• 제목/요약/키워드: Beam-slab system

검색결과 136건 처리시간 0.026초

지하층 HCS 구조시스템의 거동에 따른 설계방법의 고찰 (Consideration of the Design Methods for Underground HCS System)

  • 김혜민;김승훈;김종수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.56-59
    • /
    • 2004
  • This paper presents the consideration of design guideline for underground HCS system, composite spancrete slab, under axial and bending force. Serviceability design requirements for continuous composite spancrete slab subjected axial force, which are allowable stress and deflection, are compared. Flexural strengths are evaluated by design guideline using strain-compatibility method. The results showed that stresses of spancrete and topping concrete, especially at the ends of beam, have much effect on design loads. Maximum service loads for tested specimens are proposed by allowable stress.

  • PDF

SMART 보 거푸집 개발을 위한 요구조건 분석 (Requirement Analysis for Development of SMART Beam Form)

  • 김태구;임채연;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.70-71
    • /
    • 2014
  • The structural work is the main process of building construction which influence on the time, cost, safety and quality. The form work is one of the main process which has from 20 to 30 percentage of structural work. Especially the form work for beams is complex and need more manpower compared with form work for column or slab. When the existing forms such as plywood form, steel framed wooden form and aluminum form, is used for form work of beam, it would result in the cost overrun caused by needs of lots of manpower and resources. Therefore, the aim of this study is analysis of the requirement for development of SMART beam form. The result of this study shall be used for the development of SMART form work system.

  • PDF

트러스근을 사용한 슈퍼데크 플레이트의 구조성능평가 (Structural Performance of Super-Deck Plate Slab System with Truss Type Bar)

  • 김성수;김상식;이우진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.193-199
    • /
    • 2003
  • This paper presents the results of an experimental research project on 7 Super Deck Plates with continuous or simple beam types. The test parameters included the distance of truss, depth of deck plate and the type of beam. The test results are as follows ; When thickness of deck plate was increased, maximum strength was improved When the distance of truss bar was reduced from 20cm to 15cm, the mean value of maximum load was increased to 1.21 times. Continuous beam shown superior to simple beam, such as 5.03 times high strength, low deflection at yield point.

단순지지 T형 합성보의 휨거동에 관한 실험적 연구 (An Experimental Study on the Behavior of the T-type Steel Composite Beam)

  • 김상섭;김상모;김성배;서동기;김규석
    • 한국강구조학회 논문집
    • /
    • 제16권2호통권69호
    • /
    • pp.225-233
    • /
    • 2004
  • 일반적인 합성보는 콘크리트 슬래브와 H형강 철골보 사이에 작용하는 수평전단력을 쉬어 코넥터로 긴결하여 휨 내력 및 강성을 증가시킨 구조이다. 본 연구에서 제안한 TSC 구조는 H형강 대신 U형 철골을 사용하고 그 속에 콘크리트를 채운 새로운 형태의 합성보 시스템으로 실험을 통하여 구조특성을 평가 분석 하였다. 또한 실험결과를 통해 T형 합성보(이하 TSC 보라 칭함)의 구조설계 및 시공에 필요한 기초 자료를 제시하고자 한다.

강구조 재사용 시스템을 위한 탈부착이 가능한 PC 슬래브 접합부의 성능평가 (Performance Evaluation of Removable PC Slab Connection for the Reusable Steel Structural System)

  • 심현주;오은지;이은택
    • 한국강구조학회 논문집
    • /
    • 제25권6호
    • /
    • pp.649-658
    • /
    • 2013
  • 최근 건축 분야에서도 친환경, 순환형 패러다임으로 전환되어지고 있다. 이 연구에서는 사용자의 요구에 따라 구조체의 해체에 의해 재사용이 가능한 구조시스템을 도입하여 건설자재의 절감 및 재활용, 구조체의 장수명화를 통해 친환경 및 $LCCO_2$를 저감할 수 있는 강구조 시스템을 구현하고자 한다. 부재의 재조합이나 재사용을 가능하게 하기 위하여 탈착이 가능한 바닥슬래브와 강재보 접합상세를 제안하고 구조성능 및 진동 등과 같은 동적 특성에 의해 사용성을 파악하고 평가하였다.

무량복합 및 벽식 구조시스템의 내진성능평가 (Seismic Performance Evaluation of Flat Column Dry Wall System and Wall Slab System Structures)

  • 강현구;이민희;김진구
    • 한국전산구조공학회논문집
    • /
    • 제25권3호
    • /
    • pp.259-266
    • /
    • 2012
  • 본 논문에서는 벽식 구조시스템의 일부 전단벽을 제거하여 공간의 가변성을 높인 무량복합 구조시스템의 내진성능을 ATC-63에 제시되어 있는 절차에 따라 파악하였으며, 동일한 규모의 벽식 구조시스템의 내진성능과 비교하였다. 해석모델로 12층 무량복합 및 벽식 구조시스템을 KBC 2009에 따라 설계하고 비선형 정적 및 비선형 증분 동적해석(IDA)을 수행하여 지진응답 및 붕괴거동을 파악하였다. 무량복합 시스템은 벽식 구조시스템 보다 적은 양의 콘크리트 물량으로 설계되었으며, 동일한 지진하중에 대하여 좀 더 큰 변위응답을 보이는 것으로 나타났다. IDA 해석결과 얻어진 붕괴 여유비(CMR)는 ATC-63에 제시된 한계상태를 만족하여 설계지진하중에 대하여 충분한 내진성능을 보유한 것으로 나타났다.

