• Title/Summary/Keyword: Bileaflet mechanical valve

Search Result 31, Processing Time 0.036 seconds

Leaflet Escape of Edwards Duromedics Mechanical Heart Valve -Report of 1 case- (Edwards Duromedics 기계판막의 판엽 이탈 -1예 보고-)

  • 김재현;나찬영;백만종;서홍주;김종환;오삼세
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.373-375
    • /
    • 2004
  • Edwards Duromedics Valve has been suspended from the market since May 1988 due to the frequent reports of leaflet escape. There were 2 case-reports of leaflet escapes in this country. We report a case of leaflet escape in an Edwards Duromedics bileaflet valve, in the mitral position.

Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement (경식도 심초음파 검사를 이용한 판막대치술 환자의 평가)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

Interaction of Blood Flow and Leaflet Behavior in a Bileaflet Mechanical Heart Valve (기계식 인공심장판막(MHV)에서의 혈액유동과 판막운동의 상호작용)

  • 최청렬;김창녕;권영주
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.505-512
    • /
    • 2000
  • 기계식 인공심장판막을 통한 혈액의 유동과 이 유동에 관련된 판첨의 거동특성을 수치해석기법을 이용하여 연구하였다. 혈액은 맥동류, 층류, 비압축성 유동으로 가정하였으며 유체-고체의 상호작용을 고려하기 위하여 혈액의 유동방정식과 고체의 운동방정식이 동시에 계산되었다. 심실과 대동맥에서의 압력파형을 경계조건으로 사용하였다. 연구의 결과로서 혈액유동과 판첨의 거동이 예측되었으며, 판막을 통한 3개의 제트가 발견되었으며 vortex가 판첨의 끝단에서 발생하여 하부로 흘러가는 것이 관찰되었다. 판첨의 닫힘 거동은 열림 거동에 비하여 2배정도 빠르게 진행되었으며 sinus에서 2개의 큰 vortex가 관찰되었다. 유체-고체 상호작용을 고려하는 본 연구방법은 향후 판막의 연구와 개발에 매우 유용할 것으로 판단된다.

  • PDF

Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves- (도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구-)

  • Jin, Seong-Hun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF

Low-intensity Oral Anticoagulation Versus High-intensity Oral Anticoagulation in Patients with Mechanical Bileaflet Prosthetic Heart Valves (이엽성 기게 심장판막 환자에 대한 낮은 강도의 항응고제 요법의 결과에 대한 임상분석)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.430-438
    • /
    • 2008
  • Background: All the patients with mechanical valves require warfarin therapy in order to prevent them from developing thromboembolic complications. According to the ACC/AHA practice guidelines, after AVR with bileaflet mechanical prostheses in patients with no risk factors, warfarin is indicated to achieve an INR of 2.0 to 3.0. After MVR with any mechanical valve, warfarin is indicated to achieve an INR of 2.5 to 3.5. But in our clinical experience, bleeding complications (epistaxis, hematuria, uterine bleeding, intracerebral hemorrhage etc.) frequently developed in patients who maintained their INR within this value. So, we retrospectively reviewed the patients with bileaflet mechanical heart valve prosthesis and we determined the optimal anticoagulation value. Material and Method: From January 1984 to February 2007, 311 patients have been followed up at a national medical center. We classified the AVR patients (n=60) into three groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II and an INR from 2.5 to 3.0 in Group III. We classified the MVR (n=171) and DVR (n=80) patients into four groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II, an INR from 2.5 to 3.0 in Group III and an INR from 3.0 to 3.5 in Group III. We compared the groups for their thromboembolic and bleeding complications by means of the Kaplan Meier method. Result: In the AVR patients, 2 thromboembolic complications and 4 bleeding complications occurred and the log rank test failed to identify any statistical significance between the groups for thethromboembolic complication rate, but groups I and II had lower bleeding complication rates than did group III. Thirteen thromboembolic complication and 15 bleeding complication occurred in the MVR and DVR patients, and the log rank test also failed to identify statistical significance between the groups for the thromboembolic complication rate, but groups I and II had lower bleeding complication rates that did groups III and IV. Conclusion: The thromboembolic complication rate was not statistically different between groups I and II and groups III and IV, but the bleeding complication rates of groups I and II were lower than those of groups III and IV. So this outcome encouraged us to continue using our low intensive anticoagulation regime, that is, an INR of 1.5 to 2.5.

