• Title/Summary/Keyword: Biceps

Search Result 650, Processing Time 0.026 seconds

The Comparison Effects between Electrical Stimulation Therapy and Isometric Exercise on Improvement of Biceps brachii Muscle Strength (EST와 등척성 운동이 상완이두근의 근력증진에 미치는 효과에 관한 비교연구)

  • Kim, Jeong-Seon;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • Purpose : To compare the effect between isometric exercise group(n=10) and electrical stimulation therapy group(n=10) on improvement of biceps brachii muscle strength. Methods : The experiments were performed for 4 weeks and three times a week. The participants of this study were 20 students(10 male, 10 female) who had not any medical problems. We divided into the two groups. One group received isometric exercise and the other group received EST for 4 weeks. The biceps brachii muscle strength was evaluated by making use of the KIN-COM. Results : The results were as follows 1. One group which received isometric exercise increased 36% for biceps brachii muscle strength. 2.The other group which received EST increased 54% for biceps brachii muscle strength. Conclusion : The results of this study showed that EST group was more effective than isometric exercise group.

  • PDF

A Case report on the Biceps Tendinitis Treatment with Fire needling Therapy (보존적 치료로 호전되는 않은 상완이두근 건염에 대한 화침을 포함한 한방 치료 1례)

  • Lim, Gwang-Mook;Kwon, Ho-Young;Kim, Jeong-Hwan
    • Korean Journal of Acupuncture
    • /
    • v.27 no.3
    • /
    • pp.143-150
    • /
    • 2010
  • Objective : The purpose of this study is to evaluate the effect of the fire needling therapy treatment on the biceps tendinitis. Methods : Fire needling therapy was administered five times to the patient complaining with biceps tendinitis. The improvement of clinical symptom was evaluated by McGill Pain Questionnaire -Short Form(SF-MPQ), Visual Analogue Scale(VAS) and Shoulder Pain, and Disability Index (SPADI). Result : After fire needling therapy to the biceps tendinitis patient five times, the patient's SF-MPQ score, VAS, and SPADI improved from 24 to 11, from 9 to 4, and from 33.6 to 14.8 respectively. Conclusions : Fire needling for biceps tendinitis should be tested in future randomized clinical trials.

Minimally invasive distal biceps tendon repair: a case series

  • Paul Jarrett;Anna-Lisa Baker
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.222-230
    • /
    • 2023
  • Background: Distal biceps tendon repairs are commonly performed using open techniques. A minimally invasive distal biceps tendon repair technique using a speculum and hooded endoscope was developed to improve visualization, reduce soft-tissue dissection, and minimize complications. This paper describes the technique and reports the outcomes of 75 minimally invasive distal biceps tendon repairs. Methods: The operation reports and outcomes of 75 patients who underwent distal biceps tendon repair using this technique between 2011 and 2021 were retrospectively reviewed. Results: Median time to follow-up was 12 months (interquartile range [IQR], 6-56 months). Primary outcomes were function as measured by the Disabilities of Arm, Shoulder and Hand Score (DASH) questionnaire, and rate of complications. Median DASH score was 1.7 of 100 (IQR, 0-6.8). There were 2 of 75 (2.7%) re-ruptures of the distal tendon. There were no cases of vascular injury, proximal radius fracture, or posterior interosseous nerve, median, or ulnar nerve palsy. Conclusions: In this series, minimally invasive distal biceps repair was safe and effective with a low rate of major complications. Recovery of function, as indicated by low DASH scores, was satisfactory, and inconvenience during recovery was minimized. Level of evidence: IV.

