• 제목/요약/키워드: Beam source

검색결과 1,026건 처리시간 0.027초

Study on the neutron imaging detector with high spatial resolution at China spallation neutron source

  • Jiang, Xingfen;Xiu, Qinglei;Zhou, Jianrong;Yang, Jianqing;Tan, Jinhao;Yang, Wenqin;Zhang, Lianjun;Xia, Yuanguang;Zhou, Xiaojuan;Zhou, Jianjin;Zhu, Lin;Teng, Haiyun;Yang, Gui-an;Song, Yushou;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1942-1946
    • /
    • 2021
  • Gadolinium oxysulfide (GOS) is regarded as a novel scintillator for the realization of ultra-high spatial resolution in neutron imaging. Monte Carlo simulations of GOS scintillator show that the capability of its spatial resolution is towards the micron level. Through the time-of-flight method, the light output of a GOS scintillator was measured to be 217 photons per captured neutron, ~100 times lower than that of a ZnS/LiF:Ag scintillator. A detector prototype has been developed to evaluate the imaging solution with the GOS scintillator by neutron beam tests. The measured spatial resolution is ~36 ㎛ (28 line pairs/mm) at the modulation transfer function (MTF) of 10%, mainly limited by the low experimental collimation ratio of the beamline. The weak light output of the GOS scintillator requires an enormous increase in the neutron flux to reduce the exposure time for practical applications.

벼논에서 open-path와 closed chamber 방법 간 메탄 배출량 비교 (Comparison of CH4 Emission by Open-path and Closed Chamber Methods in the Paddy Rice Fields)

  • 정현철;최은정;김건엽;이선일;이종식
    • 환경생물
    • /
    • 제36권4호
    • /
    • pp.507-516
    • /
    • 2018
  • 벼재배 논에서 온실가스 측정을 위해 사용되는 closed 챔버법은 시 공간적으로 변동 폭이 큰 메탄 플럭스를 측정하는 데는 한계가 있다. 이러한 문제점을 해결하고자 메탄플럭스 측정에 있어 에디공분산을 기반으로 하는 open-path 방법과 closed 챔버법을 비교분석하였다. 벼 재배 기간 중 메탄 플럭스 변동은 두 방법 모두 비슷한 경향을 보였고 closed 챔버를 이용한 메탄 측정 시간대의 값은 open-path 측정에 의한 값과 고도로 유의한 상관을 보였다. 다만 총배출량에 있어서 두 측정 방법 간에 나타난 약 31%의 차이가 발생했는데 이는 closed 챔버법에 따른 과다 측정과 open-path에 의한 과소측정으로 생각해 볼 수 있다. 정확한 원인 분석을 위해서 향후에도 추가적인 연구가 필요할 것으로 판단된다.

Synthesis of barium-doped PVC/Bi2WO6 composites for X-ray radiation shielding

  • Gholamzadeh, Leila;Sharghi, Hamed;Aminian, Mohsen Khajeh
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.318-325
    • /
    • 2022
  • In this study, composites containing undoped and barium-doped Bi2WO6:Ba2+were investigated for their shielding against diagnostic X-ray. At first, Bi2WO6 and barium-doped Bi2WO6 were synthesized with different weight percentages of barium oxide through a hydrothermal process. The as-synthesized nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and Raman spectroscopy (RS). After that, some shields were generated with undoped and barium-doped Bi2WO6:Ba2+ nanostructure particles incorporated into polyvinyl chloride (PVC) polymer with different thicknesses and 15% weight of the nanostructure. Finally, the prepared samples were exposed to an X-ray tube at 40, 80, and 120 kV voltages, 10 mAs and, 44.5 cm SID (i.e. the distance from the X-ray beam source to the specimen). Linear and mass attenuation coefficients were also calculated for different samples. The results indicated that, among the samples, the one with 7.5 mmol barium-doped Bi2WO6 had the most attenuation at the voltage of 40kV, and the attenuation coefficients would increase with an increase in the amount of barium. The samples with 15 and 17.5 mmol barium-doped Bi2WO6 had higher attenuation than the others at 80 and 120 kV. Moreover, the half-value layer (HVL), tenth-value layer (TVL) and 0.25 mm lead equivalent thickness were calculated for all the samples. The lowest HVL value was for the sample with 7.5 mmol barium-doped Bi2WO6. As the result clearly show, an increment in the barium-doping content leads to a decrease in both HVL and TVL. In every three voltages, 0.25 mm lead equivalent thickness of the barium-doped composites (7.5 mmol and 15 mmol) had less than the other composites. The lowest value of 0.25 mm lead equivalent thickness was 7.5 barium-doped in 40 kV voltage and 15 mmol barium-doped in 80 kV and 120 kV voltages. These results were obtained only for 15% weight of the nanostructure.

