• Title/Summary/Keyword: Beats

Search Result 223, Processing Time 0.024 seconds

Changes of Heart Rate During Marathon Running (장거리 (마라톤)선수에서의 전 경기중 심박동수의 변화)

  • Kim, In-Kyo;Lee, Jung-Woo;Hah, Jong-Sik;Ryu, Yun-Hee;Choi, Jung-Ok;Kim, Ki-Ho
    • The Korean Journal of Physiology
    • /
    • v.13 no.1_2
    • /
    • pp.1-12
    • /
    • 1979
  • To evaluate the present status of physical fittness of Korean long distance runners, body fat, pulmonary functions, maximal oxygen intake and oxygen debt were measured in 5 elite marathoners (A group), 6 college student runners (B group) and 3 middle school student runners (C group). After laboratory tests, full course marathon running was performed in 2 elite marathoners during which their heart rates were monitored continuously. The results are summerized as follows: 1) Total body fat in all three groups are in the range of 13-15% of their body weight. 2) In all three groups, average values of various pulmonary functions were within the normal limits, but those of tidal volume were higher and respiratory rate were lower in comparison to normal values. These phenomena may represent respiratory adaptations against training. The average resting oxygen consumptions in A,B and C were $322{\pm}23$, $278{\pm}14$ and $287{\pm}16$m1/min, respectively. 3) In all three groups, resting blood pressures were in the normal range, but the resting heart rate was slightly lower in groups A $(56{\pm}3\;beats/min)$ and B $(64{\pm}2\;beats/min)$ and higher in group C $(82{\pm}9\;beats/min)$ in comparison to normal values. These changes in cardiovascular functions in marathoners may also represent adaptive phenomena. 4) During treadmill running the minute ventilation and oxygen consumption of the runners increased lineally with work load in all three groups. When the oxygen consumption was related to heart rate, it appeared to be a exponential function of the heart rate in all three groups. 5) The average maximal heart rates during maximal work were $196{\pm}3$, $191{\pm}3$ and $196{\pm}5\;beats/min$ for groups A,B and C, respectively. Maximal oxygen intakes were $84.2{\pm}3.3\;ml/min/kg$ in group A, $65.2{\pm}1.1\;ml/min/kg$ in group B and $58.7{\pm}0.4\;ml/min/kg$ in group C. 6) In all three groups, oxygen debts and the rates of recovery of heart rate after treadmill running were lower than those of long ditsance runners reported previously. 7) The 40 km running time in 2 elite marathoners was recorded to be $2^{\circ}42'25'$, and their mean speed was 243 m/min (ranged 218 to 274 m/min). The heart rate appeared to increase lineally with running speed, and the total energy expenditure during 40 km running was approximately 1360.2 Calories. From these it can be speculated that if their heart rates were maintained at 166 beats/min during the full course of marathon running, their records would be arround $2^{\circ}15'$. Based on these results, we may suspect that a successful long distance running is, in part, dependent on the economical utilization of one's aerobic capacity.

  • PDF

Affecting Factors on Left Ventricle Ejection Fraction Measured using 64-slice MDCT (64 절편 MDCT를 이용한 심장CT에서 측정된 좌심실 구혈률에 영향을 미치는 요인)

  • Kang, Yeong-Han;Kim, Kyung-Wook;Cho, Kwang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.250-257
    • /
    • 2010
  • This study was to analysis what factors could affect left ventricle ejection fraction(LVEF) using 64-slice multidetector CT. 164 patients(84 men, 80 women) had a cardiac CT in this study, and their blood pressure, body mass index(BMI), heart rate(HR) measured. LVEF was 52.00${\pm}$18.95% in below 25kg/$m^2$, 59.50${\pm}$16.05% in above 25kg/$m^2$ of BMI. LVEF was 57.26${\pm}$17.84% in normal blood pressure group(NBPG), 49.95${\pm}$17.63 in hypertension group(HG). LVEF was 60.76${\pm}$17.26 in below 60 beats/min, 54.14${\pm}$16.56 in 60-70 beats/min, 50.83${\pm}$20.56 in above 70 beats/min of HR. LVEF was negatively correlated with age, HR(r=-0.283 p<0.05, r=-0.231 p<0.05. respectively). And LVEF was positively correlated with BMI(r=0.228 p<0.05). A measurement of LVEF at cardiac CT by using MDCT may be considered to age, blood pressure, heart rate and BMI.

