• Title/Summary/Keyword: Bent Microstrip Patch Antenna

Search Result 2, Processing Time 0.017 seconds

Band Type Wearable Device's RF Configuration and Bent Microstrip Patch Antenna (밴드형 Wearable Device의 RF Configuration과 Bent 마이크로스트립 패치 안테나)

  • Lee, Dongho;Choi, Woo Cheol;Kim, Sung Hoe;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.16-23
    • /
    • 2015
  • In this paper, a bent microstrip patch antenna, which is suitable for band-type wearable devices and RF configuration, to be used in the WCDMA2100 mobile network is proposed. The proposed antenna using RF configuration which is consisted of separated Tx and Rx frequency band is designed to operate or function in WCDMA2100 Tx frequency band only and it is not strongly affected by the human body because of the conductor at the bottom side. At both flat case and bent case, the proposed antenna's maximum gain satisfies at least 5.3 dBi, and its -6 dB return loss bandwidth is wider than 20 MHz. The simulated surface absorption rate($SAR_{1g}$) result is under 0.7 [W/kg]. The proposed antenna suits in band-type wearable devices which is worn on wrists or arms.

Design of Bent-Slotted High-Sensitivity Microstrip Patch Permittivity Sensor Antenna (구부러진 슬롯이 추가된 고감도 마이크로스트립 패치 유전율 센서 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.415-423
    • /
    • 2019
  • In this paper, a design method for a high-sensitivity microstrip patch sensor antenna (MPSA) loaded with a bent-slot was studied for the permittivity measurement. The bent-slot similar to a single-ring complementary split ring resonator was added along a radiating edge of the patch in order to enhance the sensitivity to the permittivity. The sensitivity of the proposed MPSA was compared with that of a conventional rectangular MPSA and a thin rectangular-slotted MPSA. Three MPSAs were designed and fabricated on a 0.76-mm-thick RF-35 substrate so that the input reflection coefficient would resonate at 2.5 GHz in the absence of the superstrate under test. When five different Taconic substrates with a relative permittivity ranging from 2.17 to 10.2 were used as the superstrate under test, experiment results show that the sensitivity of the proposed MPSA, which is measured by the shift in the resonant frequency of the input reflection coefficient, is 4.1 to 6.1 times higher than that of the conventional MPSA.