• 제목/요약/키워드: Beat signal

검색결과 137건 처리시간 0.022초

Improved Dynamic Programming in Local Linear Approximation Based on a Template in a Lightweight ECG Signal-Processing Edge Device

  • Lee, Seungmin;Park, Daejin
    • Journal of Information Processing Systems
    • /
    • 제18권1호
    • /
    • pp.97-114
    • /
    • 2022
  • Interest is increasing in electrocardiogram (ECG) signal analysis for embedded devices, creating the need to develop an algorithm suitable for a low-power, low-memory embedded device. Linear approximation of the ECG signal facilitates the detection of fiducial points by expressing the signal as a small number of vertices. However, dynamic programming, a global optimization method used for linear approximation, has the disadvantage of high complexity using memoization. In this paper, the calculation area and memory usage are improved using a linear approximated template. The proposed algorithm reduces the calculation area required for dynamic programming through local optimization around the vertices of the template. In addition, it minimizes the storage space required by expressing the time information using the error from the vertices of the template, which is more compact than the time difference between vertices. When the length of the signal is L, the number of vertices is N, and the margin tolerance is M, the spatial complexity improves from O(NL) to O(NM). In our experiment, the linear approximation processing time was 12.45 times faster, from 18.18 ms to 1.46 ms on average, for each beat. The quality distribution of the percentage root mean square difference confirms that the proposed algorithm is a stable approximation.

FM-CW 레이더 거리계의 비트 신호 스펙트럼 상관성을 이용한 고정밀 측정 알고리듬 (Correlation Algorithm for High-Precision Measurement in FM-CW Radar Level Meters)

  • 김정목;임종수;전중창;김태수;심재윤;박위상
    • 대한전자공학회논문지TC
    • /
    • 제38권4호
    • /
    • pp.38-44
    • /
    • 2001
  • 본 논문에서는 FM CW 레이더의 원리를 이용한 마이크로파 거리계에서 비트 신호(beat signal)의 스펙트럼 상관도(correlation)를 해석하고, 이를 이용하여 고 정밀도를 실현할 수 있는 거리 측정 알고리듬을 제안한다. 산업 자동화용과 같이 고 정밀도를 요구하는 경우, 거리계에 사용되는 VCO의 주파수 선형도가 매우 우수하여야 한다. 그러나 실제 VCO의 선형도를 높이기 위해서는 고가의 VCO나 복잡한 선형화 회로가 필요하며, 이는 장비 자체의 제작 비용을 높이는 요인이 된다. 거리 차가 충분히 작은 표적물에 대한 두 비트 신호의 주파수 스펙트럼간에는 상관도에서 침투지를 나타내는 주파수 ???V(offset)이 존재하게 되며, 본 논문에서는 이를 바탕으로 일반적인 VCO를 사용하더라도 정밀한 측정을 할 수 있는 상관 알고리듬을 제안한다. 제안된 알고리듬의 타당성을 검증하기 위한 측정 결과를 제시하였다.

  • PDF

헬기 탑재 레이다 고도계 신호 수집 및 오차 분석 (Altitude Error Analysis of Helicopter-Borne FMCW Radar Altimeter)

  • 정정수;이호준;곽영길
    • 한국전자파학회논문지
    • /
    • 제23권2호
    • /
    • pp.258-261
    • /
    • 2012
  • FMCW 방식의 헬기 탑재 레이다 고도계는 직하 방향의 지표면 반사신호의 크기에 대한 송수신 차의 주파수를 측정하여 고도정보를 추출한다. 그러나 넓은 안테나 빔 폭으로 인하여 빔 폭 내에 RCS가 큰 물체에 의한 반사신호가 수신되면 직하 지점으로 오인하여 고도 오차를 발생시킬 수 있다. 본 논문에서는 고도 측정의 오차를 야기시킬 수 있는 요인을 분석하기 위하여 삼면반사기를 이용한 기준 신호와 직하 방향 주변에 RCS가 큰 지형지물을 이용한 반사신호를 수집하여 주파수 영역에서 비교 분석하였다. 실험 분석결과는 향후 레이다 고도 정확도를 향상을 위하여 활용될 수 있도록 제시되었다.

