• Title/Summary/Keyword: Beam-slab system

Search Result 136, Processing Time 0.024 seconds

Support Deflection Effects in Slabs with Beam and Girder (보-거더 시스템 슬래브에서 지지부 처짐영향에 관한 연구)

  • 곽효경;송종영
    • Computational Structural Engineering
    • /
    • v.11 no.1
    • /
    • pp.237-249
    • /
    • 1998
  • In this study the support deflection effects in beam-girder slabs which are broadly being adopted in building structures are studied for both distributed loads and concentrated vehicle loads. Taking the finite element analysis of slabs supported with one or two cross beams, the member forces of slabs including the support stiffness have been calculated. Based on the obtained numerical results and regression analysis of those, correction factors of member forces for slabs supported with girders and cross beams have been proposed. Finally, the validity of the proposed correction factors are demonstrated through a typical design example.

  • PDF

A Study on Optimum Section of New Type Steel-Concrete Composite Beam (신형상 층고절감형 합성보의 최적단면 도출에 관한 연구)

  • Yoon, Myung-Ho;Lee, Yoon-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.30-35
    • /
    • 2011
  • This study investigates the optimum section properties of newly developed steel-concrete composite beam. For that purpose we developed computer program calculating section properties. The suggested new beam section highly contribute to save inter-story height and reduce construction duration and cost compared with conventional steel works such as H-beam and column + RC slab system. But the section shape have different section modulus with upper and lower fiber because of the unsymmetric cross section. Therefore the parametric study on thickness-ratio of top and bottom flange plate is needed. In this paper the change of neutral axis and section modulus for thickness-ratio of up and down flage plate is analysed and discussed.

An Analysis of the Orthotropic Curved Circular Ring Sector Plates (곡선경계를 갖는 철근 콘크리트 이방성 선형판의 해석)

  • 노홍민;조진구
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.258-264
    • /
    • 1999
  • In this study, a computer program was developed for analysis of the orthotropic curved ring sector plates. In the developing program , the thin-plate theory and multi-base coordinate system was adopted. The effect of design factors-boundary conditions, loading conditions, steel ratio, open angle, radius of curvature and relative flexural rigidity between slab and edge-beam-on the behavior of the circular ring sector plates were discussed. Also, the practical limitations was proposed to replace the problem of the orthotropic sector plate by equivalent rectangular plage.

  • PDF

Shear Capacity of Precast Concrete Triple Ribs Slab (프리캐스트 콘크리트 트리플 리브 슬래브의 전단성능)

  • Hwang, Seung-Bum;Seo, Soo-Yeon;Lee, Kang-Cheol;Lee, Seok-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.489-496
    • /
    • 2016
  • Recently, a concern about hollow core precast concrete (PC) slab has been increased as a method to improve the construction ability by reducing the self weight of structures during the construction. Hollow core slab which is known as a typical PC slab in domestic construction of PC building has a problem to put shear reinforcements in the web of element during the production of element in the factory. With regard to this point, recently, tripple ribs slab (TRS) which can be said as a new type of half PC slab system was developed. In TRS, it is possible to place shear reinforcements in PC element during the production of the element in the factory. This paper presents the shear test result of TRS which was done by one point loading test under simple support condition. Test parameters are the presence of cast-in-place (CIP) concrete and the contribution of lattice bars. From the test, it was found that the TRS has sufficient shear capacity to resist the design load and its strength can be predicted by the code equations for general beam. It is recommended to ignore the strength of lattice bar in the calculation of shear strength during the construction since its contribution is too low to be considered when CIP is not casted.

Economics on Structural Floor Systems of Super Tall Buildings

  • Shin Sung-Woo;Ahn Jong-Moon;Choi Myung-Shin;Seo Dae-Won;Kim Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.609-613
    • /
    • 2004
  • An economic analysis is one of the most dominant factors to determine the project feasibility of super tall building. In economic considerations, it is very important toadopt optimum structural floor systems because these are dependent on both the cost and the duration of construction. The economics affected by structural floor systems are more distinct athigher story. As the story increases, the construction cost of floor system. is accumulated linearly, while the cost of lateral resisting system is increased geometrically. The purpose of this study is to investigate the economical effects of super tall buildings through application of optimum structural floor systems. Three types of structural systems(RC beam-column frame, RC flat plate frame, and Steel frame) of super tall buildings having 50-stories are considered in this study and compared to RC flat plate slab with other systems. Analytical result shows that RC flat plate slab using lightweight concrete ismost effective in both the cost and the duration of construction.

