• 제목/요약/키워드: Bileaflet mechanical valve

검색결과 31건 처리시간 0.03초

Edwards Duromedics 기계판막의 판엽 이탈 -1예 보고- (Leaflet Escape of Edwards Duromedics Mechanical Heart Valve -Report of 1 case-)

  • 김재현;나찬영;백만종;서홍주;김종환;오삼세
    • Journal of Chest Surgery
    • /
    • 제37권4호
    • /
    • pp.373-375
    • /
    • 2004
  • Edwards Duromedics 기계판막은 잦은 판엽 이탈로 인해 1988년 5월부터 판매가 중지된 판막으로 국내에서는 현재까지 2예의 판엽 이탈이 보고되었다. 본원에서는 Edwards Duromedics 기계판막을 이용하여 승모판치환술을 받은 환자에서 발생한 판엽 이탈을 경험하였기에 증례 보고하는 바이다

경식도 심초음파 검사를 이용한 판막대치술 환자의 평가 (Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제24권3호
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

기계식 인공심장판막(MHV)에서의 혈액유동과 판막운동의 상호작용 (Interaction of Blood Flow and Leaflet Behavior in a Bileaflet Mechanical Heart Valve)

  • 최청렬;김창녕;권영주
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권5호
    • /
    • pp.505-512
    • /
    • 2000
  • 기계식 인공심장판막을 통한 혈액의 유동과 이 유동에 관련된 판첨의 거동특성을 수치해석기법을 이용하여 연구하였다. 혈액은 맥동류, 층류, 비압축성 유동으로 가정하였으며 유체-고체의 상호작용을 고려하기 위하여 혈액의 유동방정식과 고체의 운동방정식이 동시에 계산되었다. 심실과 대동맥에서의 압력파형을 경계조건으로 사용하였다. 연구의 결과로서 혈액유동과 판첨의 거동이 예측되었으며, 판막을 통한 3개의 제트가 발견되었으며 vortex가 판첨의 끝단에서 발생하여 하부로 흘러가는 것이 관찰되었다. 판첨의 닫힘 거동은 열림 거동에 비하여 2배정도 빠르게 진행되었으며 sinus에서 2개의 큰 vortex가 관찰되었다. 유체-고체 상호작용을 고려하는 본 연구방법은 향후 판막의 연구와 개발에 매우 유용할 것으로 판단된다.

  • PDF

도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구- (Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves-)

  • 진성훈;서경필
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향 (The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves)

  • 이계한;서종천
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.297-303
    • /
    • 1998
  • 판막 후부의 공동부는 판막의 닫힘 거동과 판막 주위의 혈류 유동장을 변화시켜 인공 판막의 수력학적 성능에 영향을 미칠 수 있다. 계식 이엽 판막(SJMV), 폴리머 단엽 판막(MLPV), 폴리머 삼엽 판막(FTPV)을 판막 후부에 공동부가 있는 시험부와 공동부가 없는 직관형 시험부에 설치하여 모의 순환 장치에서 판막의 수력학적 성능을 평가하였다. 판막의 누수량은 공동부가 있는 시험부에서 약간 작았고, 수축기 평균 압력강하는 크게 나타났으나 통계적으로는 큰 차이가 없었다. 따라서 판막 후부의 공동부는 판막의 수력학적 성능에 큰 영향을 나타내지 않았다. 유량 파형의 해석 결과 판막 후부 공동부는 MLPV에서는 판막의 닫힘에 큰 영향을 주지 않았으나, SJMV에서는 판막의 닫힘이 일찍 시작하게 하였고 이 영향은 FTPV에서 더욱 크게 나타났다. FTPV는 공동부가 있는 시험부에서 역류 최대 유량이 감소하였으므로 판막 후두에 공동부는 판막의 급격한 닫힘에 의한 역류 제트의 발생을 감소시키리라 기대된다.

