. Postoperative results were assessed with x-ray. Stability of plates and screws, healing process and its complications were observed by clinical and radiographic assessment. Results: All patients were successfully reduced of bone fracture, and fixations with absorbable plates and screws were stable. The mean follow up period was 7.1 months. 2 patients complained postoperative pain, but they were relieved with analgesics. All patients experienced transient stiffness, but they were relieved with active assistive range of motion after removal of splint. No patients suffered complications which could be occurred by using metallic plate. Conclusion: There was no critical complications such as re-fracture or nonunion among patients. No patients suffered side effects related with metallic implants. Biodegradable implants can offer clinically stable and attractive alternative to metallic implants to stabilize metacarpal bone fractures in the hand.

수용성 Chitosan 유도체를 이용한 중금속 이온 흡착에 관한 연구 (A Study on Adsorption of Heavy Metal Ions Using Water-soluble Chitosan Derivative)

  • 이광일;곽천근;김영주;장병만;김상호;이기창
    • 한국응용과학기술학회지
    • /
    • 제13권2호
    • /
    • pp.85-92
    • /
    • 1996
  • Chitosan itself has been prepared using chitin, one of the most abundant compounds in nature, as a starting material. We have synthesized the water-soluble chitosan derivative, N-dithiocarboxy chitosan sodium salt, through the reaction of water-soluble chitosan with carbon disulfide in the presence of alkali metal hydroxide. To elucidate this natural polymer capacity of adsorbing heavy metal ions, we have performed adsorption experiments using the water-soluble chitosan derivative various average molecular weight and of different percent contents of sulfur. The effect of pH, adsorption time and temperature on adsorption efficiency was also studied. The adsorbent derived from water-soluble chitosan of average molecular weight ranging $9,000{\sim}120,000$ was shown to have the highest capacity of adsorbing heavy metal ions. On the whole, adsorbing efficiency was increased as the reaction time goes longer and also increased as the reaction temperture goes higer in temperture range of $15^{\circ}C{\sim}45^{\circ}C$. The adsorption capacity at various pH, however, was appeared to vary depending on the heavy metal ions studied Judging from these finding, water-soluble N-dithiocarboxy chitosan sodium salt, a derivative of a biodegradable nature polymer, is believed to be a potential adsorbent for heavy metal ions since it not only is shown to lower the concentration of heavy metal ions to below the drainage quality standard, but also it would not cause acidification and hardening of soil which is one of the detrimental effects of synthetic macromolecular adsorbents present.

패션분야의 3D 프린팅 활용 현황에 관한 연구 (Study on Status of Utilizing 3D Printing in Fashion Field)

  • 김효숙;강인애
    • 한국의상디자인학회지
    • /
    • 제17권2호
    • /
    • pp.125-143
    • /
    • 2015
  • This study has investigated the status of utilizing 3D printing in fashion field in order to keep up with the trend for 3D printing technology to be realized in all industries so that the materials and the modeling modes may be figured out. The following is the findings. The materials used most in 3D printing in fashion field are PA, PLA, TPU, multi-material, ABS and metal. PA, TPU and Multi-material have so much excellent flexibility and strength that they are widely used for garment, shoes and such fashion items as bags. But PLA, ABS and metal are scarcely used for garment because PLA is easily biodegradable in the air, ABS generates harmful gas in the process of manufacture and metal is not flexible, while all of these three are partly used for shoes and accessories. The modeling modes mainly applied for 3D printing in fashion field are SLS, SLA, FDM and Polyjet. SLS, which is of a powder-spraying method, is used for making 3D textile seen just like knitting. Polyjet method, which has higher accuracy and excellent flexibility, can be used for expressing diverse colors, and accordingly it is used a lot for high-quality garment, while SLA and FDM method are found to be mostly used for manufacturing shoes and accessories rather than for making garment because they are easily shrunk to result in deformation.

