• 제목/요약/키워드: Biocompatibility materials

검색결과 405건 처리시간 0.024초

Characterization of Silk Fibroin/S-carboxymethyl Kerateine Surfaces: Evaluation of Biocompatibility by Contact Angle Measurements

  • Lee, Kuen-Yong
    • Fibers and Polymers
    • /
    • 제2권2호
    • /
    • pp.71-74
    • /
    • 2001
  • Surface characterization of materials has been considered critical in the development of biomaterials, as many unfavorable responses from the body occur at the interface between a material and the body component. The contact angle measurement is one means to characterize the surface properties and to correlate them to the biocompatibility of materials. In this paper, surface characteristics of silk fibroin/S-carboxymethyl kerateine, representative fibrous proteins, were investigated by contact angle measurements of ESCA. The biocompatibility of the blends was evaluated based on minimal interfacial free energy concept, and compared with other potential biomaterials. It was also hypothesized that the enhanced surface polarity of the blends was generated from the conformational transition of proteins. This approach to evaluate the biocompatibility of materials based on surface characteristics may find wide utility in many biomedical applications.

  • PDF

침 금속재료에 대한 생체적합성 연구 - 생물학적 특성을 중심으로(2) - (A Study of Biocompatibility of Acupuncture's Metal Materials - Focused on Biological Character (2) -)

  • 정인태;강중원;백용현;이상훈;이재동;최도영
    • 대한한의학회지
    • /
    • 제26권2호
    • /
    • pp.166-175
    • /
    • 2005
  • Objecitve: To present criteria for acupuncture standardization, which will improve the quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture needles. Methods: Acupuncture needles distributed in Korea were studied. Acute poisonous tests and pyrogenicity materials tests were executed to study the biocompatibility of acupuncture needles. Results & Conclusions: All 3 brands of acupuncture needles commonly distributed in Korea were found suitable for medical use, through acute poisonous tests and pyrogenicity materials tests. However, the medical instrument standards of the Korea Food and Drug Administration for acupuncture lack criteria concerning acute poisonous tests and pyrogenicity materials tests. The criteria for these tests should be standardized in order to secure the biocompatibility of acupuncture needles.

  • PDF

Effect of Bioactive Glass Addition to the TTCP/DCPA Based Injectable Bone Substitute for Improved Biocompatibility

  • Sadiasa, Alexander;Sarkar, Swapan Kumar;Franco, Rose Ann;Yang, Hun-Mo;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.52.1-52.1
    • /
    • 2011
  • In this work, the effect of the addition of bioactive glass in the biocompatibility and mechanical behavior of conventional TTCP/DCPA based bone cement were investigated. The cement was initially modified with chitosan and HPMC which cross-linked with citric acid to improved mechanical properties.The injectable bone substitutes were further modified by adding varying amounts of bioactive glass (0%, 10%, 20% and 30%) and its effects on the biocompatibility of the material were studied. Afterbio-glass powders were mixed with the optimized composition for HPMC and citric acid content,the IBS was incubated at $37^{\circ}C$ at different time intervals and showed progressive formation of HAp with increasing time. Mechanical properties like Vickers hardness and compressive strength were found to increase with the increasing amount of bioactive glass addition and that setting time was shortened. The fabricated IBS morphologies were further characterized using SEM. MTT assay was performed to check the cell cytotoxicity and cell proliferation for 1, 3 and 5 days. Cell morphology, adhesion and proliferation behavior of cell in the IBS by culturing MG-63 cells on the IBS for 20, 60 and 90 mins and 1, 3 and 5 days was also investigated. All the results showed increasing biocompatibility as the bioglass content increased. MTT results found the materials to be cytocompatible and SEM images showed that cells attached and proliferated successfully.