드론 화상 및 LiDAR 스캐닝의 정합처리 자료를 활용한 노후 구조물 3차원 정밀 모델링에 관한 연구 (A Study on the 3D Precise Modeling of Old Structures Using Merged Point Cloud from Drone Images and LiDAR Scanning Data)

  • 신찬휘;민경조;김경규;전푸른;박훈;조상호
    • 화약ㆍ발파
    • /
    • 제40권4호
    • /
    • pp.15-26
    • /
    • 2022
  • 최근 건축물의 노령화에 따른 건물 전체 기능저하와 화재 및 지반침하와 같은 재난에 따른 건축물의 안정성 저하로 구조물 해체 수요가 급격히 증가하는 추세이다. 특히, 구조물 구성부위의 변형이나 손상의 정도가 심각한 구조물은 부재 내 집중하중이 발생하여 구조물 전체의 안정성이 저하되어 빠른 시일 내에 안전하게 구조물 해체가 가능한 시공기술에 대한 수요가 증가하고 있다. 또한, 노후 구조물에 대한 비인가 증축이나 불법 개조와 같은 구조적 변경으로 시공 당시 건물의 설계도면과 상이한 경우가 빈번하다고 보고되어오고 있다. 본 연구에서는 해체 대상 구조물의 시공 당시 도면과 현 시점 구조와의 차이점을 보완하기 위하여, 실내외 구조 표면에 대한 실측값을 활용하여 3차원 모델을 역설계하는 기법을 제안하였다. 실제 해체 시공 예정인 건축물을 대상으로 구조물 외곽에 대하여 드론 촬영을 실시하고 구조물 내부는 LiDAR 스캐닝을 수행하여 건물외곽과 실내에 대한 점군데이터를 획득한다. 각각 점군데이터는 Smartmapper를 활용하여 정밀하게 정합되며 2차원 도면제작과 3차원 구조해석용 모델 작성에 사용된다. 제안된 역설계 기법을 검증하기 위하여 드론화상자료, LiDAR 스캐너자료, 정합자료로부터 생성된 3차원 모델과 실측된 부재간의 거리를 비교하였다.

이중 파장 심자외선 카타디옵트릭 NA 0.6 대물렌즈 광학 설계 (Catadioptric NA 0.6 Objective Design in 193 nm with 266 nm Autofocus)