A Case Series of Symptomatic Distal Biceps Tendinopathy

  • Lee, Jung Hyun;Kim, Kyung Chul;Lee, Ji-Ho;Ahn, Kee Baek;Rhyou, In Hyeok
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.213-219
    • /
    • 2018
  • Background: The study of conservative and surgical treatment of distal biceps tendinopathy and associated biceps tendon partial rupture. Methods: Twenty-one cases with distal biceps tendonitis and partial ruptures were studied who visited Pohang Semyeong Christianity Hospital from June 2010 to August 2017. The mean age was 57.1 years (39-69 years), 14 males and 7 females. The mean duration of symptom at the time of first visit was 4.9 months (0.2-14 months). Ultrasonography and magnetic resonance imaging were performed for patients with severe symptoms. According to the severity of the symptoms, splint immobilization, oral nonsteroidal anti-inflammatory drugs, and ultrasound-guided steroid injection were performed. Surgical treatment was performed if the patient did not respond to conservative treatment for 3 to 6 months or longer. Results: There were 9 cases of partial rupture of the distal biceps tendon associated with distal biceps tendinopathy on imaging studies. Conservative treatment showed symptomatic improvement in 16 of 21 cases. In 4 cases with a relatively mild symptom, anti-inflammatory analgesics and intermittent splinting showed good result. In 12 cases, symptoms improved after ultrasonography-guided steroid injection. Surgical treatment was performed on 5 cases that did not respond to conservative treatment. Conclusions: Conservative treatment of distal biceps tendinopathy may promise good results. However, in case of partial tear of the distal biceps tendon and refractory to conservative treatment, surgical treatment may be needed.

Analysis of Onset Time of Muscle Contractions of the Biceps Brachii in Supination According to the Presence or Absence of Elbow Flexor Activity (팔꿉관절 굽힘 작용 배제 유무에 따른 뒤침 동작시 위팔두갈래근의 근수축 개시시간 분석)

  • Jeong-Wook Kim;Sang-Jae Moon;Min-Chull Park
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.47-52
    • /
    • 2023
  • Purpose: This study aims to examine the functional difference in the long and short heads of the biceps brachii by investigating the onset time of muscle contractions in the biceps brachii in the supination motion according to whether the flexor of the elbow joint is excluded. Methods: This study was conducted with 21 healthy men aged in their 20s. While performing forearm pronation at an elbow flexion angle of 90 degrees, the onset time of muscle contractions in the long and short heads of the biceps brachii was measured and compared in a posture where the humerus is placed on a table and the posture is lifted against gravity. Using an independent samples t-test, the difference in the onset time of muscle contractions in the long and short heads of the biceps brachii was analyzed. Results: The onset time of the long head was shorter if the flexor activity of the elbow joint was excluded, while that of the short head of the biceps brachii was shorter if it was not excluded. Conclusion: It is noted that the long head of the biceps brachii mainly functions as a supinator muscle, while the short head of the biceps brachii plays a role in stabilizing and maintaining flexion of the elbow joint.

Effect of Functional Pressure Garments on EMG Response of the Agonist during the Resistance Exercise of the Wrist and Elbow Joint

  • Kim, Ki Hong;Kim, Byung Kwan;Jeong, Hwan Jong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.81-89
    • /
    • 2020
  • The purpose of this study is to investigation the effects of functional compression clothing on muscle function by comparing the iEMG response of muscle during exercise according to the wearing of taping applied functional clothing. Six men in their twenties in Chungcheongnam-do were selected for the study. Resistance exercise was performed by cross-distributing the conditions of wearing and not wearing functional clothing. Resistance exercises for iEMG measurements are biceps curl, wrist curl, reverse wrist curl, kickback and push-up. iEMG measurement muscles were the biceps brachii, triceps brachii, extensor carpi ulnaris, flexor carpi radialis. During biceps curl exercise, the iEMG of triceps brachii, biceps brachii wearing condition was lower than the non-wearing condition. During kickback exercise, the iEMG of triceps brachii, extensor carpi ulnaris wearing condition was lower than the non-wearing condition. During reverse wrist curl exercise, the iEMG of extensor carpi ulnaris wearing condition was lower than the non-wearing condition. During wrist curl exercise, the iEMG of flexsor biceps brachii, carpi radialis wearing condition was lower than the non-wearing condition. During push-up exercise, the iEMG of triceps flexsor biceps brachii, carpi radialis, brachii, biceps brachii non-wearing condition was lower than the wearing condition.

Biceps Pulley Impingement - Case Report - (이두박건 활차의 충돌 징후 - 증례보고 -)

  • Choi Chang-Hyuk;Kim Shin-Kun;Kang Byung-Kyu;Jang Woo-Chang
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.71-76
    • /
    • 2003
  • We evaluated biceps pulley as a stabilizing sling for the long head of biceps tendon in the rotator interval. We present 3 cases of detached biceps pulley which impinges on posterosuperior glenoid labrum in the position of late cocking. Pulley impingement related to anterior shoulder instability was relieved after Bankart repair. In another two cases, impingement symptoms were disappeared after resection of the detached biceps pulley.