  • PDF

DV-Xα 분자궤도법으로 설계한 생체용 Ti-Ag-Zr 합금 특성 평가 (A Study on the Properties of Design for the Biomaterial Ti-Ag-Zr Alloys Using DV-Xα Molecular Orbital Method)

  • 백민숙;윤동주;김병일
    • 한국재료학회지
    • /
    • 제24권4호
    • /
    • pp.175-179
    • /
    • 2014
  • Ti and Ti alloys have been extensively used in the medical and dental fields because of their good corrosion resistance, high strength to density ratio and especially, their low elastic modulus compared to other metallic materials. Recent trends in biomaterials research have focused on development of metallic alloys with elastic modulus similar to natural bone, however, many candidate materials also contain toxic elements that would be biologically harmful. In this study, new Ti based alloys which do not contain the toxic metallic components were developed using a theoretical method (DV-$X{\alpha}$). In addition, alloys were developed with improved mechanical properties and corrosion resistance. Ternary Ti-Ag-Zr alloys consisting of biocompatible alloying elements were produced to investigate the alloying effect on microstructure, corrosion resistance, mechanical properties and biocompatibility. The effects of various contents of Zr on the mechanical properties and biocompatibility were compared. The alloys exhibited higher strength and corrosion resistance than pure Ti, had antibacterial properties, and were not observed to be cytotoxic. Of the designed alloys' mechanical properties and biocompatibility, the Ti-3Ag-0.5Zr alloy had the best results.

천연 및 인공원료로부터 제조한 생체친화형 하이드록시아파타이트 세라믹스 (Biocompatible Hydroxyapatite Ceramics Prepared from Natural Bones and Synthetic Materials)

  • 이종국;고영화;이난희
    • 한국재료학회지
    • /
    • 제22권6호
    • /
    • pp.285-291
    • /
    • 2012
  • Hydroxyapatite (HA) is well known as a biocompatible and bioactive material. HA has been practically applied as bone graft materials in a range of medical and dental fields. In this study, two types of dense hydroxyapatite ceramics were prepared from natural bones and synthetic materials. The biocompatibility of HA ceramics for supporting osteoblast cell growth and cytotoxicity using an in vitro MG-63 cell line model were respectively evaluated. Artificial hydroxyapatite shows relative density of 93% with 1-2 ${\mu}m$ after sintering, but a hydroxyapatite compact derived from bovine bone has low sintered density of 85% with a small content of MgO. Irrespective of the starting raw materials, both types of sintered hydroxyapatite displayed similar biocompatibility in the tests. FE-SEM observations showed that most MG-63 cells had a stellar shape and formed an intercellular matrix containing fibers on sintered HA. The cells were well attached and grown over the HA surface, indicating that there was no toxicity.

Biocompatibility of root-end filling materials: recent update

  • Saxena, Payal;Gupta, Saurabh Kumar;Newaskar, Vilas
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.119-127
    • /
    • 2013
  • The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.

침 금속재료에 대한 생체적합성 연구 -생물학적 특성을 중심으로- (A Study for Biocompatibility of Acupuncture′s Metal Materials, - Focused on Biological Character -)

  • 백용현;정인태;이상훈;이재동;최도영
    • 대한한의학회지
    • /
    • 제25권3호
    • /
    • pp.180-190
    • /
    • 2004
  • Objectives : To present criteria for acupuncture standardization, which will improve quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture materials. Methods : Acupuncture needles distributed in Korea were studied. Intracutaneous reaction tests and sterility tests were executed to study the biocompatibility of acupuncture. Results & Conclusions : All 4 kinds of acupuncture needles distributed in Korea were found suitable for medical use, through intracutaneous reaction tests and sterility tests. However, the medical instrument standards of the Korea Food and Drug Administration lack criteria concerning intracutaneous reaction tests and sterility tests. The criteria for these tests should be standardized in order to secure the biocompatibility of acupuncture needles.