Clinical Evaluation of St.Jude Medical Valve Replacement (St.Jude 기계판막을 이용한 인공심장판막 치환의 외과적 고찰)

  • Jin, Ung;Rha, Suk-Joo;Cho, Kyu-Do;Kim, Chi-Kyung;Jo, Keon-Hyon;Wang, Young-Pil;Lee, Sun-Hee;Kwak, Moon-Sub;Kim, Se-Wha;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.27 no.4
    • /
    • pp.272-280
    • /
    • 1994
  • Total 400 St.Jude Medical Bileaflet Valves were implanted in 336 pts from January 1983 to June 1993; 64 were aortic, 205 were mitral, 64 were double valve and 3 were tricuspid position. The follow up period extended from 6 months to 10 years[mean 24.3 months]. Male to female ratio was 1:1.7. There were total 27 deaths[cardiac related 20, cardiac non-related 7]. Overall mortality was 2.9%/pt-yr. There were 10 early deaths[3.0%] and 10 late cardiac related deaths [3.0%]. Prosthetic valve related complications occurred in 19 patients[5.7%] and among them, seven died; four died of thromboembolic events, two died of anticoagulants therapy related hemorrhagic complications and one died of bacterial endocarditis. NYHA class improved significantly especially in aortic valve replacement and double valve replacement. In AVR cases, the mean NYHA was 2.8 preoperatively and 1.3 postoperatively. And in DVR cases, 3.3 preoperatively and 2.2 postoperatively. The decision to employ a particular prosthesis was made according to the anticipated or known complications of the valve. The St.Jude Medical Valve retains all the hazards of other mechanical valves, most notably, thromboembolism. But the hemodynamic performance of St.Jude Medical Valve compared most favorably with other substitute valves in many reports. 0ur experience didn`t show any differences compared other authors in terms of valve related complication. So we concluded St. Jude Medical Valve can be primarily considered in the selection of artificial valve except in the patients when the usage of anticoagulant therapy is contraindicated.

  • PDF

Short and Intermediate Term Results of the ATS Heart Valve Replacement (ATS 인공 심장 판막의 단기 및 중기 임상성적)

  • Lim, Chang-Young;Moon, Seung-Chul;Yang, Jin-Young;Koo, Won-Mo;Kim, Dae-Sig;Lee, Gun;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

