• Title/Summary/Keyword: Binocular fusion

Search Result 18, Processing Time 0.024 seconds

The Effect of Accommodation Cue Manipulation at Stereoscopic Display on Binocular Fusion (양안식 디스플레이에 제시되는 자극의 조절단서 조작이 양안융합에 미치는 영향)

  • Park, Jong-Jin;Kim, Shinwoo;Li, Hyung-Chul O.
    • Journal of Broadcast Engineering
    • /
    • v.27 no.4
    • /
    • pp.569-580
    • /
    • 2022
  • In this study, we investigated the effect of peripheral blur on binocular fusion to resolve binocular fusion failure which is one of the 3D visual fatigues in the perspective of human visual system. With stimulus having discrete disparity change, binocular fusion failure rate for target stimulus having crossed and uncrossed disparity decreased. And target stimulus having continuous disparity also required relatively larger binocular disparity when peripheral blur was presented with target stimulus rather than when peripheral blur was not presented. These results imply that peripheral blur facilitated binocular fusion in the situation of binocular disparity change, and suggest that considering the characteristics of human three-dimensional visual systems, manipulating 3D contents can improve visual discomfort caused by binocular displays at low costs.

A Study on Comparision of the Quantity of Phoria as Way to Separation of Binocular Fusion (양안융합의 분리 시간에 따른 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.331-337
    • /
    • 2014
  • Purpose: This is a comparative experimental study on the amount of phoria by the removal time of binocular fusion. In this study, three tests were used for phoria test like Howell test, Thorington test and developed 3D polarizing test. Methods: In this study, it was considered the removal time of binocular fusion for measuring phoria. The three methods were used for measuring quantity of phoria: Howell test, Thorington test and developed 3D Polarizing test. The measurements progressed quickly to avoid eye-strain. So we designed the test charts for marking 3D display modules and the apparatus inserted lenses, like Maddox lens and prism, which are compatible with three phoria tests. The phoria at the moment separation was measured when the binocular fusion was broken through the apparatus and the that at the stable separation was measured when activity of the separated two images like indicated box and figure on horizontal axis stopped. Results: There were statistically significant difference between quantity of phoria at moment separation and that at stable separation. Amount of phoria at moment separation was relatively larger than amount of that at stable separation. In result in exophoria, the quantity of phoria at moment separation was higher than that at stable separation, and in phoria measured by developed 3D polarizing test, it shows the similar results at two condition. Conclusions: For exophoria, the amount of phoria at moment separation of binocular fusion was relatively larger than that at stable separation. The amount of difference between phoria values at moment separation and that at stable separation was alike among three phoria tests. Usually in working, there is no distinction between moment separation and stable separation. But there were definitely the difference between two ways to separate binocular fusion. Therefore, it is need for writing on prescription test name for measuring phoria and condition of separation of binocular fusion.

The effect of inter-pupilary distance and accommodative convergence on binocular fusion and fixational depth (동공간 거리와 조절성 수렴이 양안 융합과 응시 깊이에 미치는 효과)

  • 반지은;감기택;정찬섭;손정영
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.1
    • /
    • pp.17-28
    • /
    • 2003
  • In order to provide natural images with a specified depth through three-dimensional display system, the stereo images should be similar to those projected from real environment as much as possible. Even when two persons see an identical scene, the binocular Parallax between two images of an object varies as a function of one's inter-pupilary distance (IPD). In this study, we investigated whether individual differences, such as IPD and accommodative vergence, would affect the perception of three dimensional scene provided by stereo-images. Results showed that a person's IPD is correlated with the limit of screen and binocular parallax for single vision, and affects the perceived depth of an object on fixation. More specifically, with longer IPD the limit of screen and binocular parallax for single vision is decreased, and the perceived depth is reduced. These results suggest that the screen and binocular parallax of an object should be calibrated with regard to users IPD to provide natural stereo-images with a specified depth and to Prevent double vision.

  • PDF

Case Study of Vision Therapy in Binocular Dysfunction-Convergence Insufficiency (양안시이상-폭주부족 교정의 임상사례)

  • Park, Hyun-Ju;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.131-135
    • /
    • 2007
  • To investigate whether vision therapy (vision training) are an effective way to influence the near point of convergence, fusion range and asthenopic symptoms in convergence insufficiency. For one chosen patient who had convergence insufficiency, vision therapy (vision training) was prescribed for 4 weeks. 4 weeks later vision therapy (vision training) was quite effective in convergence insufficiency. That is, vision therapy (vision training) was an effective means of reducing symptoms, improving fusion range and decompensating exophoria in patient with convergence insufficiency.

  • PDF

3D-Stereogram Design using the Shadow Stereopsis Method (조명법을 이용한 3D-Stereogram 제작)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.39-42
    • /
    • 2000
  • It is formed of 3D image stereopsis by the left right retina image's fusion and can be made 3D-Stereogram because of occuring the depth perception of binocular disparity. We made the 3D-stereogram of the object of shape a ball and the eyes by taking a photograph of the light source's position angle contrast of the binocular disparity's field angle. We examined that 3D-stereogram was to be the stereopsis.

  • PDF

The Study on the Improvement of Function and Sensation Symptoms of Binocular Vision for Vision Training Methods (시기능 훈련방법에 의한 양안시 기능적.감각적 증상 개선 효과 연구)

  • Lee, Chang-Seon;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.185-193
    • /
    • 2010
  • Purpose: The purpose of this study was to investigated the effect of vision training methods on the visual function and sensation symptoms of patients with convergence insufficiency. Mehtods: The vision training observation group included 35 clients who had binocular vision disorders without opthalmic diseases or vertical phoria. They took the each vision training once a week for eight weeks and were investigated for the function and sensation symptoms changes of binocular vision. Results: According to the results, all vision training methods showed improvement of binocular vision function and sensation symptoms. For Worth 4 Dot test, Titmus test and red lenses observed the changes in fusion rate, all the training methods showed similar improvements. Conclusions: The study proved that vision training methods for patients with binocular vision was effective for the improvement of the phoria, function and sensation symptoms of these patients.