  • PDF

Nanowire Patterning for Biomedical Applications

  • Yun, Young-Sik;Lee, Jun-Young;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.382-382
    • /
    • 2012
  • Nanostructures have a larger surface/volume ratio as well as unique mechanical, physical, chemical properties compared to existing bulk materials. Materials for biomedical implants require a good biocompatibility to provide a rapid recovery following surgical procedure and a stabilization of the region where the implants have been inserted. The biocompatibility is evaluated by the degree of the interaction between the implant materials and the cells around the implants. Recent researches on this topic focus on utilizing the characteristics of the nanostructures to improve the biocompatibility. Several studies suggest that the degree of the interaction is varied by the relative size of the nanostructures and cells, and the morphology of the surface of the implant [1, 2]. In this paper, we fabricate the nanowires on the Ti substrate for better biocompatible implants and other biomedical applications such as artificial internal organ, tissue engineered biomaterials, or implantable nano-medical devices. Nanowires are fabricated with two methods: first, nanowire arrays are patterned on the surface using e-beam lithography. Then, the nanowires are further defined with deep reactive ion etching (RIE). The other method is self-assembly based on vapor-liquid-solid (VLS) mechanism using Sn as metal-catalyst. Sn nanoparticle solutions are used in various concentrations to fabricate the nanowires with different pitches. Fabricated nanowries are characterized using scanning electron microscopy (SEM), x-ray diffraction (XRD), and high resolution transmission electron microscopy (TEM). Tthe biocompatibility of the nanowires will further be investigated.

  • PDF

Fabrication and Characterization of the Ti-TCP Composite Biomaterials by Spark Plasma Sintering

  • Mondal, Dibakar;Park, Hyun-Kuk;Oh, Ik-Hyun;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.53.2-53.2
    • /
    • 2011
  • Ti metal has superior mechanical properties along with biocompatibility, but it still has the problem of bio-inertness thus forming weaker bond in bone/implant interface and long term clinical performance as orthopaedic and dental devices are restricted for stress shielding effect. On the other hand, despite the excellent biodegradable behavior as being an integral constituent of the natural bone, the mechanical properties of ${\beta}$-tricalcium phosphate $(Ca_3(PO_4)_2;\;{\beta}-TCP)$ ceramics are not reliable enough for post operative load bearing application in human hard tissue defect site. One reasonable approach would be to mediate the features of the two by making a composite. In this study, ${\beta}$-TCP/Ti ceramic-metal composites were fabricated by spark plasma sintering in inert atmosphere to inhibit the formation of $TiO_2$. Composites of 30 vol%, 50 vol% and 70 vol% ${\beta}$-TCP with Ti were fabricated. Detailed microstructural and phase characteristics were investigated by FE-SEM, EDS and XRD. Material properties like relative density, hardness, compressive strength, elastic modulus etc. were characterized. Cell viability and biocompatibility were investigated using the MTT assay and by examining cell proliferation behavior.

  • PDF

Designing Materials for Hard Tissue Replacement

  • Nath, Shekhar;Basu, Bikramjit
    • 한국세라믹학회지
    • /
    • 제45권1호
    • /
    • pp.1-29
    • /
    • 2008
  • In last two decades, an impressive progress has been recorded in terms of developing new materials or refining existing material composition/microstructure in order to obtain better performance in biomedical applications. The success of such efforts clearly demands better understanding of various concepts, e.g. biocompatibility, host response, cell-biomaterial interaction. In this article, we review the fundamental understanding that is required with respect to biomaterials development, as well as various materials and their properties, which are relevant in applications, such as hard tissue replacement. A major emphasize has been placed to present various design aspects, in terms of materials processing, of ceramics and polymer based biocomposites, Among the bioceramic composites, the research results obtained with Hydroxyapatite (HAp)-based biomaterials with metallic (Ti) or ceramic (Mullite) reinforcements as well as $SiO_2-MgO-Al_2O_3-K_2O-B_2O_3-F$ glass ceramics and stabilized $ZrO_2$ based bioinert ceramics are summarized. The physical as well as tribological properties of Polyethylene (PE) based hybrid biocomposites are discussed to illustrate the concept on how can the physical/wear properties be enhanced along with biocompatibility due to combined addition of bioinert and bioactive ceramic to a bioinert polymeric matrix. The tribological and corrosion properties of some important orthopedic metallic alloys based on Ti or Co-Cr-Mo are also illustrated. At the close, the future perspective on orthopedic biomaterials development and some unresolved issues are presented.