  • 김도희;주석영;이준호;김학용;양호순
    • 한국광학회지
    • /
    • 제34권2호
    • /
    • pp.53-60
    • /
    • 2023
  • 193 nm에서 반도체 전공정 검사 장치에 적용될 수 있는 반사 굴절 혼합 형식(카타디옵트릭)의 수치 구경(numerical aperture, NA) 0.6 대물렌즈를 설계하였다. 200 nm 공간 분해능 및 0.15 mm 이상의 시야를 확보하기 위하여, 먼저 렌즈 전체 배치를 포커싱 렌즈 그룹, 필드 렌즈 그룹 및 NA 변환 그룹으로 구성하였으며, 선행 그룹에 포커싱된 빔의 수치 구경 값을 필요 값, 즉 0.6으로 변환하는 기능을 수행한다. 총 11매의 광학 소자로 구성된 최종 설계는 모든 관측 시야에 대하여 λ/80 이하의 RMS 파면 수차를 만족하였다. 또한 고분해능 대물렌즈의 높은 환경 민감도로 인한 온도 변화에 따른 광학계 성능 해석 결과, ±0.1 ℃의 온도 변화에서도 목표 성능 이하로의 성능 저하가 확인되어 온도 변화에 따른 광학 보상이 반드시 필요하였다. 이에 초점면 이동을 보상자로 적용할 경우, 20 ± 1.2 ℃까지 RMS 파면 수차 변화량이 λ/30 이하로 목표 성능을 만족하여 실제 반도체 공정 환경에서도 이용이 가능함을 확인하였다.

Review of laser-plasma physics research and applications in Korea

  • W. Bang;B. I. Cho;M. H. Cho;M. S. Cho;M. Chung;M. S. Hur;G. Kang;K. Kang;T. Kang;C. Kim;H. N. Kim;J. Kim;K.B. Kim;K. N. Kim;M. Kim;M. S. Kim;M. Kumar;H. Lee;H. W. Lee;K. Lee;I. Nam;S. H. Park;V. Phung;W. J. Ryu;S. Y. Shin;H. S. Song;J. Song;J. Won;H. Suk
    • Journal of the Korean Physical Society
    • /
    • 제80권
    • /
    • pp.698-716
    • /
    • 2022
  • Laser plasmas can be produced when high-power laser beams are focused in matter. A focused laser beam of TW(terawatt)-level high power has an extremely strong electric field, so neutral atoms are immediately ionized by the laser electric field, leading to a laser-produced plasma. The laser plasma can be produced by small table-top TW lasers based on the CPA (chirped-pulse amplification) technique, and now they are rather easily available even in university laboratories. In Korea, there are several CPA-based TW (or even petawatt) lasers in a few institutions, and they have been used for diverse laser plasma physics research and applications, including the laser acceleration for electrons and ions, high-power THz (tera-hertz) generation, advanced light sources, high-energy-density plasmas, plasma optics, etc. This paper reviews some of the laser plasma physics research and applications that have been performed in several universities and research institutes.

머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구 (Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask)

  • 김수길;정태식;임상욱;박영목;박달
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.86-92
    • /
    • 2010
  • 곡면 형태의 피부표면의 방사선량을 방사선크롬 필름과 열형광 선량계를 이용하여 측정하고자 한다. 또한 고정 장치의 사용으로 인한 고에너지 방사선의 피부보존효과의 감쇠를 정량적으로 측정하여 Monte-Carlo 프로그램으로 계산한 값과 비교하고자 한다. 머리-목 그리고 어깨의 곡면 형태를 모의하여 만든 11 cm 직경의 원통 팬텀에 $40{\times}40\;cm^2$의 조사야, SAD 100 cm, 6 MV의 방사선을 쪼였다. 또한 관련된 치료 상황과 유사한 조건으로 만들기 위해 그물망 형태의 고정 마스크를 원통형 팬텀에 씌워서 실험하였다. 원통 팬텀의 원둘레 주위를 따라 $0^{\circ}$에서 $360^{\circ}$까지의 피부선량곡선을 구하였다. 방사선크롬 필름을 이용하여 구한, 정면 입사위치($0^{\circ}$)에서의 피부선량은 최대값 깊이($D_{max}$) 방사선량의 47%, 접선 각도인 $90^{\circ}$에서는 61%로 측정되었다. 1.5 mm의 고정마스크를 씌운 경우 $0^{\circ}$ 입사지점에서는 59%, $80^{\circ}$에서는 78%였다. TLD를 통한 결과는 고정마스크를 씌운 경우 $0^{\circ}$ 입사지점에서는 66%, $80^{\circ}$에서는 80%였고 필름의 경우와 유사한 형태를 보였다. 고정 마스크를 머리-목 그리고 어깨 부위에 부착시켜서 치료를 하는 경우에 접선 부근 각도에서의 피부선량이 치료선량과 거의 같은 값을 보였다. 곡면 부위의 피부에는 고정성을 잃지 않는 범위 안에서 보다 더 얇고 더 구멍이 많이 뚫린 고정마스크를 사용해야 과도한 피부선량을 줄일 수 있을 것으로 사료된다.