  • PDF

이엽성 기게 심장판막 환자에 대한 낮은 강도의 항응고제 요법의 결과에 대한 임상분석 (Low-intensity Oral Anticoagulation Versus High-intensity Oral Anticoagulation in Patients with Mechanical Bileaflet Prosthetic Heart Valves)

  • 정성철;김미정;송창민;김우식;신용철;김병열
    • Journal of Chest Surgery
    • /
    • 제41권4호
    • /
    • pp.430-438
    • /
    • 2008
  • 배경: 기계 심장판막 대치술 후 발생하는 혈전성 합병증을 방지하기 위해 항응고제 치료로써 와파린을 환자에게 투여한다. 이때 환자에 따른 적절한 와파린 용량을 결정하기 위한 지표로서 INR을 참고하는데 통상 대동맥판막은 $2.0{\sim}3.0$, 승모판막은 $2.5{\sim}3.5$가 참고치로서 받아들여지고 있다. 하지만 임상 경험상 대부분의 환자에서 이 수치로 유지하였을때 출혈성 합병증(비출혈, 혈뇨, 자궁출혈, 뇌출혈 등)이 빈번하게 발생하여 참고치보다 더 낮게 유지하는 경우가 많다. 이에 본원에서는 기계 심장판막 환자들을 후향적으로 조사하여 혈전성 합병증의 빈도가 낮은 적정한 INR을 알아보고자 한다. 대상 및 방법: 1984년 1월부터 2007년 2월까지 이엽성 기계 심장판막 대치술을 받고 생존한 311명의 환자를 대상으로 후향적으로 조사하였다. 대동맥판막치환 환자들(60명)은 INR $1.5{\sim}2.0$ (1군), $2.0{\sim}2.5$ (2군), 2.5 (3군) 이상의 세 군으로 나누고 승모판막치환(171명)이나 승모판막과 대동맥판막을 동시에 치환한 환자들(80명)은 INR $1.5{\sim}2.0$ (1군), $2.0{\sim}2.5$ (2군), $2.5{\sim}3.0$ (3군), 3.0 (4군) 이상의 네군으로 나누어 혈전성 합병증 발생률, 중요출혈성합병증 발생률을 조사하여 각각의 생존함수를 비교하였다. 결과: 대동맥 판막치환 환자 중 혈전성 합병증은 2명, 출혈성합병증은 4명이 발생하였고 세군의 혈전성 합병증의 생존함수의 차이는 관찰되지 않았고 출혈성 합병증의 생존곡선에서 1, 2군과 3군의 차이가 관찰되었다. 승모판막치환이나 승모판막과 대동맥판막을 동시에 치환한 환자들 중 혈전성 합병증은 13명, 출혈성 합병증은 15명이 발생하였고 네 군의 혈전성 합병증의 생존함수의 차이는 관찰되지 않았고 출혈성 합병증은 1, 2군과 3, 4군에서 차이를 보였다. 결론: 모든 판막에서 INR이 $1.5{\sim}2.5$ (1군과 2군)로 유지한 환자들이 그 이상으로 유지한 환자들보다 혈전성 합병증에서 차이를 보이지 않았고 출혈성 합병증에서 유의하게 감소하는 양상을 보여 이엽성 기계판막에서 적정한 INR은 $1.5{\sim}2.5$로 유지하는 것이 바람직하다고 판단된다.

