• 제목/요약/키워드: Bearing Support

검색결과 415건 처리시간 0.023초

Simulation of the behaviour of RC columns strengthen with CFRP under rapid loading

  • Esfandiari, Soheil;Esfandiari, Javad
    • Advances in concrete construction
    • /
    • 제4권4호
    • /
    • pp.319-332
    • /
    • 2016
  • In most cases strengthening reinforced concrete columns exposed to high strain rate is to be expected especially within weak designed structures. A special type of loading is instantaneous loading. Rapid loading can be observed in structural columns exposed to axial loads (e.g., caused by the weight of the upper floors during a vertical earthquake and loads caused by damage and collapse of upper floors and pillars of bridges).Subsequently, this study examines the behavior of reinforced concrete columns under rapid loading so as to understand patterns of failure mechanism, failure capacity and strain rate using finite element code. And examines the behavior of reinforced concrete columns at different support conditions and various loading rate, where the concrete columns were reinforced using various counts of FRP (Fiber Reinforcement Polymer) layers with different lengths. The results were compared against other experimental outcomes and the CEB-FIP formula code for considering the dynamic strength increasing factor for concrete materials. This study reveals that the finite element behavior and failure mode, where the results show that the bearing capacity increased with increasing the loading rate. CFRP layers increased the bearing capacity by 20% and also increased the strain capacity by 50% through confining the concrete.

비대칭 Groove를 이용한 FDB 회전축의 기울기 보상 (Compensation of Inclined Rotating Axis Using Unsymmetric Groove Patterns)

  • 이남훈;한재혁;오동호;김철순;변용규;구자춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.582-585
    • /
    • 2004
  • Most of hard disk drives currently employ fluid dynamic bearing (FDB) for their rotor support. Stiffness of the FDB is affected by many design factors such as bearing clearance, fluid viscosity, and rotational speed. For the high rotating speed HDDs stiffness of the rotor is normally high enough to accomodate load disturbances. However small form factor HDDs that are to be operated in low power consumption are often designed with low stiffness rotors. Although the low stiffness rotor clearly benefits low power operation, it could damage the entire motor structure or head disk interface even by a light mechanical load disturbance such as shock or vibration. In addition, since a single channel HDD does not provide gram load equilibrium in axial direction the rotor could be tilted and make a hard contact to stator. A non-symmetric groove pattern could successfully compensate the tilted rotor angle during operation.

  • PDF

An experimental and numerical analysis of concrete walls exposed to fire

  • Baghdadi, Mohamed;Dimia, Mohamed S.;Guenfoud, Mohamed;Bouchair, Abdelhamid
    • Structural Engineering and Mechanics
    • /
    • 제77권6호
    • /
    • pp.819-830
    • /
    • 2021
  • To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000℃ with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400℃.

PLAXIS 3D simulation, FLAC3D analysis and in situ monitoring of Excavation stability

  • Lei, Zhou;Zahra, Jalalichi;Vahab, Sarfarazi;Hadi, Haeri;Parviz, Moarefvand;Mohammad Fatehi, Marji;Shahin, Fattahi
    • Structural Engineering and Mechanics
    • /
    • 제84권6호
    • /
    • pp.743-765
    • /
    • 2022
  • Near-surface excavations may cause the tilting and destruction of the adjacent superstructures in big cities. The stability of a huge excavation and its nearby superstructures was studied in this paper. Some test instruments monitored the deformation and loads at the designed location. Then the numerical models of the excavation were made in FLAC3D (a three-dimensional finite difference code) and Plaxis-3D (a three-dimensional finite element code). The effects of different supporting and reinforcement tools such as nails, piles, and shotcretes on the stability and bearing capacity of the foundation were analyzed through different numerical models. The numerically approximated results were compared with the corresponding in-field monitored results and reasonable compatibility was obtained. It was concluded that the displacement in excavation and the settlement of the nearby superstructure increases gradually as the depth of excavation rises. The effects of support and reinforcements were also observed and modeled in this study. The settlement of the structure gradually decreased as the supports were installed. These analyses showed that the pile significantly increased the bearing capacity and decreased the settlement of the superstructure. As a whole, the monitoring and numerical simulation results were in good consistency with one another in this practically important project.

