Chitosan-alginate를 이용한 돼지 일차 간세포의 캡슐화 및 간기능 활성

  • Lee, Ji-Hyeon;Lee, Du-Hun;Kim, Sang-Gyu;Park, Jeong-Geuk;Kim, Seong-Gu
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.468-470
    • /
    • 2001
  • Chitosan-alginate capsules were formed by the electrostatic interactions and had appropriate mechanical strength, permeability to albumin and stability to hepatocyte. Pig hepatocytes were isolated and immobilized in chitosan-alginate capsules. Encapsulation in 3 minutes and spheroid formation period of 24 hours were optimum condition for the high liver function. Pig hepatocytes density of $90.{\times}10^6$ cells/mL in capsules was suitable for the application to bioartificial liver support system.

  • PDF

The Concept of Artificial Liver Support by Using the Extracorporeal Circulation System

  • Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.1
    • /
    • pp.25-28
    • /
    • 2015
  • In this study, a basic research on artificial liver was performed for its application to people on the waiting list of liver transplant or patients with hepatic insufficiency. Artificial livers are generally classified into mechanic type, bioartificial type, and hybrid type. An extracorporeal circulation device was examined herein, which is indispensable in the application of an artificial liver, for its effectiveness in supporting the recovery of liver functions. Extracorporeal circulation system is a treatment and life-support system which sends out the patient's blood, removes toxicity by various methods, and then sends the blood back to the interior of the body. This study used an extracorporeal circulation system which enables the Plasma Perfusion by CVVH method, and applied the program of Bioateco corp. Animals with acute hepatic insufficiency were produced to apply the extracorporeal circulation device. As a result, their ammonia, bilirubin, SGOT, SGPT, and bile acid levels rose, confirming the liver function restoration in the experimental animals.

A cost-effective and simple culture method for primary hepatocytes

  • Adaya, Sezin;Hasircib, Nesrin;Gurhana, Ismet Deliloglu
    • Animal cells and systems
    • /
    • v.15 no.1
    • /
    • pp.19-27
    • /
    • 2011
  • Hepatocytes, the major epithelial cells of the liver, maintain their morphology in culture dishes coated with extracellular matrix (ECM) components such as collagen and fibronectin or biodegradable polymers (e.g. chitosan, gelatin). In these coated dishes, survival of cells and maintaining of liver-specific functions may increase. The aim of this study was to determine a suitable, cost-effective and simple system for hepatocyte isolation and culture which may be useful for various applications such as in vitro toxicology studies, hepatocyte transplantation and bioartificial liver (BAL) systems. In order to obtain primary cultures, hepatocytes were isolated from liver by an enzymatic method and cultured on plates coated with collagen, chitosan or gelatin. Collagen, gelatin-sandwich and gelatin-cell mixture methods were also evaluated. Morphology and attachment of the cells were observed by inverted microscope and scanning electron microscope (SEM). An MTT assay was used to determine cell viability and mitochondrial activity.

Effects od Segree of Cell-Cell Contact on Liver Specific Function of Rat Primary Hepatocytes

  • Tang, Sung-Mun;Lee, Doo-Hoon;Park, Jung-Keug
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.2
    • /
    • pp.99-105
    • /
    • 2000
  • Cell-Cell interaction and the extracellular matrix (ECM) are belisved to play essential roles during in vitro culturing of primary hepatocytes in the control of differentiation and in the maintenance of tissue spcific functions. The objective of this study was to examine the effects of degree of cell-cell contact (DCC) on liver sperific function of rat promary hepatocytes. Hepatocyte aggregates with various with various degrees of cell-cell contantact, I. e., dispersed cell, longish aggregate, rugged aggregate, and smooth spheroid were obtained at 1, 5-6, 15-20, and 36-48 hrs, respectively in suspension cultures grown in spinner flasks embedded in Caalginate bead and collagen gel in order. The may result from mass transfer limitation and shear damage caused by agitation during aggregation. The rugged aggregate showed a higer viability and albumin secretion rate than the dispersed cells or the other aggregates. This result indicates the possible enhancement of a bioartificial liver's (BAL) performance using primary hepatocytes and the reduction in time to prepare a BAL through optimization of the immobilization time.

  • PDF

Phenotype of Hepartocyte Spheroids in Synthetic Thermo-reversible Extracellular Matrix

  • Park, Keun--Hong;Park, Ju-Young;Bae, You-Han
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.4
    • /
    • pp.264-268
    • /
    • 2001
  • Aggregates of specific cells are often regarded as better from in artificial organs and mammalian cell bioreactors in terms of cell-specific functionality. In this study, the morphology and liver specific functions of freshly harvested primary rat hepatocytes, which were cultivated as spheroids and entrapped in a synthetic thermo-reversible extracellular matrix, were examined and compared to a control (hepatocytes in single cell form). A copolymer of N-isopropylacrylamide(98 mole % in feed) and acrylic acid (poly (NiPAAm-co-AAC)), a thermo- reversible copolymer gel ma- trix, was used to entrap hepatocytes either in spheroids or single cells. During a 7-day culture pe-riod, the spheroids maintained higher viability and produced albumin and urea at a relatively con-stant rate, while, the single cell culture showed a slight increase in cell numbers and a reduction in albumin secretion Hepatocytes cultrured as spheroids present a potentially useful three-dimensional cell culture system for application in bioartificial liver device.

  • PDF

Radial Flow Type Bioreactor for Bioartificial Liver Assist System using PTFE Non-Woven Fabric Coated with Poly-amino Acid Urethane Copolymer

  • Miskon, Azizi;Yamaoka, Tetsuji;Uyama, Hiroshi;Kodama, Makoto
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.259-259
    • /
    • 2006
  • PAU is the block copolymer consists of a small amount of a small amount of poly(${\gamma}-methyl-L-glutamate$) (PMLG) and the polyurethane. The urethane segments are hydrophobic and then strongly interact with the other hydrophobic materials such as PTFE, and the PMLG segments with the ${\alpha}-helix$ structure possess the cytocompatibility. Therefore, PAU can be easily coated onto the PTFE fiber and acts as an artificial extracellular matrix with the high cytocompatibility Results shows, the immobilization, cultured and functions of porcine hepatocytes is greatly improved.

  • PDF