• 제목/요약/키워드: Bearing Vibration

검색결과 968건 처리시간 0.027초

구름요소의 Waviness 를 고려한 볼베어링 해석 이론 (Analytical Theory of Ball Bearing Considering Waviness of Rolling Elements)

  • 정성원;장건희
    • 한국소음진동공학회논문집
    • /
    • 제11권7호
    • /
    • pp.275-286
    • /
    • 2001
  • The research presents an analytical theory to calculate the characteristics of the bal bearing with waviness in its rolling elements considering the centrifugal force and gyroscopic moment of bal. The effects of centrifugal force and gyroscopic moment are introduced to the kinematic constraints and force equilibrium equations. and the waviness of rolling elements is modeled by sinusoidal function to calculate the contact force at each ball. The numerical solutions of governing equation of berating due to waviness are calculated by using the Newton-Raphson method. The accuracy of the research is validated by comparing the contact force. contact angle in case of considering the centrifugal force and gyroscopic moment of bal and the contact force and vibration frequencies in cases of considering waviness with the prior researches respectively. It investigates the stiffness, contact force. displacement and vibration frequencies of the ball bearing considering not only the centrifugal force and gyroscopic moment of ball but also the waviness of the rolling elements.

  • PDF

저널베어링 상태 진단을 위한 최적의 데이터 분석 기준 설정 (Optimal Datum Unit Definition for Diagnostics of Journal Bearing System)

  • 윤병동;정준하;전병철;김연환;배용채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.84-89
    • /
    • 2014
  • Data-driven method for fault diagnostics system often use machine learning technique. To use such technique proper signal processing should be implemented such as time synchronous averaging (TSA) for ball bearing systems. However, for journal bearing diagnostics systems not much has been researched, and yet a proper signal processing method has not been studied. Therefore, in this research an optimal datum unit for a reliable journal bearing diagnostics system along with angular resampling process is being suggested. Before extracting time and frequency domain features, angular resampling is applied to each cycle of vibration data. As to preserve the characteristics of vibration signal, averaging method is replaced by finding the optimal datum unit which strengthens statistical characteristics of vibration signal. Then 20 features were extracted for various cases, and those features are being evaluated by two criteria, separability and classification accuracy.

  • PDF

베어링 재설계에 의한 원전 COP motor의 진동 제어 (Vibration Control of Condensate Motors in Nuclear Powerplant By Bearing Redesign)

  • 임도형;김원현;이종문;이수목
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the summary of control of abnormal vibration found in the COP motors of a nuclear power plant. All six identical units of COP pump-motor assemblies showed unstable vibration pattern of which one or two showed higher vibration enough to exceed the allowable level from the installation stage. Many trials of test, measurement, overhaul and replacement had been repeated to investigate and solve the problem but only to reach unsatisfactory settlement. Recently several times of site tests are made and followed by significant diagnostic actions in which the authors group participated. It was found that the coupled shafting system of motor and pump is in close resonance with the $1^{st}$ shaft rotating speed. Redesign of topside motor bearing clearance is made to increase bearing stiffness and hence to avoid the resonance which consequently led to reduce the troubled vibration to allowable and stable status.

  • PDF

Support Vector Machine Based Bearing Fault Diagnosis for Induction Motors Using Vibration Signals

  • Hwang, Don-Ha;Youn, Young-Woo;Sun, Jong-Ho;Choi, Kyeong-Ho;Lee, Jong-Ho;Kim, Yong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1558-1565
    • /
    • 2015
  • In this paper, we propose a new method for detecting bearing faults using vibration signals. The proposed method is based on support vector machines (SVMs), which treat the harmonics of fault-related frequencies from vibration signals as fault indices. Using SVMs, the cross-validations are used for a training process, and a two-stage classification process is used for detecting bearing faults and their status. The proposed approach is applied to outer-race bearing fault detection in three-phase squirrel-cage induction motors. The experimental results show that the proposed method can effectively identify the bearing faults and their status, hence improving the accuracy of fault diagnosis.