H강재와 UHPC압축블록을 적용한 슬래브용 열교차단 단열구조체 실험 및 해석연구 (Experiment and Analysis of Load-Bearing Insulations for Slabs Thermal Breaks composed by H-Shaped Stainless Steel and UHPC Blocks)

  • 김재영;이가윤;유영종;안상희;이기학
    • 한국공간구조학회논문집
    • /
    • 제23권3호
    • /
    • pp.35-43
    • /
    • 2023
  • This study aims to evaluate the structural safety of a structural thermal barrier, installed inside the structure of a building and performed the role of a load-bearing element and an insulation simultaneously, contributing to the realization of net-zero buildings. To ensure the reliability of the analysis model, the analysis results derived from LS-DYNA were compared with the experimental results. Based on the results shown through the flexural experiment, the reliability of the thermal cross-section insulation structure model for slabs was validated. In addition, the effect of the UHPC block on the load support performance and its contribution to vertical deflection was verified.

포트받침의 마찰요소 이탈을 고려한 전단거동 실험 평가 (Experimental Evaluation of Shear Behavior Considering Friction Element Detachment on Pot Bearing)

  • 윤혜진;조창백;김영진;강준원
    • 한국지진공학회논문집
    • /
    • 제27권4호
    • /
    • pp.181-186
    • /
    • 2023
  • In this study, considering the expansion/contraction behavior of the upper structure at all times and the abnormal behavior of the receiving friction elements that allow horizontal movement during earthquakes, a port receiving test body simulating the protrusion of the friction elements was created and the modulus performance was evaluated. In order to confirm the influence of the friction element's projection, the friction element's degree of separation was divided into four stages, and the shear behavior of the test specimen and the friction coefficient were confirmed. As a result of the experiment, it was found that the friction load increases as the protrusion degree of the friction element increases. On the other hand, as the degree of protrusion of the coefficient of friction increases, the coefficient of friction also increases. It was confirmed that damage to the friction elements during use increases the coefficient of friction, hinders smooth expansion and contraction of the upper structure, and causes stress concentration at the fixed-end support.

Effects of foot pressure using the elastic band with rings during sit-to-stand in persons with stroke

  • Hwang, Young-In;Kim, Ki-Song
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권4호
    • /
    • pp.159-163
    • /
    • 2017
  • Objective: Persons with stroke have a tendency to exhibit asymmetric weight-bearing during sit-to-stand because due to the attempt to support themselves with the non-paretic foot. However, there are few devices that can assist with sit-to-stand (STS) performance. This study was designed to investigate the use of the elastic band with rings (EBR) in improving weight-bearing effectively in persons with stroke during STS training. Design: Cross-sectional study. Methods: Thirteen stroke survivors participated in the study. An EBR was applied onto the patient during STS activity. The foot pressure was measured before and after wearing the EBR, with a 5-minute rest period between measurements. Subjects were asked to perform each test twice with and without the EBR. Bilateral feet pressures were measured with standing posture being divided into the forward and backward aspects. The foot contact pressure during STS activity was measured with the CONFORMat System. Results: With EBR, the forward pressure of the affected foot significantly increased while the less-affected forward foot pressure significantly decreased (p=0.015 and p=0.023, respectively). The backward foot pressure did not differ significantly in the two limbs, and there was no difference with and without the EBR in terms of the total pressure of the affected foot. There was a significant difference with and without the EBR in the total pressure of the less-affected foot (p<0.05). Conclusions: STS training with the EBR has been shown to improve weight-bearing of both feet while decreasing the total pressure of the less-affected foot in stroke survivors. Therefore, we suggest that the EBR is a useful tool for STS training for persons with stroke in the clinic.