A 6 Year Experience with the St. Jude Medical Cardiac Valve Prosthesis (St. Jude Medical 판을 이용한 심판막 치환술의 성적)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.296-306
    • /
    • 1992
  • A 6 year experience with the bileaflet St. Jude Medical valve is reported. Between Feb. 1986 and Dec. 1992, 68 patients received 87 such valves[36 mitral, 13 aortic, and 19 double mitral-aortic valve replacements]. The results are summarized as follows 1. There were 35 male and 33 female patients ranging in age from 17 to 55 years the mean age of 35.3 $\pm$ 9.7 years. 2. The mean aortic clamp time[ACT] of the MVR, AVR and DVR groups were 91.5$\pm$16.4, 117.2$\pm$28.7 and 165.5$\pm$24.1 minutes. The mean total bypass time [TBT] of the MVR, AVR and DVR groups were 112.8$\pm$19.5, 134.7$\pm$31.4 and 192.2$\pm$28.5 minutes. 3. Eighty seven valves were used [55 mitral site, 32 aortic site]. 31mm[20], 33mm[15], 29mm[15], 27mm[2], 25mm[2] and 35mm[1] were used in mitral site and 23mm[13], 21mm[8], 19mm[7] and 25mm[4] were used in the aortic site. In the DVR, there were valve combinations such as 4 cases of M[29mm]-A[19mm], 4 of M[31mm]-A[23mm], 3 of M[33mm]-A[23mm] and others. 4. Preoperative NYHA functional classes were II [3 cases], III [46 cases], IV[19 cases] and improved to I [52 cases] and Il [13 cases] postoperatively. 5 Early postoperative complications were occurred in 15 cases[2Z.l%] and there were LOS in 5 cases[7.4%], arrythmia [3 cases], wound infection [2 cases], hepatitis [2 cases], sudden cardiac arrest [2 cases] and postoperative bleeding [1 case]. The early hospital death was occurred in 3 cases[4.4%] with LOS [1 case] and sudden cardiac arrest [2 cases]. 6. Mean follow-up time of survival cases[65 cases] was 31.3$\pm$21.9 months and the total follow-up time was 169.8 patient-years. Late postoperative complications were occurred in 4 cases[2 thromboembolism, 1 paravalvular leak, 1 thromboembolism br paravalvular leak, 1 valve endocarditis] with the occurrence rate as 2.35% per patient-years. Reoperation was performed in 2 cases [1 paravalvular leak, 1 left atrial thrombus] and there was one [1.5%] late valve related death. Therefore the 6 year complication free rate was 90.6% and 6 year actuarial survival rate was 98.3$\pm$1.7%. On the basis of this experience and the results, SJMvalve appears to be one of the best performing mechanical prosthesis currently available, in terms of both hemodynamics and lower complications with warfarin antioagulation.

  • PDF

Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve (On-X 기계판막을 이용한 판막치환술의 단기성적분석)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.742-748
    • /
    • 2004
  • The On-X valve was recently introduced. It was the aim of this study to assess the safety and feasibility from the data derived from 28 patients who underwent aortic and/or mitral valve replacement with this prosthesis in National Medical Center. Material and Method: From May 1999 and May 2003, a series of 28 consecutive patients who had been implanted with 32 On-X prosthesis were reviewed, The operative procedure comprised of 12 MVR, 10 AVR and 6 DVR. The study followed the guidelines of AATS/STS. Mean follow-up was 27 months (total 04 patient-years). Result: Early ($\leq$30 days) mortality was 7.44% (2/28) and no late mortality occurred in the study. Total actuarial freedom from mortality at 2 years was 92.86$\pm$4.87% for all cases, 100% for MVR, 90$\pm$9.49% for AVR, and 83.3$\pm$1.52% for DVR. Thromboembolic event occurred in 2 MVR patients and that was the only complication; therefore, the linearized incidence of valve related complications was 3.17%/ patient-years for all cases and 6.5%/patient-years for MVR and the actuarial freedom from valve related complications at 2 years was 84.85$\pm$10.75%. Preoperatively, 24 (85.71%) patients were in NYHA functional class III or IV but postoperatively, 25 (89,29%) patients were in NYHA functional class I or II. The levels of hemoglobin, hematocrit, serum LDH, reticulocyte rate and indirect bilirubin were all within normal range at postoperative 3 month. In mitral position, the peak gradient was 6.1$\pm$1.8 mmHg and the mean gradient was 3.0$\pm$0.6 mmHg and EOA were 2.54$\pm$0.56 $m^2$, 2.39$\pm$0.73 $m^2$, 2.34$\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$ at 27 mm, 29 mm, 31 mm, 33 mm respectively. In aortic postion, the peak gradient was 21.1 $\pm$14.12 mmHg and the mean gradient was 12.3$\pm$6.52 mmHg. Conclusion: Since there was no significant difference in the postoperative mortality, valve related complications and echocardiographic hemodynamic data compared to standard bileaflet design and since there was an improvement in the NYHA functional class and normal values of hemolytic indicators, it can be assumed that On-X valve is safe and feasible. However, accumulation of cases and long-term follow-up of this patient group is needed to establish this result.