St.Jude 기계판막을 이용한 인공심장판막 치환의 외과적 고찰 (Clinical Evaluation of St.Jude Medical Valve Replacement)

  • 진웅;나석주;조규도;김치경;조건현;왕영필;이선희;곽문섭;김세화;이홍균
    • Journal of Chest Surgery
    • /
    • 제27권4호
    • /
    • pp.272-280
    • /
    • 1994
  • Total 400 St.Jude Medical Bileaflet Valves were implanted in 336 pts from January 1983 to June 1993; 64 were aortic, 205 were mitral, 64 were double valve and 3 were tricuspid position. The follow up period extended from 6 months to 10 years[mean 24.3 months]. Male to female ratio was 1:1.7. There were total 27 deaths[cardiac related 20, cardiac non-related 7]. Overall mortality was 2.9%/pt-yr. There were 10 early deaths[3.0%] and 10 late cardiac related deaths [3.0%]. Prosthetic valve related complications occurred in 19 patients[5.7%] and among them, seven died; four died of thromboembolic events, two died of anticoagulants therapy related hemorrhagic complications and one died of bacterial endocarditis. NYHA class improved significantly especially in aortic valve replacement and double valve replacement. In AVR cases, the mean NYHA was 2.8 preoperatively and 1.3 postoperatively. And in DVR cases, 3.3 preoperatively and 2.2 postoperatively. The decision to employ a particular prosthesis was made according to the anticipated or known complications of the valve. The St.Jude Medical Valve retains all the hazards of other mechanical valves, most notably, thromboembolism. But the hemodynamic performance of St.Jude Medical Valve compared most favorably with other substitute valves in many reports. 0ur experience didn`t show any differences compared other authors in terms of valve related complication. So we concluded St. Jude Medical Valve can be primarily considered in the selection of artificial valve except in the patients when the usage of anticoagulant therapy is contraindicated.

  • PDF

ATS 인공 심장 판막의 단기 및 중기 임상성적 (Short and Intermediate Term Results of the ATS Heart Valve Replacement)

  • 임창영;문승철;양진영;구원모;김대식;이건;이헌재
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

St. Jude Medical 판을 이용한 심판막 치환술의 성적 (A 6 Year Experience with the St. Jude Medical Cardiac Valve Prosthesis)

  • 조광현
    • Journal of Chest Surgery
    • /
    • 제25권3호
    • /
    • pp.296-306
    • /
    • 1992
  • A 6 year experience with the bileaflet St. Jude Medical valve is reported. Between Feb. 1986 and Dec. 1992, 68 patients received 87 such valves[36 mitral, 13 aortic, and 19 double mitral-aortic valve replacements]. The results are summarized as follows 1. There were 35 male and 33 female patients ranging in age from 17 to 55 years the mean age of 35.3 $\pm$ 9.7 years. 2. The mean aortic clamp time[ACT] of the MVR, AVR and DVR groups were 91.5$\pm$16.4, 117.2$\pm$28.7 and 165.5$\pm$24.1 minutes. The mean total bypass time [TBT] of the MVR, AVR and DVR groups were 112.8$\pm$19.5, 134.7$\pm$31.4 and 192.2$\pm$28.5 minutes. 3. Eighty seven valves were used [55 mitral site, 32 aortic site]. 31mm[20], 33mm[15], 29mm[15], 27mm[2], 25mm[2] and 35mm[1] were used in mitral site and 23mm[13], 21mm[8], 19mm[7] and 25mm[4] were used in the aortic site. In the DVR, there were valve combinations such as 4 cases of M[29mm]-A[19mm], 4 of M[31mm]-A[23mm], 3 of M[33mm]-A[23mm] and others. 4. Preoperative NYHA functional classes were II [3 cases], III [46 cases], IV[19 cases] and improved to I [52 cases] and Il [13 cases] postoperatively. 5 Early postoperative complications were occurred in 15 cases[2Z.l%] and there were LOS in 5 cases[7.4%], arrythmia [3 cases], wound infection [2 cases], hepatitis [2 cases], sudden cardiac arrest [2 cases] and postoperative bleeding [1 case]. The early hospital death was occurred in 3 cases[4.4%] with LOS [1 case] and sudden cardiac arrest [2 cases]. 6. Mean follow-up time of survival cases[65 cases] was 31.3$\pm$21.9 months and the total follow-up time was 169.8 patient-years. Late postoperative complications were occurred in 4 cases[2 thromboembolism, 1 paravalvular leak, 1 thromboembolism br paravalvular leak, 1 valve endocarditis] with the occurrence rate as 2.35% per patient-years. Reoperation was performed in 2 cases [1 paravalvular leak, 1 left atrial thrombus] and there was one [1.5%] late valve related death. Therefore the 6 year complication free rate was 90.6% and 6 year actuarial survival rate was 98.3$\pm$1.7%. On the basis of this experience and the results, SJMvalve appears to be one of the best performing mechanical prosthesis currently available, in terms of both hemodynamics and lower complications with warfarin antioagulation.