Effects of Soaansintang(SOAT) on the hemodynamics and electrocardiogram of isolated rat hearts induced by electrical stimulation (소아안신탕(小兒安神湯)이 STRESS를 유발한 흰쥐의 적출심장(摘出心臟)에 미치는 영향)

  • Lee Seung-Jun;Lee Jin-Yong;Kim Deok-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-32
    • /
    • 2000
  • It has long been known that SOAT is effective for sudden palpitation occurring unexpectedly in Oriental Medicine. However, effect of SOAT on the isolated heart has not been studied yet. The purpose of this study is to investigate the effect of SOAT on hemodynamics and ECG of isolated rat hearts induced by electrical stimulation using Langendorff perfusion apparatus for nonworking heart. SOAT extract was manufactured by water-alcohol precipitated method. Sprague-Dawley rats weighting $120{\sim}150g$ were used for the experiments, Subject animals were divided into four groups, which are consisted of 1) control(Group orally administered by normal saline 1ml for 14days), 2) sample A(Group orally administered by SOAT extract 1ml for 14days), 3) sample C(Group injected by SOAT extract 0.5ml after stimulation, 4) sample C(Group injected by SOAT extract 1ml after stimulation. To evluate the effects of SOAT on hemodynamics and ECG of isolated rat heart induced by stimulation, heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume and ECG were measured using Langendorff apparatus in both stimulation mode(5 volts, 450 beats/min) and arrythmic mode(5 volts, 420 beats/min including 60 beats/min) The results obtained are as follows : 1. After receiving stressful electrical stimuli, isolated heart showed the heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume were all decreased temporarily, but perfusion continued longer recovery to the control state appeared. However, the coronary artery perfusion volume diminished continuously. 2. The heart rates did not change significantly with both stimulation mode and arrhythmic mode, among experimental groups. 3. The left ventricular pressure showed with both stimulation mode and arrhythmic mode, the significant changes(p<0.05) especially in the injection sample group. In case of stimulation mode, low concentration injection group(0.5ml) was more significantly increased rather than high concentration group(1ml) and in case of arrhythmic mode, high density group(1ml) was so increased than the other(0.5ml). 4. For the systolic power and diastolic power, no significant changes were noticed in the stimulation mode, but in the arrhythmic mode of injection sample groups, significant change(p<0.05) was noticed in both systolic power and diastolic power. Specially the high concentration group(1ml) showed more significant increase than the low concentration group. 5. For the coronary artery perfusion volume, no significant change difference among sample groups was observed in both the stimulation mode and the arrhythmic mode. 6. For the ECG recordings, arrhythmia was induced by electrical stimulus of arrythmia mode and after the stimulus was removed, irregular wave appeared temporarily, but as perpusion continued, recovery to the control state was abtained like the stimulation mode. According to the above results, SOAT significantly changed the hemodynamic data from the electrically stressed, isolated hearts of connected Langendorff perfusion apparatus and we propose SOAT has the direct effects on the muscular function of heart.

  • PDF

Predictive Factors of Blood Transfusion Requirement in Blunt Trauma Patients Admitted to the Emergency Room (응급실에 내원한 둔상환자의 수혈 필요성 예측인자)