  • PDF

다양한 금속 이온을 이용한 카세인 단백질 나노입자 형성 및 약물 전달체 특성 연구 (Preparation and Characterization of Casein Nanoparticles with Various Metal Ions as Drug Delivery Systems)

  • 김민주;이슬기;최준식
    • 공업화학
    • /
    • 제34권2호
    • /
    • pp.121-125
    • /
    • 2023
  • 카세인(casein)은 포유류의 우유에서 발견되는 단백질로 우유에서는 80% 이상 함유되어 있다. 사람의 모유에는 약 20~45%가 포함되어 있으며 생체 적합성이 높아 의료 및 산업 소재로 사용되고 있다. 카세인은 양친매성 구조로 내부는 소수성이기 때문에 수용액에서 마이셀로 자가 조립이 가능하여 난용성 약물을 봉입할 수 있다. 또한, 단백질 고분자 소재로 생분해성을 갖고 있어 약물의 전달체로서 적합한 특징을 가진다. 본 연구에서는 칼슘 이온 외에 마그네슘, 아연, 철 등 생체 내 존재하는 다양한 금속 이온들을 사용하여 각각 효과적인 카세인 나노입자 형성 조건을 규명하였다. 동적 광산란 측정기와 제타 전위 측정을 통해 150 nm 이하의 균일한 사이즈를 유지하고 음전하를 띠는 나노입자가 형성됨을 확인하였다. 또한, 각각의 카세인 나노입자가 HeLa 세포주에서 80% 이상의 생존율을 나타내 낮은 세포 독성을 확인하였고, 카세인 나노입자 내부에 시험 약물로서 나일 레드를 봉입하여 세포 내부로 효과적으로 유입됨을 공초점 현미경으로 입증하였다. 본 실험들을 통해 제조된 카세인 나노입자의 약물 전달체로서의 가능성을 확인하였다.

Fabrication and Characterization of the Ti-TCP Composite Biomaterials by Spark Plasma Sintering

  • Mondal, Dibakar;Park, Hyun-Kuk;Oh, Ik-Hyun;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.53.2-53.2
    • /
    • 2011
  • Ti metal has superior mechanical properties along with biocompatibility, but it still has the problem of bio-inertness thus forming weaker bond in bone/implant interface and long term clinical performance as orthopaedic and dental devices are restricted for stress shielding effect. On the other hand, despite the excellent biodegradable behavior as being an integral constituent of the natural bone, the mechanical properties of ${\beta}$-tricalcium phosphate $(Ca_3(PO_4)_2;\;{\beta}-TCP)$ ceramics are not reliable enough for post operative load bearing application in human hard tissue defect site. One reasonable approach would be to mediate the features of the two by making a composite. In this study, ${\beta}$-TCP/Ti ceramic-metal composites were fabricated by spark plasma sintering in inert atmosphere to inhibit the formation of $TiO_2$. Composites of 30 vol%, 50 vol% and 70 vol% ${\beta}$-TCP with Ti were fabricated. Detailed microstructural and phase characteristics were investigated by FE-SEM, EDS and XRD. Material properties like relative density, hardness, compressive strength, elastic modulus etc. were characterized. Cell viability and biocompatibility were investigated using the MTT assay and by examining cell proliferation behavior.

  • PDF

산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(I) (A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(I))

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제18권1호
    • /
    • pp.49-60
    • /
    • 2009
  • Fabrication and oxidants formation of 1 and 2 component metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru, Pt, Sn, Sb and Gd) were used for the 1 and 2 component electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1 h. The removed RhB per 2 min and unit W for one component electrode decreased in the following sequences: Ru/Ti>Sb/Ti>Pt/Ti>Gd/Ti>Sn/Ti. The concentration of oxidants generated in 1 and 2 component electrodes was in the order of: $ClO_2$> free Cl>$H_2O_2>O_3$. OH radical was not generated from in entire one and two component electrodes. RhB degradation rate and generated oxidants of the Ru-Sn=9:1 electrode was higher than that of the two component electrode. The exact relationship between the removal of RhB and the generated oxidants concentration was not obvious. However, it was assumed that electrode with high RhB decolorization had high oxidant concentration.