청각 기억 게임을 위한 리듬 유사도 측정 기술 (Measurement of Rhythmic Similarity for Auditory Memory Game)

  • 김주완;이세원;박호종
    • 한국음향학회지
    • /
    • 제30권3호
    • /
    • pp.136-141
    • /
    • 2011
  • 본 논문에서는 청각 기억 게임을 위하여 두 개의 소리 파형을 비교하여 파형의 리듬 유사도를 정량적으로 측정하는 기술을 제안한다. 제안한 방법은 두 입력 파형에 대하여 에너지 변화, 에너지 피크의 지속 시간, 음색 등을 분석하여 각 파형에 포함된 비트 위치를 검출하고, 두 파형의 템포 차이와 비트 수의 차이를 보상하는 과정을 통하여 두 파형의 리듬 벡터를 각각 정의한다. 다음, 두 리듬 벡터 사이의 차이와 비트 수의 차이를 적용하여 두 입력 파형의 리듬 유사도를 정량적으로 표현하는 식을 정의한다. 제안한 방법으로 측정한 리듬 유사도와 주관적 청취 평가로 측정한 리듬 유사도를 비교하였으며, 두 방법에 의한 리듬 유사도가 상관도 0.86을 가지는 것을 확인하였다.

FMCW 차량용 레이더의 이동타겟 탐지 알고리즘 제안 (Moving Target Detection Algorithm for FMCW Automotive Radar)

  • 현유진;오우진;이종훈
    • 전자공학회논문지SC
    • /
    • 제47권6호
    • /
    • pp.27-32
    • /
    • 2010
  • 오늘날 FMCW 레이더 시스템은 차량의 능동 안전 시스템에 널리 활용되어지고 있다. 레이더 시스템에서 탐지확률을 높이고 오경보율을 줄이기 위해서는 정지타겟을 포함한 클러터 성분을 제거하고 관심 있는 이동타겟을 효과적으로 탐지하기 위한 알고리즘이 필요하다. 본 논문에서는 이동타겟 탐지 및 클러터 제거 알고리즘을 제안한다. 먼저 제안된 이동타겟 비트주파수 검출 필터를 이용하여 클러터를 제거한다. 검출된 이동타겟 비트주파수들을 이용하여 데이터-결합 한 후, 제로-도플러 제거 알고리즘을 이용하여 남아있는 클러터를 제거한다. 이 알고리즘을 검증하기 위해 실제 FMCW 레이더를 이용하여 도로 상에서 실험하였다.

한국 범종에 대한 음향 및 선호도 분석 (Acoustic Characteristics and Timbre Preferences of Korean Bells)

  • 박상하;이민구;한나라;성굉모
    • 한국음향학회지
    • /
    • 제30권5호
    • /
    • pp.273-280
    • /
    • 2011
  • 본 논문에서는 전국 각지의 범종 소리를 녹음하고 이를 크기에 따라 두 개의 그룹으로 분류한 후, 두 그룹에 대하여 주관청취 평가를 시행하여 사람들이 어떤 범종 소리를 선호하는지 조사하였다. 또한, 범종 음향 분석을 통해 부분음의 위치, 크기, 맥놀이 주기, 20 dB 감쇠 시간을 분석하였다. 이후, 분석된 음향학적 파라미터와 선호도의 상관관계를 파악함으로써 선호도가 높은 범종과 선호도가 낮은 범종을 구분짓는 음향학적 특징을 알아보았다.