  • Oh, Ji Sun;Kim, Hyung Min;Choi, Se Min;Choi, Kyoung Ho;Hong, Tae Yong;Park, Kyu Nam;So, Byung Hak
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.218-226
    • /
    • 2009
  • Purpose: In multiple blunt trauma patients, transfusion may be a significant therapeutic adjunct to non-operative management. The blood products must be expedited and efficiently to patients in impending shock caused by hemorrhage or traumatic coagulopathy, but the decision to perform blood transfusion has been made empirically, based on the clinician' and has not been guided by objective parameters, but own opinion, that may result in an underestimate of or a failure to detect bleeding, in delayed transfusion, and in a reduced outcome. This article presents quickly assessable predictive factors for determining if a blood transfusion is required to improve outcomes in multiple blunt trauma patients admitted to the emergency room. Methods: In a retrospective review of 282 multiple blunt trauma patients who visited our emergency center by emergency rescuer during a 1-year period, possible factors predictive of the need for a blood transfusion were subjected to univariate and multivariate logistic regression analysis. Results: Of blunt trauma patients, 9.2% (26/282), received red blood cells in the first 24 hours of care. Univariate analysis revealed significant associations between blood transfused and heart rate (HR) > 100 beats/min, respiratory rate (RR) > 20 breaths/min, Glasgow Coma Scale (GCS) < 14, Revised Trauma Score (RTS) < 11, white blood cell count (WBC) < 4000 or > 10000, and initial abnormal portable trauma series (Cspine lateral, chest AP, pelvis AP). A multiple regression analysis, with a correction for diagnosis, identified HR > 100 beats/min (EXP 3.2), GCS < 14 (EXP 4.1), and abnormal trauma series (EXP 2.9), as independent predictors. Conclusion: In our study, systolic blood pressure (SBP) < 90 mmHg, old age > 65 years, hemoglobin < 13g/dL, mechanism of injury were poor predictors of early blood transfusion. Initial abnormal portable trauma series, HR > 100 beats/min, and GCS < 14 were quickly assessable useful factors for predicting a need for early blood transfusion in blunt trauma patients visiting the emergency room.

The Effect of Various Hot Environments on Physiological Responses and Information Processing Performance Following Firefighting Activities in a Smoke-Diving Room

  • Hemmatjo, Rasoul;Motamedzade, Majid;Aliabadi, Mohsen;Kalatpour, Omid;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.386-392
    • /
    • 2017
  • Background: Fire service workers often implement multiple duties in the emergency conditions, with such duties being mostly conducted in various ambient temperatures. Methods: The aim of the current study was to assess the firefighters' physiological responses, information processing, and working memory prior to and following simulated firefighting activities in three different hot environments. Seventeen healthy male firefighters performed simulated firefighting tasks in three separate conditions, namely (1) low heat (LH; $29-31^{\circ}C$, 55-60% relative humidity), (2) moderate heat (MH; $32-34^{\circ}C$, 55-60% relative humidity), and (3) severe heat (SH; $35-37^{\circ}C$, 55-60% relative humidity). It took about 45-50 minutes for each firefighter to finish all defined firefighting activities and the paced auditory serial addition test (PASAT). Results: At the end of all the three experimental conditions, heart rate (HR) and tympanic temperature (TT) increased, while PASAT scores as a measure of information processing performance decreased relative to baseline. HR and TT were significantly higher at the end of the experiment in the SH ($159.41{\pm}4.25beats/min$; $38.22{\pm}0.10^{\circ}C$) compared with the MH ($156.59{\pm}3.77beats/min$; $38.20{\pm}0.10^{\circ}C$) and LH ($154.24{\pm}4.67beats/min$; $38.17{\pm}0.10^{\circ}C$) conditions (p < 0.05). There was no significant difference in PASAT scores between LH and MH (p > 0.05). Nonetheless, there was a measurable difference in PASAT scores between LH and SH (p < 0.05). Conclusion: These consequences demonstrate that ambient temperature is effective in raising the physiological responses following firefighting activities. It is therefore argued that further increase of ambient temperature can impact firefighters' information processing and working memory during firefighting activity.

Rhythmization of Sprung Rhythm by a Sub-beat (하위박에 의한 도약율의 리듬화)

  • Sohn Il-Kwon
    • MALSORI
    • /
    • no.39
    • /
    • pp.25-42
    • /
    • 2000
  • In this paper, I have shown how to associate a musical beat with a note within the framework of Optimality Theory. And the following hierarchy of constraints is suggested to associate a sub-beat with a note. Alternation Sub-beat CCC Head $\gg$ Beat-to-Note $\gg$ Note-to-Beat EQ-Beats Smaller Note Furthermore, I have tried to explain Sprung Rhythm with a musical beat system. I have suggested the following hierarchy for Sprung Rhythm. Head $\gg$ SCSR Using a sub-beat on the basis of Head $\gg$ SCSR shows the abrupt change of Sprung Rhythm well.