  • PDF

Intra-Rater and Inter-Rater Reliability of the Myotonometer in the Assessment of Biceps Brachii and Quadriceps (근긴장도검사기(Myotonometer)를 이용한 상완이두근과 대퇴사두근 검사의 신뢰도 연구)

  • Kim, Suhn-Yeop
    • Physical Therapy Korea
    • /
    • v.14 no.2
    • /
    • pp.29-36
    • /
    • 2007
  • Muscle tone (stiffness/hardness) or muscle compliance changes during muscle contraction. The purposes of this study were to assess the intrarater and interrater reliabilities of the Myotonometer$^{(R)}$, electronic device that quantifies muscle tone. Two raters used the Myotonometer to assess the right bicep brachia and quadriceps muscles of 30 voluntary persons without any orthopedic or neurological problems (age range, 18~21 yrs). Muscles were measured in a relaxed state and during brief sustained voluntary maximal isometric contraction. Intrarater correlation coefficients were calculated for each muscle and for each condition (relaxed and contracted). Intrarater reliabilities (intraclass correlation coefficients, ICCs) ranged from .778 to .954, relaxed, biceps brachia), .926 to .963 (contracted, biceps brachia), .935 to .990 (relaxed, quadriceps) and .679 to .952(contracted, quadriceps). Interrater reliabilities ranged from .652 to .790 (relaxed, biceps brachii), .813 to .907 (contracted, biceps brachii), .831 to .950 (relaxed, quadriceps) and .849 to .937 (contracted, quadriceps). Myotonometer measurements had high to very high intrarater and interrater reliability for measurements of the biceps brachia and quadriceps muscles.

  • PDF

Associated Changes During Arthroscopic Evaluation of the Glenohumeral Joint in Rotator Cuff Tear - Comparison According to Tear Size - (회전근 개 파열의 관절경적 치료 시 관절된 관절와 상완관절의 동반 변화 -파열의 정도에 따른 차이-)

  • Choi Chang-Hyuk;Kwun Koing-Woo;Kim Shin-Kun;Lee Sang-Wook;Cho Myung-Rae;Ko Sang-Bong;Kim Tae-Hoon
    • Clinics in Shoulder and Elbow
    • /
    • v.7 no.1
    • /
    • pp.5-9
    • /
    • 2004
  • Purpose: To identify associated findings in glenohumeral joint in rotator cuff tear and evaluate its clinical significance, we examined minor and major changes during arthroscopic or mini open repair. Materials & Methods: We reviewed 66 patients of rotator cuff tear treated from March, 2001 to January, 2004. Of 38 cases of small to medium tear, average age was 53 years old and involved in dominant arm in 27 cases. Of 28 cases of large to massive tear, average age was 58 years old and involved in dominant arm in 26 cases. Minor and major associated changes of the glenohumeral joint were evaluated in the tendon of biceps long head, biceps pulley, cartilage of the glenoid and humeral head, labrum and synovium. Results: Minor changes in biceps tendon were in 35% of cases, biceps pulley in 18%, cartilage of humeral head in 27%, cartilage of glenoid in 18%, labrum in 38%, and synovium in 42%. Major changes in biceps tendon were in 6% of cases, biceps pulley in 35%, arthritis of humeral head in 3%, arthritis of glenoid in 2%, labrum in 6%, and synovium in 21 %. Major changes in biceps tendon were 5% in Group I and 7% in Group Ⅱ(p>0.05) and in biceps pulley, 18% and 57% in each (P<0.05). Minor changes of arthritis were prevalent in glenoid cartilage and major changes were more prevalent in humeral head. There were no differences in minor changes of labrum and synovium, but major changes were more prevalent in Group Ⅱ. Conclusion: The prevalence of intraarticular associated changes of rotator cuff tear were 63% in synovium, 54% in labrum, 53% in biceps pulley, 41% in biceps tendon, 30% in humeral head and 20% in glenoid cartilage in order. Major changes of biceps pulley, humeral head, labrum and synovium were more prevalent in Group Ⅱ.