The Effect of Vision Training on Exophoria and Intermittent Extropia Using MYSTERY CIRCLE System (MYSTERY CIRCLE 시스템을 이용한 폭주부족형 사위 및 간헐성 사시 환자의 시기능 훈련 효과 연구)

  • Lee, Chang-Seon;Kim, Kun-Kyu;Jeon, Young-Ki;Kim, Kong-Ki;Choi, Chul-Hee;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effect of vision training using MYSTERY CIRCLE system on patients with exophoria and intermittent extropia. Mehtods: The vision training observation group consists of 26 clients who had exophoria (n=18) and intermittent extropia (n=8) without opthalmic diseases or vertical phoria. Our clients took each vision training once a week for eight weeks and were investigated for the symptoms changes of binocular vision. Results: According to the results, MISTERY CIRCLE vision training methods improved the binocular vision function and sensation symptoms. For Worth 4 Dot test, Titmus test and red lenses showed fusion rate changes. Conclusions: The study proved that MISTERY CIRCLE vision training system for patients with binocular vision was effective for the improvement of the binocular vision symptoms of these patients.

Comparison of Binocular Function and Surgical Outcomes of Tenacious Proximal Fusion and High Accommodative Convergence/Accommodation Ratio Types of Intermittent Exotropia

  • Park, Jun Woo;Lee, Soo Jung
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.483-487
    • /
    • 2018
  • Purpose: To compare the characteristics and surgical outcomes in patients with tenacious proximal fusion (TPF) and high accommodative convergence/accommodation ratio (AC/A) types of intermittent exotropia. Methods: This study retrospectively enrolled 40 patients with intermittent exotropia, 23 with TPF and 17 with high AC/A. Binocular function was evaluated by Worth's 4-dot test. Patients underwent lateral rectus recession, and surgical outcomes were compared. Surgical success was defined as less than ${\pm}10$ prism diopters (PD) at 12 months postoperatively. Results: The proportion of diplopia at near, evaluated by Worth's 4-dot test, was significantly higher in patients with high AC/A than in those with TPF (35.3% vs. 4.3%, p = 0.029). The mean preoperative angles of deviation in TPF and high AC/A types were $28.3{\pm}4.4$ and $28.8{\pm}4.5PD$ at distances, and $14.7{\pm}4.2$ and $15.1{\pm}4.1PD$ at near. Twelve months after surgery, the mean angles of deviation in TPF and high AC/A types were $2.9{\pm}9.8$ and $1.2{\pm}9.6PD$, respectively, at distance and $1.7{\pm}7.7$ and $-1.3{\pm}11.3PD$ at near. The surgical success rates were similar in the TPF and high AC/A types (74.0% vs. 64.7%). Five (21.7%) patients with TPF and 2 (11.8%) with high AC/A type experienced recurrence, with consecutive esotropia occurring in 1 (4.3%) patient with TPF and 4 (23.5%) patients with high AC/A. Conclusions: The proportion of diplopia at near was higher in patients with high AC/A type than in those with TPF intermittent exotropia. However, the surgical success rates were not significantly different between the types.

Multi-Image Stereo Method Using DEM Fusion Technique (DEM 융합 기법을 이용한 다중영상스테레오 방법)

  • Lim Sung-Min;Woo Dong-Min
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.4
    • /
    • pp.212-222
    • /
    • 2003
  • The ability to efficiently and robustly recover accurate 3D terrain models from sets of stereoscopic images is important to many civilian and military applications. A stereo matching has been an important tool for reconstructing three dimensional terrain. However, there exist many factors causing stereo matching error, such as occlusion, no feature or repetitive pattern in the correlation window, intensity variation, etc. Among them, occlusion can be only resolved by true multi-image stereo. In this paper, we present multi-image stereo method using DEM fusion as one of efficient and reliable true multi-image methods. Elevations generated by all pairs of images are combined by the fusion process which accepts an accurate elevation and rejects an outlier. We propose three fusion schemes: THD(Thresholding), BPS(Best Pair Selection) and MS(Median Selection). THD averages elevations after rejecting outliers by thresholding, while BPS selects the most reliable elevation. To determine the reliability of a elevation or detect the outlier, we employ the measure of self-consistency. The last scheme, MS, selects the median value of elevations. We test the effectiveness of the proposed methods with a quantitative analysis using simulated images. Experimental results indicate that all three fusion schemes showed much better improvement over the conventional binocular stereo in natural terrain of 29 Palms and urban site of Avenches.

Change of Fixation Disparity and Accommodation when the Fusion Contrast Varied (융합대비에 따른 주시시차와 조절의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: To study the change of fixation disparity and accommodation as fusion contrast is deteriorated. Methods: 16 subjects who had above 20/20 and stereopsis took part. Monocular and binocular refraction were done with Zeiss Polatest Classic whereas the critical angle for stereopsis was done with TNO. A computer programmed with Random-Dot stereogram and vernier test managed a precise change of the fusion contrast and exposure time. Results: The fixation disparity was influenced by reduction of fusion contrast and had tendancy to exophoria (p=0.0004), especially it is considerably higher when uncrossed disparity was shown to exophoric subjects. Although accommodation was not influenced by a change of fusion contrast (p=0.803), vernier acuity was influenced (p=0.0000). Conclusions: Exophoric trend arose as the fusion contrast was reduced, nevertheless there was no accommadative change.

  • PDF