  • PDF

A STUDY ON RELATIVE EFFICIENCY OF KERNEL TYPE ESTIMATORS OF SMOOTH DISTRIBUTION FUNCTIONS

  • Jee, Eun-Sook
    • The Pure and Applied Mathematics
    • /
    • v.1 no.1
    • /
    • pp.19-24
    • /
    • 1994
  • Let P be a probability measure on the real line with Lebesque-density f. The usual estimator of the distribution function (≡df) of P for the sample $\chi$$_1$,…, $\chi$$\_$n/ is the empirical df: F$\_$n/(t)=(equation omitted). But this estimator does not take into account the smoothness of F, that is, the existence of a density f. Therefore, one should expect that an estimator which is better adapted to this situation beats the empirical df with respect to a reasonable measure of performance.(omitted)

  • PDF

Analysis on the Characteristics of the group-bounded long wave (파군에 따른 장주기파의 거동특성 해석)

  • 이철응;이길성;편종근
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1993.07a
    • /
    • pp.130-136
    • /
    • 1993
  • 단주기파군에 의하여 발생되는 장주기파를 나타내는 용어로 surf-beats, edge파 그리고 평균수위강하(set-down 또는 group bounded long wave)등이 사용되어지고 있다. 이들의 발생성격에 대한 물리적 특성으로, surf-beats와 edge파는 일반적으로 천해역에서 발생하는 비선형간섭(쇄파특성) 및 해안선의 반사성과 관련있으며 평균수위강하는 단지 단주기파에 의하여 형성된 파군의 특성과 관련을 갖게 된다. (중략)

  • PDF

Studies on the Transmission Performance of Opencable and CVB-C (Opencable 방식과 DVB-C 방식의 전송성능에 관한 연구)

  • Lee, Jae-Ryun;Sohn, Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.2C
    • /
    • pp.184-190
    • /
    • 2002
  • This paper compares and analyzes and analyzes the transmission performance of the OpenCable system and the DBD-C system which are adopted as the digital CATV transmission standard in U.S.A. and Europe respectively through computer simulation under the same channel environment. We considered the channel environment including the random noise and the CTB (Composite Tripple Beats) noise as channel impairments in order to compare the two standard fairly. Additionally, we analyzed the transmission performance of the OpenCable system for the various interleaving depths. We implemented each transmission system by software, and we analyzed BER values with respect to the C/N in order to compare their transmission performance. As a result of the computer simulation, to get the BER of ${10}^{-6}$ the OpenCable system requires 1.2 dB kiwer C/N than the DVB-C system in the 64-QAM mode, and the two system require similar C/N in the 256-QAM mode.

Detection of Abnormal Heartbeat using Hierarchical Qassification in ECG (계층구조적 분류모델을 이용한 심전도에서의 비정상 비트 검출)

  • Lee, Do-Hoon;Cho, Baek-Hwan;Park, Kwan-Soo;Song, Soo-Hwa;Lee, Jong-Shill;Chee, Young-Joon;Kim, In-Young;Kim, Sun-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.466-476
    • /
    • 2008
  • The more people use ambulatory electrocardiogram(ECG) for arrhythmia detection, the more researchers report the automatic classification algorithms. Most of the previous studies don't consider the un-balanced data distribution. Even in patients, there are much more normal beats than abnormal beats among the data from 24 hours. To solve this problem, the hierarchical classification using 21 features was adopted for arrhythmia abnormal beat detection. The features include R-R intervals and data to describe the morphology of the wave. To validate the algorithm, 44 non-pacemaker recordings from physionet were used. The hierarchical classification model with 2 stages on domain knowledge was constructed. Using our suggested method, we could improve the performance in abnormal beat classification from the conventional multi-class classification method. In conclusion, the domain knowledge based hierarchical classification is useful to the ECG beat classification with unbalanced data distribution.