필름을 사용한 세기변조치료법에 대한 선량측정 (Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation)

  • 주상규;여인환;허승재;최병기;박영환;안용찬;김대용;공영건
    • Radiation Oncology Journal
    • /
    • 제20권2호
    • /
    • pp.172-178
    • /
    • 2002
  • 목적 : 원자 번호가 높은 물질로 구성된 필름은 저 에너지 광자선에 과반응하여 선량 측정 시 인체조직에서와 다른 흡수양상을 보인다. 이러한 현상은 조사면의 경계인 반음영 및 그 외곽 부위에서 두드러지게 관찰된다. 따라서 반음영이 조사면내에 위치하게되는 세기변조치료법에서 필름을 이용한 선량 측정 시 이러한 현상이 미치는 영향을 분석하고 개선 방법을 강구하고자 한다. 대상 및 방법 : 6 MV X-선의 5~7개의 크기가 다른 고정형 조사면을 이용해 두가지 유형의 세기변조 조사면을 만들었으며 전리함 및 저감도 측정용 필름을 사용하여 각 조사면의 빔 프로파일을 측정했다. 측정 깊이와 최대 조사면적을 변화시켰으며 필름에 대해 수직 및 수평 조사하여 이에 따른 선량 분포 변화를 관찰했다. 또한 필름 선량 측정시 저 에너지 광자선에 의한 선량 과평가 현상을 막기 위해 납 필터(0.01 inch)를 필름 양측에 부착하여 이로 인한 영향을 관찰했다. 결과 : 필름만을 사용한 빔 프로파일에서는, 전리함 측정치에 비해 저 선량 영역 및 조사면 경계에서의 선량 과평가 현상이 수직 및 수평 조사 모두에서 관찰되었다. 이러한 현상은 측정 깊이가 증가함에 따라 크게 나타났으며 10cm 깊이의 역 피라미드형 세기변조 조사면 중심에서 최고 약 15%의 상대오차를 보였다. 필터를 사용한 경우에서는, 수직 조사 시 필터에 의한 선량 저 평가 현상이 관찰되었으나 수평 조사에서는 전리함 측정치와 3% 이내의 오차를 보여 매우 잘 일치하였다. 결론 : 필름을 이용한 세기변조 조사면의 선량 측정 시 선량 과반응에 의한 오차는 조사면의 조합 형태 및 반음영 위치와 밀접한 관계를 가지며, 선량 평가 시 이에 대한 고려가 필요하다. 납 필터를 사용한 수평조사 방법은 이러한 오차를 줄이는데 도움을 주며 입사 방사선의 물리적 특성을 고려한 적정 두께의 필터 선택이 요구된다.

6MV 광자선에서 전자오염 감소에 관한 연구 (Reduction of Electron Contamination Using a Filter for 6MV Photon Beam)