원심모형실험기를 이용한 철도 교대접속부 배면 기울기 및 형상에 따른 성능비교 (Comparison of Performance with Backfill Inclination Slope and Shape in Railway Abutment and Transitional Zone Using Centrifuge Model Tester)

  • 최찬용;김현기;박정현
    • 한국지반신소재학회논문집
    • /
    • 제17권1호
    • /
    • pp.85-93
    • /
    • 2018
  • 현행 고속철도 교대 접속부 표준단면은 교대배면에서부터 시멘트안정처리골재, 일반골재, 토공부로 하부 지지강성이 점진적으로 변화하도록 설계하고 있다. 일반골재와 토공부의 배면기울기는 기울기가 클수록 구조적으로 안정적이지만 이에 대한 명확한 기준이 없다. 따라서 본 논문에서는 대형 원심모형실험기를 이용하여 교대 뒤채움 배면구간의 토공과 일반골재의 기울기를 변화하여 현행 표준단면과 침하 및 지지력 특성을 비교하였다. 실험결과 철도하중이 경험하는 하중단계에서는 1:2단면과 1:1.5 기울기 단면이 거의 유사한 성능을 가지고 있는 것으로 평가되었다.

고속 운전용 건식진공펌프 로터-베어링 시스템의 회전체동역학 해석 (Rotordynamic Analysis of a Dry Vacuum Pump Rotor-Bearing System for High-Speed Operation)

  • 이안성;이동환;김병옥
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.523-530
    • /
    • 2006
  • A rotordynamic analysis was performed with a dry vacuum pump, which is a major equipment in modern semiconductor and LCD manufacturing processes. The system is composed of screw rotors, lobes picking air, helical gears, driving motor, and support rolling element hearings of rotors and motor. The driving motor-screw rotor system has a rated speed of 6,300rpm, and was modeled utilizing a rotordynamic FE method for analysis, which was verified through the results of its 3-D finite element model. As loadings on the bearings due to the gear action were significant in the system considered, each resultant bearing load was calculated determinately and indeterminately by considering the generalized forces of the gear action as veil as the rotor itself. Each resultant hearing loading was used in calculating each stiffness of rolling element bearings. Design goals are to achieve wide separation margins of critical speeds and favorable unbalance responses of the rotor in the operating range. Then, a complex rotordynamic analysis of the system was carried out to evaluate its forward synchronous critical speeds, whirl natural frequencies and mode shapes, and unbalance responses under various unbalance locations. Results show that the entire system is well designed in the operating range. In addition, the procedure of rotordynamic analysis for dry vacuum pump rotor-bearing system was proposed and established.

  • PDF

3차원 수치해석을 이용한 대구경 무용접 복합말뚝의 지지거동 분석 (Evaluation of Bearing Capacities of Large Size Non-welded Composite Piles by 3-Dimensional Numerical Analysis)

  • 박재현;김성렬;;정문경
    • 한국해양공학회지
    • /
    • 제25권6호
    • /
    • pp.35-41
    • /
    • 2011
  • Recently, as large structures, which should support large design loads have been constructed, the study on the large diameter composite pile becomes necessary. The large diameter composite pile has the diameter over 700mm and consists of two parts of the upper steel pipe pile and the lower PHC pile by a mechanical joint. In this research, to analyze the bearing capacity and the material strength of the composite pile, three dimensional numerical analyses were performed. First, the numerical modeling method was verified by comparing the calculated load-movement curves of the pile with those of the field pile load tests. Then, a total of twelve analyses were performed by varying pile diameter and loading direction for three pile types of PHC, steel pipe and composite piles. The results showed that the vertical and the horizontal load-movement curves of the composite pile were identical with those of the steel pipe pile and the horizontal material strength of the composite pile was 60-80% larger than that of the PHC pile.