Parametric study on the structural behaviour of composite slim floors with hollow-core slabs

  • Spavier, Patricia T.S.;Kataoka, Marcela N.;El Debs, Ana Lucia H.C.
    • Computers and Concrete
    • /
    • 제28권5호
    • /
    • pp.497-506
    • /
    • 2021
  • Steel-concrete composite structures and precast concrete elements have a common prefabrication process and allow fast construction. The use of hollow-core slabs associated with composite floors can be advantageous. However, there are few studies on the subject, impeding the application of such systems. In this paper, a numerical model representing the considered system using the FE (finite element)-based software DIANA is developed. The results of an experimental test were also presented in Souza (2016) and were used to validate the model. Comparisons between the numerical and test results were performed in terms of the load versus displacement, load versus slip, and load versus strain curves, showing satisfactory agreement. In addition, a wide parametric study was performed, evaluating the influence of several parameters on the behaviour of the composite system: The strength of the steel beam, thickness of the web, thickness and width of the bottom flange of the steel beam and concrete cover thickness on top of the beam. The results indicated a great influence of the steel strength and the thickness of the bottom flange of the steel beam on the capacity of the composite floor. The remaining parameters had limited influences on the results.

친환경 층고 절감형 합성보의 보-기둥 접합부 상세 및 시공성 연구 (Environmental Friendly Connection of Composite Beams and Columns)

  • 홍원기;김진민;박선치;임선재
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.113-118
    • /
    • 2007
  • The composite beam adopted in the study was designed to reduce the floor height as well as to embed the top flange of steel frame into the slab that will enable to avoid applying the fire-resistant coating and to unify the joint method with a steel frame-type. As the steel frame and bottom concrete of the beam is pre-fabricated at the factory it could reduce the overall schedule at the jobsite. Applying such composite beam system to the work is expected to provide the efficient and enhanced performance, given the current tendency of the building construction that tends to be getting higher, larger and dense. The study focused on combining the composite beam with various column systems in a bid to propose the details thereof. A desirable composite girder can be adopted depending on site conditions through the evaluation of various beam and jointing approaches. Among the column systems applied to the study are steel column, SRC column, RC-PC column and RC column. The ways of combining with the columns addressed in the study were categorized into the rigid joint, pin joint, steel frame joint and bracket type joint. Besides, the instruction for site fabrication of beam-column was added in an effort to help set up the site fabrication procedures.

PC 큰 보-PC 작은 보 접합부의 전단성능 평가 (Evaluation of Shear Capacity on PC Girder-PC Beam Joint)

  • 문정호;오영훈;임재형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.166-174
    • /
    • 2011
  • 본 연구는 PC 작은 보의 댑단부와 PC 큰 보의 레져에 대한 전단성능을 평가하기 위한 전단 구조성능 실험연구이다. 일반적으로 작은 보의 댑단부와 큰 보의 레져는 사용하중에 안전하도록 설계하고 있지만, 작은 보의 단부를 연속단으로 설계한다면 작은보의 댑단부와 큰 보의 레져는 고정하중과 시공하중에만 안전하도록 설계할 수 있다. 이에 대한 구조성능을 평가하기 위하여 행거철근 정착방법, 설계하중, 레져보강근유무를 변수로 총 7개 실험체를 제작하여 전단실험을 실시하였다. 실험결과, 댑단부 및 레져가 으로 설계되어도 작은 보의 연속성은 확보될 수 있는 것으로 나타났으며, 전단 임계단면은 지지점으로부터 유효높이(d)만큼 떨어진 위치에서 형성된 후 댑단부로 진전되었다. 그리고 PCI 핸드북에서 레져를 설계할 때 캔틸레버 슬래브와 같은 구조일 때로 해석하고 있는데, 본 공법에서의 레져는 3변 고정 슬래브와 같은 구조이므로 PCI 핸드북에서 정의하는 방법은 본 공법의 레져를 과대설계할 가능성이 있는 것으로 사료된다.

모드해석을 통한 벽식구조 아파트건물의 System Identification (System dentification of Apartment Buildings with Wall-Slab configuration using Modal Analysis)

  • 장극관;천영수
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.191-197
    • /
    • 1998
  • This paper described the dynamic characteristics of 20-story apartment buildings from the results of full-scale measurements and analysis. The natural frequencies and mode shapes are quantified by measuring and analyzing ambient vibrations of the structure and compared with the results from dynamic analysis. Comparison with computed mode shapes and frequencies shows good agreement with the experimental results. It proved that it is important to estimate coupling beam and soil parameters through a comparison of the measured results with calculated results.

  • PDF