  • PDF

Performance Analysis of SMART Frame Applied to RC Column-Beam Structures (RC 라멘조에 SMART Frame 적용 시 효용성 분석)

  • Cho, Wonhyun;Lim, Chaeyeon;Jang, Duk Bea;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.168-169
    • /
    • 2015
  • SMART Frame is a composite precast concrete structure system to deliver the advantages of both steel frame and reinforced concrete. Many studies have established to date that SMART Frame is more advantageous than conventional frame-type structure in terms of structural stability, constructability, economic viability as well as reduction of construction schedule. However, such studies have focused primarily on wall-type or flat slab-type apartment housing structures, failing to include Rahmen structures in their scope. Accordingly, this study aims to analyze the benefits of potential application of SMART Frame to RC Rahmen structures. As the structural stability and constructability of SMART Frame is already proven, this study reviews its benefits from the perspective of cost reduction. Conclusion of this study will be used subsequently in predicting the benefits of SMART Frame when it is adapted to RC Rahmen structures.

  • PDF

A Study on the Design of 16-Channel AWG Wavelength Division Multiplexer for Super High-Speed Optical Communication (초고속 광통신을 위한 16-Channel AWG 파장다중화기의 설계에 관한 연구)

  • Cho, Myung-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.3
    • /
    • pp.148-154
    • /
    • 2005
  • Various methods for analyze optical components which are necessary before the fabrication of optical circuit component and as its applications, designing method of Wavelength Division Multiplexer(WDM) filter using arrayed-waveguide grating(AWG) is paper. In the case of analyzing uniform optical waveguide, effective index method(EIM), harmonic expansion method are used, and in the case of non-uniform optical waveguide, beam propagation method(BPM) are used. In this paper, to use arrayed-waveguide grating as WDM filter of centered wavelength of $1.55{\mu}m$ and wavelength spacing of 0.8nm, all of the parameter of AWG is calculated by the HEM and the BPM using EIM. As a result of calculation, free spectral range is 12.8nm, focal length $9336.55{\mu}m$, path difference $129.36{\mu}m$ and the number of slab waveguide 91 when the distance of core center to center on row land circle is $20{\mu}m$.

The Effect of The Flexural Strength Ratio on Beam-Column Joint with High and Low Strength Concrete (고강도와 보통 강도 콘크리트를 사용한 보-기둥 접합부의 휨강성화에 따른 이력거동)

  • Shin, S.W.;An, J.M.;Moon, J.I.;Kim, D.K.;Lee, K.S.;Park, H.M.;Lee, S.H.;Oh, J.G.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.185-190
    • /
    • 1992
  • ACI318-89 Recommended that when the specified compressive strength of concrete in a column is greater than1.4 times that specified for a floor system, top surface of the column concrete shall extend 2ft(600mm)into the slab from the face of column to avoid unexpected brittle failure. The major variables are extension distance, flexural strength ratio(Mr), and shear reinforcement ratio(Vs). Test results are as follows ; (1) The failure modes of specimens under cyclic loading were concentrated at critical region from beam-column joint face. (2) Ductility index($\mu$f) were increased with increasing of shear confinement ratio and flexural strength ratio. (3)The specimens with 2ft extension distance showed more ductility than the specimens with 1ft extension distance.

  • PDF

The Effect on the Extension Distances of Beam-Column Joint with High and Low Strength Concrete (고강도와 보통강도 콘크리트를 사용한 보-기둥 접합부의 내민길이에 따른 구조적 거동)

  • 이광수;안종문;문정일;박희민;장일영;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.90-94
    • /
    • 1992
  • ACI318-89 Recommened that when the specified compressive strength of concrete in a column is greater than 1.4 times that specified for a floor system, top surface of the column concrete shall extend 2ft (600mm) into the slab from the face of column to avoid unexpected brittle failure. The major variables are extension distance, compressive strength of concrete (f'c), shear confinement ratio(Vs), and loading types. The test results showed that the load capacity of the specimen subjected to monotonic loading had more than that of the specimen subjected to one way cyclic loadings. The failure models of specimens under cyclic loading were concentrated at 5∼20cm apart region from beam-column joint face. Ducility index(μf) are increased with increasing of shear confinement ratio. The specimen with 2ft extension distance shows more ductility than specimen with lft extension distance.

  • PDF

A Study on the Superstructure System Analysis of Underground Parting Lot in Apartment. (공동주택 지하주차장 상부구조 형식 분석연구)

  • Lim, Nam-Gi;Song, Hee-Won;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.149-156
    • /
    • 2003
  • The purpose of this study was to find out the most reasonable design in the superstructure of an underground parking lot which needs to be considered with the economic efficiency being influenced on the subdivision price, construction duration, workability and the maintenance of crack and leakage status of apartment house. In this research, we've evaluated the fitness for the superstructure of an underground parking lot by examination of construction constraint, which was based on the calculated data of structural design and quantity survey. The results of this study are summarized as follows. 1. The system of the absent structure of beam is proper structure for economic efficiency, construction duration and workability, but it is disadvantageous at the side of maintenance efficiency because of the many part of large slab. In the opposite direction, the establishing structure of beam has the advantages of structural stability except economic efficiency, construction duration and workability 2. It's required a proper selection for the views being contrary to each other which the owners considers good quality, on the other hand, the contractors consider construction duration and workability. 3. In making a selection for the superstructure of an underground parking lot, we have concluded that it is the most important to choose the proper structure for the demanded performance by contrasting with two system. (2Bay or 3Bay)