  • 이철수;유명진;염하용
    • Radiation Oncology Journal
    • /
    • 제15권2호
    • /
    • pp.159-165
    • /
    • 1997
  • 목적 : 광자선과 블록을 얻는 트레이와의 상호작용에 의해 생성된 2차 전자는 피하층에 과도 한 선량증가의 원인이 된다. 이런 전자오염으로 인한 표면선량을 감소시키기 위해 트레이 아래 전자필터를 부착하는 것이 유용하다. 대상 및 방법 :두께가 다른 Cu판, Al판 그리고 Cu/Al 복합판을 사용하여 전자오염에 의한 표면선량을 감소시키는 효과를 측정하였다. 최적의 필터를 찾기 위해서 $10m\times10cm$ 조사야와 SSD 78.5cm의 기하학적 모형으로 표면에서부터 최대선량 지점까지 2mm 간격으로 흡수선량을 측정하였다. 최적필터의 조사야 의존성을 구하기 위해서 $4cm\times4cm$에서부터 $25cm\times25cm$까지 조사면적을 변화시켜가며 흡수선량을 측정하였다 결과 : 표면선량은 조사면적을 증가시키면 서서히 증가하였고 $15cm\times15cm$ 조사면적 이상에 서는 표면선량이 급속히 증가하였다. Al판을 사용했을 경우 표면선량이 최대선량 지점의 선량보다 낮게 유지되지 않으므로 Al판은 전자필터로는 부적합하였으며 0.5mm Cu판과 Cu/Al=0.28mm/1.5mm 복합판이 최적 전자필터로 결정되었다. 두가지 최적필터의 경우 $4cm\times4cm$ 조사면에서는 표면선량을 $5.5\%$(tray 사용할때 표면선량에서 filter 사용할때 표면선량을 뺀 것) 낮출 수 있었고 $10cm\times10cm$에서는 $11.3\%,\;25cm\times25cm$에서는 $21.3\%$로 낮출 수 있었다. 결론 : 전자오염에 기인한 표면선량은 조사면적에 의존하였고 트레이를 설치했을때 표면의 전자오염은 많았고 특히 조사면적이 클 때 표면의 전자오염은 더욱 증가하였다 표면 및 build-up영역의 선량 특성을 측정한 결과 0.5mm Cu판과 Cu/Al=0.28mm/1.5mm 복합판이 최적 필터로 결정되었다. 트레이 밑에 최적 필터를 부착하면 표면선량을 유효하게 감소시킬 수 있었고 필터의 효과는 조사면적이 클 때 더욱 좋았다.

  • PDF

Small-Angle X-ray Scattering Station 4C2 BL of Pohang Accelerator Laboratory for Advance in Korean Polymer Science

  • Yoon, Jin-Hwan;Kim, Kwang-Woo;Kim, Je-Han;Heo, Kyu-Young;Jin, Kyeong-Sik;Jin, Sang-Woo;Shin, Tae-Joo;Lee, Byeong-Du;Rho, Ye-Cheol;Ahn, Byung-Cheol;Ree, Moon-Hor
    • Macromolecular Research
    • /
    • 제16권7호
    • /
    • pp.575-585
    • /
    • 2008
  • There are two beamlines (BLs), 4C1 and 4C2, at the Pohang Accelerator Laboratory that are dedicated to small angle X-ray scattering (SAXS). The 4C1 BL was constructed in early 2000 and is open to public users, including both domestic and foreign researchers. In 2003, construction of the second SAXS BL, 4C2, was complete and commissioning and user support were started. The 4C2 BL uses the same bending magnet as its light source as the 4C1 BL. The 4C1 BL uses a synthetic double multilayer monochromator, whereas the 4C2 BL uses a Si(111) double crystal monochromator for both small angle and wide angle X-ray scattering. In the 4C2 BL, the collimating mirror is positioned behind the monochromator in order to enhance the beam flux and energy resolution. A toroidal focusing mirror is positioned in front of the monochromator to increase the beam flux and eliminate higher harmonics. The 4C2 BL also contains a digital cooled charge coupled detector, which has a wide dynamic range and good sensitivity to weak scattering, thereby making it suitable for a range of SAXS and wide angle X-ray scattering experiments. The general performance of the 4C2 BL was initially tested using standard samples and further confirmed by the experience of users during three years of operation. In addition, several grazing incidence X-ray scattering measurements were carried out at the 4C2 BL.