중형 컨테이너 운반선 축계장치의 선미관 선수베어링 설치 유무에 따른 횡진동 사례 연구 (A Case Study on the Lateral Vibration of Shafting System in context of forward stern tube bearing for Medium Size Container Ship)

  • 이재웅
    • 수산해양교육연구
    • /
    • 제28권3호
    • /
    • pp.645-652
    • /
    • 2016
  • At the initial stage of propulsion shaft design, in line with shaft alignment, an intensified consideration of lateral vibration is needed to verify its operational safety. Recently the alignment problem affecting the lateral vibration has been becoming issues. However, the theoretical method of forced lateral vibration analysis is not cleary established so far and it is about to simply limited among the classification societies and international standards to avoid the blade natural frequency resonance cpm outside of ${\pm}20%$ of engine rpm at MCR. On the other hand, longer center distance between each support bearing shows an affirmative result normally in shaft alignment analysis whereas the blade order resonance speed may cause lowering near the limitation in the aspect of lateral vibration. Therefore, it is required careful attention to engineers as described above. As a method to solve the problem, it is mainly considered that remove forward stern tube bearing. In this paper, based on a medium size container ship case, theoretical study was carried out in the context of the forward stern tube bearing. The various effects and functions of forward stern tube bearing are reviewed and evaluated. Then an guidance note to lead the conclusion is proposed.

회전 물체의 동적 하중에 대한 능동 진동 제어 (Dynamic Load Suppression in Active Vibration Control of Rotating Machinery)

  • 김주형;김상섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1126-1131
    • /
    • 2001
  • Excessive vibration in rotating machinery is a problem encountered in many different fields, causing such difficulties as fatigue of machinery components and failure of supporting bearings. Passive techniques, though sometimes limited in their capabilities, have been used in the past to attenuated vibrations. Recently active techniques have been developed to provide vibration control perform beyond that provided by their passive counters. Most often, the focus of active control methods has been to suppress rotating machinery displacements. In cases where vibration results in bearing failures, displacement suppression may not be the best choice of control approaches (it can, in fact, increase dynamic bearing loads which would be even more harmful to bearings). This paper presents two optimal control methods for attenuating steady state vibrations in rotating machinery. One method minimizes shaft displacements while the other minimizes dynamic bearing reaction forces. The two methods are applied to a model of a typical rotating machinery system and their results are compared. It is found that displacement minimization can increase bearing loads, while bearing load minimization, on the other hand, decreases bearing loads.

  • PDF

공기포일 자기 하이브리드 베어링으로 지지되는 연성 축의 휨 모드 진동 제어 (Bending Mode Vibration Control of a Flexible Shaft Supported by a Hybrid Air-foil Magnetic Bearing)

  • 정세나;안형준;김승종;이용복
    • Tribology and Lubricants
    • /
    • 제27권2호
    • /
    • pp.57-64
    • /
    • 2011
  • Hybrid air-foil magnetic bearing integrates two oil free bearing technologies synergetically to adopt the strengths of two bearings with minimizing their weaknesses. This paper presents bending mode vibration control of a flexible shaft supported by the hybrid air-foil magnetic bearing. An experiment set-up of a flexible shaft supported by the hybrid air-foil magnetic bearing is built. In order to verify the effectiveness of the hybrid bearing, unbalance responses of the flexible shaft supported by three different bearings: air-foil, magnetic and hybrid bearings are compared. Effect of load sharing between air-foil and magnetic bearings are investigated through changing the control gain and the rotor center position of magnetic bearing. The experimental results shows that the hybrid bearing can control the bending mode vibration of the flexible shaft effectively and an optimal performance can be achieved with an appropriate load sharing between the air-foil and the magnetic bearings.

기어박스에서의 베어링 결함 진단 (Bearing Fault Diagnostics in a Gearbox)

  • 김흥섭;이상권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.611-616
    • /
    • 2002
  • Bearing diagnostics is difficult in a gearbox because bearing signals are masked by the strong gear signals. Self adaptive noise cancellation(SANC) is useful technique to seperate bearing signals from gear signals. While gear signals are correlated with a long correlation length, bearing signals are not correlated with a short length. SANC seperates two components on the basis of correlation length. Then we can find defect frequency component in the envelope spectrum of the bearing signals.

  • PDF

과급기 축계의 진동 해석 (Vibration Analysis of Turbocharger Rotor-Bearing System)

  • Suk, Ho-Il;Yang, Bo-Suk;Song, Jin-Dea
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.400.2-400
    • /
    • 2002
  • Recently rotating machines have became high speed and high Power and light weight. Bearings are one of the main components which influence power loss and stability of rotating machines. Appropriate bearing should be selected with considering characteristics of rotating machine. Floating ring journal bearing(FIB) consists of an inner film and outer film, and possess high damping and stability. FJB has been for adopted into turbocharger for the high stability at high operating speed. (omitted)

  • PDF