A Pacemaker AutoSense Algorithm with Dual Thresholds

  • Kim, Jung-Kuk;Huh, Woong
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권6호
    • /
    • pp.477-484
    • /
    • 2002
  • A pacemaker autosense algorithm with dual thresholds. one for noise or tachyarrhythmia detection (noise threshold, NT) and the other for intrinsic beat detection (sensing threshold. ST), was developed to improve the sensing performance in single pass VDD electrograms. unipolar electrograms, or atrial fibrillation detection. When a deflection in an electrogram exceeds the NT (defined as 50% of 57), the autosense algorithm with dual thresholds checks if the deflection also exceeds the ST. If it does, the autosense algorithm calculates the signal to noise ratio (SNR) of the deflection to the highest deflection detected by NT but lower than ST during the last cardiac cycle. If the SNR 2, the autosense algorithm declares an intrinsic beat detection and calculates the next ST based on the three most recent intrinsic peaks. If the SNR $\geq$2, the autosense algorithm checks the number of deflections detected by NT during the last cardiac cycle in order to determine if it is a noise detection or tachyarrhythmia detection. Usually the autosense algorithm tries to set the 57 at 37.5% of the average of the three intrinsic beats, although it changes the percentage according to event classifications. The autosense algorithm was tested through computer simulation of atrial electrograms from 5 patients obtained during EP study, to simulate a worst sensing situation. The result showed that the ST levels for autosense algorithm tracked the electrogram amplitudes properly, providing more noise immunity whenever necessary. Also, the autosense algorithm with dual thresholds achieved sensing performance as good as the conventional fixed sensitivity method that was optimized retrospectively.

순방향 마이크로초 단위의 실시간 편광상태 검출 시스템 (A Feed-forward Microsecond Level Real-time SOP Finding System)

  • 정현수;신서용
    • 한국통신학회논문지
    • /
    • 제33권1C호
    • /
    • pp.94-101
    • /
    • 2008
  • 본 논문에서는 실시간으로 빛의 편광상태(SOP)를 파악할 수 있는 장치를 소개한다. 소개하는 장치는 광파를 수평 선형편광과 수직 선형편광 성분으로 분리하고, 각각을 기준 광원의 수평 선형편광 및 수직 선형편광 성분들과 중첩시키고 이로부터 발생한 비트신호들을 시간 영역에서 측정하여 비교함으로써 광파의 SOP를 파악해 내는 순방향(feed-forward) 측정 시스템으로서 귀환(feedback) 방식을 이용하는 기존의 방식들에 비해 SOP 측정시간을 실시간으로 단축시키는 장점을 갖고 있다. 본 논문에서는 또한 SOP 측정 과정에서 수반될 수 있는 광소자의 복굴절 변화에 의한 측정 오차를 매우 간편하고 정확하게 제거할 수 있는 새로운 오차 보정 방식을 소개한다. 제안하는 시스템의 동작과 성능을 모의실험 및 광학 실험을 통해 입증하였다.

A Discrete State-Space Control Scheme for Dynamic Voltage Restorers

  • Lei, He;Lin, Xin-Chun;Xue, Ming-Yu;Kang, Yong
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.400-408
    • /
    • 2013
  • This paper presents a discrete state-space controller using state feedback control and feed-forward decoupling to provide a desirable control bandwidth and control stability for dynamic voltage restorers (DVR). The paper initially discusses three typical applications of a DVR. The load-side capacitor DVR topology is preferred because of its better filtering capability. The proposed DVR controller offers almost full controllability because of the multi-feedback of state variables, including one-beat delay feedback. Feed-forward decoupling is usually employed to prevent disturbances of the load current and source voltage. Directly obtaining the feed-forward paths of the load current and source voltage in the discrete domain is a complicated process. Fortunately, the full feed-forward decoupling strategy can be easily applied to the discrete state-space controller by means of continuous transformation. Simulation and experimental results from a digital signal processor-based system are included to support theoretical analysis.

심전도 자동 진단 알고리즘 및 장치 구현(V) - 진단 파라미터 추출 및 진단기 (An implementation of automated ECG interpretation algorithm and system(IV) - diagnosis parameter extractor and classifier)

  • 권혁제;정기삼;이정환;신건수;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.298-302
    • /
    • 1996
  • The representative beat with high SNR could be obtained by the signal averaging, correct and fast detection of significant points and waveform boundary could be obtained by adoption of search interval. All experimental results of waveform boundary were compared with CSE database which had the 5 referees results and 11 ECG measurement programs. All results were within tolerance made by referees, especially the end point of T wave were more close to the referee's results than other 11 measurement programs. The diagnosis parameters that might be used in the Minnsota code criteria were extracted from the representative beat. The diagnostic classification were fulfilled using Minnsota code criteria. Through the comparison on the diagnosis results from designed automated ECG analyzer(YECGA) and the results ECG analyzer manufactured by Fukuda denshi(FCG-2201) in Japan, reliance of the performance on designed system(YECGA) could be validated.

  • PDF