  • PDF

On-X 기계판막을 이용한 판막치환술의 단기성적분석 (Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • 제37권9호
    • /
    • pp.742-748
    • /
    • 2004
  • On-X 판막은 비교적 최근 소개된 이엽성 기계판막으로 국립의료원에서 시행한 28명의 환자의 단기 임상성적을 통하여 판막의 안정성과 유용성을 보고하고자 한다. 대상 및 방법: 1999년 5월부터 2003년 5월까지 On-X 판막을 이용하여 32예의 판막치환술을 받은 28명의 연속적인 환자를 대상으로 하였으며 승모판막 치환 12예, 대동맥 판막치환 10예 그리고 승모판막 및 대동맥판막치환 6예이었다. 수술 후 발생한 합병증 및 사망률에 대한 정의 및 분류는 심장 판막수술에 대한 AATS/STS 지침에 근거하여 분석하였다. 전체 추적기간은 64환자-년이었고 평균 27개월이었다 결과: 수술 후 30일 이내의 조기 사망률은 7.14% (2/28)이었으며 만기사망은 없었다. 2년 생존율은 전체적으로 92.86$\pm$4.87% 이며 대동맥판막치환술이 90$\pm$9.49%, 이중판막치환술이 83.3$\pm$1.52%, 승모판막치환술이 100%로 나타났다. 혈전 색전증이 가장 많은 합병증으로 2예가 있었으며 모두 승모판막치환 증례에서 발생되어 Linearized Ratio는 총 3.17%/환자-년이었으며 승모판막만을 보면 6.5%/환자-년이었고 항응고제와 관련 된 출혈, 판막폐쇄증, 판막주위누출, 심내막염 등의 합병증의 모든 예에서 발생되지 않아 판막관련 합병증이 없는 2년간의 빈도는 84.85 $\pm$ 10.75% (freedom from valve related complication)이었다. 수술전 NYHA Class III 이상인 증례가 24예(85.71%)이었으나 수술 후에는 NYHA Class I 또는 II에 속하는 증례가 25예로 89.29%를 보였다. 용혈척도로서 혈색소 수치, 혈장 LDH, 망상적혈구수치, 간접 빌리루빈치는 수술 3개월 후 검사에서 모두 정상수치를 보였다. 수술 후 3개월 추적관찰 시 시행한 심초음파상 승모판막의 최대 압력차는 6.1 $\pm$ 1.8 mmHg, 평균 압력차는 3.0$\pm$0.6 mmHg이었고 유효 개구 면적은 판막 직경 27 mm, 29 mm, 31 mm, 33 mm 각각 2.54$\pm$0.56 $m^2$, 2.39 $\pm$0.73 $m^2$, 2.34 $\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$이었다. 대동맥판막의 최대 압력차는 21.1$\pm$14.12 mmHg,평균 압력차는 12.3$\pm$6.52 mmHg. 결론: On-X 판막수술 후 사망률, 판막관련합병증, 도플러 심초음파상 다른 판막들과 큰 차이를 보이지 않은 점과 NYHA Class의 호전과 정상수치를 유지하는 용혈지표를 고려한다면 비교적 좋은 결과를 보였으며 증례의 축적과 장기간의 임상분석이 이루어지면 안전하고 유용한 판막으로 입증될 것이라고 생각한다.